Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Breast Cancer Res Treat ; 144(3): 583-9, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24570008

ABSTRACT

Phosphorus metabolite ratios are potential biomarkers in breast cancer diagnosis and treatment monitoring. Our purpose was to investigate the metabolite ratios phosphomonoester to phosphodiester, phosphoethanolamine (PE) to glycerophosphoethanolamine (GPE), and phosphocholine (PC) to glycerophosphocholine (GPC) in glandular breast tissue, and the potential effect of the menstrual cycle, using (31)P magnetic resonance spectroscopy (MRS) at 7T. Seven women with regular menstrual cycles each underwent four examinations using a 3D (31)P multi-echo magnetic resonance spectroscopic imaging sequence. Peak integrals were assessed using IDL and JMRUI software. First, T2 relaxation times were calculated using multi-echo data pooled across subjects and time points. Subsequent, metabolite ratios were calculated for each phase of the menstrual cycle using the calculated T2 values to account for when combining the free induction decay and all five echoes. The metabolite ratios were calculated both on group level and individually. T2 decay fits resulted in a T2 relaxation time for PE of 154 ms (95 % CI 144-164), for PC of 173 ms (95 % CI 148-205), for Pi of 188 ms (95 % CI 182-193), for GPE of 48 ms (95 % CI 44-53), and for GPC of 23 ms (95 % CI 21-26). The metabolite ratios analyzed on group level showed negligible variation throughout the menstrual cycle. Individual results did show an apparent intra-individual variation; however, not significant due to the measurements' uncertainty. To conclude, phospholipids in glandular tissue as measured with (31)P MRS at 7 T are not significantly affected by the menstrual cycle.


Subject(s)
Breast/metabolism , Magnetic Resonance Spectroscopy/methods , Menstrual Cycle/metabolism , Adult , Breast Neoplasms/diagnosis , Breast Neoplasms/metabolism , Female , Healthy Volunteers , Humans , Metabolomics/methods , Phosphorus/metabolism , Young Adult
2.
Eur Radiol ; 24(3): 603-9, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24078055

ABSTRACT

OBJECTIVE: To investigate the diagnostic value of 3-Tesla (T) breast MRI in patients presenting with microcalcifications on mammography. METHODS: Between January 2006 and May 2009, 123 patients with mammographically detected BI-RADS 3­5 microcalcifications underwent 3-T breast MRI before undergoing breast biopsy. All MRIs of the histopathologically confirmed index lesions were reviewed by two breast radiologists. The detection rate of invasive carcinoma and ductal carcinoma in situ (DCIS) was evaluated, as well as the added diagnostic value of MRI over mammography and breast ultrasound. RESULTS: At pathology, 40/123 (33%) lesions proved malignant; 28 (70%) DCIS and 12 (30%) invasive carcinoma. Both observers detected all invasive malignancies at MRI, as well as 79% (observer 1) and 86% (observer 2) of in situ lesions. MRI in addition to conventional imaging led to a significant increase in area under the receiver operating characteristic (ROC) curve from 0.67 (95% CI 0.56­0.79) to 0.79 (95% CI 0.70­0.88, observer 1) and to 0.80 (95% CI 0.71­0.89, observer 2), respectively. CONCLUSIONS: 3-T breast MRI was shown to add significant value to conventional imaging in patients presenting with suspicious microcalcifications on mammography. KEY POINTS: • 3-T MRI is increasingly used for breast imaging in clinical practice. • On 3-T breast MRI up to 86% of DCIS lesions are detected. • 3-T MRI increases the diagnostic value in patients with mammographically detected microcalcifications.


