1.
Talanta ; 123: 179-85, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24725881

ABSTRACT

A stability-indicating capillary zone electrophoresis (CZE) method was validated for the analysis of recombinant human interleukin-11(rhIL-11) using rupatadine fumarate, as internal standard (IS). A fused-silica capillary, (50 µm i.d.; effective length, 40 cm) was used at 25°C; the applied voltage was 20 kV. The background electrolyte solution consisted of 50 mmol L(-1) sodium dihydrogen phosphate solution at pH 3.0. Injections were performed using a pressure mode at 50 mbar for 45 s, with detection by photodiode array detector set at 196 nm. Specificity and stability-indicating capability were established in degradation studies, which also showed that there was no interference of the excipients. The method was linear over the concentration range of 1.0-300 µg mL(-1) (r(2)=0.9992) and the limit of detection (LOD) and limit of quantitation (LOQ) were 0.2 µg mL(-1) and 1.0 µg mL(-1), respectively. The accuracy was 100.4% with bias lower than 1.1%. Moreover, the in vitro cytotoxicity test of the degraded products showed significant differences (p<0.05). The method was applied for the content/potency assessment of rhIL-11 in biopharmaceutical formulations, and the results were correlated to those of a validated reversed-phase LC method (RP-LC) and an TF-1 cell culture assay, showing non-significant differences (p>0.05). In addition the CZE and RP-LC methods were applied for the analysis of rhIL-11 in human plasma. Therefore, the proposed alternative method can be applied to monitor stability, to assure the batch-to-batch consistency and quality of the bulk and finished biotechnology-derived medicine.


Subject(s)
Chromatography, Reverse-Phase/methods , Electrophoresis, Capillary/methods , Interleukin-11/analysis , Recombinant Proteins/analysis , Animals , Biological Assay , Cell Line , Cell Line, Tumor , Cell Survival/drug effects , Drug Stability , Humans , Inhibitory Concentration 50 , Interleukin-11/blood , Interleukin-11/pharmacology , Protein Stability , Recombinant Proteins/pharmacology , Reproducibility of Results
2.
J AOAC Int ; 96(2): 324-30, 2013.
Article in English | MEDLINE | ID: mdl-23767357

ABSTRACT

A size-exclusion LC method was validated for the determination of interferon-a2a (rhlFN-alpha2a) in pharmaceutical formulations without interference from human serum albumin. Chromatographic separation was performed on a BioSep-SEC-S 2000 column (300 x 7.8 mm id). The mobile phase consisted of 0.001 M monobasic potassium phosphate, 0.008 M sodium phosphate dibasic; 0.2 M sodium chloride buffer, pH 7.4, run at a gradient flow rate and using photodiode array detection at 214 nm, was used. Chromatographic separation was achieved with a retention time of 17.2 min, and the analysis was linear over the concentration range of 1.98 to 198 microg/mL (r2 = 0.9996). The accuracy was 101.39%, with bias lower than 1.67%. The LOD and LOQ were 0.87 and 1.98 microg/mL, respectively. Moreover, method validation demonstrated acceptable results for precision and robustness. The method was applied to the assessment of rhlFN-alpha2a and related proteins in biopharmaceutical dosage forms, and the content/potencies were correlated to those given by a validated RP-LC method and an in vitro bioassay. It was concluded that use of the methods in conjunction allows a great improvement in monitoring stability and QC, thereby ensuring the therapeutic efficacy of the biotechnology-derived medicine.


Subject(s)
Chromatography, Liquid/methods , Interferon-alpha/chemistry , Cell Line, Tumor , Drug Stability , Humans , Reproducibility of Results , Sensitivity and Specificity
3.
Anal Sci ; 28(3): 215-20, 2012.
Article in English | MEDLINE | ID: mdl-22451359

ABSTRACT

A stability-indicating reversed-phase liquid chromatography (RP-LC) method was validated for the assessment of recombinant human interleukin-11 (rhIL-11), based on the ICH guidelines. The method was carried out on a Jupiter C(4) column (250 mm × 4.6 mm i.d.), maintained at 25°C. The mobile phase A consisted of 0.1% trifluoroacetic acid (TFA) and the mobile phase B was acetonitrile with 0.1% TFA, run at a flow rate of 1 mL/min, and using a photodiode array (PDA) detection at 214 nm. Separation was obtained with a retention time of 27.6 min, and was linear over the concentration range of 1-200 µg/mL (r(2) = 0.9995). Specificity was established in degradation studies, which also showed that there was no interference of the excipients. The accuracy was 100.22% with bias lower than 1.25%. Moreover, the in vitro cytotoxicity test of the degraded products showed non-significant differences (p > 0.05). The method was applied to the assessment of rhIL-11 and related proteins in biopharmaceutical dosage forms, and the results were correlated to those of a bioassay.


Subject(s)
Biological Assay , Chromatography, Reverse-Phase/methods , Interleukin-11/isolation & purification , Interleukin-11/pharmacology , Recombinant Proteins/isolation & purification , Recombinant Proteins/pharmacology , Animals , Cell Line , Cell Proliferation/drug effects , Humans , Interleukin-11/analysis , Interleukin-11/toxicity , Limit of Detection , Quality Control , Recombinant Proteins/analysis , Recombinant Proteins/toxicity