Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 30
Filter
Add more filters










Publication year range
1.
Pediatrics ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-38953121

ABSTRACT

OBJECTIVES: This study assessed the state of pediatric medical device (PMD) development by comparing PMD clinical trials to pediatric trials evaluating drugs and biologics, from 1999 to 2022. METHODS: The site https://www.clinicaltrials.gov was used to identify and quantify both PMD clinical trials and pediatric trials for drugs and biologics. Clinical specialty was also assessed. The institutions included were the 7 children's hospitals primarily affiliated with the Food and Drug Administration (FDA) Pediatric Device Consortia (PDC) grant program between 2018 and 2023. For a national comparison, an additional search assessed PMD trials across all US medical institutions. RESULTS: A total of 243 PMD clinical trials were identified at the FDA-PDC institutions on the basis of the year of initiation; the average number of PMD trials initiated per year per institution was 1.5 from 1999 to 2022. However, PMD trials significantly increased during the period 2014 to 2022 compared with 1999 to 2013 (P < .001); the rate of initiation of drug and biologic pediatric trials demonstrated no significant differences between these time periods. A national survey of all institutions initiating PMD trials, and drugs and biologics trials, identified 1885 PMD trials out of a total 12 943. A comparable trend was noted in the national survey with initiation of PMD trials increasing significantly from 2014 to 2022 (P < .001), compared with 1999 to 2013, whereas the rate of initiation of drug and biologic trials during these periods did not demonstrate a significant change. CONCLUSIONS: Although pediatric clinical trial initiation for drugs and biologics remained stable from 1999 to 2022, the rate of new PMD trials significantly increased during the period 2014 to 2022 at FDA-PDC institutions and nationally.

2.
Atherosclerosis ; 390: 117432, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38241977

ABSTRACT

BACKGROUND AND AIMS: Hypercholesterolemia (HC) has previously been shown to augment the restenotic response in animal models and humans. However, the mechanistic aspects of in-stent restenosis (ISR) on a hypercholesterolemic background, including potential augmentation of systemic and local inflammation precipitated by HC, are not completely understood. CD47 is a transmembrane protein known to abort crucial inflammatory pathways. Our studies have examined the interrelation between HC, inflammation, and ISR and investigated the therapeutic potential of stents coated with a CD47-derived peptide (pepCD47) in the hypercholesterolemic rabbit model. METHODS: PepCD47 was immobilized on metal foils and stents using polybisphosphonate coordination chemistry and pyridyldithio/thiol conjugation. Cytokine expression in buffy coat-derived cells cultured over bare metal (BM) and pepCD47-derivatized foils demonstrated an M2/M1 macrophage shift with pepCD47 coating. HC and normocholesterolemic (NC) rabbit cohorts underwent bilateral implantation of BM and pepCD47 stents (HC) or BM stents only (NC) in the iliac location. RESULTS: A 40 % inhibition of cell attachment to pepCD47-modified compared to BM surfaces was observed. HC increased neointimal growth at 4 weeks post BM stenting. These untoward outcomes were mitigated in hypercholesterolemic rabbits treated with pepCD47-derivatized stents. Compared to NC animals, inflammatory cytokine immunopositivity and macrophage infiltration of peri-strut areas increased in HC animals and were attenuated in HC rabbits treated with pepCD47 stents. CONCLUSIONS: Augmented inflammatory responses underlie severe ISR morphology in hypercholesterolemic rabbits. Blockage of initial platelet and leukocyte attachment to stent struts through CD47 functionalization of stents mitigates the pro-restenotic effects of hypercholesterolemia.


Subject(s)
Coronary Restenosis , Hypercholesterolemia , Humans , Animals , Rabbits , Hypercholesterolemia/complications , CD47 Antigen , Coronary Restenosis/etiology , Coronary Restenosis/prevention & control , Disease Models, Animal , Stents , Inflammation , Peptides/pharmacology , Cytokines
3.
Sci Transl Med ; 15(677): eadc9606, 2023 01 04.
Article in English | MEDLINE | ID: mdl-36599005

ABSTRACT

Degenerative mitral valve (MV) regurgitation (MR) is a highly prevalent heart disease that requires surgery in severe cases. Here, we show that a decrease in the activity of the serotonin transporter (SERT) accelerates MV remodeling and progression to MR. Through studies of a population of patients with MR, we show that selective serotonin reuptake inhibitor (SSRI) use and SERT promoter polymorphism 5-HTTLPR LL genotype were associated with MV surgery at younger age. Functional characterization of 122 human MV samples, in conjunction with in vivo studies in SERT-/- mice and wild-type mice treated with the SSRI fluoxetine, showed that diminished SERT activity in MV interstitial cells (MVICs) contributed to the pathophysiology of MR through enhanced serotonin receptor (HTR) signaling. SERT activity was decreased in LL MVICs partially because of diminished membrane localization of SERT. In mice, fluoxetine treatment or SERT knockdown resulted in thickened MV leaflets. Similarly, silencing of SERT in normal human MVICs led to up-regulation of transforming growth factor ß1 (TGFß1) and collagen (COL1A1) in the presence of serotonin. In addition, treatment of MVICs with fluoxetine not only directly inhibited SERT activity but also decreased SERT expression and increased HTR2B expression. Fluoxetine treatment and LL genotype were also associated with increased COL1A1 expression in the presence of serotonin in MVICs, and these effects were attenuated by HTR2B inhibition. These results suggest that assessment of both 5-HTTLPR genotype and SERT-inhibiting treatments may be useful tools to risk-stratify patients with MV disease to estimate the likelihood of rapid disease progression.


