Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 72
Filter
1.
Magn Reson Med ; 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730562

ABSTRACT

PURPOSE: T1 mapping is a widely used quantitative MRI technique, but its tissue-specific values remain inconsistent across protocols, sites, and vendors. The ISMRM Reproducible Research and Quantitative MR study groups jointly launched a challenge to assess the reproducibility of a well-established inversion-recovery T1 mapping technique, using acquisition details from a seminal T1 mapping paper on a standardized phantom and in human brains. METHODS: The challenge used the acquisition protocol from Barral et al. (2010). Researchers collected T1 mapping data on the ISMRM/NIST phantom and/or in human brains. Data submission, pipeline development, and analysis were conducted using open-source platforms. Intersubmission and intrasubmission comparisons were performed. RESULTS: Eighteen submissions (39 phantom and 56 human datasets) on scanners by three MRI vendors were collected at 3 T (except one, at 0.35 T). The mean coefficient of variation was 6.1% for intersubmission phantom measurements, and 2.9% for intrasubmission measurements. For humans, the intersubmission/intrasubmission coefficient of variation was 5.9/3.2% in the genu and 16/6.9% in the cortex. An interactive dashboard for data visualization was also developed: https://rrsg2020.dashboards.neurolibre.org. CONCLUSION: The T1 intersubmission variability was twice as high as the intrasubmission variability in both phantoms and human brains, indicating that the acquisition details in the original paper were insufficient to reproduce a quantitative MRI protocol. This study reports the inherent uncertainty in T1 measures across independent research groups, bringing us one step closer to a practical clinical baseline of T1 variations in vivo.

2.
Sci Rep ; 14(1): 8974, 2024 04 18.
Article in English | MEDLINE | ID: mdl-38637577

ABSTRACT

Fully CMR-guided electrophysiological interventions (EP-CMR) have recently been introduced but data on the optimal CMR imaging protocol are scarce. This study determined the clinical utility of 3D non-selective whole heart steady-state free precession imaging using compressed SENSE (nsWHcs) for automatic segmentation of cardiac cavities as the basis for targeted catheter navigation during EP-CMR cavo-tricuspid isthmus ablation. Fourty-two consecutive patients with isthmus-dependent right atrial flutter underwent EP-CMR radiofrequency ablations. nsWHcs succeeded in all patients (nominal scan duration, 98 ± 10 s); automatic segmentation/generation of surface meshes of right-sided cavities exhibited short computation times (16 ± 3 s) with correct delineation of right atrium, right ventricle, tricuspid annulus and coronary sinus ostium in 100%, 100%, 100% and 95%, respectively. Point-by-point ablation adhered to the predefined isthmus line in 62% of patients (26/42); activation mapping confirmed complete bidirectional isthmus block (conduction time difference, 136 ± 28 ms). nsWHcs ensured automatic and reliable 3D segmentation of targeted endoluminal cavities, multiplanar reformatting and image fusion (e.g. activation time measurements) and represented the basis for precise real-time active catheter navigation during EP-CMR ablations of isthmus-dependent right atrial flutter. Hence, nsWHcs can be considered a key component in order to advance EP-CMR towards the ultimate goal of targeted substrate-based ablation procedures.


Subject(s)
Atrial Flutter , Catheter Ablation , Humans , Atrial Flutter/diagnostic imaging , Atrial Flutter/surgery , Surgical Mesh , Catheter Ablation/methods , Heart Atria/diagnostic imaging , Heart Atria/surgery , Arrhythmias, Cardiac , Treatment Outcome
3.
Front Cardiovasc Med ; 10: 1200833, 2023.
Article in English | MEDLINE | ID: mdl-37692049

ABSTRACT

Background: Cardiac magnetic resonance (CMR) imaging allows for multiparametric assessment of healthy pulmonary artery (PA) hemodynamics. Gender- and aging-associated PA stiffness and pressure alterations have remained clinically unestablished, however may demonstrate epidemiological differences in disease development. The aim of this study is to evaluate the role of CMR as a surrogate for catheter examinations by providing a comprehensive CMR assessment of sex- and age-related reference values for PA stiffness, flow, and pressure. Methods and Results: PA hemodynamics were studied between gender and age groups (>/<50 years) using phase-contrast CMR. Corresponding correlation analyses were performed. 179 healthy volunteers with a median age of 32.6 years (range 11.3-68.2) were examined. Males demonstrated increased PA compliance (median [interquartile range] or mean ± standard deviation) (20.8 mm2/mmHg [16.6; 25.8] vs. 19.2 ± 7.1 mm2/mmHg; P < 0.033), higher pulse wave velocity (2.00 m/s [1.35; 2.87] vs. 1.73 m/s [1.19; 2.34]; P = 0.018) and a reduced full width half maximum (FWHM) (219 ± 22 ms vs. 235 ± 23 ms; P < 0.001) than females. Mean, systolic, diastolic PA pressure and pulmonary proportional pulse pressure were significantly elevated for males compared to females (P < 0.001). Older subjects (>50 years) exhibited reduced PA elasticity (41.7% [31.0; 52.9] vs. 66.4% [47.7; 83.0]; P < 0.001), reduced PA compliance (15.4 mm2/mmHg [12.3; 20.7] vs. 21.3 ± 6.8 mm2/mmHg; P < 0.001), higher pulse wave velocity (2.59 m/s [1.57; 3.59] vs. 1.76 m/s [1.24; 2.34]; P < 0.001) and a reduced FWHM (218 ± 29 ms vs. 231 ± 21 ms; P < 0.001) than younger subjects. Conclusions: Velocity-time profiles are dependent on age and gender. PA stiffness indices deteriorate with age. CMR has potential to serve as a surrogate for right heart catheterization.

