Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Biol ; 19(1): 258, 2021 12 04.
Article in English | MEDLINE | ID: mdl-34863173

ABSTRACT

BACKGROUND: Yeasts of the CTG-clade lineage, which includes the human-infecting Candida albicans, Candida parapsilosis and Candida tropicalis species, are characterized by an altered genetic code. Instead of translating CUG codons as leucine, as happens in most eukaryotes, these yeasts, whose ancestors are thought to have lost the relevant leucine-tRNA gene, translate CUG codons as serine using a serine-tRNA with a mutated anticodon, [Formula: see text]. Previously reported experiments have suggested that 3-5% of the CTG-clade CUG codons are mistranslated as leucine due to mischarging of the [Formula: see text]. The mistranslation was suggested to result in variable surface proteins explaining fast host adaptation and pathogenicity. RESULTS: In this study, we reassess this potential mistranslation by high-resolution mass spectrometry-based proteogenomics of multiple CTG-clade yeasts, including various C. albicans strains, isolated from colonized and from infected human body sites, and C. albicans grown in yeast and hyphal forms. Our data do not support a bias towards CUG codon mistranslation as leucine. Instead, our data suggest that (i) CUG codons are mistranslated at a frequency corresponding to the normal extent of ribosomal mistranslation with no preference for specific amino acids, (ii) CUG codons are as unambiguous (or ambiguous) as the related CUU leucine and UCC serine codons, (iii) tRNA anticodon loop variation across the CTG-clade yeasts does not result in any difference of the mistranslation level, and (iv) CUG codon unambiguity is independent of C. albicans' strain pathogenicity or growth form. CONCLUSIONS: Our findings imply that C. albicans does not decode CUG ambiguously. This suggests that the proposed misleucylation of the [Formula: see text] might be as prevalent as every other misacylation or mistranslation event and, if at all, be just one of many reasons causing phenotypic diversity.


Subject(s)
Candida albicans , Genetic Code , Proteogenomics , Base Sequence , Candida albicans/genetics , Candida albicans/metabolism , Codon/genetics
2.
PLoS One ; 15(12): e0243790, 2020.
Article in English | MEDLINE | ID: mdl-33306699

ABSTRACT

Pathogen identification is a critical step during diagnosis of infectious diseases. Matrix-Assisted Laser Desorption/Ionization Time-Of-Flight mass spectrometry (MALDI-TOF-MS) has become the gold standard for identification of microorganisms cultured on solid media in microbiology laboratories. Direct identification of microbes from liquid specimen, circumventing the need for the additional overnight cultivation step, has been successfully established for blood culture, urine and liquor. Here, we evaluate the ability of MALDI-TOF MS for direct identification of pathogens in synovial fluid after liquid enrichment in BacT/Alert blood culture bottles. Influence of synovial specimen quality on direct species identification with the MALDI BioTyper/Sepsityper was tested with samples inoculated from pretested native synovia with concomitant inoculation of blood or pus, or highly viscous fluid. Here, we achieved >90% concordance with culture on solid medium, and only mixed-species samples posed significant problems. Performance in routine diagnostics was tested prospectively on bottles inoculated by treating physicians on ward. There, we achieved >70% concordance with culture on solid media. The major contributors to test failure were the absence of a measurable mass signal and mixed-specimen samples. The Sepsityper workflow worked well on samples derived from BacT/Alert blood culture bottles inoculated with synovial fluid, giving concordant results to identification from solid media. Host remnant material in the inoculum, such as blood or pus, had no detrimental effect on identification score values of the BioTyper system after processing with the Sepsityper workflow, and neither had the initial viscosity of the synovial sample.


Subject(s)
Blood Culture , Infections/blood , Infections/diagnosis , Joint Diseases/blood , Joint Diseases/microbiology , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Humans , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...