Subject(s)
Mitral Valve Insufficiency , Mitral Valve , Humans , Animals , Mice , Mitral Valve/metabolism , Mitral Valve Insufficiency/metabolism , Fluoxetine/pharmacology , Fluoxetine/therapeutic use , Fluoxetine/metabolism , Serotonin Plasma Membrane Transport Proteins/genetics , Serotonin Plasma Membrane Transport Proteins/metabolism , Serotonin/metabolism , Serotonin/pharmacology , Selective Serotonin Reuptake Inhibitors/pharmacology , Selective Serotonin Reuptake Inhibitors/therapeutic use
4.
Sci Rep ; 12(1): 19212, 2022 11 10.
Article in English | MEDLINE | ID: mdl-36357462

ABSTRACT

Impaired endothelialization of endovascular stents has been established as a major cause of in-stent restenosis and late stent thrombosis. Attempts to enhance endothelialization of inner stent surfaces by pre-seeding the stents with endothelial cells in vitro prior to implantation are compromised by cell destruction during high-pressure stent deployment. Herein, we report on the novel stent endothelialization strategy of post-deployment seeding of biotin-modified endothelial cells to avidin-functionalized stents. Acquisition of an avidin monolayer on the stent surface was achieved by consecutive treatments of bare metal stents (BMS) with polyallylamine bisphosphonate, an amine-reactive biotinylation reagent and avidin. Biotin-modified endothelial cells retain growth characteristics of normal endothelium and can express reporter transgenes. Under physiological shear conditions, a 50-fold higher number of recirculating biotinylated cells attached to the avidin-modified metal surfaces compared to bare metal counterparts. Delivery of biotinylated endothelial cells to the carotid arterial segment containing the implanted avidin-modified stent in rats results in immediate cell binding to the stent struts and is associated with a 30% reduction of in-stent restenosis in comparison with BMS.


Subject(s)
Coronary Restenosis , Rats , Animals , Coronary Restenosis/etiology , Endothelial Cells , Avidin , Biotin , Stents/adverse effects , Constriction, Pathologic/complications
5.
Proc Natl Acad Sci U S A ; 119(6)2022 02 08.
Article in English | MEDLINE | ID: mdl-35131859

ABSTRACT

Bioprosthetic heart valves (BHV) fabricated from glutaraldehyde-fixed heterograft tissue, such as bovine pericardium (BP), are widely used for treating heart valve disease, a group of disorders that affects millions. Structural valve degeneration (SVD) of BHV due to both calcification and the accumulation of advanced glycation end products (AGE) with associated serum proteins limits durability. We hypothesized that BP modified with poly-2-methyl-2-oxazoline (POZ) to inhibit protein entry would demonstrate reduced accumulation of AGE and serum proteins, mitigating SVD. In vitro studies of POZ-modified BP demonstrated reduced accumulation of serum albumin and AGE. BP-POZ in vitro maintained collagen microarchitecture per two-photon microscopy despite AGE incubation, and in cell culture studies was associated with no change in tumor necrosis factor-α after exposure to AGE and activated macrophages. Comparing POZ and polyethylene glycol (PEG)-modified BP in vitro, BP-POZ was minimally affected by oxidative conditions, whereas BP-PEG was susceptible to oxidative deterioration. In juvenile rat subdermal implants, BP-POZ demonstrated reduced AGE formation and serum albumin infiltration, while calcification was not inhibited. However, BP-POZ rat subdermal implants with ethanol pretreatment demonstrated inhibition of both AGE accumulation and calcification. Ex vivo laminar flow studies with human blood demonstrated BP-POZ enhanced thromboresistance with reduced white blood cell accumulation. We conclude that SVD associated with AGE and serum protein accumulation can be mitigated through POZ functionalization that both enhances biocompatibility and facilitates ethanol pretreatment inhibition of BP calcification.


