Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Am J Cardiol ; 207: 370-379, 2023 11 15.
Article in English | MEDLINE | ID: mdl-37778226

ABSTRACT

The EVOLVE Short DAPT study demonstrated the safety of truncated dual antiplatelet therapy (DAPT) in patients with a high bleeding risk (HBR) treated with SYNERGY stent(s) (Boston Scientific Company, Marlborough, Massachusetts). In this population, bleeding and ischemic risk prediction may further inform DAPT decisions. This post hoc analysis of the EVOLVE Short DAPT study identified predictors of ischemic and bleeding events up to 15 months using Cox proportional hazard models. The predicted probabilities of bleeding were calculated using the Breslow method. Of 2,009 enrolled patients, 96.9% of the patients met at least 1 HBR criteria. At 15 months, the cumulative incidences of bleeding and ischemic events were 6.3% and 6.0%, respectively. The risk of bleeding was increased in patients who received oral anticoagulants (hazard ratio [HR] 2.24, 95% confidence interval [CI] 1.50 to 3.36, p <0.001) or had peripheral vascular disease (HR 1.61, 95% CI 1.01 to 2.56, p = 0.045). The risk of ischemic events was increased in patients with diabetes (HR 1.86, 95% CI 1.24 to 2.78, p <0.01) or congestive heart failure (HR 2.06, 95% CI 1.39 to 3.04, p <0.001). Renal insufficiency/failure was associated with both endpoints. There was a strong positive correlation between the predicted probability of ischemic and bleeding events (R = 0.77, p <0.001). In 617 patients with a predicted bleeding risk <4%, ischemic events predominated, and the ischemic and bleeding rates were higher in patients with a predicted bleeding risk ≥4%. Within an HBR cohort, specific characteristics identify patients at a higher risk for ischemic and separately, bleeding events. Increased bleeding risk is tied to increased ischemic risk. In conclusion, standardized risk models are needed to inform DAPT decisions in patients with a higher risk. Clinical Trial Registration: NCT02605447.


Subject(s)
Dual Anti-Platelet Therapy , Hemorrhage , Humans , Drug Therapy, Combination , Dual Anti-Platelet Therapy/adverse effects , Dual Anti-Platelet Therapy/methods , Hemorrhage/chemically induced , Hemorrhage/epidemiology , Incidence , Platelet Aggregation Inhibitors/therapeutic use , Stents , Treatment Outcome
2.
J Am Coll Cardiol ; 82(3): 183-195, 2023 07 18.
Article in English | MEDLINE | ID: mdl-37207924

ABSTRACT

BACKGROUND: Bioresorbable vascular scaffolds (BVS) were designed to improve late event-free survival compared with metallic drug-eluting stents. However, initial trials demonstrated worse early outcomes with BVS, in part due to suboptimal technique. In the large-scale, blinded ABSORB IV trial, polymeric everolimus-eluting BVS implanted with improved technique demonstrated noninferior 1-year outcomes compared with cobalt chromium everolimus-eluting stents (CoCr-EES). OBJECTIVES: This study sought to evaluate the long-term outcomes from the ABSORB IV trial. METHODS: We randomized 2,604 patients at 147 sites with stable or acute coronary syndromes to BVS with improved technique vs CoCr-EES. Patients, clinical assessors, and event adjudicators were blinded to randomization. Five-year follow-up was completed. RESULTS: Target lesion failure at 5 years occurred in 216 (17.5%) patients assigned to BVS and 180 (14.5%) patients assigned to CoCr-EES (P = 0.03). Device thrombosis within 5 years occurred in 21 (1.7%) BVS and 13 (1.1%) CoCr-EES patients (P = 0.15). Event rates were slightly greater with BVS than CoCr-EES through 3-year follow-up and were similar between 3 and 5 years. Angina, also centrally adjudicated, recurred within 5 years in 659 patients (cumulative rate 53.0%) assigned to BVS and 674 (53.3%) patients assigned to CoCr-EES (P = 0.63). CONCLUSIONS: In this large-scale, blinded randomized trial, despite the improved implantation technique, the absolute 5-year rate of target lesion failure was 3% greater after BVS compared with CoCr-EES. The risk period for increased events was limited to 3 years, the time point of complete scaffold bioresorption; event rates were similar thereafter. Angina recurrence after intervention was frequent during 5-year follow-up but was comparable with both devices.(Absorb IV Randomized Controlled Trial; NCT02173379).


