1.
Vet Radiol Ultrasound ; 63(4): 469-477, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35188701

ABSTRACT

A positron emission tomography (PET) scanner, with an openable ring of detectors, was specifically designed to image the distal limb of standing horses. The goals of this prospective, preclinical, experimental, methods comparison study were to validate the safety of the scanner, assess image quality, and optimize scanning protocols. Six research horses were imaged three times (twice standing, once anesthetized) and six horses in active race training were imaged once under standing sedation. Multiple scans of both front fetlocks were obtained with different scan durations and axial fields of view. A total of 94 fetlock scans were attempted and 90 provided images of diagnostic value. Radiotracer uptake was the main factor affecting image quality, while motion did not represent a major issue. Scan duration and field of view also affected image quality. Eight specific lesions were identified on PET images from anesthetized horses and were all also independently recognized on the PET images obtained on standing horses. Maximal standardized uptake values (SUVmax) had good repeatability for the assessment of specific lesions among different scans. Three feet and six carpi were also successfully imaged. This study validated the safety and practicality of a PET scanner specifically designed to image the distal limb in standing horses. Proper preparation of horses, similar to bone scintigraphy, is important for image quality. A 4-min scan with 12 cm field of view was considered optimal for clinical fetlock imaging. Evaluation of a larger clinical population is the next step for further assessment of the clinical utility of PET imaging in horses.


Subject(s)
Joints , Positron-Emission Tomography , Animals , Horses , Positron-Emission Tomography/methods , Positron-Emission Tomography/veterinary , Prospective Studies , Radionuclide Imaging
2.
Int J Part Ther ; 7(4): 11-18, 2021.
Article in English | MEDLINE | ID: mdl-33829069

ABSTRACT

PURPOSE: Proton therapy precisely delivers radiation to cancers to cause damaging strand breaks to cellular DNA, kill malignant cells, and stop tumor growth. Therapeutic protons also generate short-lived activated nuclei of carbon, oxygen, and nitrogen atoms in patients as a result of atomic transmutations that are imaged by positron emission tomography (PET). We hypothesized that the transition of 18O to 18F in an 18O-substituted nucleoside irradiated with therapeutic protons may result in the potential for combined diagnosis and treatment for cancer with proton therapy. MATERIALS AND METHODS: Reported here is a feasibility study with a therapeutic proton beam used to irradiate H2 18O to a dose of 10 Gy produced by an 85 MeV pristine Bragg peak. PET imaging initiated >45 minutes later showed an 18F decay signal with T1/2 of ∼111 minutes. RESULTS: The 18O to 18F transmutation effect on cell survival was tested by exposing SQ20B squamous carcinoma cells to physiologic 18O-thymidine concentrations of 5 µM for 48 hours followed by 1- to 9-Gy graded doses of proton radiation given 24 hours later. Survival analyses show radiation sensitization with a dose modification factor (DMF) of 1.2. CONCLUSIONS: These data support the idea of therapeutic transmutation in vitro as a biochemical consequence of proton activation of 18O to 18F in substituted thymidine enabling proton radiation enhancement in a cancer cell. 18O-substituted molecules that incorporate into cancer targets may hold promise for improving the therapeutic window of protons and can be evaluated further for postproton therapy PET imaging.

3.
Micromachines (Basel) ; 10(4)2019 Mar 31.
Article in English | MEDLINE | ID: mdl-30935105

ABSTRACT

Soft, untethered microrobots composed of biocompatible materials for completing micromanipulation and drug delivery tasks in lab-on-a-chip and medical scenarios are currently being developed. Alginate holds significant potential in medical microrobotics due to its biocompatibility, biodegradability, and drug encapsulation capabilities. Here, we describe the synthesis of MANiACs-Magnetically Aligned Nanorods in Alginate Capsules-for use as untethered microrobotic surface tumblers, demonstrating magnetically guided lateral tumbling via rotating magnetic fields. MANiAC translation is demonstrated on tissue surfaces as well as inclined slopes. These alginate microrobots are capable of manipulating objects over millimeter-scale distances. Finally, we demonstrate payload release capabilities of MANiACs during translational tumbling motion.