Subject(s)
Heart Valve Diseases/drug therapy , Heart Valve Diseases/therapy , Oxazoles/pharmacology , Pericardium/drug effects , Animals , Biocompatible Materials , Calcification, Physiologic/drug effects , Calcinosis/drug therapy , Calcinosis/metabolism , Calcinosis/therapy , Cell Line , Collagen/metabolism , Ethanol/pharmacology , Glycation End Products, Advanced/metabolism , Heart Valve Diseases/metabolism , Heart Valve Prosthesis , Heterografts/drug effects , Humans , Male , Oxidation-Reduction/drug effects , Pericardium/metabolism , Rats , Rats, Sprague-Dawley , THP-1 Cells
6.
J Vis Exp ; (166)2020 12 03.
Article in English | MEDLINE | ID: mdl-33346187

ABSTRACT

The key complications associated with bare metal stents and drug eluting stents are in-stent restenosis and late stent thrombosis, respectively. Thus, improving the biocompatibility of metal stents remains a significant challenge. The goal of this protocol is to describe a robust technique of metal surface modification by biologically active peptides to increase biocompatibility of blood contacting medical implants, including endovascular stents. CD47 is an immunological species-specific marker of self and has anti-inflammatory properties. Studies have shown that a 22 amino acid peptide corresponding to the Ig domain of CD47 in the extracellular region (pepCD47), has anti-inflammatory properties like the full-length protein. In vivo studies in rats, and ex vivo studies in rabbit and human blood experimental systems from our lab have demonstrated that pepCD47 immobilization on metals improves their biocompatibility by preventing inflammatory cell attachment and activation. This paper describes the step-by step protocol for the functionalization of metal surfaces and peptide attachment. The metal surfaces are modified using polyallylamine bisphosphate with latent thiol groups (PABT) followed by deprotection of thiols and amplification of thiol-reactive sites via reaction with polyethyleneimine installed with pyridyldithio groups (PEI-PDT). Finally, pepCD47, incorporating terminal cysteine residues connected to the core peptide sequence through a dual 8-amino-3,6-dioxa-octanoyl spacer, are attached to the metal surface via disulfide bonds. This methodology of peptide attachment to metal surface is efficient and relatively inexpensive and thus can be applied to improve biocompatibility of several metallic biomaterials.


Subject(s)
Blood Cells/cytology , Metals/pharmacology , Peptides/metabolism , Prostheses and Implants , Animals , Anti-Inflammatory Agents/pharmacology , Antigens, CD/metabolism , Antigens, Differentiation, Myelomonocytic/metabolism , Blood Cells/drug effects , CD47 Antigen/metabolism , Cell Adhesion/drug effects , Fluorescent Dyes/metabolism , Humans , Macrophages/cytology , Macrophages/drug effects , Microscopy, Fluorescence , Monocytes/cytology , Monocytes/drug effects , Polyethyleneimine/chemistry , Rabbits , Rats , Spectrometry, Fluorescence
7.
Colloids Surf B Biointerfaces ; 192: 111060, 2020 Apr 18.
Article in English | MEDLINE | ID: mdl-32450498

ABSTRACT

The blood compatibility of various intravascular (IV) devices (e.g., catheters, sensors, etc.) is compromised by activation of platelets that can cause thrombus formation and device failure. Such devices also carry a high risk of microbial infection. Recently, nitric oxide (NO) releasing polymers/devices have been proposed to reduce these clinical problems. CD47, a ubiquitously expressed transmembrane protein with proven anti-inflammation/anti-platelet properties when immobilized on polymeric surfaces, is a good candidate to complement NO release in both effectiveness and longevity. In this work, we successfully appended CD47 peptides (pepCD47) to the surface of biomedical grade polyurethane (PU) copolymers. SIRPα binding and THP-1 cell attachment experiments strongly suggested that the pepCD47 retains its biological properties when bound to PU films. In spite of the potentially high reactivity of NO toward various amino acid residues in CD47, the efficacy of surface-immobilized pepCD47 to prevent inflammatory cell attachment was not inhibited after being subjected to a high flux of NO for three days, demonstrating excellent compatibility of the two species. We further constructed a CD47 surface immobilized silicone tubing filled with NO releasing S-nitrosoglutathione/ascorbic acid (GSNO/AA) solution for synergistic biocompatibility evaluation. Via an ex vivo Chandler loop model, we demonstrate for the first time that NO release and CD47 modification could function synergistically at the blood/material interface and produce greatly enhanced anti-inflammatory/anti-platelet effects. This concept should be readily implementable to create a new generation of thromboresistant/antimicrobial implantable devices.