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Humans , Absorbable Implants , Everolimus , Prosthesis Design , Stents , Tissue Scaffolds , Treatment Outcome
4.
Circ Cardiovasc Interv ; 12(9): e008152, 2019 09.
Article in English | MEDLINE | ID: mdl-31451014

ABSTRACT

BACKGROUND: The thin-strut SYNERGY stent has an abluminal everolimus-eluting bioabsorbable polymer coating designed to facilitate vascular healing and reduce risk of stent thrombosis. In the multicenter, randomized EVOLVE II trial (The EVOLVE II Clinical Trial to Assess the SYNERGY Stent System for the Treatment of Atherosclerotic Lesion[s]), SYNERGY was noninferior to the durable polymer PROMUS Element Plus everolimus-eluting stent for the primary end point of 1-year target lesion failure. Longer-term clinical follow-up will support the relative efficacy and safety of SYNERGY. METHODS: Patients with ≤3 native coronary lesions (reference vessel diameter ≥2.25-≤4.00 mm; length ≤34 mm) in ≤2 major epicardial vessels were randomized 1:1 to SYNERGY (N=838) or PROMUS Element Plus (N=846). EVOLVE II included a Diabetes substudy which pooled patients with diabetes mellitus from the randomized controlled trial (n=263) and from a sequential, single-arm substudy (N=203). RESULTS: The 5-year target lesion failure rate was 14.3% for SYNERGY and 14.2% for PROMUS Element Plus (P=0.91). Landmark analysis demonstrated similar rates of target lesion failure from discharge to 1-year (P=0.90) and from 1 to 5 years (P=0.94). Definite/probable stent thrombosis was infrequent in both arms (SYNERGY 0.7% versus PROMUS Element Plus 0.9%; P=0.75). There were no significant differences in the rates of cardiac death, myocardial infarction, or revascularization. Among patients with diabetes mellitus, the target lesion failure rate to 1-year was noninferior to a prespecified performance goal and to 5 years was 17.0%. CONCLUSIONS: SYNERGY demonstrated comparable outcomes to PROMUS Element Plus, with low rates of stent thrombosis and adverse events through 5 years of follow-up. Five-year clinical outcomes were favorable in patients with diabetes mellitus. These data support the long-term safety and effectiveness of SYNERGY in a broad range of patients. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01665053.


Subject(s)
Absorbable Implants , Cardiovascular Agents/administration & dosage , Coronary Artery Disease/therapy , Diabetes Mellitus/therapy , Drug-Eluting Stents , Everolimus/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Polymers , Aged , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Diabetes Mellitus/diagnosis , Diabetes Mellitus/mortality , Everolimus/adverse effects , Female , Humans , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Risk Factors , Time Factors , Treatment Outcome
5.
Lancet ; 392(10157): 1530-1540, 2018 10 27.
Article in English | MEDLINE | ID: mdl-30266412

ABSTRACT

BACKGROUND: Previous studies showed more adverse events with coronary bioresorbable vascular scaffolds (BVS) than with metallic drug-eluting stents (DES), although in one randomised trial angina was reduced with BVS. However, these early studies were unmasked, lesions smaller than intended for the scaffold were frequently enrolled, implantation technique was suboptimal, and patients with myocardial infarction, in whom BVS might be well suited, were excluded. METHODS: In the active-controlled, blinded, multicentre, randomised ABSORB IV trial, patients with stable coronary artery disease or acute coronary syndromes aged 18 years or older were recruited from 147 hospitals in five countries (the USA, Germany, Australia, Singapore, and Canada). Enrolled patients were randomly assigned (1:1) to receive polymeric everolimus-eluting BVS (Absorb; Abbott Vascular, Santa Clara, CA, USA) with optimised implantation technique or cobalt-chromium everolimus-eluting stents (EES; Xience; Abbott Vascular, Santa Clara, CA, USA). Randomisation was stratified by diabetic status, whether patients would have been eligible for enrolment in the previous ABSORB III trial, and site. Patients and clinical assessors were masked to randomisation. The primary endpoint was target lesion failure (cardiac death, target vessel myocardial infarction, or ischaemia-driven target lesion revascularisation) at 30 days, tested for non-inferiority with a 2·9% margin for the risk difference. Analysis was by intention to treat. The trial is registered with ClinicalTrials.gov, number NCT02173379, and is closed to accrual. FINDINGS: Between Aug 15, 2014, and March 31, 2017, we screened 18 722 patients for eligibility, 2604 of whom were enrolled. 1296 patients were assigned to BVS, and 1308 patients were assigned to EES. Follow-up data at 30 days and 1 year, respectively, were available for 1288 and 1254 patients with BVS and for 1303 and 1272 patients with EES. Biomarker-positive acute coronary syndromes were present in 622 (24%) of 2602 patients, and, by angiographic core laboratory analysis, 78 (3%) of 2893 of lesions were in very small vessels. Target lesion failure at 30 days occurred in 64 (5·0%) patients assigned to BVS and 48 (3·7%) patients assigned to EES (difference 1·3%, upper 97·5% confidence limit 2·89; one-sided pnon-inferiority=0·0244). Target lesion failure at 1 year occurred in 98 (7·8%) patients assigned to BVS and 82 (6·4%) patients assigned to EES (difference 1·4%, upper 97·5% confidence limit 3·4; one-sided pnon-inferiority=0·0006). Angina, adjudicated by a central events committee at 1 year, occurred in 270 (20·3%) patients assigned to BVS and 274 (20·5%) patients assigned to EES (difference -0·3%, 95% CI -3·4% to 2·9%; one-sided pnon-inferiority=0·0008; two-sided psuperiority=0·8603). Device thrombosis within 1 year occurred in nine (0·7%) patients assigned to BVS and four (0·3%) patients assigned to EES (p=0·1586). INTERPRETATION: Polymeric BVS implanted with optimised technique in an expanded patient population resulted in non-inferior 30-day and 1-year rates of target lesion failure and angina compared with metallic DES. FUNDING: Abbott Vascular.


