Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 29
Filter
1.
ASAIO J ; 69(1): 122-126, 2023 01 01.
Article in English | MEDLINE | ID: mdl-35471245

ABSTRACT

Both overfeeding and underfeeding critically ill children are problematic. This prospective pilot study evaluated the resting energy expenditure in infants and children requiring extracorporeal membrane oxygenation (ECMO) support. An indirect calorimeter was used to measure oxygen consumption (VO 2 ) and carbon dioxide production (VCO 2 ) from the mechanical ventilator. Blood gases were used to determine VO 2 and VCO 2 from the ECMO circuit. Values from the mechanical ventilator and ECMO circuit were added, and the resting energy expenditure (REE) (Kcal/kg/day) was calculated. Measurements were obtained > 24 hours after ECMO support was initiated (day 2 of ECMO), 1 day before ECMO discontinuation or transfer, and 1 day after decannulation. Data were compared with the predicted energy expenditure. Seven patients aged 3 months to 13 years were included. The REE varied greatly both above and below predicted values, from 26 to 154 KCal/kg/day on day 2 of ECMO support. In patients with septic shock, the REE was > 300% above the predicted value on day 2 of ECMO. Before ECMO discontinuation, two of six (33%) children continued to have a REE > 110% of predicted. Three patients had measurements after decannulation, all with a REE < 90% of predicted. REE measurements can be obtained by indirect calorimetry in children receiving ECMO support. ECMO may not provide metabolic rest for all children as a wide variation in REE was observed. For optimal care, individual testing should be considered to match calories provided with the metabolic demand.


Subject(s)
Extracorporeal Membrane Oxygenation , Infant , Humans , Child , Pilot Projects , Prospective Studies , Carbon Dioxide/metabolism , Critical Illness , Energy Metabolism
2.
J Investig Med High Impact Case Rep ; 9: 23247096211034045, 2021.
Article in English | MEDLINE | ID: mdl-34293947

ABSTRACT

Supraventricular tachycardia is the most common tachyarrhythmia in pediatrics. Although postoperative junctional ectopic tachycardia (JET) is a known complication of congenital heart surgery that is typically transient, congenital JET is rare and requires aggressive treatment to maintain hemodynamic stability. We describe the case of a 3-month-old, previously healthy female who presented with heart failure and cardiogenic shock secondary to congenital JET for whom extracorporeal membrane oxygenation (ECMO) provided time for selection of effective therapy. Adenosine, cardioversion, and transesophageal pacing were unsuccessful, and her echocardiogram demonstrated bilateral atrial dilation and severe left ventricular systolic dysfunction. Approximately 8 hours after presentation, venous-arterial ECMO was commenced allowing for successful treatment with amiodarone. Her electrocardiogram demonstrated atrioventricular dissociation consistent with JET. She was successfully decannulated from ECMO after 6 days. Her discharge echocardiogram showed normal ventricular function, and she had no significant ECMO sequelae. This case demonstrates the value of early ECMO initiation for cardiovascular support in pediatric patients with a life-threatening arrhythmia and in cardiogenic shock. ECMO support can allow for full diagnostic and therapeutic decisions to effectively reverse the consequences of uncontrolled arrhythmias unrelated to surgical complications.


Subject(s)
Extracorporeal Membrane Oxygenation , Pediatrics , Tachycardia, Ectopic Junctional , Vascular Diseases , Child , Electrocardiography , Female , Humans , Infant , Tachycardia, Ectopic Junctional/therapy
3.
J Surg Res ; 263: 14-23, 2021 07.
Article in English | MEDLINE | ID: mdl-33621745