4.
Am J Cardiovasc Dis ; 13(2): 73-86, 2023.
Article in English | MEDLINE | ID: mdl-37213319

ABSTRACT

AIMS: No data is available about the significance of cardiovascular magnetic resonance (CMR) derived vascular distensibility (VD) and vessel wall ratio (VWR) for risk stratification in patients with type 2 diabetes mellitus (T2DM). Therefore, this study aimed to investigate the effects of T2DM on VD and VWR using CMR in both central and peripheral territories. METHODS: Thirty-one T2DM-patients and nine controls underwent CMR. Angulation of the aorta, the common carotid, and the coronary arteries was performed to obtain cross-sectional vessel areas. RESULTS: In T2DM the Carotid-VWR and the Aortic-VWR correlated significantly. Mean values of Carotid-VWR and Aortic-VWR were significantly higher in T2DM than in controls. Coronary-VD was significantly lower in T2DM than in controls. No significant difference in Carotid-VD or Aortic-VD in T2DM vs. controls, respectively, could be observed. In a subgroup of thirteen T2DM patients with coronary artery disease (CAD), Coronary-VD was significantly lower and Aortic-VWR was significantly higher compared to T2DM patients without CAD. CONCLUSION: CMR allows a simultaneous evaluation of the structure and function of three important vascular territories to detect vascular remodeling in T2DM.

7.
Eur Radiol ; 33(7): 4648-4656, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36683089

ABSTRACT

OBJECTIVES: This study analyzed the prevalence and pattern of focal and potential diffuse myocardial fibrosis detected by late gadolinium enhancement (LGE) and extracellular volume (ECV) imaging in male and female marathon runners using cardiac magnetic resonance (CMR). METHODS: Seventy-four marathon runners were studied including 55 males (44 ± 8 years) and 19 females (36 ± 7 years) and compared to 36 controls with similar age and sex using contrast-enhanced CMR, exercise testing, and blood samples. RESULTS: Contrast-enhanced CMR revealed focal myocardial fibrosis in 8 of 74 runners (11%). The majority of runners were male (7 of 8, 88%). LGE was typically non-ischemic in 7 of 8 runners (88%) and ischemic in one runner. ECV was higher in remote myocardium without LGE in male runners (25.5 ± 2.3%) compared to male controls (24.0 ± 3.0%, p < 0.05), indicating the potential presence of diffuse myocardial fibrosis. LV mass was higher in LGE + males (86 ± 18 g/m2) compared to LGE- males (73 ± 14 g/m2, p < 0.05). Furthermore, LGE + males had lower weight (69 ± 9 vs 77 ± 9 kg, p < 0.05) and shorter best marathon finishing times (3.2 ± 0.3 h) compared to LGE- males (3.6 ± 0.4 h, p < 0.05) suggesting higher training load in these runners to accomplish the marathon in a short time. CONCLUSION: The high frequency of non-ischemic myocardial fibrosis in LGE + male runners can be related to increased LV mass in these runners. Furthermore, a higher training load could explain the higher LV mass and could be one additional cofactor in the genesis of myocardial fibrosis in marathon runners. KEY POINTS: • A high frequency of myocardial fibrosis was found in marathon runners. • Myocardial fibrosis occurred typically in male runners and was typically non-ischemic. • Higher training load could be one cofactor in the genesis of myocardial fibrosis in marathon runners.


