Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr A ; 1549: 14-24, 2018 May 11.
Article in English | MEDLINE | ID: mdl-29588097

ABSTRACT

This study presents the development and validation of a quantitation method for the analysis of multi-class, multi-residue veterinary drugs using lipid removal cleanup cartridges, enhanced matrix removal lipid (EMR-Lipid), for different meat matrices by liquid chromatography tandem mass spectrometry detection. Meat samples were extracted using a two-step solid-liquid extraction followed by pass-through sample cleanup. The method was optimized based on the buffer and solvent composition, solvent additive additions, and EMR-Lipid cartridge cleanup. The developed method was then validated in five meat matrices, porcine muscle, bovine muscle, bovine liver, bovine kidney and chicken liver to evaluate the method performance characteristics, such as absolute recoveries and precision at three spiking levels, calibration curve linearity, limit of quantitation (LOQ) and matrix effect. The results showed that >90% of veterinary drug analytes achieved satisfactory recovery results of 60-120%. Over 97% analytes achieved excellent reproducibility results (relative standard deviation (RSD) < 20%), and the LOQs were 1-5 µg/kg in the evaluated meat matrices. The matrix co-extractive removal efficiency by weight provided by EMR-lipid cartridge cleanup was 42-58% in samples. The post column infusion study showed that the matrix ion suppression was reduced for samples with the EMR-Lipid cartridge cleanup. The reduced matrix ion suppression effect was also confirmed with <15% frequency of compounds with significant quantitative ion suppression (>30%) for all tested veterinary drugs in all of meat matrices. The results showed that the two-step solid-liquid extraction provides efficient extraction for the entire spectrum of veterinary drugs, including the difficult classes such as tetracyclines, beta-lactams etc. EMR-Lipid cartridges after extraction provided efficient sample cleanup with easy streamlined protocol and minimal impacts on analytes recovery, improving method reliability and consistency.


Subject(s)
Chromatography, Liquid/methods , Drug Residues/analysis , Lipids/analysis , Meat/analysis , Tandem Mass Spectrometry/methods , Veterinary Drugs/analysis , Veterinary Drugs/classification , Animals , Cattle , Chickens , Dimethyl Sulfoxide/chemistry , Muscles/metabolism , Reference Standards , Reproducibility of Results , Solvents/chemistry , Sus scrofa
2.
J Agric Food Chem ; 65(34): 7251, 2017 Aug 30.
Article in English | MEDLINE | ID: mdl-28727433
3.
Anal Bioanal Chem ; 409(10): 2639-2653, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28224246

ABSTRACT

Veterinary drug residues in animal-derived foods must be monitored to ensure food safety, verify proper veterinary practices, enforce legal limits in domestic and imported foods, and for other purposes. A common goal in drug residue analysis in foods is to achieve acceptable monitoring results for as many analytes as possible, with higher priority given to the drugs of most concern, in an efficient and robust manner. The U.S. Department of Agriculture has implemented a multiclass, multi-residue method based on sample preparation using dispersive solid phase extraction (d-SPE) for cleanup and ultrahigh-performance liquid chromatography-tandem quadrupole mass spectrometry (UHPLC-QQQ) for analysis of >120 drugs at regulatory levels of concern in animal tissues. Recently, a new cleanup product called "enhanced matrix removal for lipids" (EMR-L) was commercially introduced that used a unique chemical mechanism to remove lipids from extracts. Furthermore, high-resolution quadrupole-time-of-flight (Q/TOF) for (U)HPLC detection often yields higher selectivity than targeted QQQ analyzers while allowing retroactive processing of samples for other contaminants. In this study, the use of both d-SPE and EMR-L sample preparation and UHPLC-QQQ and UHPLC-Q/TOF analysis methods for shared spiked samples of bovine muscle, kidney, and liver was compared. The results showed that the EMR-L method provided cleaner extracts overall and improved results for several anthelmintics and tranquilizers compared to the d-SPE method, but the EMR-L method gave lower recoveries for certain ß-lactam antibiotics. QQQ vs. Q/TOF detection showed similar mixed performance advantages depending on analytes and matrix interferences, with an advantage to Q/TOF for greater possible analytical scope and non-targeted data collection. Either combination of approaches may be used to meet monitoring purposes, with an edge in efficiency to d-SPE, but greater instrument robustness and less matrix effects when analyzing EMR-L extracts. Graphical abstract Comparison of cleanup methods in the analysis of veterinary drug residues in bovine tissues.


