Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 87(6): 063905, 2016 Jun.
Article in English | MEDLINE | ID: mdl-27370468

ABSTRACT

In this paper we describe a setup for x-ray scattering experiments on complex fluids using a liquid jet. The setup supports Small and Wide Angle X-ray Scattering (SAXS/WAXS) geometries. The jet is formed by a gas-dynamic virtual nozzle (GDVN) allowing for diameters ranging between 1 µm and 20 µm at a jet length of several hundred µm. To control jet properties such as jet length, diameter, or flow rate, the instrument is equipped with several diagnostic tools. Three microscopes are installed to quantify jet dimensions and stability in situ. The setup has been used at several beamlines performing both SAXS and WAXS experiments. As a typical example we show an experiment on a colloidal dispersion in a liquid jet at the X-ray Correlation Spectroscopy instrument at the Linac Coherent Light Source free-electron laser.

2.
Opt Express ; 21(21): 24647-64, 2013 Oct 21.
Article in English | MEDLINE | ID: mdl-24150309

ABSTRACT

The single shot based coherence properties of hard x-ray pulses from the Linac Coherent Light Source (LCLS) were measured by analyzing coherent diffraction patterns from nano-particles and gold nanopowder. The intensity histogram of the small angle x-ray scattering ring from nano-particles reveals the fully transversely coherent nature of the LCLS beam with a number of transverse mode 〈Ms〉 = 1.1. On the other hand, the speckle contrasts measured at a large wavevector yields information about the longitudinal coherence of the LCLS radiation after a silicon (111) monochromator. The quantitative agreement between our data and the simulation confirms a mean coherence time of 2.2 fs and a x-ray pulse duration of 29 fs. Finally the observed reduction of the speckle contrast generated by x-rays with pulse duration longer than 30 fs indicates ultrafast dynamics taking place at an atomic length scale prior to the permanent sample damage.

3.
Phys Rev Lett ; 108(2): 024801, 2012 Jan 13.
Article in English | MEDLINE | ID: mdl-22324689

ABSTRACT

We measured the transverse and longitudinal coherence properties of the Linac Coherent Light Source (LCLS) at SLAC in the hard x-ray regime at 9 keV photon energy on a single shot basis. Speckle patterns recorded in the forward direction from colloidal nanoparticles yielded the transverse coherence properties of the focused LCLS beam. Speckle patterns from a gold nanopowder recorded with atomic resolution allowed us to measure the shot-to-shot variations of the spectral properties of the x-ray beam. The focused beam is in the transverse direction fully coherent with a mode number close to 1. The average number of longitudinal modes behind the Si(111) monochromator is about 14.5 and the average coherence time τ(c)=(2.0±1.0) fc. The data suggest a mean x-ray pulse duration of (29±14) fs behind the monochromator for (100±14) fc electron pulses.


Subject(s)
Gold/chemistry , Light , Metal Nanoparticles/chemistry , Models, Theoretical , Nanostructures/chemistry , Photons , Electrons , Particle Accelerators , Scattering, Radiation , X-Rays
4.
Rev Sci Instrum ; 80(11): 113109, 2009 Nov.
Article in English | MEDLINE | ID: mdl-19947719

ABSTRACT

We report on the first experimental determination of the hyperfine structure of the 1s(5)-2p(9) transition in (39)Ar. We give a detailed description of the sample preparation, spectroscopy cell cleaning, and spectroscopic setup. The resulting set of parameters consists of the hyperfine constants of the levels involved and the isotopic shift between (39)Ar and (40)Ar. With the achieved precision all laser frequencies necessary for the implementation of atom trap trace analysis for (39)Ar, i.e., laser cooling and repumping frequencies, are now known.

SELECTION OF CITATIONS
SEARCH DETAIL
...