Subject(s)
Cardiomyopathies , Contrast Media , Male , Humans , Female , Marathon Running , Prevalence , Magnetic Resonance Imaging, Cine , Gadolinium , Myocardium/pathology , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/epidemiology , Cardiomyopathies/pathology , Fibrosis , Magnetic Resonance Spectroscopy , Predictive Value of Tests
8.
Magn Reson Med ; 89(5): 2005-2013, 2023 05.
Article in English | MEDLINE | ID: mdl-36585913

ABSTRACT

PURPOSE: To evaluate a silent MR active catheter tracking sequence that allows conducting catheter interventions with low acoustic noise levels. METHODS: To reduce the acoustic noise associated with MR catheter tracking, we implemented a technique previously used in conventional MRI. The gradient waveforms are modified to reduce the sound pressure level (SPL) and avoid acoustic resonances of the MRI system. The efficacy of the noise reduction was assessed by software-predicted SPL and verified by measurements. Furthermore, the quality of the catheter tracking signal was assessed in a phantom experiment and during interventional cardiovascular MRI sessions targeted at isthmus-related flutter ablation. RESULTS: The maximum measured SPL in the scanner room was 104 dB(A) for real-time imaging, and 88 dB(A) and 69 dB(A) for conventional and silent tracking, respectively. The SPL measured at different positions in the MR suite using silent tracking were 65-69 dB(A), and thus within the range of a normal conversation. Equivalent signal quality and tracking accuracy were obtained using the silent variant of the catheter tracking sequence. CONCLUSION: Our results indicate that silent MR catheter tracking capabilities are identical to conventional catheter tracking. The achieved acoustic noise reduction comes at no penalty in terms of tracking quality or temporal resolution, improves comfort and safety, and can overcome the need for MR-compatible communication equipment and background noise suppression during the actual interventional procedure.


Subject(s)
Magnetic Resonance Imaging, Interventional , Magnetic Resonance Imaging , Magnetic Resonance Imaging/methods , Catheters , Software , Magnetic Resonance Imaging, Interventional/methods , Phantoms, Imaging
9.
J Transl Med ; 20(1): 580, 2022 12 09.
Article in English | MEDLINE | ID: mdl-36494667

ABSTRACT

BACKGROUND: Muscle fatigue and pain are key symptoms of Myalgic Encephalomyelitis/Chronic Fatigue Syndrome (ME/CFS). Although the pathophysiology is not yet fully understood, there is ample evidence for hypoperfusion which may result in electrolyte imbalance and sodium overload in muscles. Therefore, the aim of this study was to assess levels of sodium content in muscles of patients with ME/CFS and to compare these to healthy controls. METHODS: Six female patients with ME/CFS and six age, BMI and sex matched controls underwent 23Na-MRI of the left lower leg using a clinical 3T MR scanner before and after 3 min of plantar flexion exercise. Sodium reference phantoms with solutions of 10, 20, 30 and 40 mmol/L NaCl were used for quantification. Muscle sodium content over 40 min was measured using a dedicated plugin in the open-source DICOM viewer Horos. Handgrip strength was measured and correlated with sodium content. RESULTS: Baseline tissue sodium content was higher in all 5 lower leg muscle compartments in ME/CFS compared to controls. Within the anterior extensor muscle compartment, the highest difference in baseline muscle sodium content between ME/CFS and controls was found (mean ± SD; 12.20 ± 1.66 mM in ME/CFS versus 9.38 ± 0.71 mM in controls, p = 0.0034). Directly after exercise, tissue sodium content increased in gastrocnemius and triceps surae muscles with + 30% in ME/CFS (p = 0.0005) and + 24% in controls (p = 0.0007) in the medial gastrocnemius muscle but not in the extensor muscles which were not exercised. Compared to baseline, the increase of sodium content in medial gastrocnemius muscle was stronger in ME/CFS than in controls with + 30% versus + 17% to baseline at 12 min (p = 0.0326) and + 29% versus + 16% to baseline at 15 min (p = 0.0265). Patients had reduced average handgrip strength which was associated with increased average muscle tissue sodium content (p = 0.0319, R2 = 0.3832). CONCLUSION: Muscle sodium content before and after exercise was higher in ME/CFS than in healthy controls. Furthermore, our findings indicate an inverse correlation between muscle sodium content and handgrip strength. These findings provide evidence that sodium overload may play a role in the pathophysiology of ME/CFS and may allow for potential therapeutic targeting.


Subject(s)
Fatigue Syndrome, Chronic , Humans , Female , Hand Strength , Sodium , Muscle, Skeletal , Magnetic Resonance Imaging
10.
Front Cardiovasc Med ; 9: 877416, 2022.
Article in English | MEDLINE | ID: mdl-35711381

