Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Ultrasound Med ; 39(10): 2033-2042, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32395885

ABSTRACT

OBJECTIVES: Traditional Doppler measures have been used to predict cognitive performance in patients with carotid atherosclerosis. Novel measures, such as carotid plaque strain indices (CPSIs), have shown associations with cognitive performance. We hypothesized that lower mean middle cerebral artery (MCA) velocities, higher bulb-internal carotid artery (ICA) velocities, the MCA pulsatility index (PI), and CPSIs would be associated with poorer cognitive performance in individuals with advanced atherosclerosis. METHODS: Neurocognitive testing, carotid ultrasound imaging, transcranial Doppler imaging, and carotid strain imaging were performed on 40 patients scheduled for carotid endarterectomy. Kendall tau correlations were used to examine relationships between cognitive tests and the surgical-side maximum peak systolic velocity (PSV; from the bulb, proximal, mid, or distal ICA), mean MCA velocity and PI, and maximum CPSIs (axial, lateral, and shear strain indices used to characterize plaque deformations with arterial pulsation). Cognitive measures included age-adjusted indices of verbal fluency, verbal and visual learning/memory, psychomotor speed, auditory attention/working memory, visuospatial construction, and mental flexibility. RESULTS: Participants had a median age of 71.0 (interquartile range, 9.75) years; 26 were male (65%), and 14 were female (35%). Traditional Doppler parameters, PSV, mean MCA velocity, and MCA PI did not predict cognitive performance (all P > .05). Maximum CPSIs were significantly associated with cognitive performance (P < .05). CONCLUSIONS: Traditional velocity measurements of the maximum bulb-ICA PSV, mean MCA velocity, and PI were not associated with cognitive performance in patients with advanced atherosclerotic disease; however, maximum CPSIs were associated with cognitive performance. These findings suggest that cognition may be associated with unstable plaque rather than blood flow.


Subject(s)
Atherosclerosis , Carotid Stenosis , Blood Flow Velocity , Carotid Arteries/diagnostic imaging , Carotid Stenosis/complications , Carotid Stenosis/diagnostic imaging , Child , Cognition , Female , Humans , Male , Middle Cerebral Artery/diagnostic imaging , Ultrasonography, Doppler, Transcranial
2.
Ultrasound Med Biol ; 46(6): 1513-1532, 2020 06.
Article in English | MEDLINE | ID: mdl-32291105

ABSTRACT

Quantitative ultrasound has been used to assess carotid plaque tissue composition. Here, we compute the attenuation coefficient (AC) in vivo with the optimum power spectral shift estimator (OPSSE) and reference phantom method (RPM), extract AC parameters and form parametric maps. Differences between OPSSE and RPM AC parameters are computed. Relationships between AC parameters, surgical scores and histopathology assessments are examined. Kendall's τ correlations between OPSSE AC and surgical scores are significant, including those between cholesterol and Standard Deviation (adjusted p = 0.038); thrombus and Minimum (adjusted p = 0.002), Maximum (adjusted p = 0.021) and Standard Deviation (adjusted p = 0.001); ulceration and Average (adjusted p = 0.033), Median (unadjusted p = 0.013), Maximum (unadjusted p = 0.039) and Mode (adjusted p = 0.009). The strongest correlations with histopathology are percentage cholesterol and Median OPSSE (unadjusted p = 0.007); percentage hemorrhage and Minimum OPSSE (adjusted p < 0.001); hemosiderin score and Median OPSSE (adjusted p = 0.010); and percentage calcium and Percentage Non-physical RPM Pixels (unadjusted p = 0.014). Kruskal-Wallis H and Dunn's post hoc tests have the ability to distinguish between groups (p < 0.05). Results suggest AC parameters may assist in vivo evaluation of carotid plaque vulnerability.


Subject(s)
Carotid Artery Diseases/diagnostic imaging , Plaque, Atherosclerotic/diagnostic imaging , Ultrasonography , Aged , Calcium/analysis , Carotid Artery Diseases/pathology , Cholesterol/analysis , Female , Hemorrhage/pathology , Hemosiderin/analysis , Humans , Image Interpretation, Computer-Assisted , Male , Plaque, Atherosclerotic/chemistry , Plaque, Atherosclerotic/pathology , Thrombosis/pathology , Ulcer/pathology
3.
J Ultrasound Med ; 38(2): 307-319, 2019 Feb.
Article in English | MEDLINE | ID: mdl-30027550

ABSTRACT

OBJECTIVES: The purpose of this study was to determine the reliability of grayscale median (GSM) measurements across different ultrasound (US) systems and effects of gain on GSM values. METHODS: Two vessels in a grayscale vascular phantom were imaged with 7 US systems at 3 gain settings. Two human participants were imaged at 3 gain settings. Each image was normalized, standardized, and segmented by expert and novice readers using grayscale analysis software. The concordance correlation coefficient (CCC) assessed agreement of GSM values for each system across gain settings and vessels and between readers. The intraclass correlation coefficient (ICC) assessed system-level reader concordance across gain settings and vessels. A general linear mixed model for repeated measures was used to assess within- and between-system mean GSM values. RESULTS: Grayscale median measurements performed on images from the same US system yielded excellent (CCC) (95% confidence intervals): 0.85 (0.75, 0.92) to 0.96 (0.92, 0.98). ICC per system were 0.94 to 0.98 for the expert reader and 0.85 to 0.95 for the novice reader. Gain adjustments above and below an optimal setting contributed to significantly different intrasystem GSM values on 4 of 7 systems in the near zone and 5 of 7 systems in the far zone (P < .05). Intersystem GSM values differed on 5 of 7 systems (P < .05). Images from the human participants showed differences in GSM values at optimum gain values ± 10 dB/%. CONCLUSIONS: Grayscale median measurements are highly reproducible when obtained from the same US system with similar gain settings. Grayscale median values differ significantly across gain values and between systems. Researchers should consider the impact of US system and gain settings on GSM values when working to minimize system- and operator-dependent factors.


Subject(s)
Carotid Artery Diseases/diagnostic imaging , Carotid Artery, Common/diagnostic imaging , Phantoms, Imaging , Ultrasonography/instrumentation , Ultrasonography/methods , Humans , Reproducibility of Results
4.
Ultrasound Med Biol ; 43(9): 1861-1867, 2017 09.
Article in English | MEDLINE | ID: mdl-28645797

ABSTRACT

The purpose of this study was to determine the relationship between symptomatic status, transcranial Doppler (TCD) microemboli presence and plaque histopathology findings. TCD was performed on 60 patients (37 symptomatic, 23 asymptomatic) before undergoing clinically indicated carotid endarterectomy. The frequency of microemboli signals was not significantly different between symptomatic and asymptomatic subject groups (p = 0.88) and there were no differences observed in the macroscopic or histopathology scoring of these plaques (p-values all > 0.05). The presence of microemboli was associated with an ulceration score (regardless of symptomatic or asymptomatic status, p = 0.034), with a one-level increase in ulceration rating associated with an odds ratio of 5.86 (95% [CI] 1.55, 43.4). These findings suggest that both symptomatic and asymptomatic patients may have plaque with similar features of instability and ability to create emboli. Thus, identifying new ways to measure plaque instability may provide important information for optimizing treatment to prevent future stroke.


Subject(s)
Carotid Arteries/diagnostic imaging , Embolism/diagnostic imaging , Ultrasonography, Doppler, Transcranial/methods , Aged , Female , Humans , Male , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...