Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Head Neck ; 41(1): 170-176, 2019 01.
Article in English | MEDLINE | ID: mdl-30548894

ABSTRACT

OBJECTIVES: To evaluate and compare the diagnostic potential of 18 F-fluorodeoxyglucose positron emission tomography/magnetic resonance imaging (18 FDG-PET/MRI) and MRI for recurrence diagnostics after primary therapy in patients with adenoid cystic carcinoma (ACC). METHODS: A total of 32 dedicated head and neck 18 F-FDG PET/MRI datasets were included in this analysis. MRI and 18 F-FDG PET/MRI datasets were analyzed in separate sessions by two readers for tumor recurrence or metastases. RESULTS: Lesion-based sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy were 96%, 84%, 90%, 93%, and 91% for 18 F-FDG PET/MRI and 77%, 94%, 95%, 73%, and 84% for MRI, resulting in a significantly higher diagnostic accuracy of 18 F-FDG PET/MRI compared to MRI (P < .005). CONCLUSION: 18 F-FDG PET/MRI is superior to MRI in detecting local recurrence and metastases in patients with ACC of the head and neck. Especially concerning its negative predictive value, 18 F-FDG PET/MRI outperforms MRI.


Subject(s)
Carcinoma, Adenoid Cystic/diagnostic imaging , Head and Neck Neoplasms/diagnostic imaging , Magnetic Resonance Imaging , Neoplasm Recurrence, Local/diagnostic imaging , Positron-Emission Tomography , Datasets as Topic , Fluorodeoxyglucose F18 , Humans , Lymphatic Metastasis/diagnostic imaging , Predictive Value of Tests , Radiopharmaceuticals , Sensitivity and Specificity
2.
PLoS One ; 13(10): e0206573, 2018.
Article in English | MEDLINE | ID: mdl-30376583

ABSTRACT

PURPOSE: The trend towards faster acquisition protocols in whole-body positron emission tomography/magnetic resonance (PET/MR) arises the question of whether short PET data acquisition protocols in a whole-body multi-station context allow for reduced PET acquisition times while providing adequate PET image quality and accurate quantification parameters. The study goal is to investigate how reducing PET acquisition times affects PET image quality and quantification in whole-body PET/MR in patients with oncologic findings. METHODS: Fifty-one patients with different oncologic findings underwent a clinical whole-body 18F-Fluorodeoxyglucose PET/MR examination. PET data was reconstructed with 4, 3, 2, and 1 min/bed time intervals for each patient to simulate the effect of reduced PET acquisition times. The 4-minute PET reconstructions served as reference standard. All whole-body PET data sets were analyzed regarding image quality, lesion detectability, PET quantification and standardized uptake values. RESULTS: A total of 91 lesions were detected in the 4-minute PET reconstructions. The same number of congruent lesions was also noticed in the 3 and 2 minutes-per-bed (mpb) reconstructed images. A total of 2 lesions in 2 patients was not detected in the 1 minute PET data reconstructions due to poor image quality. Image noise in the blood pool increased from 22.2% (4 mpb) to 42.1% (1 mpb). Signal-to-noise ratio declined with shorter timeframes from 13.1 (4 mpb) to 9.3 (1 mpb). SUVmean and SUVmax showed no significant changes between 4 and 1 mpb reconstructed timeframes. CONCLUSIONS: Reconstruction of PET data with different time intervals has shown that 2 minutes acquisition time per bed position instead of 4 minutes is sufficient to provide accurate lesion detection and adequate image quality in a clinical setting, despite the trends to lower image quality with shorter PET acquisition times. This provides latitude for potential reduction of PET acquisition times in fast PET/MR whole-body examinations.


Subject(s)
Magnetic Resonance Imaging/methods , Positron-Emission Tomography/methods , Adolescent , Aged , Aged, 80 and over , Child , Female , Fluorodeoxyglucose F18/administration & dosage , Humans , Image Processing, Computer-Assisted/methods , Multimodal Imaging/methods , Radiopharmaceuticals/administration & dosage , Signal-To-Noise Ratio , Time Factors , Young Adult
3.
EJNMMI Phys ; 5(1): 13, 2018 Jul 19.
Article in English | MEDLINE | ID: mdl-30022353