8.
Acta Biomater ; 104: 231-240, 2020 03 01.
Article in English | MEDLINE | ID: mdl-31935523

ABSTRACT

In-stent restenosis (ISR) and late stent thrombosis are the major complications associated with the use of metal stents and drug eluting stents respectively. Our lab previously investigated the use of peptide CD47 in improving biocompatibility of bare metal stents in a rat carotid stent model and our results demonstrated a significant reduction in platelet deposition and ISR. However, this study did not characterize the stability of the pepCD47 on metal surfaces post storage, sterilization and deployment. Thus, the objective of the present study was 1) to test the stability of the peptide post - storage, sterilization, exposure to shear and mechanical stress and 2) to begin to expand our current knowledge of pepCD47 coated metal surfaces into the preclinical large animal rabbit model. Our results show that the maximum immobilization density of pepCD47 on metal surfaces is approximately 350 ng/cm2. 100% of the pepCD47 was retained on the metal surface post 24 weeks of storage at 4 °C, exposure to physiological shear stress, and mechanical stress of stent expansion. The bioactivity of the pepCD47 was found to be intact post 24 weeks of storage and ethylene oxide sterilization. Finally our ex vivo studies demonstrated that compared to bare metal the rabbit pepCD47 coated surfaces showed - 45% reduced platelet adhesion, a 10-fold decrease in platelet activation, and 93% endothelial cell retention. Thus, our data suggests that pepCD47 coating on metal surfaces is stable and rabbit pepCD47 shows promising preliminary results in preventing thrombosis and not inhibiting the growth of endothelial cells. STATEMENT OF SIGNIFICANCE: Biocompatibility of bare metal stents is a major challenge owing to the significantly high rates of in-stent restenosis. Previously we demonstrated that peptide CD47 functionalization improves the biocompatibility of bare metal stents in rat model. A similar trend was observed in our ex vivo studies where rabbit blood was perfused over the rabbit pepCD47 functionalized surfaces. These results provide valuable proof of concept data for future in vivo rabbit model studies. In addition, we investigated stability of the pepCD47 on metal surface and observed that pepCD47 coating is stable over time and resistant to industrially relevant pragmatic challenges.


Subject(s)
CD47 Antigen/chemistry , Peptides/pharmacology , Stainless Steel/pharmacology , Adult , Animals , Blood Cells/cytology , Blood Cells/drug effects , Cell Communication/drug effects , Endothelial Cells/cytology , Endothelial Cells/drug effects , Female , Humans , Male , Metals/pharmacology , Rabbits , Shear Strength , Sterilization , Stress, Mechanical , Surface Properties
9.
Exp Biol Med (Maywood) ; 241(10): 1033-41, 2016 05.
Article in English | MEDLINE | ID: mdl-27190273

ABSTRACT

Addressing the aberrant interactions between immune cells and biomaterials represents an unmet need in biomaterial research. Although progress has been made in the development of bioinert coatings, identifying and targeting relevant cellular and molecular pathways can provide additional therapeutic strategies to address this major healthcare concern. To that end, we describe the immune inhibitory motif, receptor-ligand pairing of signal regulatory protein alpha and its cognate ligand CD47 as a potential signaling pathway to enhance biocompatibility. The goals of this article are to detail the known roles of CD47-signal regulatory protein alpha signal transduction pathway and to describe how immobilized CD47 can be used to mitigate the immune response to biomaterials. Current applications of CD47-modified biomaterials will also be discussed herein.


Subject(s)
Biocompatible Materials/metabolism , Biocompatible Materials/pharmacology , CD47 Antigen/metabolism , Immunologic Factors/metabolism , Immunologic Factors/pharmacology , Animals , Biocompatible Materials/chemistry , Humans , Immunologic Factors/chemistry , Signal Transduction
10.
Biomaterials ; 87: 82-92, 2016 May.
Article in English | MEDLINE | ID: mdl-26914699

ABSTRACT

The effectiveness of endovascular stents is hindered by in-stent restenosis (ISR), a secondary re-obstruction of treated arteries due to unresolved inflammation and activation of smooth muscle cells in the arterial wall. We previously demonstrated that immobilized CD47, a ubiquitously expressed transmembrane protein with an established role in immune evasion, can confer biocompatibility when appended to polymeric surfaces. In present studies, we test the hypothesis that CD47 immobilized onto metallic surfaces of stents can effectively inhibit the inflammatory response thus mitigating ISR. Recombinant CD47 (recCD47) or a peptide sequence corresponding to the Ig domain of CD47 (pepCD47), were attached to the surfaces of both 316L-grade stainless steel foils and stents using bisphosphonate coordination chemistry and thiol-based conjugation reactions to assess the anti-inflammatory properties of CD47-functionalized surfaces. Initial in vitro and ex vivo analysis demonstrated that both recCD47 and pepCD47 significantly reduced inflammatory cell attachment to steel surfaces without impeding on endothelial cell retention and expansion. Using a rat carotid stent model, we showed that pepCD47-functionalized stents prevented fibrin and platelet thrombus deposition, inhibited inflammatory cell attachment, and reduced restenosis by 30%. It is concluded that CD47-modified stent surfaces mitigate platelet and inflammatory cell attachment, thereby disrupting ISR pathophysiology.