ABSTRACT

Background: Case series have reported persistent cardiopulmonary symptoms, often termed long-COVID or post-COVID syndrome, in more than half of patients recovering from Coronavirus Disease 19 (COVID-19). Recently, alterations in microvascular perfusion have been proposed as a possible pathomechanism in long-COVID syndrome. We examined whether microvascular perfusion, measured by quantitative stress perfusion cardiac magnetic resonance (CMR), is impaired in patients with persistent cardiac symptoms post-COVID-19. Methods: Our population consisted of 33 patients post-COVID-19 examined in Berlin and London, 11 (33%) of which complained of persistent chest pain and 13 (39%) of dyspnea. The scan protocol included standard cardiac imaging and dual-sequence quantitative stress perfusion. Standard parameters were compared to 17 healthy controls from our institution. Quantitative perfusion was compared to published values of healthy controls. Results: The stress myocardial blood flow (MBF) was significantly lower [31.8 ± 5.1 vs. 37.8 ± 6.0 (µl/g/beat), P < 0.001] and the T2 relaxation time was significantly higher (46.2 ± 3.6 vs. 42.7 ± 2.8 ms, P = 0.002) post-COVID-19 compared to healthy controls. Stress MBF and T1 and T2 relaxation times were not correlated to the COVID-19 severity (Spearman r = -0.302, -0.070, and -0.297, respectively) or the presence of symptoms. The stress MBF showed a U-shaped relation to time from PCR to CMR, no correlation to T1 relaxation time, and a negative correlation to T2 relaxation time (Pearson r = -0.446, P = 0.029). Conclusion: While we found a significantly reduced microvascular perfusion post-COVID-19 compared to healthy controls, this reduction was not related to symptoms or COVID-19 severity.

11.
Circulation ; 145(25): 1811-1824, 2022 06 21.
Article in English | MEDLINE | ID: mdl-35621277

ABSTRACT

BACKGROUND: Endomyocardial biopsy (EMB) is the gold standard method for surveillance of acute cardiac allograft rejection (ACAR) despite its invasive nature. Cardiovascular magnetic resonance (CMR)-based myocardial tissue characterization allows detection of myocarditis. The feasibility of CMR-based surveillance for ACAR-induced myocarditis in the first year after heart transplantation is currently undescribed. METHODS: CMR-based multiparametric mapping was initially assessed in a prospective cross-sectional fashion to establish agreement between CMR- and EMB-based ACAR and to determine CMR cutoff values between rejection grades. A prospective randomized noninferiority pilot study was then undertaken in adult orthotopic heart transplant recipients who were randomized at 4 weeks after orthotopic heart transplantation to either CMR- or EMB-based rejection surveillance. Clinical end points were assessed at 52 weeks. RESULTS: Four hundred one CMR studies and 354 EMB procedures were performed in 106 participants. Forty heart transplant recipients were randomized. CMR-based multiparametric assessment was highly reproducible and reliable at detecting ACAR (area under the curve, 0.92; sensitivity, 93%; specificity, 92%; negative predictive value, 99%) with greater specificity and negative predictive value than either T1 or T2 parametric CMR mapping alone. High-grade rejection occurred in similar numbers of patients in each randomized group (CMR, n=7; EMB, n=8; P=0.74). Despite similarities in immunosuppression requirements, kidney function, and mortality between groups, the rates of hospitalization (9 of 20 [45%] versus 18 of 20 [90%]; odds ratio, 0.091; P=0.006) and infection (7 of 20 [35%] versus 14 of 20 [70%]; odds ratio, 0.192; P=0,019) were lower in the CMR group. On 15 occasions (6%), patients who were randomized to the CMR arm underwent EMB for clarification or logistic reasons, representing a 94% reduction in the requirement for EMB-based surveillance. CONCLUSIONS: A noninvasive CMR-based surveillance strategy for ACAR in the first year after orthotopic heart transplantation is feasible compared with EMB-based surveillance. REGISTRATION: HREC/13/SVH/66 and HREC/17/SVH/80. AUSTRALIAN NEW ZEALAND CLINICAL TRIALS REGISTRY: ACTRN12618000672257.


Subject(s)
Heart Transplantation , Myocarditis , Adult , Australia/epidemiology , Biopsy/methods , Cross-Sectional Studies , Graft Rejection/diagnosis , Heart Transplantation/adverse effects , Humans , Magnetic Resonance Spectroscopy , Myocarditis/diagnosis , Myocardium/pathology , Pilot Projects , Prospective Studies
12.
Front Cardiovasc Med ; 9: 829392, 2022.
Article in English | MEDLINE | ID: mdl-35463791

ABSTRACT

Serious adverse events associated with new vaccines targeting SARS-CoV-2 are of high interest to the public and to public health as a worldwide mass immunization campaign has been initiated to contain the ongoing COVID-19 pandemic. We describe a series of 4 individuals with signs of a myocarditis/pericarditis according to cardiac MRI results in temporal association with currently in the European Union authorized SARS-CoV-2 vaccines. We found mild abnormal MRI results independent of the type of SARS-CoV-2 vaccine. There is a need of continuing monitoring outcomes of myocarditis cases after COVID-19 vaccination as recently published cases suggest an uncomplicated short-term course whereas the long-term implications are not yet known but taking the available evidence into account the benefits of using COVID-19 vaccines still clearly outweigh the risks.