4.
Vet Radiol Ultrasound ; 57(6): 630-638, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27699910

ABSTRACT

Positron emission tomography (PET) is a highly sensitive, noninvasive imaging technique for quantifying biological functions of tissues. However, at the time of this study, PET imaging applications had not been reported in the horse. The aim of this exploratory study was to determine whether a portable high-resolution PET scanner could be used to image the equine distal limb. Images of the front feet and fetlocks of three research horses, with known lesions localized to the distal front limbs, were acquired under general anesthesia after administration of 18 F-fluorodeoxyglucose (18 F-FDG), with doses ranging from 1.5 to 2.9 MBq/kg. The radiation exposure measured during imaging was slightly higher than 99m Technetium scintigraphy. However, the use of general anesthesia allowed the proximity and the contact time with the patient to be minimized for the staff involved. 18 F-FDG uptake was evident throughout the soft tissues, with the highest uptake in the coronary band and the lowest uptake in the tendons. Anatomic structures could be discriminated due to the high contrast between soft tissue and bone. Detected lesions included lysis of the flexor cortex of the navicular bone, lesions of flexor tendons and suspensory ligament, and abnormal uptake through the lamina of a laminitic subject. Findings indicated that tomographic molecular imaging is feasible in the equine distal limb and could be useful as a future diagnostic technique for clinical and research studies, especially those involving tendinopathy/desmopathy and laminitis.


Subject(s)
Fluorodeoxyglucose F18/metabolism , Hindlimb/diagnostic imaging , Positron-Emission Tomography/veterinary , Radiopharmaceuticals/metabolism , Animals , Dose-Response Relationship, Drug , Female , Horses , Positron-Emission Tomography/methods
5.
J Magn Magn Mater ; 380: 295-298, 2015 Apr 15.
Article in English | MEDLINE | ID: mdl-25678734

ABSTRACT

Applying magnetic fields to guide and retain drug-loaded magnetic particles in vivo has been proposed as a way of treating illnesses. Largely, these efforts have been targeted at tumors. One significant barrier to long range transport within tumors is the extracellular matrix (ECM). We perform single particle measurements of 18 nm diameter nanorods undergoing magnetophoresis through ECM, and analyze the motion of these nanorods in two dimensions. We observe intra-particle magnetophoresis in this viscoelastic environment and measure the fraction of time these nanorods spend effectively hindered, versus effectively translating.

6.
Article in English | MEDLINE | ID: mdl-25377422

ABSTRACT

The principle of magnetic drug targeting, wherein therapy is attached to magnetically responsive carriers and magnetic fields are used to direct that therapy to disease locations, has been around for nearly two decades. Yet our ability to safely and effectively direct therapy to where it needs to go, for instance to deep tissue targets, remains limited. To date, magnetic targeting methods have not yet passed regulatory approval or reached clinical use. Below we outline key challenges to magnetic targeting, which include designing and selecting magnetic carriers for specific clinical indications, safely and effectively reaching targets behind tissue and anatomical barriers, real-time carrier imaging, and magnet design and control for deep and precise targeting. Addressing these challenges will require interactions across disciplines. Nanofabricators and chemists should work with biologists, mathematicians, and engineers to better understand how carriers move through live tissues and how to optimize carrier and magnet designs to better direct therapy to disease targets. Clinicians should be involved early on and throughout the whole process to ensure the methods that are being developed meet a compelling clinical need and will be practical in a clinical setting. Our hope is that highlighting these challenges will help researchers translate magnetic drug targeting from a novel concept to a clinically available treatment that can put therapy where it needs to go in human patients.


Subject(s)
Delayed-Action Preparations/chemistry , Magnetic Fields , Magnetite Nanoparticles/chemistry , Molecular Targeted Therapy/methods , Nanocapsules/chemistry , Delayed-Action Preparations/radiation effects , Magnetite Nanoparticles/radiation effects , Nanocapsules/administration & dosage , Nanocapsules/radiation effects
7.
Med Phys ; 39(5): 2578-83, 2012 May.
Article in English | MEDLINE | ID: mdl-22559628