ABSTRACT

BACKGROUND: Neonates receiving extracorporeal life support (ECLS) for congenital diaphragmatic hernia (CDH) require prolonged support compared with neonates with other forms of respiratory failure. Hemolysis is a complication that can be seen during ECLS and can lead to renal failure and potentially to worse outcomes. The purpose of this study was to identify risk factors for the development of hemolysis in CDH patients treated with ECLS. METHODS: The Extracorporeal Life Support Organization database was used to identify infants with CDH (2000-2015). The primary outcome was hemolysis (plasma-free hemoglobin >50 mg/dL). Potentially associated variables were identified in the data set. Descriptive statistics and a series of nested multivariable logistic regression models were used to identify associations between hemolysis and demographic, pre-ECLS, and on-ECLS factors. RESULTS: There were 4576 infants with a mortality of 52.5%. The overall mean rate of hemolysis was 10.5% during the study period. In earlier years (2000-2005), the hemolysis rates were 6.3% and 52.7% for roller versus centrifugal pumps, whereas in later years (2010-2015), they were 2.9% and 26.5%, respectively. The fully adjusted model demonstrated that the use of centrifugal pumps was a strong predictor of hemolysis (odds ratio: 6.67, 95% confidence interval: 5.14-8.67). In addition, other risk factors for hemolysis included low 5-min Apgar score, on-ECLS complications (renal, metabolic, and cardiovascular), and duration of ECLS. CONCLUSIONS: In our cohort of CDH patients receiving ECLS over 15 y, the use of centrifugal pumps increased over time, along with the rate of hemolysis. Patient- and treatment-level risk factors were identified contributing to the development of hemolysis.


Subject(s)
Extracorporeal Membrane Oxygenation/adverse effects , Hemolysis , Hernias, Diaphragmatic, Congenital/surgery , Postoperative Complications/epidemiology , Apgar Score , Cohort Studies , Extracorporeal Membrane Oxygenation/instrumentation , Extracorporeal Membrane Oxygenation/mortality , Female , Hemoglobins/analysis , Hernias, Diaphragmatic, Congenital/mortality , Hospital Mortality , Humans , Infant, Newborn , Male , Postoperative Complications/etiology , Risk Factors , Time Factors
4.
ASAIO J ; 66(7): 707-721, 2020 Jul.
Article in English | MEDLINE | ID: mdl-32604322

ABSTRACT

Disclaimer: The Extracorporeal Life Support Organization (ELSO) Coronavirus Disease 2019 (COVID-19) Guidelines have been developed to assist existing extracorporeal membrane oxygenation (ECMO) centers to prepare and plan provision of ECMO during the ongoing pandemic. The recommendations have been put together by a team of interdisciplinary ECMO providers from around the world. Recommendations are based on available evidence, existing best practice guidelines, ethical principles, and expert opinion. This is a living document and will be regularly updated when new information becomes available. ELSO is not liable for the accuracy or completeness of the information in this document. These guidelines are not meant to replace sound clinical judgment or specialist consultation but rather to strengthen provision and clinical management of ECMO specifically, in the context of the COVID-19 pandemic.


Subject(s)
Betacoronavirus , Consensus , Coronavirus Infections/therapy , Extracorporeal Membrane Oxygenation , Pneumonia, Viral/therapy , Practice Guidelines as Topic , COVID-19 , Humans , Pandemics , SARS-CoV-2
6.
J Surg Res ; 249: 67-73, 2020 05.
Article in English | MEDLINE | ID: mdl-31926398

ABSTRACT

BACKGROUND: Malnutrition in critically ill patients is common in neonates and children, including those that receive extracorporeal life support (ECLS). We hypothesize that nutritional adequacy is highly variable, overall nutritional adequacy is poor, and enteral nutrition is underutilized in this population. MATERIALS AND METHODS: A retrospective study of neonates and children (age<18 y) receiving ECLS at 5 centers from 2012 to 2014 was performed. Demographic, clinical, and outcome data were analyzed. Continuous variables are presented as median [IQR]. Adequate nutrition was defined as meeting 66% of daily caloric goals during ECLS support. RESULTS: Two hundred and eighty three patients received ECLS; the median age was 12 d [3 d, 16.4 y] and 47% were male. ECLS categories were neonatal pulmonary 33.9%, neonatal cardiac 25.1%, pediatric pulmonary 17.7%, and pediatric cardiac 23.3%. The predominant mode was venoarterial (70%). Mortality was 41%. Pre-ECLS enteral and parenteral nutrition was present in 80% and 71.5% of patients, respectively. The median percentage days of adequate caloric and protein nutrition were 50% [0, 78] and 67% [22, 86], respectively. The median percentage days with adequate caloric and protein nutrition by the enteral route alone was 22% [0, 65] and 0 [0, 50], respectively. Gastrointestinal complications occurred in 19.7% of patients including hemorrhage (4.2%), enterocolitis (2.5%), intra-abdominal hypertension or compartment syndrome (0.7%), and perforation (0.4%). CONCLUSIONS: Although nutritional delivery during ECLS is adequate, the use of enteral nutrition is low despite relatively infrequent observed gastrointestinal complications.