13.
Circ Cardiovasc Imaging ; 15(4): e013745, 2022 04.
Article in English | MEDLINE | ID: mdl-35360924

ABSTRACT

BACKGROUND: The calculation of extracellular volume (ECV) in cardiac magnetic resonance requires hematocrit, limiting its applicability in clinical practice. Based on the linear relationship between hematocrit and blood T1 relaxivity, a synthetic ECV could be estimated without a blood sample. We aim to develop and test regression models for synthetic ECV without blood sampling in 1.5-T and 3.0-T scanners. METHODS: A total of 1101 subjects who underwent cardiac magnetic resonance scanning with native and postcontrast T1 mapping and venous hematocrit within 24 hours were retrospectively enrolled. Subjects were randomly split into derivation (n=550) and validation (n=551) subgroups for each scanner. Different regression models were derived controlling for sex, field strength, and left ventricle/right ventricle blood pool and validated in the validation group. We performed additional validation analyses in subgroups of patients with histological validation (n=17), amyloidosis (n=29), anemia (n=185), and reduced ejection fraction (n=322). RESULTS: In the derivation group, 8 specific models and 2 common estimate models were derived. In the validation group, using specific models, synthetic ECV had high agreement with conventional ECV (R2, 0.87; P<0.0001 and R2, 0.88, P<0.0001; -0.16% and -0.10%, left ventricle and right ventricle model, respectively). Common models also performed well (R2, 0.88; P<0.0001 and R2, 0.89, P<0.0001; -0.21% and -0.18%, left ventricle and right ventricle model, respectively). Histological validation demonstrated equal performance of synthetic and measured ECV. Synthetic ECV as calculated by the common model showed a bias in the anemia cohort significantly reduced by the specific model (-2.45 to -1.28, right ventricle common and specific model, respectively). CONCLUSIONS: Synthetic ECV provided a promising way to calculate ECV without blood sampling. Specific models could provide the most accurate value, while common models could be more suitable in routine clinical practice because of their simplicity while maintaining adequate accuracy.


Subject(s)
Magnetic Resonance Imaging, Cine , Myocardium , Contrast Media , Fibrosis , Humans , Magnetic Resonance Spectroscopy , Myocardium/pathology , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies
14.
ESC Heart Fail ; 9(1): 110-121, 2022 02.
Article in English | MEDLINE | ID: mdl-34866358

ABSTRACT

AIMS: Although the prevalence of coronary artery disease (CAD) is high among patients with atrial fibrillation (AF), studies on stress perfusion cardiac magnetic resonance (CMR) imaging frequently exclude patients with AF, and its prognostic and diagnostic value in high-risk patients with suspected or known CAD remains unclear. METHODS AND RESULTS: In this longitudinal cohort study, we included 164 consecutive patients with AF during vasodilator perfusion CMR. Diagnostic value was evaluated regarding invasive coronary angiography in a subset of patients. We targeted a follow-up of >5 years and used CMR results as stratification, and the primary outcome was major adverse cardiac events [MACE, cardiovascular (CV) death and myocardial infarction (MI)]. Secondary outcomes included late coronary revascularization or stroke and the components of the primary outcome. Of the whole cohort (73.8% male, mean age 72.2 years ± 7.8 SD), 99.4% were successfully scanned (163/164 patients). Median CHA2DS2-VASc score was 4 [interquartile range (IQR) 3-5], and median 10-year risk for CV events based on SMART risk score was high (24%, IQR 16-32%). Thirty-two patients (19.6%) presented with ischaemia and 52 patients (31.9%) with late gadolinium enhancement (LGE). A combination of LGE and inducible ischaemia was present in 20 patients (12.3%). Diagnostic accuracy was 86.2% [confidence interval (CI) 68.3-96.1%]. The median follow-up was 6.6 years (IQR 3.6-7.8). Ischaemia in vasodilator perfusion CMR was significantly associated with the occurrence of MACE [P < 0.01; hazard ratio (HR) 2.65, CI 1.39-5.08], as well as LGE (P = 0.03; 1.74, CI 1.07-3.64) and the combination of both (P < 0.01; HR 2.67, CI 1.59-5.62). After adjustment by age, left ventricular ejection fraction, and the presence of diabetes, ischaemia in vasodilator perfusion CMR remained significantly associated with the occurrence of MACE (2.10, CI 1.08-4.10; P = 0.03). In secondary endpoint analysis, there was a significant association of ischaemia in CMR with CV death (P < 0.05; HR 1.93, CI 0.95-3.9) and MI (P < 0.01; HR 13, CI 1.35-125.4), while no significant association was found regarding the occurrence of revascularization (P = 0.45; HR 1.43, CI 0.57-3.58) or stroke (P = 0.99; HR 0.99, CI 0.21-2.59). CONCLUSIONS: Vasodilator stress perfusion CMR demonstrated an excellent diagnostic and significant prognostic value at long-term follow-up in high-risk patients with persistent AF and suspected or known CAD.