ABSTRACT

BACKGROUND: In patients with differentiated thyroid cancer (DTC), serial 124I PET/CT imaging is, for instance, used to assess the absorbed (radiation) dose to lesions. Frequently, the lesions are located in the neck and they are close to or surrounded by different tissue types. In contrast to PET/CT, MR-based attenuation correction in PET/MR may be therefore challenging in the neck region. The aim of this retrospective study was to assess the quantitative performance of 124I PET/MRI of neck lesions by comparing the MR-based and CT-based 124I activity concentrations (ACs). Sixteen DTC patients underwent PET/CT scans at 24 and 120 h after administration of about 25 MBq 124I. Approximately 1 h before or after PET/CT examination, each patient additionally received a 24-h PET/MR scan and sometimes a 120-h PET/MR scan. PET images were reconstructed using the respective attenuation correction approach. Appropriate reconstruction parameters and corrections were used to harmonize the reconstructed PET images to provide, for instance, similar spatial resolution. For each lesion, two types of ACs were ascertained: the maximum AC (max-AC) and an average AC (avg-AC). The avg-AC is the average activity concentration obtained within a spherical volume of interest with a diameter of 7 mm, equaling the PET scanner resolution. For each type of AC, the percentage AC difference between MR-based and CT-based ACs was determined and Lin's concordance correlation analysis was applied. Quantitative performance was considered acceptable if the standard deviation was ± 25% (precision), and the mean value was within ± 10% (accuracy). RESULTS: The avg-ACs (max-ACs within parentheses) of 74 lesions ranged from 0.20 (0.33) to 657 (733) kBq/mL. Excluding two lesions with ACs of approximately 1 kBq/mL, the mean (median) ± standard deviation (range) was - 4% (- 5%) ± 14% (- 28 to 29%) for the avg-AC and - 9% (- 11%) ± 14% (- 33 to 33%) for the max-AC. Lin's concordance correlation coefficients were ≥ 0.97, indicating substantial AC agreement. CONCLUSIONS: Quantification of lesions in the neck region using 124I PET/MR showed acceptable quantitation performance to 124I PET/CT for AC above 1 kBq/mL. The PET/MRI-based 124I ACs in the neck region can be therefore reliably used in pre-therapy dosimetry planning.

4.
Eur J Nucl Med Mol Imaging ; 45(12): 2093-2102, 2018 11.
Article in English | MEDLINE | ID: mdl-29876618

ABSTRACT

PURPOSE: To compare the sensitivity and specificity of 18F-fluordesoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT), 18F-FDG PET/magnetic resonance (18F-FDG PET/MR) and 18F-FDG PET/MR including diffusion weighted imaging (DWI) in the detection of sentinel lymph node metastases in patients suffering from malignant melanoma. MATERIAL & METHODS: Fifty-two patients with malignant melanoma (female: n = 30, male: n = 22, mean age 50.5 ± 16.0 years, mean tumor thickness 2.28 ± 1.97 mm) who underwent 18F-FDG PET/CT and subsequent PET/MR & DWI for distant metastasis staging were included in this retrospective study. After hybrid imaging, lymphoscintigraphy including single photon emission computed tomography/CT (SPECT/CT) was performed to identify the sentinel lymph node prior to sentinel lymph node biopsy (SLNB). In a total of 87 sentinel lymph nodes in 64 lymph node basins visible on SPECT/CT, 17 lymph node metastases were detected by histopathology. In separate sessions PET/CT, PET/MR, and PET/MR & DWI were assessed for sentinel lymph node metastases by two independent readers. Discrepant results were resolved in a consensus reading. Sensitivities, specificities, positive predictive values and negative predictive values were calculated with histopathology following SPECT/CT guided SLNB as a reference standard. RESULTS: Compared with histopathology, lymph nodes were true positive in three cases, true negative in 65 cases, false positive in three cases and false negative in 14 cases in PET/CT. PET/MR was true positive in four cases, true negative in 63 cases, false positive in two cases and false negative in 13 cases. Hence, we observed a sensitivity, specificity, positive predictive value and negative predictive value of 17.7, 95.6, 50.0 and 82.3% for PET/CT and 23.5, 96.9, 66.7 and 82.3% for PET/MR. In DWI, 56 sentinel lymph node basins could be analyzed. Here, the additional analysis of DWI led to two additional false positive findings, while the number of true positive findings could not be increased. CONCLUSION: In conclusion, integrated 18F-FDG PET/MR does not reliably differentiate N-positive from N-negative melanoma patients. Additional DWI does not increase the sensitivity of 18F-FDG PET/MR. Hence, sentinel lymph node biopsy cannot be replaced by 18F-FDG-PE/MR or 18F-FDG-PET/CT.