Subject(s)
Chromatography, High Pressure Liquid/methods , Drug Residues/analysis , Lipids/analysis , Tandem Mass Spectrometry/methods , Veterinary Drugs/analysis , Animals , Cattle , Drug Residues/chemistry , Drug Residues/isolation & purification , Kidney/metabolism , Lipids/chemistry , Lipids/isolation & purification , Liver/metabolism , Muscle, Skeletal/metabolism , Solid Phase Extraction , Tissue Distribution , Veterinary Drugs/chemistry , Veterinary Drugs/isolation & purification
4.
J Agric Food Chem ; 60(40): 9991-9, 2012 Oct 10.
Article in English | MEDLINE | ID: mdl-22931171

ABSTRACT

An automated dispersive solid phase extraction (dSPE) cleanup procedure as part of the Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) method, coupled with liquid chromatography-tandem mass spectrometry using electrospray ionization in positive mode, was used for the simultaneous analysis of 236 pesticides in three dried powdered botanical dietary supplements (ginseng, saw palmetto, and gingko biloba). The procedure involved extraction of the dried powdered botanical samples with salt-out acetonitrile/water extraction using anhydrous magnesium sulfate and sodium chloride, followed by an automated dSPE cleanup using a mixture of octadodecyl- (C18) and primary-secondary amine (PSA)-linked silica sorbents and anhydrous MgSO4 and online LC-MS/MS analysis. Dynamic multiple-reaction monitoring (DMRM) based on the collection of two precursor-to-product ion transitions with their retention time windows was used for all of the targeted pesticides and the internal standard. Matrix-matched calibration standards were used for quantitation, and standard calibration curves showed linearity (r(2) > 0.99) across a concentration range of 0.2-400 ng/mL for the majority of the 236 pesticides evaluated in the three botanical matrices. Mean recoveries (average %RSD, n = 4) were 91 (6), 93 (4), 96 (3), and 99 (3)% for ginseng, 101 (9), 98 (6), 99 (4), and 102 (3)% for gingko biloba, and 100 (9), 98 (6), 96 (4), and 96 (3)% for saw palmetto at fortification concentrations of 25, 100, 250, and 500 µg/kg, respectively. The geometric mean matrix-dependent instrument detection limits were 0.17, 0.09, and 0.14 µg/kg on the basis of the studies of 236 pesticides tested in ginseng roots, gingko biloba leaves, and saw palmetto berries, respectively. The method was used to analyze incurred ginseng samples that contained thermally labile pesticides with a concentration range of 2-200 µg/kg, indicating different classes of pesticides are being applied to these botanicals other than the traditional pesticides that are commonly used and analyzed by gas chromatography techniques. The method demonstrates the use of an automated cleanup procedure and the LC-MS/MS detection of multiple pesticide residues in dried, powdered botanical dietary supplements.


Subject(s)
Chromatography, High Pressure Liquid/methods , Dietary Supplements/analysis , Pesticide Residues/analysis , Plant Preparations/chemistry , Solid Phase Extraction/methods , Tandem Mass Spectrometry/methods , Ginkgo biloba/chemistry , Panax/chemistry , Plant Extracts/chemistry , Serenoa
5.
J Chromatogr A ; 1227: 138-44, 2012 Mar 02.
Article in English | MEDLINE | ID: mdl-22265780