Subject(s)
Atrial Fibrillation , Vasodilator Agents , Aged , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Contrast Media , Female , Gadolinium , Humans , Longitudinal Studies , Magnetic Resonance Imaging, Cine , Magnetic Resonance Spectroscopy , Male , Predictive Value of Tests , Prognosis , Risk Assessment , Stroke Volume , Ventricular Function, Left
15.
Eur Radiol ; 32(3): 1853-1865, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34536111

ABSTRACT

OBJECTIVES: Cancer therapy-related cardiac dysfunction (CTRCD) is a relevant clinical problem and needs early prediction. This study aimed to analyze myocardial injury using serial laboratory and cardiac magnetic resonance imaging (CMR) parameters after epirubicin-based chemotherapy compared with left-sided radiotherapy and to study their value for early prediction of CTRCD. METHODS: Sixty-six consecutive women (53 ± 13 years) including n = 39 with epirubicin-based chemotherapy and n = 27 with left-sided radiotherapy were prospectively studied by 3 T CMR including left ventricular (LV) mass and volumes for ejection fraction (LVEF), as well as feature-tracking with global longitudinal strain (GLS) and T1/T2 mapping. CMR was performed at baseline, at therapy completion (follow-up 1, FU1), and after 13 ± 2 months (FU2). CTRCD was defined as LVEF decline of at least 10% to < 55% or a > 15% GLS change at FU2. RESULTS: T1 and T2 increased at FU1 after epirubicin-based chemotherapy, but not after left-sided radiotherapy. CTRCD occurred in 20% of patients after epirubicin-based chemotherapy and in 4% after left-sided radiotherapy. T1 at FU1 was the best single parameter to predict CTRCD with an area under the curve (AUC) of 0.712 (CI 0.587-0.816, p = 0.005) with excellent sensitivity (100%, 66-100%), but low specificity (44%, 31-58%). Combined use of increased T1 and LVEF ≤ 60% at FU1 improved AUC to 0.810 (0.695-0.896) resulting in good sensitivity (78%, 44-95%) and specificity (84%, 72-92%). CONCLUSION: Only epirubicin-based chemotherapy, but not left-sided radiotherapy, resulted in increased T1/T2 myocardial relaxation times as a marker of myocardial injury. Combined use of CMR parameters may allow an early prediction of subsequent CTCRD. KEY POINTS: • Myocardial T1 and T2 relaxation times increased at FU1 after epirubicin-based chemotherapy, but not after left-sided radiotherapy. • Cancer therapy-related cardiac dysfunction (CTRCD) occurred in 20% of patients after epirubicin-based chemotherapy and in 4% after left-sided radiotherapy. • Combined use of increased T1 and reduced LVEF had an AUC of 0.810 (0.695-0.896) to predict CTRCD with good sensitivity (78%, 44-95%) and specificity (84%, 72-92%).


Subject(s)
Breast Neoplasms , Heart Diseases , Ventricular Dysfunction, Left , Breast Neoplasms/drug therapy , Breast Neoplasms/radiotherapy , Cardiotoxicity/diagnostic imaging , Cardiotoxicity/etiology , Epirubicin/adverse effects , Female , Humans , Magnetic Resonance Imaging , Magnetic Resonance Imaging, Cine , Predictive Value of Tests , Stroke Volume , Ventricular Dysfunction, Left/chemically induced , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Function, Left
16.
Int J Cardiovasc Imaging ; 38(9): 2057-2071, 2022 Sep.
Article in English | MEDLINE | ID: mdl-37726611

ABSTRACT

Cardiac involvement has been described in varying proportions of patients recovered from COVID-19 and proposed as a potential cause of prolonged symptoms, often described as post-COVID or long COVID syndrome. Recently, cardiac complications have been reported from COVID-19 vaccines as well. We aimed to compare CMR-findings in patients with clinical cardiac symptoms after COVID-19 and after vaccination. From May 2020 to May 2021, we included 104 patients with suspected cardiac involvement after COVID-19 who received a clinically indicated cardiac magnetic resonance (CMR) examination at a high-volume center. The mean time from first positive PCR to CMR was 112 ± 76 days. During their COVID-19 disease, 21% of patients required hospitalization, 17% supplemental oxygen and 7% mechanical ventilation. In 34 (32.7%) of patients, CMR provided a clinically relevant diagnosis: Isolated pericarditis in 10 (9.6%), %), acute myocarditis (both LLC) in 7 (6.7%), possible myocarditis (one LLC) in 5 (4.8%), ischemia in 4 (3.8%), recent infarction in 2 (1.9%), old infarction in 4 (3.8%), dilated cardiomyopathy in 3 (2.9%), hypertrophic cardiomyopathy in 2 (1.9%), aortic stenosis, pleural tumor and mitral valve prolapse each in 1 (1.0%). Between May 2021 and August 2021, we examined an additional 27 patients with suspected cardiac disease after COVID-19 vaccination. Of these, CMR provided at least one diagnosis in 22 (81.5%): Isolated pericarditis in 4 (14.8%), acute myocarditis in 9 (33.3%), possible myocarditis (acute or subsided) in 6 (22.2%), ischemia in 3 (37.5% out of 8 patients with stress test), isolated pericardial effusion (> 10 mm) and non-compaction-cardiomyopathy each in 1 (3.7%). The number of myocarditis diagnoses after COVID-19 was highly dependent on the stringency of the myocarditis criteria applied. When including only cases of matching edema and LGE and excluding findings in the right ventricular insertion site, the number of cases dropped from 7 to 2 while the number of cases after COVID-19 vaccination remained unchanged at 9. While myocarditis is an overall rare side effect after COVID-19 vaccination, it is currently the leading cause of myocarditis in our institution due to the large number of vaccinations applied over the last months. Contrary to myocarditis after vaccination, LGE and edema in myocarditis after COVID-19 often did not match or were confined to the RV-insertion site. Whether these cases truly represent myocarditis or a different pathological entity is to be determined in further studies.


