Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMJ Case Rep ; 16(11)2023 Nov 08.
Article in English | MEDLINE | ID: mdl-37940197

ABSTRACT

An internal hernia through the foramen of Winslow represents a rare surgical pathology. This report describes a case with incipient caecal ischaemia and discusses current diagnostic and therapeutic approaches. A patient in his early 60s presented at the emergency department with abdominal pain and last bowel movement three days prior. A CT scan of the abdomen suggested an internal hernia into the lesser sac. Intraoperatively, the suspected diagnosis could be confirmed laparoscopically with a twisted mobile caecum herniating through the foramen of Winslow. Due to a suspected ischaemia and laparoscopic frustrated reduction, a right open hemicolectomy was performed. The hernia gap was closed. The postoperative course was uneventful. Despite the rarity of internal hernias in patients without prior abdominal surgery, surgeons should be aware of this entity. The diagnosis can be difficult and sometimes only established intraoperatively. Open surgery is usually required. If the gap is clearly identified, the recommendations tend towards its closure.


Subject(s)
Cecal Diseases , Hernia, Abdominal , Intestinal Obstruction , Humans , Hernia, Abdominal/complications , Hernia, Abdominal/diagnostic imaging , Hernia, Abdominal/surgery , Hernia/complications , Hernia/diagnostic imaging , Intestinal Obstruction/diagnostic imaging , Intestinal Obstruction/etiology , Intestinal Obstruction/surgery , Cecum/diagnostic imaging , Cecum/surgery , Cecal Diseases/complications , Cecal Diseases/diagnostic imaging , Cecal Diseases/surgery , Internal Hernia
2.
Minerva Anestesiol ; 88(3): 121-128, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34527406

ABSTRACT

BACKGROUND: Double-lumen endobronchial tubes (DLT) continue to be the most widely used method for obtaining lung isolation during anesthesia. We compared recommendations for DLT size selection with radiologically assessed lower airway dimensions gathered from a large patient population. METHODS: For this retrospective comparative study, we assessed computed tomography (CT) scans of 150 adults with no known airway pathologies. Using these scans, we measured the diameter and length of the trachea and the diameter of the mainstem bronchi. These airway dimensions were then compared to the dimensions of left-sided DLTs of three different manufacturers. Size selection was based on one standard textbook's recommendations. RESULTS: We found the recommended DLT sizes were occasionally too small but more often too large, particularly in the endobronchial airway. With the DLT Vivasight-DL®, mismatching occurred in 28.7% (43/150) of the patients at the distal mainstem bronchus and 8% (12/150) at the tracheal level. This mismatching happened most often in females (left distal mainstem bronchus 34/68, 50%; trachea 9/68, 13.2%). Conversely, the DLT was more often too small for male patients in both the left main bronchus (SHER-I-BRONCH®: 8/82, 9.8%) and the trachea (SHER-I-BRONCH®: 2/82, 2.4%). The endobronchial tube portion was more often too long in females (Vivasight® DLT: 11/68, 16%) than males (9/82, 11%). CONCLUSIONS: A considerable proportion of the recommended DLT sizes from all three manufacturers was incompatible with individual patient's lower airway dimensions.


Subject(s)
Intubation, Intratracheal , Trachea , Adult , Bronchi/diagnostic imaging , Female , Humans , Intubation, Intratracheal/methods , Lung , Male , Retrospective Studies , Trachea/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...