ABSTRACT

PURPOSE: A time-varying magnetic field can cause unpleasant peripheral nerve stimulation (PNS) when the maximum excursion of the magnetic field (ΔB) is above a frequency-dependent threshold level [P. Mansfield and P. R. Harvey, Magn. Reson. Med. 29, 746-758 (1993)]. Clinical and research magnetic resonance imaging (MRI) gradient systems have been designed to avoid such bioeffects by adhering to regulations and guidelines established on the basis of clinical trials. Those trials, generally employing sinusoidal waveforms, tested human responses to magnetic fields at frequencies between 0.5 and 10 kHz [W. Irnich and F. Schmitt, Magn. Reson. Med. 33, 619-623 (1995), T. F. Budinger et al., J. Comput. Assist. Tomogr. 15, 909-914 (1991), and D. J. Schaefer et al., J. Magn. Reson. Imaging 12, 20-29 (2000)]. PNS thresholds for frequencies higher than 10 kHz had been extrapolated, using physiological models [J. P. Reilly et al., IEEE Trans. Biomed. Eng. BME-32(12), 1001-1011 (1985)]. The present study provides experimental data on human PNS thresholds to oscillating magnetic field stimulation from 2 to 183 kHz. Sinusoidal waveforms were employed for several reasons: (1) to facilitate comparison with earlier reports that used sine waves, (2) because prior designers of fast gradient hardware for generalized waveforms (e.g., including trapezoidal pulses) have employed quarter-sine-wave resonant circuits to reduce the rise- and fall-times of pulse waveforms, and (3) because sinusoids are often used in fast pulse sequences (e.g., spiral scans) [S. Nowak, U.S. patent 5,245,287 (14 September 1993) and K. F. King and D. J. Schaefer, J. Magn. Reson. Imaging 12, 164-170 (2000)]. METHODS: An IRB-approved prospective clinical trial was performed, involving 26 adults, in which one wrist was exposed to decaying sinusoidal magnetic field pulses at frequencies from 2 to 183 kHz and amplitudes up to 0.4 T. Sham exposures (i.e., with no magnetic fields) were applied to all subjects. RESULTS: For 0.4 T pulses at 2, 25, 59, 101, and 183 kHz, stimulation was reported by 22 (84.6%), 24 (92.3%), 15 (57.7%), 2 (7.7%), and 1 (3.8%) subjects, respectively. CONCLUSIONS: The probability of PNS due to brief biphasic time-varying sinusoidal magnetic fields with magnetic excursions up to 0.4 T is shown to decrease significantly at and above 101 kHz. This phenomenon may have particular uses in dynamic scenarios (e.g., cardiac imaging) and in studying processes with short decay times (e.g., electron paramagnetic resonance imaging, bone and solids imaging). The study suggests the possibility of new designs for human and preclinical MRI systems that may be useful in clinical practice and scientific research.


Subject(s)
Magnetic Fields/adverse effects , Peripheral Nerves/physiology , Adult , Humans , Probability , Sensation/physiology , Sensory Thresholds
8.
Technol Cancer Res Treat ; 4(1): 55-60, 2005 Feb.
Article in English | MEDLINE | ID: mdl-15649088

ABSTRACT

Positron emission mammography (PEM) provides images of biochemical activity in the breast with spatial resolution matching individual ducts (1.5 mm full-width at half-maximum). This spatial resolution, supported by count efficiency that results in high signal-to-noise ratio, allows confident visualization of intraductal as well as invasive breast cancers. Clinical trials with a full-breast PEM device have shown high clinical accuracy in characterizing lesions identified as suspicious on the basis of conventional imaging or physical examination (sensitivity 93%, specificity 83%, area under the ROC curve of 0.93), with high sensitivity preserved (91%) for intraductal cancers. Increased sensitivity did not come at a cost of reduced specificity. Considering that intraductal cancer represents more than 30% of reported cancers, and is the form of cancer with the highest probability of achieving surgical cure, it is likely that the use of PEM will complement anatomic imaging modalities in the areas of surgical planning, high-risk monitoring, and minimally invasive therapy. The quantitative nature of PET promises to assist researchers interested studying the response of putative cancer precursors (e.g., atypical ductal hyperplasia) to candidate prevention agents.


Subject(s)
Breast Neoplasms/diagnosis , Mammography/instrumentation , Mammography/methods , Positron-Emission Tomography/instrumentation , Positron-Emission Tomography/methods , Breast Neoplasms/diagnostic imaging , Humans
9.
Ann Surg Oncol ; 10(1): 86-91, 2003.
Article in English | MEDLINE | ID: mdl-12513966

ABSTRACT

BACKGROUND: Evaluation of high-risk mammograms represents an enormous clinical challenge. Functional breast imaging coupled with mammography (positron emission mammography [PEM]) could improve imaging of such lesions. A prospective study was performed using PEM in women scheduled for stereotactic breast biopsy. METHODS: Patients were recruited from the surgical clinic. Patients were injected with 10 mCi of 2-[18F] fluorodeoxyglucose. One hour later, patients were positioned on the stereotactic biopsy table, imaged with a PEM scanner, and a stereotactic biopsy was performed. Imaging was reviewed and compared with pathologic results. RESULTS: There were 18 lesions in 16 patients. PEM images were analyzed by drawing a region of interest at the biopsy site and comparing the count density in the region of interest with the background. A lesion-to-background ratio >2.5 appeared to be a robust indicator of malignancy and yielded a sensitivity of 86%, specificity of 91%, and overall diagnostic accuracy of 89%. No adverse events were associated with the PEM imaging. CONCLUSIONS: The data show that PEM is safe, feasible, and has an encouraging accuracy rate in this initial experience. Lesion-to-background ratios >2.5 were found to be a useful threshold value for identifying positive (malignant) results. This study supports the further development of PEM.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Mammography/methods , Tomography, Emission-Computed , Adult , Aged , Aged, 80 and over , Biopsy, Needle/methods , Female , Humans , Image Processing, Computer-Assisted , Middle Aged , Pilot Projects , Prospective Studies