Subject(s)
Absorbable Implants , Coronary Artery Disease/therapy , Tissue Scaffolds , Acute Coronary Syndrome/therapy , Aged , Biocompatible Materials , Coronary Artery Disease/pathology , Double-Blind Method , Drug-Eluting Stents , Everolimus/administration & dosage , Female , Follow-Up Studies , Humans , Immunosuppressive Agents/administration & dosage , Kaplan-Meier Estimate , Male , Middle Aged , Treatment Outcome
6.
EuroIntervention ; 12(16): 1987-1994, 2017 Mar 20.
Article in English | MEDLINE | ID: mdl-27840326

ABSTRACT

AIMS: Bioabsorbable polymer drug-eluting stents (DES) may reduce the inflammation and delayed healing associated with some permanent polymer-coated DES. Whether late clinical outcomes are improved, particularly among patients with medically treated diabetes, is unknown. Therefore, we analysed outcomes from a pre-specified substudy of the EVOLVE II trial to evaluate the safety and effectiveness of the SYNERGY stent in patients with diabetes mellitus. METHODS AND RESULTS: SYNERGY is a thin-strut, platinum-chromium everolimus-eluting stent with an ultra-thin bioabsorbable poly(DL-lactide-co-glycolide) abluminal polymer. The EVOLVE II randomised, controlled trial proved the non-inferiority of the SYNERGY versus the PROMUS Element Plus stent for one-year target lesion failure (TLF: ischaemia-driven target lesion revascularisation [ID-TLR], target vessel myocardial infarction [TVMI], or cardiac death). The pre-specified EVOLVE II diabetes substudy prospectively pooled randomised patients with diabetes (N=263) with a sequential single-arm diabetic cohort (n=203). The substudy primary endpoint was one-year TLF compared with a pre-specified performance goal (14.5%). The primary endpoint occurred in 7.5% of SYNERGY-treated patients with diabetes, significantly less than the performance goal (p<0.0001). The two-year rate of TLF was 11.2% (cardiac death 1.5%, TVMI 6.4%, ID-TLR 6.8%) and definite/probable stent thrombosis occurred in 1.1% of patients. CONCLUSIONS: The EVOLVE II diabetes substudy demonstrates the efficacy and safety of the SYNERGY stent in patients with medically treated diabetes.


Subject(s)
Absorbable Implants , Diabetes Complications , Diabetes Mellitus , Drug-Eluting Stents , Everolimus/therapeutic use , Myocardial Infarction/surgery , Sirolimus/therapeutic use , Absorbable Implants/adverse effects , Aged , Aged, 80 and over , Death , Drug-Eluting Stents/adverse effects , Everolimus/adverse effects , Female , Humans , Male , Middle Aged , Myocardial Infarction/complications , Percutaneous Coronary Intervention/methods , Polymers/adverse effects , Treatment Outcome
7.
IEEE J Biomed Health Inform ; 20(1): 256-67, 2016 Jan.
Article in English | MEDLINE | ID: mdl-25561598

ABSTRACT

BACKGROUND: Pixel-level tissue classification for ultrasound images, commonly applied to carotid images, is usually based on defining thresholds for the isolated pixel values. Ranges of pixel values are defined for the classification of each tissue. The classification of pixels is then used to determine the carotid plaque composition and, consequently, to determine the risk of diseases (e.g., strokes) and whether or not a surgery is necessary. The use of threshold-based methods dates from the early 2000s but it is still widely used for virtual histology. METHODOLOGY/PRINCIPAL FINDINGS: We propose the use of descriptors that take into account information about a neighborhood of a pixel when classifying it. We evaluated experimentally different descriptors (statistical moments, texture-based, gradient-based, local binary patterns, etc.) on a dataset of five types of tissues: blood, lipids, muscle, fibrous, and calcium. The pipeline of the proposed classification method is based on image normalization, multiscale feature extraction, including the proposal of a new descriptor, and machine learning classification. We have also analyzed the correlation between the proposed pixel classification method in the ultrasound images and the real histology with the aid of medical specialists. CONCLUSIONS/SIGNIFICANCE: The classification accuracy obtained by the proposed method with the novel descriptor in the ultrasound tissue images (around 73%) is significantly above the accuracy of the state-of-the-art threshold-based methods (around 54%). The results are validated by statistical tests. The correlation between the virtual and real histology confirms the quality of the proposed approach showing it is a robust ally for the virtual histology in ultrasound images.


