Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Appl Crystallogr ; 51(Pt 3): 646-654, 2018 Jun 01.
Article in English | MEDLINE | ID: mdl-29896056

ABSTRACT

MARIA (magnetism reflectometer with high incident angle) is a world class vertical sample reflectometer dedicated to the investigation of thin films in the fields of magnetism, soft matter and biology. The elliptical vertically focusing guide allows one to measure small samples with a typical size of 1 × 1 cm very efficiently. The double-bounce polarizer and the in situ pumped 3He SEOP (spin-exchange optical pumping) neutron spin filter cell for analysing the polarization of the reflected neutron beam can be moved into the beam in seconds. The polarized flux of MARIA amounts to 5 × 107 n (s cm2)-1 at the sample position with a horizontally collimated beam of 3 mrad, a wavelength of λ = 4.5 Šand a wavelength resolution of Δλ/λ = 10%. In the non-polarized mode a flux of 1.2 × 108 n (s cm2)-1 is achieved in this configuration. MARIA is also capable of grazing-incidence small-angle neutron scattering measurements, using a pinhole collimation with two four-segment slits and an absorber that prevents the focusing of the elliptical guide in the vertical direction.

2.
J Vis Exp ; (118)2016 12 08.
Article in English | MEDLINE | ID: mdl-28060296

ABSTRACT

The KWS-2 SANS diffractometer is dedicated to the investigation of soft matter and biophysical systems covering a wide length scale, from nm to µm. The instrument is optimized for the exploration of the wide momentum transfer Q range between 1x10-4 and 0.5 Å-1 by combining classical pinhole, focusing (with lenses), and time-of-flight (with chopper) methods, while simultaneously providing high-neutron intensities with an adjustable resolution. Because of its ability to adjust the intensity and the resolution within wide limits during the experiment, combined with the possibility to equip specific sample environments and ancillary devices, the KWS-2 shows a high versatility in addressing the broad range of structural and morphological studies in the field. Equilibrium structures can be studied in static measurements, while dynamic and kinetic processes can be investigated over time scales between minutes to tens of milliseconds with time-resolved approaches. Typical systems that are investigated with the KWS-2 cover the range from complex, hierarchical systems that exhibit multiple structural levels (e.g., gels, networks, or macro-aggregates) to small and poorly-scattering systems (e.g., single polymers or proteins in solution). The recent upgrade of the detection system, which enables the detection of count rates in the MHz range, opens new opportunities to study even very small biological morphologies in buffer solution with weak scattering signals close to the buffer scattering level at high Q. In this paper, we provide a protocol to investigate samples with characteristic size levels spanning a wide length scale and exhibiting ordering in the mesoscale structure using KWS-2. We present in detail how to use the multiple working modes that are offered by the instrument and the level of performance that is achieved.


Subject(s)
Neutron Diffraction/methods , Gels/chemistry , Neutrons , Polymers/chemistry , Proteins/chemistry
3.
Rev Sci Instrum ; 83(7): 075109, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22852726

ABSTRACT

SPHERES is a third-generation neutron backscattering spectrometer, located at the 20 MW German neutron source FRM II and operated by the Jülich Centre for Neutron Science. It offers an energy resolution (fwhm) better than 0.65 µeV, a dynamic range of ± 31 µeV, and a signal-to-noise ratio of up to 1750:1.