Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Talanta ; 140: 10-19, 2015 Aug 01.
Article in English | MEDLINE | ID: mdl-26048817

ABSTRACT

The gas phase ion chemistry for an ion mobility spectrometer (IMS) based explosive detector has been elucidated using tandem mass spectrometry. The IMS system, which is operated with hexachloroethane and isobutyramide reagent gases and an ion shutter type gating scheme, is connected to the atmospheric pressure interface of a triple quadrupole mass spectrometer (MS/MS). Product ion masses, daughter ion masses, and reduced mobility values for a collection of nitro, nitrate, and peroxide explosives measured with the IMS/MS/MS instrument are reported. The mass and mobility data together with targeted isotopic labeling experiments and information about sample composition and reaction environment are leveraged to propose molecular formulas, structures, and ionization pathways for the various product ions. The major product ions are identified as [DNT-H](-) for DNT, [TNT-H](-) for TNT, [RDX+Cl](-) and [RDX+NO2](-) for RDX, [HMX+Cl](-) and [HMX+NO2](-) for HMX, [NO3](-) for EGDN, [NG+Cl](-) and [NG+NO3](-) for NG, [PETN+Cl](-) and [PETN+NO3](-) for PETN, [HNO3+NO3](-) for NH4NO3, [NO2](-) for DMNB, [HMTD-NC3H6O3+H+Cl](-) and [HMTD+H-CH2O-H2O2](+) for HMTD, and [(CH3)3CO2](+) for TATP. In general, the product ions identified for the IMS system studied here are consistent with the product ions reported previously for an ion trap mobility spectrometer (ITMS) based explosive trace detector, which is operated with dichloromethane and ammonia reagent gases and an ion trap type gating scheme. Differences between the explosive trace detectors include the [NG+Cl](-) and [PETN+Cl](-) product ions being major ions in the IMS system compared to minor ions in the ITMS system as well as the major product ion for TATP being [(CH3)3CO2](+) for the IMS system and [(CH3)2CNH2](+) for the ITMS system.

2.
Talanta ; 99: 799-810, 2012 Sep 15.
Article in English | MEDLINE | ID: mdl-22967626

ABSTRACT

A commercial-off-the-shelf (COTS) ion trap mobility spectrometry (ITMS) based explosive trace detector (ETD) has been interfaced to a triple quadrupole mass spectrometer (MS/MS) for the purpose of characterizing the gas phase ion chemistry intrinsic to the ITMS instrument. The overall objective of the research is to develop a fundamental understanding of the gas phase ionization processes in the ITMS based ETD to facilitate the advancement of its operational effectiveness as well as guide the development of next generation ETDs. Product ion masses, daughter ion masses, and reduced mobility values measured by the ITMS/MS/MS configuration for a suite of nitro, nitrate, and peroxide containing explosives are reported. Molecular formulas, molecular structures, and ionization pathways for the various product ions are inferred using the mass and mobility data in conjunction with density functional theory. The predominant product ions are identified as follows: [TNT-H](-) for trinitrotoluene (TNT), [RDX+Cl](-) for cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX), [NO(3)](-) for ethylene glycol dinitrate (EGDN), [NG+NO(3)](-) for nitroglycerine (NG), [PETN+NO(3)](-) for pentaerythritol tetranitrate (PETN), [HNO(3)+NO(3)](-) for ammonium nitrate (NH(4)NO(3)), [HMTD-NC(3)H(6)O(3)+H+Cl](-) for hexamethylene triperoxide diamine (HMTD), and [(CH(3))(2)CNH(2)](+) for triacetone triperoxide (TATP). The predominant ionization pathways for the formation of the various product ions are determined to include proton abstraction, ion-molecule attachment, autoionization, first-order and multi-order thermolysis, and nucleophilic substitution. The ion trapping scheme in the reaction region of the ITMS instrument is shown to increase predominant ion intensities relative to the secondary ion intensities when compared to non-ion trap operation.

3.
Anal Chem ; 83(22): 8596-603, 2011 Nov 15.
Article in English | MEDLINE | ID: mdl-22017332

ABSTRACT

Hardware from a commercial-off-the-shelf (COTS) ion mobility spectrometry (IMS) based explosive trace detector (ETD) has been interfaced to an AB/SCIEX API 2000 triple quadrupole mass spectrometer. To interface the COTS IMS based ETD to the API 2000, the faraday plate of the IMS instrument and the curtain plate of the mass spectrometer were removed from their respective systems and replaced by a custom faraday plate, which was fabricated with a hole for passing the ion beam to the mass spectrometer, and a custom interface flange, which was designed to attach the IMS instrument onto the mass spectrometer. Additionally, the mass spectrometer was modified to increase the electric field strength and decrease the pressure in the differentially pumped interface, causing a decrease in the effect of collisional focusing and permitting a mobility spectrum to be measured using the mass spectrometer. The utility of the COTS-ETD/API 2000 configuration for the characterization of the gas phase ion chemistry of COTS-ETD equipment was established by obtaining mass and tandem mass spectra in the continuous ion flow and selected mobility monitoring operating modes and by obtaining mass-selected ion mobility spectra for the explosive standard 2,4,6 trinitrotoluene (TNT). This analysis confirmed that the product ion for TNT is [TNT - H](-), the predominant collision-induced dissociation pathway for [TNT- H](-) is the loss of NO and NO(2), and the reduced mobility value for [TNT - H](-) is 1.54 cm(2)V(-1) s(-1). Moreover, this analysis was attained for sample amounts of 1 ng and with a resolving power of 37. The objective of the research is to advance the operational effectiveness of COTS IMS based ETD equipment by developing a platform that can facilitate the understanding of the ion chemistry intrinsic to the equipment.


Subject(s)
Trinitrotoluene/analysis , Mass Spectrometry/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...