1.
Rev Sci Instrum ; 83(10): 10D505, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23130789

ABSTRACT

An in-vessel calibration light source (ICLS) has been implemented for remote use during extended shutdown periods of the Joint European Torus (JET). The ICLS facilitated the in situ calibration of optical diagnostics, which previously were performed when the diagnostics were removed from JET. Since the ICLS is used to calibrate diagnostics over the entire, exact optical path as used when plasma discharge data are measured, the ICLS calibration implicitly accounts for any vignetting losses in the JET vessel viewports in addition to the vacuum window transmission. At least ten diagnostic systems have benefited from the ICLS during the extended ITER-like wall shutdown of 2009-2011. Examples of the use of the ICLS in JET are given.


Subject(s)
Light , Magnetic Phenomena , Physics/instrumentation , Calibration , Plasma Gases/chemistry
2.
Rev Sci Instrum ; 83(10): 10D517, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23130791

ABSTRACT

In preparation for ITER, JET has been upgraded with a new ITER-like wall (ILW), whereby the main plasma facing components, previously of carbon, have been replaced by mainly Be in the main chamber and W in the divertor. As part of the many diagnostic enhancements, a new, survey, visible spectroscopy diagnostic has been installed for the characterization of the ILW. An array of eight lines-of-sight (LOS) view radially one of the two JET neutral beam shine through areas (W coated carbon fibre composite tiles) at the inner wall. In addition, one vertical LOS views the solid W tile at the outer divertor. The light emitted from the plasma is coupled to a series of compact overview spectrometers, with overall wavelength range of 380-960 nm and to one high resolution Echelle overview spectrometer covering the wavelength range 365-720 nm. The new survey diagnostic has been absolutely calibrated in situ by means of a radiometric light source placed inside the JET vessel in front of the whole optical path and operated by remote handling. The diagnostic is operated in every JET discharge, routinely monitoring photon fluxes from intrinsic and extrinsic impurities (e.g., Be, C, W, N, and Ne), molecules (e.g., BeD, D(2), ND) and main chamber and divertor recycling (typically Dα, Dß, and Dγ). The paper presents a technical description of the diagnostic and first measurements during JET discharges.

3.
Rev Sci Instrum ; 83(10): 10D536, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23130795

ABSTRACT

Enhancements to the JET poloidally scanning spectrometers are presented, which will aid the exploitation of the recently installed ITER-like wall in JET. They include the installation of visible filter∕photomultiplier tube assemblies and spectrometers and the replacement of large rotating mirrors in the JET vacuum with small oscillating mirrors outside. The upgrade has resulted in a more robust and reliable diagnostic than before, which is described. Drifts in the mirror angle reconstructed from quadrature encoder signals are found, a reference signal being required. The use of the small scanning mirrors necessitated the inclusion of focusing mirrors to maintain throughput into the vacuum ultraviolet spectrometers. The mirror design has taken account of the extreme sensitivity of the focusing to the grazing angle of incidence, an aspect of importance in the design of grazing incidence focusing components on future machines, such as ITER. The visible system has been absolutely calibrated using an in-vessel light source.

4.
Rev Sci Instrum ; 79(10): 10F530, 2008 Oct.
Article in English | MEDLINE | ID: mdl-19068537

ABSTRACT

An in-vessel calibration light source (ICLS) is proposed for use during extended shutdown periods of the Joint European Torus (JET). The ICLS is primarily a 12 in. integrating sphere (4 in. opening) with four lamps (of known radiance), which can be positioned inside the JET vacuum vessel via the remote handling arm during interventions in the JET operating schedule. This will facilitate the in situ calibration of optical diagnostics, which rely on absolute light intensity measurements currently made when the diagnostics are removed from JET. The ICLS could ultimately reduce/remove the mechanical stresses associated with the repositioning of diagnostics for calibration purposes. At least 10 diagnostic systems (approximately 20 diagnostic subsystems) could benefit from the ICLS; in some instances the ICLS provides the only viable absolute-calibration strategy. Moreover, the ICLS will be a broad-spectrum white light source, enabling intensity calibrations at all visible wavelengths. A secondary benefit of the ICLS is in its use as an illumination source for making measurements of the reflectance (over a broad spectral range and at multiple angles) from the tiles lining the JET vacuum vessel. During the ITER-like wall intervention new Be, C, and W tiles will be installed in JET and their reflectance measured. Measurements made in subsequent JET interventions will provide data on the effect of high-temperature plasma operation on the reflectance of these tiles.