Subject(s)
Breast Neoplasms/pathology , Calcinosis/pathology , Carcinoma, Ductal, Breast/pathology , Carcinoma, Intraductal, Noninfiltrating/pathology , Magnetic Resonance Imaging/methods , Adult , Biopsy, Needle , Breast/pathology , Breast Neoplasms/diagnostic imaging , Calcinosis/diagnostic imaging , Carcinoma, Ductal, Breast/diagnostic imaging , Carcinoma, Intraductal, Noninfiltrating/diagnostic imaging , Female , Fibroadenoma/diagnostic imaging , Fibroadenoma/pathology , Fibrocystic Breast Disease/diagnostic imaging , Fibrocystic Breast Disease/pathology , Humans , Mammography , Middle Aged , Neoplasm Invasiveness , ROC Curve , Ultrasonography, Mammary
3.
NMR Biomed ; 26(10): 1299-307, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23553945

ABSTRACT

An adiabatic multi-echo spectroscopic imaging (AMESING) sequence, used for (31) P MRSI, with spherical k-space sampling and compensated phase-encoding gradients, was implemented on a whole-body 7-T MR system. One free induction decay (FID) and up to five symmetric echoes can be acquired with this sequence. In tissues with low T2 and high T2 , this can theoretically lead to a potential maximum signal-to-noise ratio (SNR) increase of almost a factor of three, compared with a conventional FID acquisition with Ernst-angle excitation. However, with T2 values being, in practice, ≤400 ms, a maximum enhancement of approximately two compared with low flip Ernst-angle excitation should be feasible. The multi-echo sequence enables the determination of localized T2 values, and was validated with (31) P three-dimensional MRSI on the calf muscle and breast of a healthy volunteer, and subsequently applied in a patient with breast cancer. The T2 values of phosphocreatine, phosphodiesters (PDE) and inorganic phosphate in calf muscle were 193 ± 5 ms, 375 ± 44 ms and 96 ± 10 ms, respectively, and the apparent T2 value of γ-ATP was 25 ± 6 ms. A T2 value of 136 ± 15 ms for inorganic phosphate was measured in glandular breast tissue of a healthy volunteer. The T2 values of phosphomonoesters (PME) and PDE in breast cancer tissue (ductulolobular carcinoma) ranged between 170 and 210 ms, and the PME to PDE ratios were calculated to be phosphoethanolamine/glycerophosphoethanolamine = 2.7, phosphocholine/glycerophosphocholine = 1.8 and PME/PDE = 2.3. Considering the relatively short T2 values of the metabolites in breast tissue at 7 T, the echo spacing can be short without compromising spectral resolution, whilst maximizing the sensitivity.


Subject(s)
Breast/anatomy & histology , Magnetic Resonance Spectroscopy , Muscles/anatomy & histology , Phosphorus/metabolism , Adiposity , Female , Humans , Male , Middle Aged , Signal-To-Noise Ratio , Time Factors , Water
4.
NMR Biomed ; 26(4): 367-75, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23076877

ABSTRACT

There is a need to obtain higher specificity in the detection of breast lesions using MRI. To address this need, Dynamic Contrast-Enhanced (DCE) MRI has been combined with other structural and functional MRI techniques. Unfortunately, owing to time constraints structural images at ultra-high spatial resolution can generally not be obtained during contrast uptake, whereas the relatively low spatial resolution of functional imaging (e.g. diffusion and perfusion) limits the detection of small lesions. To be able to increase spatial as well as temporal resolution simultaneously, the sensitivity of MR detection needs to increase as well as the ability to effectively accelerate the acquisition. The required gain in signal-to-noise ratio (SNR) can be obtained at 7T, whereas acceleration can be obtained with high-density receiver coil arrays. In this case, morphological imaging can be merged with DCE-MRI, and other functional techniques can be obtained at higher spatial resolution, and with less distortion [e.g. Diffusion Weighted Imaging (DWI)]. To test the feasibility of this concept, we developed a unilateral breast coil for 7T. It comprises a volume optimized dual-channel transmit coil combined with a 30-channel receive array coil. The high density of small coil elements enabled efficient acceleration in any direction to acquire ultra high spatial resolution MRI of close to 0.6 mm isotropic detail within a temporal resolution of 69 s, high spatial resolution MRI of 1.5 mm isotropic within an ultra high temporal resolution of 6.7 s and low distortion DWI at 7T, all validated in phantoms, healthy volunteers and a patient with a lesion in the right breast classified as Breast Imaging Reporting and Data System (BI-RADS) IV.


Subject(s)
Breast/anatomy & histology , Magnetic Resonance Imaging/methods , Acceleration , Adult , Contrast Media , Female , Humans , Radio Waves , Signal-To-Noise Ratio , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...