Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Med Phys ; 39(6Part12): 3747, 2012 Jun.
Article in English | MEDLINE | ID: mdl-28517812

ABSTRACT

PURPOSE: In a typical model of Radiation Oncology data flow, treatment plan is designed on treatment planning station (TPS) under the supervision of physician and physicist, and machine specific parameters are pushed to Record and Verify system (RV) for treatment data storage, where it stays available for daily uploads to treatment station. While various QA programs could be established to verify uncorrupted planning data storage and transfer, the ultimate goal is a daily confirmation of patient treatment parameters versus original treatment plan. METHODS: A new computer vision approach, RTcheck, is used to digitize loaded machine parameters directly from the screen of Varian Clinical Console every time before the beam is turned on by a therapist. The verification engine runs a check against the parameters automatically extracted from the printed postscript planning report (Pinnacle, Philips) prepared during planning stage and approved by physician. All important beam data, MUs, jaws position, beam energy, couch angle, and wedge specifiers are displayed side by side on the screen of RTcheck station. All field verifications are recorded to a log file, periodically reviewed by a physicist. RESULTS: In our clinical tests, the electronic verification of machine treatment parameters shortened patient 'on the table' time, as the manual therapist's 'time out' check before every beam on may take up to several minutes for patient treatments with multiple beams (more than 10). Our analysis of verification logs revealed several instances of a small X1 jaw position discrepancy of 0.1cm for jaw position range of 0 to -2cm. After jaw recalibration, the problem was eliminated. CONCLUSIONS: RTcheck is the end-to-end quality assurance approach to verify data flow from TPS to treatment machine for every patient treatment. Computer vision approach may help reduce human error factor, and shorten patient treatment time. CONFLICT OF INTEREST: S. Kriminski and I. Lysiuk: provisional patent application is submitted to United States Patent and Trademark Office.

2.
Proc SPIE Int Soc Opt Eng ; 71812009 Feb 25.
Article in English | MEDLINE | ID: mdl-24224074

ABSTRACT

A critical need has emerged for volumetric thermometry to visualize 3D temperature distributions in real time during deep hyperthermia treatments used as an adjuvant to radiation or chemotherapy for cancer. For the current effort, magnetic resonance thermal imaging (MRTI) is used to measure 2D temperature rise distributions in four cross sections of large extremity soft tissue sarcomas during hyperthermia treatments. Novel hardware and software techniques are described which improve the signal to noise ratio of MR images, minimize motion artifact from circulating coupling fluids, and provide accurate high resolution volumetric thermal dosimetry. For the first 10 extremity sarcoma patients, the mean difference between MRTI region of interest and adjacent interstitial point measurements during the period of steady state temperature was 0.85°C. With 1min temporal resolution of measurements in four image planes, this non-invasive MRTI approach has demonstrated its utility for accurate monitoring and realtime steering of heat into tumors at depth in the body.

SELECTION OF CITATIONS
SEARCH DETAIL
...