Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Bioengineering (Basel) ; 11(4)2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38671723

ABSTRACT

Chronic obstructive pulmonary disease (COPD) is one of the leading causes of death. Recent studies have underlined the importance of non-contrast-enhanced chest CT scans not only for emphysema progression quantification, but for correlation with clinical outcomes as well. As about 40 percent of the 300 million CT scans per year are contrast-enhanced, no proper emphysema quantification is available in a one-stop-shop approach for patients with known or newly diagnosed COPD. Since the introduction of spectral imaging (e.g., dual-energy CT scanners), it has been possible to create virtual non-contrast-enhanced images (VNC) from contrast-enhanced images, making it theoretically possible to offer proper COPD imaging despite contrast enhancing. This study is aimed towards investigating whether these VNC images are comparable to true non-contrast-enhanced images (TNC), thereby reducing the radiation exposure of patients and usage of resources in hospitals. In total, 100 COPD patients with two scans, one with (VNC) and one without contrast media (TNC), within 8 weeks or less obtained by a spectral CT using dual-layer technology, were included in this retrospective study. TNC and VNC were compared according to their voxel-density histograms. While the comparison showed significant differences in the low attenuated volumes (LAVs) of TNC and VNC regarding the emphysema threshold of -950 Houndsfield Units (HU), the 15th and 10th percentiles of the LAVs used as a proxy for pre-emphysema were comparable. Upon further investigation, the threshold-based LAVs (-950 HU) of TNC and VNC were comparable in patients with a water equivalent diameter (DW) below 270 mm. The study concludes that VNC imaging may be a viable option for assessing emphysema progression in COPD patients, particularly those with a normal body mass index (BMI). Further, pre-emphysema was generally comparable between TNC and VNC. This approach could potentially reduce radiation exposure and hospital resources by making additional TNC scans obsolete.

2.
Bioengineering (Basel) ; 11(3)2024 Feb 22.
Article in English | MEDLINE | ID: mdl-38534481

ABSTRACT

CT protocols that diagnose COVID-19 vary in regard to the associated radiation exposure and the desired image quality (IQ). This study aims to evaluate CT protocols of hospitals participating in the RACOON (Radiological Cooperative Network) project, consolidating CT protocols to provide recommendations and strategies for future pandemics. In this retrospective study, CT acquisitions of COVID-19 patients scanned between March 2020 and October 2020 (RACOON phase 1) were included, and all non-contrast protocols were evaluated. For this purpose, CT protocol parameters, IQ ratings, radiation exposure (CTDIvol), and central patient diameters were sampled. Eventually, the data from 14 sites and 534 CT acquisitions were analyzed. IQ was rated good for 81% of the evaluated examinations. Motion, beam-hardening artefacts, or image noise were reasons for a suboptimal IQ. The tube potential ranged between 80 and 140 kVp, with the majority between 100 and 120 kVp. CTDIvol was 3.7 ± 3.4 mGy. Most healthcare facilities included did not have a specific non-contrast CT protocol. Furthermore, CT protocols for chest imaging varied in their settings and radiation exposure. In future, it will be necessary to make recommendations regarding the required IQ and protocol parameters for the majority of CT scanners to enable comparable IQ as well as radiation exposure for different sites but identical diagnostic questions.

3.
Diagnostics (Basel) ; 14(3)2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38337812

ABSTRACT

BACKGROUND: Economic restrictions and workforce cuts have continually challenged conventional autopsies. Recently, the COVID-19 pandemic has added tissue quality and safety requirements to the investigation of this disease, thereby launching efforts to upgrade autopsy strategies. METHODS: In this proof-of-concept study, we performed bedside ultrasound-guided minimally invasive autopsy (US-MIA) in the ICU of critically ill COVID-19 patients using a structured protocol to obtain non-autolyzed tissue. Biopsies were assessed for their quality (vitality) and length of biopsy (mm) and for diagnosis. The efficiency of the procedure was monitored in five cases by recording the time of each step and safety issues by swabbing personal protective equipment and devices for viral contamination. FINDINGS: Ultrasound examination and tissue procurement required a mean time period of 13 min and 54 min, respectively. A total of 318 multiorgan biopsies were obtained from five patients. Quality and vitality standards were fulfilled, which not only allowed for specific histopathological diagnosis but also the reliable detection of SARS-CoV-2 virions in unexpected organs using electronic microscopy and RNA-expressing techniques. INTERPRETATION: Bedside multidisciplinary US-MIA allows for the fast and efficient acquisition of autolytic-free tissue and offers unappreciated potential to overcome the limitations of research in postmortem studies.