Subject(s)
Anti-Inflammatory Agents/therapeutic use , CD47 Antigen/therapeutic use , Immobilized Proteins/therapeutic use , Inflammation/prevention & control , Stainless Steel/chemistry , Stents/adverse effects , Thrombosis/prevention & control , Animals , Anti-Inflammatory Agents/chemistry , Blood Platelets/drug effects , CD47 Antigen/chemistry , Carotid Arteries/surgery , Cell Line , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/therapeutic use , Humans , Immobilized Proteins/chemistry , Inflammation/etiology , Rats , Thrombosis/etiology
11.
J Vis Exp ; (90)2014 Aug 20.
Article in English | MEDLINE | ID: mdl-25178087

ABSTRACT

The foreign body reaction occurs when a synthetic surface is introduced to the body. It is characterized by adsorption of blood proteins and the subsequent attachment and activation of platelets, monocyte/macrophage adhesion, and inflammatory cell signaling events, leading to post-procedural complications. The Chandler Loop Apparatus is an experimental system that allows researchers to study the molecular and cellular interactions that occur when large volumes of blood are perfused over polymeric conduits. To that end, this apparatus has been used as an ex vivo model allowing the assessment of the anti-inflammatory properties of various polymer surface modifications. Our laboratory has shown that blood conduits, covalently modified via photoactivation chemistry with recombinant CD47, can confer biocompatibility to polymeric surfaces. Appending CD47 to polymeric surfaces could be an effective means to promote the efficacy of polymeric blood conduits. Herein is the methodology detailing the photoactivation chemistry used to append recombinant CD47 to clinically relevant polymeric blood conduits and the use of the Chandler Loop as an ex vivo experimental model to examine blood interactions with the CD47 modified and control conduits.


Subject(s)
Biocompatible Materials/chemistry , Extracorporeal Circulation/instrumentation , Foreign-Body Reaction/blood , Foreign-Body Reaction/chemically induced , Materials Testing/instrumentation , Polymers/chemistry , Blood Physiological Phenomena , Blood Platelets/chemistry , Blood Platelets/cytology , CD47 Antigen , Humans , Materials Testing/methods , Recombinant Proteins
12.
Polymers (Basel) ; 6(10): 2526-2551, 2014 Sep 29.
Article in English | MEDLINE | ID: mdl-25705515

ABSTRACT

Tissue contacting surfaces of medical devices initiate a host inflammatory response, characterized by adsorption of blood proteins and inflammatory cells triggering the release of cytokines, reactive oxygen species (ROS) and reactive nitrogen species (RNS), in an attempt to clear or isolate the foreign object from the body. This normal host response contributes to device-associated pathophysiology and addressing device biocompatibility remains an unmet need. Although widespread attempts have been made to render the device surfaces unreactive, the establishment of a completely bioinert coating has been untenable and demonstrates the need to develop strategies based upon the molecular mechanisms that define the interaction between host cells and synthetic surfaces. In this review, we discuss a family of transmembrane receptors, known as immunoreceptor tyrosine-based inhibitory motif (ITIM)-containing receptors, which show promise as potential targets to address aberrant biocompatibility. These receptors repress the immune response and ensure that the intensity of an immune response is appropriate for the stimuli. Particular emphasis will be placed on the known ITIM-containing receptor, Signal Regulatory Protein Alpha (SIRPhα), and its cognate ligand CD47. In addition, this review will discuss the potential of other ITIM-containing proteins as targets for addressing the aberrant biocompatibility of polymeric biomaterials.

13.
Biomaterials ; 34(34): 8640-9, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23948164

ABSTRACT

We have previously established that recombinant CD47 can ameliorate the inflammatory response to synthetic polymeric surfaces. Here, we begin to profile, at the transcriptional, translational and cell signaling level, the inflammatory cell response when blood interacts with CD47 modified polyvinyl chloride (PVC) (CD47-PVC). We used qPCR arrays to compare transcriptional changes between human whole blood exposed to CD47-PVC or PVC. Transcription of IL1F5, IL1F10, IL17F, CCL3, CCL8, CCL28, CXCL12, and CXCL13 was upregulated in blood exposed to PVC, compared to CD47-PVC. The increase in CCL3 and CCL8 transcription correlated with an increase in the chemokines' presence in the plasma. Exposure of blood to CD47-PVC resulted in an increase, compared to PVC, in transcription of CCL2, CCL4, CCL20, CXCL1, TGFß3, GDF3, GDF10, CD40LG, and TNFSF10. CD47-PVC exposure resulted in an increase of the following matrix metalloproteinase related genes: MMP1, MMP7, MMP13, and MMP16. Phosflow cytometry, and assays examining transcription factor binding, cell attachment, and genome-wide chromatin association indicated that members of the JAK-STAT signaling pathway, particularly JAK2 and STAT5, mediate inflammatory cell interactions with CD47-PVC. Our data demonstrate that differential molecular responses to CD47 involve downregulation of cytokines, upregulation of MMPs, and JAK/STAT signaling mechanisms.