Subject(s)
Image Processing, Computer-Assisted/methods , Ultrasonography/methods , Aged , Aged, 80 and over , Blood/diagnostic imaging , Calcium/chemistry , Carotid Arteries/diagnostic imaging , Carotid Artery Diseases/diagnostic imaging , Female , Humans , Lipids/chemistry , Male , Middle Aged , Muscle, Skeletal/diagnostic imaging , Support Vector Machine
8.
Comput Biol Med ; 66: 66-81, 2015 Nov 01.
Article in English | MEDLINE | ID: mdl-26386547

ABSTRACT

In this paper, we explore mid-level image representations for real-time heart view plane classification of 2D echocardiogram ultrasound images. The proposed representations rely on bags of visual words, successfully used by the computer vision community in visual recognition problems. An important element of the proposed representations is the image sampling with large regions, drastically reducing the execution time of the image characterization procedure. Throughout an extensive set of experiments, we evaluate the proposed approach against different image descriptors for classifying four heart view planes. The results show that our approach is effective and efficient for the target problem, making it suitable for use in real-time setups. The proposed representations are also robust to different image transformations, e.g., downsampling, noise filtering, and different machine learning classifiers, keeping classification accuracy above 90%. Feature extraction can be performed in 30 fps or 60 fps in some cases. This paper also includes an in-depth review of the literature in the area of automatic echocardiogram view classification giving the reader a through comprehension of this field of study.


Subject(s)
Echocardiography/methods , Heart/physiology , Myocardium/pathology , Algorithms , Humans , Image Processing, Computer-Assisted , Machine Learning , Models, Statistical , Pattern Recognition, Automated , ROC Curve , Reproducibility of Results
9.
Circ Cardiovasc Interv ; 8(4)2015 Apr.
Article in English | MEDLINE | ID: mdl-25855680

ABSTRACT

BACKGROUND: Drug eluting stents with durable polymers may be associated with hypersensitivity, delayed healing, and incomplete endothelialization, which may contribute to late/very late stent thrombosis and the need for prolonged dual antiplatelet therapy. Bioabsorbable polymers may facilitate stent healing, thus enhancing clinical safety. The SYNERGY stent is a thin-strut, platinum chromium metal alloy platform with an ultrathin bioabsorbable Poly(D,L-lactide-co-glycolide) abluminal everolimus-eluting polymer. We performed a multicenter, randomized controlled trial for regulatory approval to determine noninferiority of the SYNERGY stent to the durable polymer PROMUS Element Plus everolimus-eluting stent. METHODS AND RESULTS: Patients (n=1684) scheduled to undergo percutaneous coronary intervention for non-ST-segment-elevation acute coronary syndrome or stable coronary artery disease were randomized to receive either the SYNERGY stent or the PROMUS Element Plus stent. The primary end point of 12-month target lesion failure was observed in 6.7% of SYNERGY and 6.5% PROMUS Element Plus treated subjects by intention-to-treat (P=0.83 for difference; P=0.0005 for noninferiority), and 6.4% in both the groups by per-protocol analysis (P=0.0003 for noninferiority). Clinically indicated revascularization of the target lesion or definite/probable stent thrombosis were observed in 2.6% versus 1.7% (P=0.21) and 0.4% versus 0.6% (P=0.50) of SYNERGY versus PROMUS Element Plus-treated subjects, respectively. CONCLUSIONS: In this randomized trial, the SYNERGY bioabsorbable polymer everolimus-eluting stent was noninferior to the PROMUS Element Plus everolimus-eluting stent with respect to 1-year target lesion failure. These data support the relative safety and efficacy of SYNERGY in a broad range of patients undergoing percutaneous coronary intervention. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01665053.


Subject(s)
Absorbable Implants/statistics & numerical data , Acute Coronary Syndrome/surgery , Biocompatible Materials/administration & dosage , Blood Vessel Prosthesis Implantation , Coronary Artery Disease/surgery , Everolimus/administration & dosage , Percutaneous Coronary Intervention , Absorbable Implants/adverse effects , Aged , Biocompatible Materials/adverse effects , Biocompatible Materials/chemistry , Dioxanes , Drug-Eluting Stents/statistics & numerical data , Everolimus/adverse effects , Female , Follow-Up Studies , Humans , Male , Middle Aged , Platinum Compounds , Polymers/administration & dosage , Polymers/adverse effects , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...