4.
J Clin Med ; 12(23)2023 Nov 26.
Article in English | MEDLINE | ID: mdl-38068377

ABSTRACT

Percutaneous CT-guided biopsy is a frequently performed procedure for the confirmation and molecular workup of hepatic metastases of pancreatic ductal adenocarcinoma (PDAC). Tumor necrosis of primary PDAC has shown a negative prognostic impact in recent studies. This study aims to examine predictability in CT scans and the prognostic impact of necrosis in hepatic metastases of PDAC. In this tertiary-center retrospective cohort study, we included 36 patients with hepatic metastases of PDAC who underwent CT-guided hepatic biopsies. Normalized attenuation of the biopsied metastasis was determined in venous phase contrast-enhanced planning scans obtained prior to biopsy by automatic, threshold-based 3D segmentation and manual, blinded 2D segmentation. A board-certified pathologist specialized in hepatic pathology histologically quantified the tumor necrosis and cellularity of the biopsy cylinders. We found a significant inverse-linear correlation between normalized attenuation and the fraction of necrosis (Pearson's r = 0.51, p < 0.001 for automatic 3D segmentation or Pearson's r = 0.52, p < 0.001 for manual 2D segmentation), whereas no correlation was found with tumor cellularity. Additionally, we discovered that patients with a fraction of necrosis ≥ 20% in metastases had a significantly shorter overall survival (p < 0.035). In summary, tumor necrosis of PDAC metastases can be estimated from contrast-enhanced CT scans, which could help to improve biopsy sample pattern planning. In addition, liver metastatic necrosis may serve as a prognostic biomarker in PDAC.

5.
Crit Care ; 27(1): 201, 2023 05 26.
Article in English | MEDLINE | ID: mdl-37237287

ABSTRACT

BACKGROUND: A quantitative assessment of pulmonary edema is important because the clinical severity can range from mild impairment to life threatening. A quantitative surrogate measure, although invasive, for pulmonary edema is the extravascular lung water index (EVLWI) extracted from the transpulmonary thermodilution (TPTD). Severity of edema from chest X-rays, to date is based on the subjective classification of radiologists. In this work, we use machine learning to quantitatively predict the severity of pulmonary edema from chest radiography. METHODS: We retrospectively included 471 X-rays from 431 patients who underwent chest radiography and TPTD measurement within 24 h at our intensive care unit. The EVLWI extracted from the TPTD was used as a quantitative measure for pulmonary edema. We used a deep learning approach and binned the data into two, three, four and five classes increasing the resolution of the EVLWI prediction from the X-rays. RESULTS: The accuracy, area under the receiver operating characteristic curve (AUROC) and Mathews correlation coefficient (MCC) in the binary classification models (EVLWI < 15, ≥ 15) were 0.93 (accuracy), 0.98 (AUROC) and 0.86(MCC). In the three multiclass models, the accuracy ranged between 0.90 and 0.95, the AUROC between 0.97 and 0.99 and the MCC between 0.86 and 0.92. CONCLUSION: Deep learning can quantify pulmonary edema as measured by EVLWI with high accuracy.


Subject(s)
Deep Learning , Pulmonary Edema , Humans , Pulmonary Edema/diagnostic imaging , Pulmonary Edema/etiology , X-Rays , Retrospective Studies , Extravascular Lung Water/diagnostic imaging , Radiography , Thermodilution
6.
Front Endocrinol (Lausanne) ; 11: 570560, 2020.
Article in English | MEDLINE | ID: mdl-33117285

ABSTRACT

Aging in women is associated with low estrogen, but also with cognitive decline and affective disorders. Whether low estrogen is causally responsible for these behavioral symptoms is not clear. Thus, we aimed to examine the role of estradiol in anxiety-like behavior and memory in rats at middle age. Twelve-month old female rats underwent ovariectomy (OVX) or were treated with 1 mg/kg of letrozole-an aromatase inhibitor. In half of the OVX females, 10 µg/kg of 17ß-estradiol was supplemented daily for 4 weeks. Vehicle-treated sham-operated and OVX females served as controls. For behavioral assessment open field, elevated plus maze and novel object recognition tests were performed. Interaction between ovarian condition and additional treatment had the main effect on anxiety-like behavior of rats in the open field test. In comparison to control females, OVX females entered less frequently into the center zone of the open field (p < 0.01) and showed lower novel object discrimination (p = 0.05). However, estradiol-supplemented OVX rats had higher number of center-zone entries (p < 0.01), spent more time in the center zone (p < 0.05), and showed lower thigmotaxis (p < 0.01) when compared to OVX group. None of the hormonal manipulations affected anxiety-like behavior in the elevated plus maze test significantly, but a mild effect of interaction between ovarian condition and treatment was shown (p = 0.05). In conclusion, ovariectomy had slight negative effect on open-field ambulation and short-term recognition memory in middle-aged rats. In addition, a test-specific anxiolytic effect of estradiol supplementation was found. In contrast, letrozole treatment neither affected anxiety-like behavior nor memory.


Subject(s)
Aging/blood , Anxiety/blood , Estradiol/administration & dosage , Estrogens/blood , Memory/physiology , Age Factors , Aging/drug effects , Animals , Anxiety/drug therapy , Anxiety/psychology , Aromatase Inhibitors/administration & dosage , Female , Letrozole/administration & dosage , Maze Learning/drug effects , Maze Learning/physiology , Memory/drug effects , Ovariectomy/adverse effects , Ovariectomy/trends , Rats , Rats, Wistar
SELECTION OF CITATIONS
SEARCH DETAIL
...