Subject(s)
Critical Illness/therapy , Enteral Nutrition/statistics & numerical data , Extracorporeal Membrane Oxygenation , Malnutrition/therapy , Parenteral Nutrition/statistics & numerical data , Practice Patterns, Physicians'/statistics & numerical data , Adolescent , Child , Child, Preschool , Critical Illness/mortality , Energy Intake/physiology , Enteral Nutrition/adverse effects , Female , Gastrointestinal Diseases/epidemiology , Gastrointestinal Diseases/etiology , Humans , Infant , Infant, Newborn , Male , Malnutrition/etiology , Malnutrition/physiopathology , Nutritional Status/physiology , Retrospective Studies , Treatment Outcome
8.
Perfusion ; 33(1_suppl): 71-79, 2018 05.
Article in English | MEDLINE | ID: mdl-29788843

ABSTRACT

PURPOSE: With the exception of neonatal respiratory failure, most centers are now using centrifugal over roller-type pumps for the delivery of extracorporeal membrane oxygenation (ECMO). Evidence supporting the use of centrifugal pumps specifically in infants with congenital diaphragmatic hernia (CDH) remains lacking. We hypothesized that the use of centrifugal pumps in infants with CDH would not affect mortality or rates of severe neurologic injury (SNI). METHODS: Infants with CDH were identified within the ELSO registry (2000-2016). Patients were then divided into those undergoing ECMO with rollertype pumps or centrifugal pumps. Patients were matched based on propensity score (PS) for the ECMO pump type based on pre-ECMO covariates. This was done for all infants and separately for each ECMO mode, venovenous (VV) and venoarterial (VA) ECMO. RESULTS: We identified 4,367 infants who were treated with either roller or centrifugal pumps from 2000-2016. There was no difference in mortality or SNI between the two pump types in any of the groups (all infants, VA-ECMO infants, VV-ECMO infants). However, there was at least a six-fold increase in the odds of hemolysis for centrifugal pumps in all groups: all infants (odds ratio [OR] 6.99, p<0.001), VA-ECMO infants (OR 8.11, p<0.001 and VV-ECMO infants (OR 9.66, p<0.001). CONCLUSION: For neonates with CDH requiring ECMO, there is no survival advantage or difference in severe neurologic injury between those receiving roller or centrifugal pump ECMO. However, there is a significant increase in red blood cell hemolysis associated with centrifugal ECMO support.


Subject(s)
Extracorporeal Membrane Oxygenation/adverse effects , Hernias, Diaphragmatic, Congenital/therapy , Extracorporeal Membrane Oxygenation/methods , Female , Hemolysis , Hernias, Diaphragmatic, Congenital/pathology , Humans , Infant, Newborn , Male , Treatment Outcome
9.
Pediatr Blood Cancer ; 65(9): e27225, 2018 09.
Article in English | MEDLINE | ID: mdl-29781569

ABSTRACT

Superior vena cava syndrome (SVCS) results in vascular, respiratory, and neurologic compromise. A systematic search was conducted to determine the prevalence of pediatric SVCS subtypes and identify clinical characteristics/treatment strategies that may influence overall outcomes. Data from 101 case reports/case series (142 patients) were analyzed. Morbidity (30%), mortality (18%), and acute complications (55%) were assessed as outcomes. Thrombosis was present in 36%, with multi-modal anticoagulation showing improved outcome by >50% (P = 0.004). Infant age (P = 0.04), lack of collaterals (P = 0.007), acute complications (P = 0.005), and clinical presentation may have prognostic utility that could influence clinical decisions and surveillance practices in pediatric SVCS.