Subject(s)
Blood/metabolism , CD47 Antigen/chemistry , Signal Transduction , Adolescent , Adult , Chemokines/genetics , Chemokines/metabolism , Cytokines/genetics , Cytokines/metabolism , Down-Regulation , Female , Humans , Janus Kinase 2/genetics , Janus Kinase 2/metabolism , Male , Matrix Metalloproteinase 1/genetics , Matrix Metalloproteinase 1/metabolism , Matrix Metalloproteinase 13/genetics , Matrix Metalloproteinase 13/metabolism , Matrix Metalloproteinase 7/genetics , Matrix Metalloproteinase 7/metabolism , Middle Aged , Polyvinyl Chloride/chemistry , STAT Transcription Factors/genetics , STAT Transcription Factors/metabolism , Transcription, Genetic , Transcriptional Activation , Up-Regulation , Young Adult
14.
J Biomed Mater Res A ; 101(1): 203-12, 2013 Jan.
Article in English | MEDLINE | ID: mdl-22847892

ABSTRACT

The morphological and inflammatory responses of adherent macrophages are correlated to evaluate the biocompatibility of surfaces. Monocyte-derived macrophage (MDM), THP-1, and THP-1 cells expressing GFP-actin chimeric protein were seeded onto glass, polyurethane (PU), and glass surface modified with quaternary ammonium salt functionalized chitosan (CH-Q) and hyaluronic acid (HA). Using confocal microscopy, the surface area, volume and 3D shape factor of adherent macrophages was quantified. For comparison, functional consequences of cell-surface interactions that activate macrophages and thereby elicit secretion of a proinflammatory cytokine were evaluated. Using an enzyme linked immune sorbent assay, tumor necrosis factor-alpha (TNF-α) was measured. On glass, macrophages exhibited mainly an amoeboid shape, exhibited the largest surface area, volume, and 3D shape factor and produced the most TNF-α. On PU, macrophages displayed mainly a hemispherical shape, exhibited an intermediate volume, surface area and 3D shape factor, and produced moderate TNF-α. In contrast, on CH-Q and HA surfaces, macrophages were spherical, exhibited the smallest volume, surface area, and 3D shape factor, and produced the least TNF-α. These studies begin to validate the use of GFP-actin-modified MDM as a novel tool to correlate cell morphology with inflammatory cell response.


Subject(s)
Biocompatible Materials/pharmacology , Cell Shape/drug effects , Macrophages/cytology , Tumor Necrosis Factor-alpha/biosynthesis , Actins/metabolism , Cell Adhesion/drug effects , Cell Size/drug effects , Enzyme-Linked Immunosorbent Assay , Genetic Vectors/genetics , Green Fluorescent Proteins/metabolism , Humans , Imaging, Three-Dimensional , Lentivirus/genetics , Macrophages/drug effects , Microscopy, Confocal , Monocytes/cytology , Recombinant Fusion Proteins/metabolism , Surface Properties , Transduction, Genetic , Tumor Necrosis Factor-alpha/metabolism
15.
Biomaterials ; 33(24): 5803-11, 2012 Aug.
Article in English | MEDLINE | ID: mdl-22613135

ABSTRACT

CD47 is a ubiquitously expressed transmembrane protein that, through signaling mechanisms mediated by signal regulatory protein alpha (SIRPα1), functions as a biological marker of 'self-recognition'. We showed previously that inflammatory cell attachment to polymeric surfaces is inhibited by the attachment of biotinylated recombinant CD47 (CD47B). We test herein the hypothesis that CD47 modified blood conduits can reduce platelet and neutrophil activation under clinically relevant conditions. We appended a poly-lysine tag to the C-terminus of recombinant CD47 (CD47L) allowing for covalent linkage to the polymer. SIRPα1 expression was confirmed in isolated platelets. We then compared biocompatibility between CD47B and CD47L functionalized polyvinyl chloride (PVC) surfaces and unmodified control PVC surfaces. Quantitative and Qualitative analysis of blood cell attachment to CD47B and CD47L surfaces, via scanning electron microscopy, showed strikingly fewer platelets attached to CD47 modified surfaces compared to control. Flow cytometry analysis showed that activation markers for neutrophils (CD62L) and platelets (CD62P) exposed to CD47 modified PVC were equivalent to freshly acquired control blood, while significantly elevated in the unmodified PVC tubing. In addition, ethylene oxide gas sterilization did not inhibit the efficacy of the CD47 modification. In conclusion, CD47 modified PVC inhibits both the adhesion and activation of platelets and neutrophils.


Subject(s)
Biocompatible Materials/chemistry , Blood Platelets/cytology , CD47 Antigen/immunology , Neutrophils/cytology , Antigens, Differentiation/genetics , Blood Platelets/immunology , Blood Platelets/metabolism , CD47 Antigen/chemistry , Cell Adhesion , Gene Expression , Humans , Neutrophils/immunology , Platelet Activation , Polyvinyl Chloride/chemistry , Receptors, Immunologic/genetics , Surface Properties
16.
Soft Matter ; 7: 3599-3606, 2011 Jan 01.
Article in English | MEDLINE | ID: mdl-21479122