Subject(s)
COVID-19 , Myocarditis , Humans , COVID-19 Vaccines/adverse effects , Myocarditis/diagnostic imaging , Myocarditis/etiology , Post-Acute COVID-19 Syndrome , Predictive Value of Tests , Magnetic Resonance Spectroscopy
17.
Front Cardiovasc Med ; 8: 755759, 2021.
Article in English | MEDLINE | ID: mdl-34912862

ABSTRACT

Background: Cardiac magnetic resonance (CMR) pharmacological stress-testing is a well-established technique for detecting myocardial ischemia. Although stressors and contrast agents seem relatively safe, contraindications and side effects must be considered. Substantial costs are further limiting its applicability. Dynamic handgrip exercise (DHE) may have the potential to address these shortcomings as a physiological stressor. We therefore evaluated the feasibility and physiologic stress response of DHE in relation to pharmacological dobutamine-stimulation within the context of CMR examinations. Methods: Two groups were prospectively enrolled: (I) volunteers without relevant disease and (II) patients with known CAD referred for stress-testing. A both-handed, metronome-guided DHE was performed over 2 min continuously with 80 contractions/minute by all participants, whereas dobutamine stress-testing was only performed in group (II). Short axis strain by fast-Strain-ENCoded imaging was acquired at rest, immediately after DHE and during dobutamine infusion. Results: Eighty middle-aged individuals (age 56 ± 17 years, 48 men) were enrolled. DHE triggered significant positive chronotropic (HRrest: 68 ± 10 bpm, HRDHE: 91 ± 13 bpm, p < 0.001) and inotropic stress response (GLSrest: -19.4 ± 1.9%, GLSDHE: -20.6 ± 2.1%, p < 0.001). Exercise-induced increase of longitudinal strain was present in healthy volunteers and patients with CAD to the same extent, but in general more pronounced in the midventricular and apical layers (p < 0.01). DHE was aborted by a minor portion (7%) due to peripheral fatigue. The inotropic effect of DHE appears to be non-inferior to intermediate dobutamine-stimulation (GLSDHE= -19.5 ± 2.3%, GLSDob= -19.1 ± 3.1%, p = n.s.), whereas its chronotropic effect was superior (HRDHE= 89 ± 14 bpm, HRDob= 78 ± 15 bpm, p < 0.001). Conclusions: DHE causes positive ino- and chronotropic effects superior to intermediate dobutamine-stimulation, suggesting a relevant increase of myocardial oxygen demand. DHE appears to be safe and timesaving with broad applicability. The data encourages further studies to determine its potential to detect obstructive CAD.

18.
J Am Heart Assoc ; 10(17): e020351, 2021 09 07.
Article in English | MEDLINE | ID: mdl-34423658

ABSTRACT

Background Phenylketonuria is the most common inborn error of amino acid metabolism, where oxidative stress and collateral metabolic abnormalities are likely to cause cardiac structural and functional modifications. We aim herein to characterize the cardiac phenotype of adult subjects with phenylketonuria using advanced cardiac imaging. Methods and Results Thirty-nine adult patients with phenylketonuria (age, 30.5±8.7 years; 10-year mean phenylalanine concentration, 924±330 µmol/L) and 39 age- and sex-matched healthy controls were investigated. Participants underwent a comprehensive cardiac magnetic resonance and echocardiography examination. Ten-year mean plasma levels of phenylalanine and tyrosine were used to quantify disease activity and adherence to treatment. Patients with phenylketonuria had thinner left ventricular walls (septal end-diastolic thickness, 7.0±17 versus 8.8±1.7 mm [P<0.001]; lateral thickness, 6.1±1.4 versus 6.8±1.2 mm [P=0.004]), more dilated left ventricular cavity (end-diastolic volume, 87±14 versus 80±14 mL/m2 [P=0.0178]; end-systolic volume, 36±9 versus 29±8 mL/m2 [P<0.001]), lower ejection fraction (59±6% versus 64±6% [P<0.001]), reduced systolic deformation (global circumferential strain, -29.9±4.2 % versus -32.2±5.0 % [P=0.027]), and lower left ventricular mass (38.2±7.9 versus 47.8±11.0 g/m2 [P<0.001]). T1 native values were decreased (936±53 versus 996±26 ms [P<0.001]), with particular low values in patients with phenylalanine >1200 µmol/L (909±48 ms). Both mean phenylalanine (P=0.013) and tyrosine (P=0.035) levels were independently correlated with T1; and in a multiple regression model, higher phenylalanine levels and higher left ventricular mass associate with lower T1. Conclusions Cardiac phenotype of adult patients with phenylketonuria reveals some traits of an early-stage cardiomyopathy. Regular cardiology follow-up, tighter therapeutic control, and prophylaxis of cardiovascular risk factors, in particular dyslipidemia, are recommended.