Subject(s)
Superior Vena Cava Syndrome , Adolescent , Age of Onset , Anticoagulants/therapeutic use , Catheterization, Central Venous/adverse effects , Child , Child, Preschool , Evidence-Based Medicine , Heart Defects, Congenital/complications , Hematologic Neoplasms/complications , Humans , Infant , Infant, Newborn , Prevalence , Prognosis , Risk Factors , Stents , Superior Vena Cava Syndrome/classification , Superior Vena Cava Syndrome/epidemiology , Superior Vena Cava Syndrome/etiology , Superior Vena Cava Syndrome/therapy , Thrombophilia/complications , Treatment Outcome , Vascular Surgical Procedures
10.
Surg Innov ; 23(5): 511-4, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27357105

ABSTRACT

Purpose To evaluate effectiveness of a novel hemostatic dissection tool in patients with congenital heart disease undergoing redo pericardiac dissections. Description This dissection tool employs ferromagnetic energy to cut and coagulate. The unit passes no electric current through the patient, thus eliminating cautery-induced dysrhythmias and electrical interference. Ferromagnetic dissection is precise and reduces thermal injury spread by as much as 90%. Evaluation We case matched 22 patients undergoing reoperation for congenital heart surgery by weight/operation. Group 1 used the ferromagnetic tool, and Group 2 used conventional monopolar cautery for pericardiac dissection. For groups 1 and 2, the mean weight was 27.7 and 28.4, respectively (P = .87). Time (minutes) from skin incision to cardiopulmonary bypass was 71 versus 72 (P = .44), cardiopulmonary bypass (minutes) was 75.6 versus 73.6 (P = .42), total operative time (minutes) was 193 versus 201 (P = .34). Chest tube output/kilogram in first 6 and first 24 hours was 0.4 versus 1.3 (P = .02) and 0.8 versus 2.4 (P = .01) for groups 1 and 2, respectively. Re-exploration for bleeding was 0% versus 9% (P = .07). There was no mortality. Conclusion The ferromagnetic dissection system appears safe and efficacious. Bleeding was significantly decreased and the need for re-exploration reduced.


Subject(s)
Blood Loss, Surgical/prevention & control , Cardiac Surgical Procedures/adverse effects , Dissection/instrumentation , Heart Defects, Congenital/surgery , Magnets , Reoperation/methods , Adult , Biopsy, Needle , Cardiac Surgical Procedures/methods , Cohort Studies , Dissection/methods , Female , Heart Defects, Congenital/diagnostic imaging , Humans , Immunohistochemistry , Male , Middle Aged , Operative Time , Patient Safety , Reoperation/instrumentation , Retrospective Studies
11.
Tex Heart Inst J ; 43(3): 227-31, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27303238

ABSTRACT

A 4-year-old boy had a 15-mm atrial septal defect repaired percutaneously with use of an Amplatzer Septal Occluder. At age 16 years, he presented with a week's history of fever, chills, dyspnea, fatigue, and malaise. Cultures grew methicillin-sensitive Staphylococcus aureus. A transesophageal echocardiogram showed a 1.25 × 1.5-cm pedunculated mass on the left aspect of the atrial septum just superior to the mitral valve, and a smaller vegetation on the right inferior medial aspect of the septum. At surgery, visual examination of both sides of the septum revealed granulation tissue, the pedunculated mass, the small vegetation, and exposed metal wires that suggested incomplete endothelialization of the occluder. We removed the occluder and patched the septal defect. The patient returned to full activity after 4 months and was asymptomatic 3 years postoperatively. Our report reinforces the need for further investigation into prosthetic device endothelialization, endocarditis prophylaxis, and recommended levels of physical activity in patients whose devices might be incompletely endothelialized. In addition to reporting our patient's case, we review the medical literature on this topic.