ABSTRACT

Despite many advances in designing biocompatible materials, inflammation remains a problem in medical devices and implants. We report two methods, microcontact printing and photodegradation by UV exposure, to pattern dextran and hyaluronic acid on glass, as well as demonstrate their utility for use as an anti-inflammatory biomaterial. The dextran/glass patterned surface can be further modified by grafting hyaluronic acid to glass, creating a binary polysaccharide patterned surface. We used two geometries, 90 µm squares and 22 µm stripes, to study the human macrophage (THP-1) adhesion on the patterned surfaces containing dextran, hyaluronic acid and the binary pattern. The results indicate that a majority of the macrophages are non-adherent on hyaluronic acid for three day culture. The ranking of surfaces according to macrophage adhesion is 3-aminopropyl triethoxysilane-modified glass culture dish, dextranized surfaces, glass, and hyaluronic acid-modified surfaces. On the binary pattern of dextran and hyaluronic acid, macrophages preferentially attach and adhere to the dextranized area. Patterned surfaces provide an excellent platform for mimicking the complexity of the glycocalyx and investigating the interface between this surface and cells. This binary polysaccharide pattern also offers a new route to address anti-inflammatory potential of surface coatings on biomaterials in a high through-put fashion.

17.
Biomaterials ; 32(19): 4317-26, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21429575

ABSTRACT

CD47 is a transmembrane protein that is a marker of "self". CD47 binding to its cognate receptor in leukocytes and macrophages, signal-regulatory protein alpha (SIRPα), causes inhibition of inflammatory cell attachment. We hypothesized that immobilization of recombinant CD47 on polymeric surfaces would reduce inflammation. Recombinant CD47 was appended to polyvinyl chloride (PVC) or polyurethane (PU) surfaces via photoactivation chemistry. Cell culture studies showed that CD47 immobilization significantly reduced human neutrophil (HL-60) and human monocyte derived macrophage (MDM) (THP-1) attachment to PVC and PU respectively. A neutralizing antibody, directed against SIRPα, inhibited THP-1 and HL-60 binding to PU and PVC surfaces respectively. This antibody also increased the level of SIRPα tyrosine phosphorylation, thereby indicating a direct role for SIRPα mediated signaling in preventing inflammatory cell attachment. Studies using human blood in an ex vivo flow-loop showed that CD47 modified PVC tubing significantly reduced cell binding and neutrophil activation compared to unmodified tubing or poly-2-methoxy-ethylacrylate (PMEA) coated tubing. In ten-week rat subdermal implants, CD47 functionalized PU films showed a significant reduction in markers of MDM mediated oxidative degradation compared to unmodified PU. In conclusion, CD47 functionalized surfaces can resist inflammatory cell interactions both in vitro and in vivo.


Subject(s)
CD47 Antigen/immunology , Cell Adhesion/immunology , Inflammation/immunology , Polymers/chemistry , Animals , Antigens, Differentiation/immunology , Biocompatible Materials/chemistry , Biocompatible Materials/metabolism , CD47 Antigen/chemistry , CD47 Antigen/genetics , HL-60 Cells , Humans , Implants, Experimental , Macrophages/cytology , Macrophages/immunology , Male , Materials Testing , Molecular Structure , Photochemistry/methods , Polyurethanes/chemistry , Polyvinyl Chloride/chemistry , Rats , Rats, Sprague-Dawley , Receptors, Immunologic/immunology , Recombinant Proteins/chemistry , Recombinant Proteins/genetics , Recombinant Proteins/immunology , Surface Properties
18.
Acta Biomater ; 6(11): 4229-37, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20601235

ABSTRACT

The uniform alignment of endothelial cells inside small-diameter synthetic grafts can be directed by surface topographies such as microgrooves and microfibers to recapitulate the flow-induced elongation and alignment of natural endothelium. These surface micropatterns may also promote directional migration and potentially improve anastomotic ingrowth of endothelial cells inside the synthetic grafts. In this paper, we developed electrospinning and spin casting techniques to pattern the luminal surface of small-diameter polyurethane (PU) grafts with microfibers and microgrooves, respectively, and evaluated endothelial cell orientation on these surface micropatterns. Tracks of circumferentially oriented microfibers were generated by electrospinning PU onto a mandrel rotated at high velocity, whereas longitudinal tracks of microgrooves were generated by spin casting PU over a rotating poly(dimethylsiloxane) mold. We found that both PU grafts possessed longitudinal Young's moduli in the range of 0.43 ± 0.04 to 2.00 ± 0.40 MPa, comparable with values obtained from native artery. Endothelial cells seeded onto the grafts formed confluent monolayers with individual cells exhibiting elongated morphology parallel to the micropatterns. The cells were phenotypically similar to natural endothelium as assessed by the expression of the endothelial cell-specific marker, vascular endothelial cell cadherin. In addition, the cells were also responsive to stimulation with the pro-inflammatory cytokine tumor necrosis factor-α as assessed by the inducible expression of intercellular adhesion molecule-1. These results demonstrate that our micropatterned PU grafts possessed longitudinal Young's moduli in the same range as native vascular tissue and were capable of promoting the formation of aligned and cytokine-responsive endothelial monolayers.


