Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Cardiovasc J S Afr ; 12(3): 152-8, 2001.
Article in English | MEDLINE | ID: mdl-11533737

ABSTRACT

OBJECTIVES: Short-term results of the bioprosthetic Biocor No-React composite porcine stentless aortic valve (Biocor Industria e Pesquisas LTDA, Belo Horizonte, Brazil) implanted in patients in whom anticoagulation was thought to be contraindicated or expected to be non-compliant. METHODS: Retrospective review of 52 consecutive prospective patients in whom this valve was implanted, between September 1994 and May 1998. RESULTS: Average age was 44 +/- 17 years; 75% of patients were operated on for rheumatic heart disease and combined procedures were done in 40% of cases. Early mortality was 5.8%, and related to pre-operative ejection fraction ( P < 0.03), New York Heart Association (NYHA) class (P < 0.01), and bacterial endocarditis (P < 0.04). On discharge, 84% of survivors were in NYHA class I and 16% in class II. The average postoperative prosthetic valve peak gradient on echocardiography was 19.9 +/- 11 mmHg and was related to pre-operative ejection fraction and smaller valve sizes. Postoperative residual trivial or mild aortic regurgitation was seen in 19 patients (36.6%), resolved on follow-up in 10 cases, and did not correlate with structural deterioration, re-operation, mortality, or widening of the non-coronary sinus. The non-coronary aortic sinus was widened on closure, because of perceived crowding of the adjacent stentless valve commisures, in 52% of cases. This was thought to be related to the use of an oblique as opposed to transverse aortotomy. Patient survival, inclusive of operative deaths, was 88.5%, and event-free survival was 80.0% at 4 years. CONCLUSION: The short-term results of this stentless aortic valve in a young predominantly third-world population group are acceptable, and appear to be superior to the results for mechanical valves in a similar patient group. We would recommend a transverse aortotomy above the sinotubular ridge to be the more appropriate aortotomy incision when using stentless aortic valves.


Subject(s)
Aortic Valve/physiopathology , Bioprosthesis , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Adolescent , Adult , Aged , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Rheumatic Heart Disease/surgery , South Africa , Statistics as Topic
2.
Ann Thorac Surg ; 71(3): 1030-2, 2001 Mar.
Article in English | MEDLINE | ID: mdl-11269424

ABSTRACT

A 31-year-old woman who had undergone left pneumonectomy for a tuberculosis-destroyed left lung 3 years previously presented in respiratory distress after a pregnancy complicated by preeclampsia and aspiration pneumonia. Investigation revealed a large aortic arch aneurysm as well as a filling defect in the descending thoracic aortic lumen. Emergency aortic arch reconstruction was performed for a massive pseudoaneurysm or contained rupture filling the entire postpneumonectomy space. Pathologic and microbiological examination demonstrated Aspergillus fumigatus and active inflammation.


Subject(s)
Aneurysm, Infected/etiology , Aortic Diseases/microbiology , Pneumonectomy/adverse effects , Adult , Aorta , Female , Humans
3.
J Heart Valve Dis ; 9(1): 64-73; discussion 73-4, 2000 Jan.
Article in English | MEDLINE | ID: mdl-10678377

ABSTRACT

BACKGROUND AND AIM OF THE STUDY: The management of concomitant moderate or severe ischemic mitral regurgitation in the presence of ischemic heart disease is important for long-term prognosis. Mitral repair by either a suture or ring annuloplasty method has been advocated, although clear superiority of either method has not been established. METHODS: Combined coronary artery bypass and mitral valve surgery for ischemic mitral incompetence was performed on 68 consecutive patients between January 1996 and December 1998. The outcome in 63 of these patients (35 females, 28 males) who underwent mitral valve repair was reviewed. RESULTS: Average patient age was 61+/-9.4 years (range: 39-81 years). Average left ventricular ejection fraction (LVEF) was 42.1%; a suture annuloplasty was used in 84% and a ring in 16%. The average number of distal anastomoses was 3.9+/-1.1 (range: 1-6) and aortic cross-clamp time was 131+/-35 min (range: 58-238 min). Operative mortality rate (<30 days or in-hospital) was 12.7% and only requirement for intra-aortic balloon pumping either before or during surgery (21%) was predictive (p<0.05). On discharge, 98.2% of patients were in NYHA class I or II. Follow up (range: 1-35 months) was complete in 95% of cases. Moderate mitral regurgitation on discharge occurred in nine patients and was not related to the type of annuloplasty. Predictive risk factors were preoperative severe mitral regurgitation (p<0.04), poor LVEF (p = 0.05), and was predictive of deterioration of NYHA class (p<0.02), progression of regurgitation (p<0.05), and poor outcome (p<0.01). Poor outcome was also related to surgeon's experience. Structural valvular deterioration occurred in 21.8% of operative survivors, and there was one reoperation and four late deaths. The survival rate (including operative deaths) at 35 months was 68.3 +/- 13.1%, and event-free survival rate (no mortality, reoperation or angina) 65.2+/-6.2%. CONCLUSIONS: The type of annuloplasty used did not influence outcome. The risk of structural mitral valve dysfunction on follow up was related to severe preoperative mitral regurgitation, poor LVEF, surgeon's experience, and was predictive of poor outcome.


Subject(s)
Coronary Disease/complications , Coronary Disease/surgery , Mitral Valve Insufficiency/complications , Mitral Valve Insufficiency/surgery , Mitral Valve/surgery , Adult , Aged , Coronary Artery Bypass , Female , Humans , Intra-Aortic Balloon Pumping , Male , Middle Aged , Retrospective Studies , Suture Techniques , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...