ABSTRACT

OBJECTIVE: To assess prostate cancer (PCa) detection and prediction by combining the in-bore magnetic resonance imaging-guided transrectal targeted prostate biopsy (MRGB) with prostate-specific antigen (PSA) parameters and the Prostate Health Index (PHI) in case of negative 12-core standard biopsy. MATERIALS AND METHODS: A total of 112 men (2014-2016) underwent 3-T multiparametric magnetic resonance imaging and subsequent MRGB of Prostate Imaging-Reporting and Data System (PI-RADS) lesions 3-5. Ancillary PSA parameters (PSA ratio [%fPSA] and PSA density [PSAD]) and the PHI and PHI density (PHID) were recorded. With these parameters in combination with MRGB, PCa prediction was calculated. RESULTS: The most common lesions biopsied were PI-RADS 4 (66%), located in the peripheral zone (64%), in the middle (58%) and anterior (65%) sections of the prostate, and 13 mm (IQR 10-15) in size. PCa was found in 62 (55%) patients (28% Gleason score ≥7). PSAD (0.15 vs 0.21; P = .0051), %fPSA (16 vs 13; P = .0191), PHI (45 vs 69; P < .0001), PHID (0.7 vs 1.5; P < .0001), and prostate volume (56 mL vs 45 mL; P = .0073) were significantly different in patients with PCa and those without PCa. PHI and PHID were the strongest predictors of PCa with areas under the curve of 0.79 and 0.77, respectively. Using optimal thresholds of 59 and 0.79, PHI and PHID were 69% and 84% sensitive and 82% and62% specific for PCa, respectively. CONCLUSION: Following negative standard biopsy of the prostate, the MRGB achieved an overall PCa detection rate of 55% in patients with PI-RADS 3-5 lesions. By considering PHI and PHID, 82% and 62% of unnecessary biopsies could have been avoided, failing to detect 31% and 16% of cancers.


Subject(s)
Magnetic Resonance Imaging, Interventional , Prostate-Specific Antigen/blood , Prostate/pathology , Prostatic Neoplasms/blood , Prostatic Neoplasms/pathology , Aged , Biopsy, Large-Core Needle/methods , False Negative Reactions , Health Status Indicators , Humans , Image-Guided Biopsy , Male , Middle Aged , Predictive Value of Tests , Rectum , Retrospective Studies
2.
Urology ; 109: 184-189, 2017 Nov.
Article in English | MEDLINE | ID: mdl-28712889

ABSTRACT

OBJECTIVE: To investigate the efficacy and safety of the Adjustable Transobturator Male System (ATOMS) in men with stress urinary incontinence after transurethral resection of the prostate (TURP). MATERIALS AND METHODS: From a large international prospectively administrated ATOMS register, we identified 49 patients with an ATOMS device as a result of persistent stress urinary incontinence after TURP. For evaluation, the men were divided into standard transurethral resection of the prostate (sTURP) and palliative transurethral resection of the prostate (pTURP) in radiated patients. Baseline and follow-up measurements included continence parameters, urodynamics, quality-of-life surveys (Patient Global Impression-Improvement and International Consultation on Incontinence Questionnaire-Short Form), and pain ratings. The dry rate (0-1 security pad/<10 mL urine loss), the success rate (overall improvement), removals, complications, and treatment failures were recorded. A P value of <.05 was considered statistically significant. RESULTS: After a median of 34 and 22 months' follow-up and 2-3 adjustments, the sTURP and pTURP cohorts had 58% and 50% dry rates and 90% and 87% success rates. Hence, no improvement was seen in 10% and 13%. The removal rate was higher in pTURP (50% vs 10%, P = .0171) and infection was the most common side effect (50%) observed. Neither intraoperative nor Clavien-Dindo 4 and 5 adverse events were recorded. In sTURP and pTURP, the median daily pad count and the pad test improved significantly (all P <.001), and quality-of-life parameters shifted to a high satisfaction level (P <.001 and P = .001). Urodynamics remained unchanged and postoperative pain was not an issue. CONCLUSION: The ATOMS device shows promising treatment outcomes in patients after TURP and a similar efficacy as in postprostatectomy incontinence. There is no difference in continence outcome between sTURP and pTURP; however, a higher removal rate was found after pTURP, which may be important for patient counseling.


Subject(s)
Postoperative Complications/surgery , Suburethral Slings , Transurethral Resection of Prostate , Urinary Incontinence, Stress/surgery , Aged , Aged, 80 and over , Cross-Sectional Studies , Humans , Male , Retrospective Studies , Suburethral Slings/adverse effects , Treatment Outcome