Subject(s)
Endocarditis, Bacterial/etiology , Forecasting , Heart Septal Defects, Atrial/surgery , Prosthesis-Related Infections/etiology , Septal Occluder Device/adverse effects , Staphylococcal Infections/etiology , Staphylococcus aureus/isolation & purification , Adolescent , Anti-Bacterial Agents/therapeutic use , Cardiac Surgical Procedures/methods , Device Removal , Echocardiography, Transesophageal , Endocarditis, Bacterial/diagnosis , Endocarditis, Bacterial/therapy , Follow-Up Studies , Heart Septal Defects, Atrial/diagnosis , Humans , Male , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/therapy , Reoperation , Staphylococcal Infections/diagnosis , Staphylococcal Infections/therapy
12.
Pacing Clin Electrophysiol ; 39(5): 471-7, 2016 May.
Article in English | MEDLINE | ID: mdl-26920816

ABSTRACT

BACKGROUND: To compare the pacing parameters of unipolar versus bipolar temporary ventricular epicardial pacing leads. DESIGN: Prospective Randomized Unblinded Controlled Study. PATIENTS AND METHODS: Fifty patients undergoing surgery for congenital heart disease who were anticipated to require temporary ventricular pacing leads were recruited preoperatively: 25 patients were randomized to receive unipolar temporary ventricular epicardial pacing leads; the remaining 25 were randomized to receive bipolar temporary ventricular epicardial leads. The baseline characteristics of the groups were similar. The pacing parameters were measured daily for up to first seven postoperative days (PODs) with the day of surgery recorded as POD 0. RESULTS: On the day of insertion, the mean pacing and sensing thresholds were similar for both unipolar and bipolar leads. Thresholds progressively deteriorated with each subsequent POD. By POD 4, the mean ± standard deviation pacing threshold of ventricular bipolar lead was 2.87 ± 0.37 mA compared with 5.6 ± 0.85 mA for the unipolar leads (P = 0.005). The decrease in sensing threshold of the unipolar ventricular pacing leads was significantly more than that of bipolar leads (by POD 5, 5.7 ± 2.64 vs 10.33 ± 2.8, P = 0.01). CONCLUSIONS: Our study shows that the bipolar leads (Medtronic 6495, Medtronic Inc., Minneapolis, MN, USA) have superior sensing and pacing thresholds in the ventricular position in patients undergoing surgery for congenital heart disease when compared to the unipolar leads (Medical Concepts Europe VF608ABB, Medical Concepts Europe Inc., Buffalo, NY, USA).


Subject(s)
Cardiac Pacing, Artificial/methods , Heart Defects, Congenital/therapy , Pericardium , Electrodes , Female , Humans , Male , Prospective Studies , Time Factors
13.
Pediatr Crit Care Med ; 13(5): 529-34, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22596064

