Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Nucl Med Commun ; 29(7): 599-606, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18528181

ABSTRACT

OBJECTIVE: The correct staging of patients with malignant liver tumors before radio-frequency ablation (RFA) is mandatory for successful treatment. Our study aimed to compare the influence on decision to perform RFA of whole-body fluorodeoxyglucose (FDG)-PET/computed tomography (CT) with whole-body contrast-enhanced CT (CE-CT) and PET alone. METHODS: Fifty-eight patients with known hepatic malignancies (23, liver metastases 35) received FDG-PET/CT before RFA planned with curative intention. CT and PET data were each read separately, PET/CT fusion data were read in consensus afterward by a third reader group. The diagnostic accuracy of CE-CT, PET alone, and PET/CT to identify patients eligible for RFA was compared and the impact on decision was analyzed. The McNemar test with Bonferroni correction was used to test for significant differences. RESULTS: The accuracy and sensitivity to detect correctly intrahepatic and extrahepatic tumor were 94 and 97% for CT, 75 and 54% for PET, and 97 and 95% for PET/CT. The differences between CT and PET, as well as between PET/CT and PET, were statistically significant, but there was no significant difference between PET/CT and CT alone (P>0.65). PET alone, CE-CT, and PET/CT correctly identified 32, 55, and 57 patients, respectively. Again, PET/CT showed no significant advantage over CE-CT. Both imaging methods performed significantly better than PET alone (P<0.0001). Forty-three (74%) of 58 patients underwent RFA with curative intention. CONCLUSION: Whole-body imaging changed patient management in 26% of the patients planned for curative intended RFA, yet there was no significant difference between CE-CT and PET/CT.


Subject(s)
Catheter Ablation/methods , Fluorodeoxyglucose F18 , Liver Neoplasms/diagnosis , Liver Neoplasms/surgery , Positron-Emission Tomography/methods , Preoperative Care/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Female , Humans , Male , Middle Aged , Patient Selection , Radiopharmaceuticals , Subtraction Technique , Treatment Outcome
2.
Eur J Radiol ; 67(2): 362-371, 2008 Aug.
Article in English | MEDLINE | ID: mdl-18155866

ABSTRACT

PURPOSE: Morphologic imaging after radiofrequency ablation (RFA) of liver metastases is hampered by rim-like enhancement in the ablation margin, making the identification of local tumor progression (LTP) difficult. Follow-up with PET/CT is compared to follow-up with PET alone and MRI after RFA. METHODS AND MATERIALS: Sixteen patients showed 25 FDG-positive colorectal liver metastases in pre-interventional PET/CT. Post-interventional PET/CT was performed 24h after ablation and was repeated after 1, 3 and 6 months and then every 6 months. PET and PET/CT data were compared with MR data sets acquired within 14 days before or after these time points. Either histological proof by biopsy or resection, or a combination of contrast-enhanced CT at fixed time points and clinical data served as a reference. RESULTS: The 25 metastases showed a mean size of 20mm and were treated with 39 RFA sessions. Ten lesions which developed LTP received a second round of RFA; four lesions received three rounds of treatment. The mean follow-up time was 22 months. Seventy-two PET/CT and 57 MR examinations were performed for follow-up. The accuracy and sensitivity for tumor detection was 86% and 76% for PET alone, 91% and 83% for PET/CT and 92% and 75% for MRI, respectively. CONCLUSIONS: In comparison to PET alone, PET/CT was significantly better for detecting LTP after RFA. There were no significant differences between MRI and PET/CT. These preliminary results, however, need further verification.


Subject(s)
Catheter Ablation/methods , Colorectal Neoplasms/pathology , Liver Neoplasms/diagnosis , Liver Neoplasms/surgery , Adult , Aged , Contrast Media , Female , Fluorodeoxyglucose F18 , Humans , Image Processing, Computer-Assisted , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/secondary , Magnetic Resonance Imaging/methods , Male , Middle Aged , Positron-Emission Tomography/methods , Radiopharmaceuticals , Tomography, X-Ray Computed/methods , Treatment Outcome
3.
JAMA ; 296(21): 2590-600, 2006 Dec 06.
Article in English | MEDLINE | ID: mdl-17148724