Subject(s)
Blood Vessel Prosthesis , Polyurethanes/chemistry , Tissue Engineering/methods , Animals , Cattle , Cell Proliferation/drug effects , Cells, Cultured , Elastic Modulus/drug effects , Endothelial Cells/cytology , Endothelial Cells/drug effects , Endothelial Cells/metabolism , Endothelium, Vascular/drug effects , Endothelium, Vascular/metabolism , Humans , Intercellular Adhesion Molecule-1/metabolism , Microscopy, Electron, Scanning , Tensile Strength/drug effects , Tumor Necrosis Factor-alpha/pharmacology
19.
Biomaterials ; 31(25): 6394-9, 2010 Sep.
Article in English | MEDLINE | ID: mdl-20538335

ABSTRACT

We previously showed that blood outgrowth endothelial cells (BOECs) had a high affinity for polyurethane (PU) covalently configured with cholesterol residues (PU-Chol). However, the molecular mechanisms responsible for this enhanced affinity were not determined. CD47, a multifunctional transmembrane glycoprotein involved in cellular attachment, can form a cholesterol-dependent complex with integrin alpha(v)beta(3) and heterotrimeric G proteins. We tested herein the hypothesis that CD47, and the other components of the multi-molecular complex, enhance the attachment of BOECs to PU-Chol. Immunoprecipitation studies, of human and ovine BOECs, demonstrated that CD47 associates with integrin alpha(v) and integrin beta(3) as well as G(alphai-2) protein. The three-fold increase in BOEC attachment to PU-Chol, compared to unmodified PU, was reversed with the addition of blocking antibodies specific for CD47 and integrin alpha(v) and integrin beta(3). Similar results were observed with the addition of methyl-beta-cyclodextrin (MbetaCD), a known disruptor of the CD47 complex as well as of the membrane cholesterol content, to seeded BOEC or PU-Chol films. Reducing CD47 expression, via lentivirus transduced shRNA, decreased BOEC binding to PU-Chol by 50% compared to control groups. These data are the first demonstration of a role for the CD47 cholesterol-dependent signaling complex in BOEC attachment onto synthetic surfaces.


Subject(s)
Biocompatible Materials/chemistry , CD47 Antigen/metabolism , Cholesterol/chemistry , Endothelial Cells/cytology , Polyurethanes/chemistry , Animals , Biocompatible Materials/metabolism , CD47 Antigen/analysis , CD47 Antigen/genetics , Cell Adhesion , Cell Line , Cholesterol/metabolism , Down-Regulation , Endothelial Cells/metabolism , Humans , Integrin alphaVbeta3/metabolism , Polyurethanes/metabolism , Sheep
20.
J Biomed Mater Res A ; 94(3): 751-9, 2010 Sep 01.
Article in English | MEDLINE | ID: mdl-20306526

ABSTRACT

Oxidative degradation of the polyurethane elastomeric (PU) components greatly reduces the efficacy of PU-containing cardiovascular devices. Covalently appending the phenol-based antioxidant, 4-substituted 2,6-di-tert-butylphenol (DBP), to PU hard segments effectively reduced oxidative degradation of the PU in vivo and in vitro in prior studies by our group. In these experiments, we analyze the contribution of the tethering molecule to the antioxidant capabilities of the DBP-modified PU. Bromoalkylation chemistry was used to link DBP to the hard segment of the polyether PU, Tecothane, via our original linker (PU-DBP) or variants containing side chains with one (PU-C-DBP) or three (PU-3C-DBP) carbons. Two additional DBP variants were fabricated in which the DBP group was appended to the alkyl chain via an oxygen atom (PU-O-DBP) or an amide linkage in the middle of the tether (PU-NHCO-DBP). All DBP variant films and unmodified control films were subject to oxidative degradation via 15-day immersion in a solution of 20% H(2)O(2) + 0.1M CoCl(2). At the end of the oxidation protocol, films were analyzed for the presence of oxidation-related endpoints via scanning electron microscopy, contact angle measurements, and Fourier transformation infrared spectroscopy (FTIR). All DBP-containing variants resisted oxidation damage significantly better than the unmodified control PU. SEM analysis of oxidized PU-C-DBP and PU-O-DBP showed evidence of surface cracking, consistent with oxidative degradation of the PU surfaces. Similarly, there was a trend in increased ether crosslinking, a marker for oxidative degradation, in PU-C-DBP and PU-NHCO-DBP films. Consistent with these FTIR results, both PU-C-DBP and PU-NHCO-DBP had significant reductions in measured surface hydrophobicity as a result of oxidation. These data show for the first time that the choice of linker molecule significantly affects the efficiency of the linked phenolic antioxidant.


Subject(s)
Antioxidants/chemistry , Oxidation-Reduction , Phenols/chemistry , Polyurethanes/chemistry , Antioxidants/metabolism , Biocompatible Materials/chemistry , Biocompatible Materials/metabolism , Materials Testing , Molecular Structure , Phenols/metabolism , Polyurethanes/metabolism , Prostheses and Implants , Spectroscopy, Fourier Transform Infrared , Structure-Activity Relationship
SELECTION OF CITATIONS
SEARCH DETAIL
...