ABSTRACT

OBJECTIVE: Near-infrared spectroscopy correlation with low cardiac output has not been validated. Our objective was to determine role of splanchnic and/or renal oxygenation monitoring using near-infrared spectroscopy for detection of low cardiac output in children after surgery for congenital heart defects. DESIGN: Prospective observational study. SETTING: Pediatric intensive care unit of a tertiary care teaching hospital. PATIENTS: Children admitted to the pediatric intensive care unit after surgery for congenital heart defects. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: We hypothesized that splanchnic and/or renal hypoxemia detected by near-infrared spectroscopy is a marker of low cardiac output after pediatric cardiac surgery. Patients admitted after cardiac surgery to the pediatric intensive care unit over a 10-month period underwent serial splanchnic and renal near-infrared spectroscopy measurements until extubation. Baseline near-infrared spectroscopy values were recorded in the first postoperative hour. A near-infrared spectroscopy event was a priori defined as ≥20% drop in splanchnic and/or renal oxygen saturation from baseline during any hour of the study. Low cardiac output was defined as metabolic acidosis (pH <7.25, lactate >2 mmol/L, or base excess ≤-5), oliguria (urine output <1 mL/kg/hr), or escalation of inotropic support. Receiver operating characteristic analysis was performed using near-infrared spectroscopy event as a diagnostic test for low cardiac output. Twenty children were enrolled: median age was 5 months; median Risk Adjustment for Congenital Heart Surgery category was 3 (1-6); median bypass and cross-clamp times were 120 mins (45-300 mins) and 88 mins (17-157 mins), respectively. Thirty-one episodes of low cardiac output and 273 near-infrared spectroscopy events were observed in 17 patients. The sensitivity and specificity of a near-infrared spectroscopy event as an indicator of low cardiac output were 48% (30%-66%) and 67% (64%-70%), respectively. On receiver operating characteristic analysis, neither splanchnic nor renal near-infrared spectroscopy event had a significant area under the curve for prediction of low cardiac output (area under the curve: splanchnic 0.45 [95% confidence interval 0.30-0.60], renal 0.51 [95% confidence interval 0.37-0.65]). CONCLUSIONS: Splanchnic and/or renal hypoxemia as detected by near-infrared spectroscopy may not be an accurate indicator of low cardiac output after surgery for congenital heart defects.


Subject(s)
Cardiac Output, Low/diagnosis , Hypoxia/diagnosis , Oxygen/blood , Postoperative Complications/diagnosis , Spectroscopy, Near-Infrared , Acidosis/blood , Acidosis/diagnosis , Adolescent , Area Under Curve , Cardiac Output, Low/blood , Cardiotonic Agents/administration & dosage , Child , Child, Preschool , Confidence Intervals , Female , Heart Defects, Congenital/surgery , Humans , Hypoxia/blood , Infant , Infant, Newborn , Male , Postoperative Complications/blood , Predictive Value of Tests , Prospective Studies , ROC Curve , Renal Circulation , Splanchnic Circulation
15.
Pediatr Cardiol ; 31(8): 1249-51, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20838992

ABSTRACT

Ventricular noncompaction is a rare but well-documented cause of cardiomyopathy. This report presents a case of ventricular noncompaction diagnosed late in end-stage cardiac failure and malignant ventricular arrhythmia, which required an Abiomed biventricular assist device as a bridge to transplantation.


Subject(s)
Cardiomyopathies/surgery , Heart Transplantation , Heart-Assist Devices , Isolated Noncompaction of the Ventricular Myocardium/diagnosis , Tachycardia, Ventricular/surgery , Adolescent , Cardiac Catheterization , Cardiomyopathies/etiology , Diagnosis, Differential , Echocardiography , Humans , Isolated Noncompaction of the Ventricular Myocardium/complications , Male , Tachycardia, Ventricular/etiology
16.
World J Surg ; 34(4): 658-68, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20091166

ABSTRACT

Tetralogy of Fallot (TOF) is a cyanotic congenital cardiac defect that was first described by Stenson in 1672 and later named for Fallot, who in 1888 described it as a single pathological process responsible for (1) pulmonary outflow tract obstruction, (2) ventricular septal defect (VSD), (3) overriding aortic root, and (4) right ventricular hypertrophy. The surgical history of TOF began with the development of the systemic to pulmonary artery shunt (BT shunt) by Blalock, Taussig, and Thomas in 1944. Ten years later complete repair of TOF was performed by Lillehei using cross-circulation and by Kirklin with a primitive cardiopulmonary bypass circuit. Notable contributions by several other surgeons including Bahnson, Ebert, Malm, Trusler, Barratt-Boyes, and Castaneda would lead us into the modern era of surgery. Today, complete repair of TOF is performed before six months of age with low mortality (<2%). In select cases a modified version of the BT shunt is still performed as the initial procedure. Long-term survival rates are excellent (85%-90%). Adult survivors with TOF are an ever-increasing population and may require reintervention, surgically or catheter based. Promising future innovations include percutaneous pulmonary valve replacement, tissue-engineered autologous valves and conduits, and genetic manipulation. This article presents a review of TOF, including the history of surgical treatment, present-day approaches, and long-term outcomes.