Subject(s)
Magnetic Resonance Imaging/methods , Melanoma/diagnostic imaging , Multimodal Imaging/methods , Positron Emission Tomography Computed Tomography/methods , Sentinel Lymph Node/diagnostic imaging , Adult , Aged , False Negative Reactions , Female , Fluorodeoxyglucose F18 , Humans , Lymphatic Metastasis , Male , Melanoma/pathology , Middle Aged , Radiopharmaceuticals , Sentinel Lymph Node/pathology , Sentinel Lymph Node Biopsy
5.
Clin Imaging ; 49: 163-168, 2018.
Article in English | MEDLINE | ID: mdl-29554613

ABSTRACT

PURPOSE: To assess the response to initial treatment strategies of cervical cancer using multiparametric-PET/MRI. MATERIAL AND METHODS: PET/MR-derived morphological (tumor size), functional (DWI, DCE-MRI) and metabolic (18F-FDG PET) parameters were acquired in pre- and posttreatment examinations of 8 patients. Besides RECIST- and PERCIST-criteria, functional quantitative parameters were used to assess therapeutic response. RESULTS: RECIST- and PERCIST-response criteria demonstrated high correlations for the differentiation between therapy-responders and non-responders, which was additionally reflected by functional (DWI, DCE-MRI) quantitative imaging parameters. CONCLUSION: Multiparametric-PET/MRI bears the potential of a more comprehensive response assessment of initial treatment strategies in cervical cancer patients.


Subject(s)
Cervix Uteri/pathology , Chemoradiotherapy , Magnetic Resonance Imaging/methods , Positron-Emission Tomography/methods , Uterine Cervical Neoplasms , Adult , Aged , Female , Fluorodeoxyglucose F18 , Humans , Middle Aged , Outcome Assessment, Health Care , Uterine Cervical Neoplasms/diagnostic imaging , Uterine Cervical Neoplasms/pathology , Uterine Cervical Neoplasms/therapy
6.
J Nucl Med ; 58(10): 1617-1623, 2017 10.
Article in English | MEDLINE | ID: mdl-28408531

ABSTRACT

The interobserver agreement for 68Ga-PSMA-11 PET/CT study interpretations in patients with prostate cancer is unknown. Methods:68Ga-PSMA-11 PET/CT was performed in 50 patients with prostate cancer for biochemical recurrence (n = 25), primary diagnosis (n = 10), biochemical persistence after primary therapy (n = 5), or staging of known metastatic disease (n = 10). Images were reviewed by 16 observers who used a standardized approach for interpretation of local (T), nodal (N), bone (Mb), or visceral (Mc) involvement. Observers were classified as having a low (<30 prior 68Ga-PSMA-11 PET/CT studies; n = 5), intermediate (30-300 studies; n = 5), or high level of experience (>300 studies; n = 6). Histopathology (n = 25, 50%), post-external-beam radiation therapy prostate-specific antigen response (n = 15, 30%), or follow-up PET/CT (n = 10, 20%) served as a standard of reference. Observer groups were compared by overall agreement (% patients matching the standard of reference) and Fleiss' κ with mean and corresponding 95% confidence interval (CI). Results: Agreement among all observers was substantial for T (κ = 0.62; 95% CI, 0.59-0.64) and N (κ = 0.74; 95% CI, 0.71-0.76) staging and almost perfect for Mb (κ = 0.88; 95% CI, 0.86-0.91) staging. Level of experience positively correlated with agreement for T (κ = 0.73/0.66/0.50 for high/intermediate/low experience, respectively), N (κ = 0.80/0.76/0.64, respectively), and Mc staging (κ = 0.61/0.46/0.36, respectively). Interobserver agreement for Mb was almost perfect irrespective of prior experience (κ = 0.87/0.91/0.88, respectively). Observers with low experience, when compared with intermediate and high experience, demonstrated significantly lower median overall agreement (54% vs. 66% and 76%, P = 0.041) and specificity for T staging (73% vs. 88% and 93%, P = 0.032). Conclusion: The interpretation of 68Ga-PSMA-11 PET/CT for prostate cancer staging is highly consistent among observers with high levels of experience, especially for nodal and bone assessments. Initial training on at least 30 patient cases is recommended to ensure acceptable performance.


Subject(s)
Organometallic Compounds , Positron Emission Tomography Computed Tomography , Prostatic Neoplasms/diagnostic imaging , Aged , Aged, 80 and over , Edetic Acid/analogs & derivatives , Gallium Isotopes , Gallium Radioisotopes , Humans , Image Interpretation, Computer-Assisted , Male , Middle Aged , Observer Variation , Oligopeptides , Prospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...