Subject(s)
Cardiomyopathies , Phenylketonurias , Adult , Cardiomyopathies/diagnostic imaging , Humans , Magnetic Resonance Spectroscopy , Phenotype , Phenylalanine/blood , Phenylketonurias/complications , Tyrosine/blood , Young Adult
19.
Front Cardiovasc Med ; 8: 689255, 2021.
Article in English | MEDLINE | ID: mdl-34381823

ABSTRACT

Background: Myocardial efficiency should be maintained stable under light-to-moderate stress conditions, but ischemia puts the myocardium at risk for impaired functionality. Additionally, the measurement of such efficiency typically requires invasive heart catheterization and exposure to ionizing radiation. In this work, we aimed to non-invasively assess myocardial power and the resulting efficiency during pharmacological stress testing and ischemia induction. Methods: In a cohort of n = 10 healthy Landrace pigs, dobutamine stress testing was performed, followed by verapamil-induced ischemia alongside cardiac magnetic resonance (CMR) imaging. External myocardial power, internal myocardial power, and myocardial efficiency were assessed non-invasively using geometrical and functional parameters from CMR volumetric as well as blood flow and pressure measurements. Results: External myocardial power significantly increased under dobutamine stress [2.3 (1.6-3.1) W/m2 vs. 1.3 (1.1-1.6) W/m2, p = 0.005] and significantly decreased under verapamil-induced ischemia [0.8 (0.5-0.9) W/m2, p = 0.005]. Internal myocardial power [baseline: 5.9 (4.6-8.5) W/m2] was not affected by dobutamine [7.5 (6.9-9.0) W/m2, p = 0.241] nor verapamil [5.8 (4.7-8.8) W/m2, p = 0.878]. Myocardial efficiency did not change from baseline to dobutamine [21% (15-27) vs. 31% (20-44), p = 0.059] but decreased significantly during verapamil-induced ischemia [10% (8-13), p = 0.005]. Conclusion: In healthy Landrace pigs, dobutamine stress increased external myocardial power, whereas myocardial efficiency was maintained stable. On the contrary, verapamil-induced ischemia substantially decreased external myocardial power and myocardial efficiency. Non-invasive CMR was able to quantify these efficiency losses and might be useful for future clinical studies evaluating the effects of therapeutic interventions on myocardial energetics.

20.
Sci Rep ; 11(1): 12719, 2021 06 16.
Article in English | MEDLINE | ID: mdl-34135410

ABSTRACT

Transjugular intrahepatic portosystemic shunt (TIPS) reduces portal hypertension in patients with liver cirrhosis. The exact cardiac consequences of subsequent increase of central blood volume are unknown. Cardiovascular magnetic resonance (CMR) imaging is the method of choice for quantifying cardiac volumes and ventricular function. The aim of this study was to investigate effects of TIPS on the heart using CMR, laboratory, and imaging cardiac biomarkers. 34 consecutive patients with liver cirrhosis were evaluated for TIPS. Comprehensive CMR with native T1 mapping, transthoracic echocardiography, and laboratory biomarkers were assessed before and after TIPS insertion. Follow-up (FU) CMR was obtained in 16 patients (47%) 207 (170-245) days after TIPS. From baseline (BL) to FU, a significant increase of all indexed cardiac chamber volumes was observed (all P < 0.05). Left ventricular (LV) end-diastolic mass index increased significantly from 45 (38-51) to 65 (51-73) g/m2 (P = < 0.01). Biventricular systolic function, NT-proBNP, high-sensitive troponin T, and native T1 time did not differ significantly from BL to FU. No patient experienced cardiac decompensation following TIPS. In conclusion, in patients without clinically significant prior heart disease, increased cardiac preload after TIPS resulted in increased volumes of all cardiac chambers and eccentric LV hypertrophy, without leading to cardiac impairment during follow-up in this selected patient population.


Subject(s)
Heart/diagnostic imaging , Heart/physiopathology , Liver Cirrhosis/surgery , Portasystemic Shunt, Transjugular Intrahepatic , Aged , Cardiac Output , Cardiac Volume , Cardiomyopathies/diagnosis , Female , Heart Failure/diagnosis , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Portasystemic Shunt, Transjugular Intrahepatic/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...