Subject(s)
Cardiac Surgical Procedures/history , Tetralogy of Fallot/history , Tetralogy of Fallot/surgery , Age Factors , History, 20th Century , History, 21st Century , Humans
17.
J Thorac Cardiovasc Surg ; 136(6): 1422-8, 2008 Dec.
Article in English | MEDLINE | ID: mdl-19114184

ABSTRACT

OBJECTIVE: To explore the impact of human factors on intraoperative adverse events and compensation mechanisms in pediatric cardiac surgery. METHODS: Prospective observations of pediatric cardiac surgical procedures were conducted. Patient complexity scores were calculated and outcomes recorded. The process of care was divided into epochs. Events were extracted and coded into compensated or uncompensated major and minor adverse events. Linear regression and analysis of variance were used to analyze the relationships between epochs, complexity, adverse events, and outcome. Patient-specific and procedure-specific variables were tested in a forward stepwise logistic regression as predictors of cases with 1 or more major adverse events. RESULTS: One hundred two patients undergoing pediatric cardiac surgery were observed. An average of 1.2 (range 0-6) major adverse events occurred per case. The most common type of major adverse event was cardiovascular, and most occurred during the surgery/postbypass epoch. Cognitive compensation was the most common compensation mechanism for major adverse events. An average of 15.3 minor adverse events occurred per case. Minor adverse events occurred frequently during the surgery/bypass epoch and related to communication and coordination failures. Higher case complexity, longer surgery duration, and higher number of major adverse events per patient correlated with death compared with other outcome groups (P < .01). Case complexity (P < .01) and surgery duration (P < .05) were both significant predictors of major adverse events. CONCLUSIONS: Pediatric cardiac surgery is an ideal model to study the coordinated efforts of team members in a complex organizational structure. Adverse events occurred routinely during pediatric cardiac surgery and were mostly compensated. Case complexity was a significant predictor of major adverse events. The number of major adverse events per patient correlated with clinical outcomes.


Subject(s)
Cardiac Surgical Procedures/adverse effects , Heart Defects, Congenital/surgery , Intraoperative Complications/etiology , Adolescent , Child , Child, Preschool , Humans , Infant , Infant, Newborn , Intensive Care Units/organization & administration , Operating Rooms/organization & administration , Patient Care Team/organization & administration , Prospective Studies , Risk Assessment , Treatment Outcome
18.
Heart Lung ; 37(6): 479-80, 2008.
Article in English | MEDLINE | ID: mdl-18992632
19.
ASAIO J ; 54(5): 554-5, 2008.
Article in English | MEDLINE | ID: mdl-18812754

ABSTRACT

Neonatal entero-viral sepsis is a rare but fulminant infection with multisystem involvement, often presenting with hepatitis, meningo-encephalitis, disseminated intravascular coagulation (DIC), and myocarditis. Neonatal myocarditis often proves fatal. We report here a case of neonatal enteroviral myocarditis with multisystem organ failure and ischemic cardiomyopathy that was managed medically.


Subject(s)
Calcinosis/pathology , Cardiomyopathies/pathology , Enterovirus Infections , Sepsis , Calcinosis/diagnostic imaging , Cardiomegaly/diagnostic imaging , Cardiomyopathies/diagnostic imaging , Cardiotonic Agents/therapeutic use , Diuretics/therapeutic use , Enterovirus Infections/diagnosis , Enterovirus Infections/therapy , Humans , Infant, Newborn , Infant, Newborn, Diseases/diagnosis , Infant, Newborn, Diseases/therapy , Length of Stay , Male , Radiography , Respiration, Artificial , Sepsis/diagnosis , Sepsis/therapy , Sepsis/virology , Treatment Outcome , Ultrasonography
SELECTION OF CITATIONS
SEARCH DETAIL
...