ABSTRACT

CONTEXT: Staging of patients with colorectal cancer often requires a multimodality, multistep imaging approach. Colonography composed of a combined modality of positron emission tomography (PET) and computed tomography (CT) provides whole-body tumor staging in a single session. OBJECTIVES: To determine the staging accuracy of whole-body PET/CT colonography compared with the staging accuracies of CT followed by PET (CT + PET) and CT alone and to evaluate the effect of PET/CT colonography on therapy planning compared with conventional staging (CT of the abdomen and thorax and optical colonoscopy). DESIGN, SETTING, AND PATIENTS: Prospective study of 47 patients enrolled between May 2004 and June 2006 with clinical findings and optical colonoscopy that suggested primary colorectal cancer (mean [SD] age, 71 [11] years; range, 47-92 years). Patients underwent whole-body PET/CT colonography 1 day after colonoscopy. The study was conducted at a university hospital with a mean (SD) follow-up of 447 (140) days (range, 232-653 days). MAIN OUTCOME MEASURES: Correct classification of overall TNM stage using PET/CT colonography compared with CT + PET and CT alone. Secondary outcome measures were the accurate assessment of T-stage, N-stage, and M-stage by PET/CT colonography compared with CT + PET and CT alone and the effect of PET/CT colonography on therapy planning. RESULTS: Of the 47 patients with a total of 50 lesions, the overall TNM stage was correctly determined for 37 lesions with PET/CT colonography (74%; 95% confidence interval [CI], 60%-85%), 32 lesions with CT + PET (64%; 95% CI, 49%-77%), and 26 lesions with CT alone with a 0.7-cm node threshold (52%; 95% CI, 37%-66%). Compared with optimized abdominal CT staging alone, PET/CT colonography was significantly more accurate in defining TNM stage (difference, 22%; 95% CI, 9%-36%; P=.003), which was mainly based on a more accurate definition of the T-stage. Differences were not detected for defining N-stage between PET/CT colonography and CT alone with a threshold of 0.7 cm for malignant nodes but were detected with a threshold of 1 cm. Differences were not detected in defining M-stage separately or when comparing the accuracies of PET/CT colonography with CT + PET. PET/CT colonography affected consecutive therapy decisions in 4 patients (9%; 95% CI, 2.4%-20.4%) compared with conventional staging (CT alone and colonoscopy). CONCLUSIONS: In this preliminary study, PET/CT colonography is at least equivalent to CT + PET for tumor staging in patients with colorectal cancer. Thus, PET/CT colonography in conjunction with optical colonoscopy may be a suitable concept of tumor staging for patients with colorectal cancer.


Subject(s)
Colonography, Computed Tomographic , Colorectal Neoplasms/diagnosis , Neoplasm Staging/methods , Positron-Emission Tomography , Aged , Aged, 80 and over , Colorectal Neoplasms/therapy , Female , Humans , Male , Middle Aged , Prospective Studies
4.
Eur J Radiol ; 58(3): 383-9, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16476533

ABSTRACT

Lymph node staging according to the TNM criteria is an essential part of tumor evaluation. Several morphological and functional imaging procedures are used complementarily in this setting. Dual-modality PET/CT scanners are able to provide anatomical and functional data sets in a single session with accurate image co-registration. Comparative studies between morphological imaging procedures, such as MRI and CT, with co-registered PET/CT demonstrated significantly better lymph node staging with PET/CT than with anatomical procedures alone, regardless of the staged body compartment (head and neck, thorax or abdominal area). Based on more accurate staging results, PET/CT was able to alter the patients' therapy in a significant number of studies. Functional imaging with FDG-PET ([(18)F]-2-fluoro-2-desoxy-D-glucose-positron emission tomography) demonstrated outstanding results in lymph node staging of different tumor diseases. By adding anatomical information to PET, PET/CT outperforms PET alone when assessing the TNM-stage of different malignant diseases. This paper provides an overview concerning the performance of PET/CT in staging lymph nodes for malignant spread and points out benefits and limitations of this new imaging modality.


Subject(s)
Lymph Nodes/diagnostic imaging , Medical Oncology/standards , Positron-Emission Tomography/methods , Tomography, X-Ray Computed/methods , Contrast Media , Fluorodeoxyglucose F18 , Humans , Image Enhancement/methods , Lymph Nodes/pathology , Lymphatic Metastasis/diagnosis , Lymphatic Metastasis/pathology , Neoplasm Staging , Reproducibility of Results
5.
Eur Radiol ; 16(1): 80-7, 2006 Jan.
Article in English | MEDLINE | ID: mdl-15868122

ABSTRACT

The aim of this study was to determine the accuracy of dual-modality positron emission tomography(PET)/computed tomography (CT) in the detection of residual tumor after radiofrequency ablation (RFA) of liver metastasis of colorectal cancer. Eleven patients with 16 hepatic metastases (mean size 2.9 cm) from colorectal cancer were enrolled in this study, and 19 RFA procedures and 32 PET/CT examinations were performed. The patients had PET/CT before and after RFA using [18F]-2-fluoro-2-deoxy-D: -glucose. CT images alone were read by two radiologists, PET images alone were evaluated by two nuclear physicians. Fused images were read by one physician of each speciality in consensus. The accuracy for detection of residual tumor by the different imaging modalities following RFA was assessed. Eleven patients with a mean age of 63 (range 55-71) years were evaluated. The mean follow-up period was 393 days. The overall procedure-based sensitivity for detection of residual tumor was 65% for PET and PET/CT and 44% for CT alone. The accuracies were 68% and 47%, respectively. Four patients had residual tumor after RFA, six patients total developed local recurrence. PET/CT therefore possibly proved superior to CT alone when assessing the liver for residual tumor after RFA.


Subject(s)
Catheter Ablation/methods , Colorectal Neoplasms/pathology , Liver Neoplasms/radiotherapy , Liver/diagnostic imaging , Neoplasm Recurrence, Local/diagnosis , Positron-Emission Tomography/methods , Aged , Contrast Media/administration & dosage , Female , Fluorodeoxyglucose F18 , Follow-Up Studies , Humans , Iohexol/analogs & derivatives , Liver Neoplasms/secondary , Male , Middle Aged , Neoplasm, Residual/diagnosis , Observer Variation , Radiopharmaceuticals , Reproducibility of Results , Sensitivity and Specificity , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...