ABSTRACT

In response to Gulf of Mexico deepwater horizon oil spill, we have developed an atmospheric pressure photoionization (APPI) based ultra high performance liquid chromatography-mass spectrometry (UHPLC-MS) method for high-sensitivity analysis of United States Environmental Protection Agency (US EPA) 16 priority pollutant polynuclear aromatic hydrocarbons (PAHs) in oysters. Analyses were performed on an Agilent's Infinity 1290 UHPLC system coupled with a G6140A single quadrupole MS detector with Syagen's PhotoMate® APPI® source. Column separation was achieved using Zorbax Eclipse PAH column. Chlorobenzene was used as an APPI dopant for maximum overall sensitivity. Dynamic linear ranges were evaluated and found to cover 3.6-5.1 (Ave. 4.4) orders of magnitude with R² of at least 0.995. A quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction and cleanup procedure was used. The spike recoveries ranged from 77% to 110% with %RSD of 0.6-6.7 at spike concentrations below or substantially below the US Food and Drug Administration (FDA) level of concern in oysters. The on-column instrument detection limits (IDLs, 6σ S/N=3) ranged from 8 to 106 pg with an average of 23 pg for 16 PAHs. The method detection limits (MDLs, 6σ S/N=3) ranged from 0.013 to 0.129 ppm with an average of 0.040 ppm for all analytes. These MDLs were about 5 times to over 4 orders of magnitude lower than US FDA levels of concern in oysters.


Subject(s)
Chromatography, High Pressure Liquid/methods , Environmental Pollutants/analysis , Mass Spectrometry/methods , Ostreidae/chemistry , Polycyclic Aromatic Hydrocarbons/analysis , Shellfish/analysis , Air Ionization , Animals , Atmospheric Pressure , Limit of Detection , Reproducibility of Results , Sensitivity and Specificity , United States , United States Environmental Protection Agency
6.
J Chromatogr A ; 1178(1-2): 56-9, 2008 Jan 18.
Article in English | MEDLINE | ID: mdl-18078947

ABSTRACT

Processing gram to kilogram quantities of target analytes has led to the exploration of several high-throughput separation techniques. Among those investigated is steady state recycling (SSR). Similar to simulated moving bed (SMB) fractions are collected from the leading and trailing edges of a chromatographic profile while sample material is injected into the interior. Purifying large amounts of sample in the semi-preparative stage is ideal for these groups. SSR allows for development of methods capable of separating 50 g to kilograms and even greater amounts of product efficiently. Using polarimetry to optimize the SSR method further improves the efficiency of method development, providing comprehensive data leading to incisive development decisions. Accurate sample injection allowed continual 99% enantiomer separation after polarimetry optimization. We have developed an efficient SSR optimization methodology that offers rapid development of chiral separation by SSR.


Subject(s)
Chromatography, Liquid/methods , Ibuprofen/analysis , Pharmaceutical Preparations/analysis , Ibuprofen/isolation & purification , Pharmaceutical Preparations/isolation & purification , Stereoisomerism
7.
J Chromatogr A ; 1142(1): 81-3, 2007 Feb 16.
Article in English | MEDLINE | ID: mdl-17070821

ABSTRACT

Recent advancements in preparative HPLC have improved and streamlined compound purification. However, fraction evaporation remains a bottleneck within the process. An alternative to fraction evaporation is to remove the water and reduce the overall volume of the collection by trapping the fraction onto a solid phase extraction (SPE) cartridge. This method (as opposed to analytical applications involving SPE) works by collecting and then diluting the fraction(s), passing the fraction(s) through a SPE, drying the SPE with nitrogen and ultimately eluting the concentrated fraction(s) in a small amount of 100% organic solvent. An appreciable breakthrough is not observed using this method. In addition, recovery from the SPE for the tested compounds rosmarinic acid and carvacrol, two naturally occurring antioxidants in oregano, was found to be 95-98% for a 100mg injection via preparative HPLC purification at 50mg/compound.


Subject(s)
Antioxidants/isolation & purification , Chromatography, High Pressure Liquid/methods , Solid Phase Extraction/methods , Automation , Cinnamates/isolation & purification , Cymenes , Depsides/isolation & purification , Monoterpenes/isolation & purification , Rosmarinic Acid
SELECTION OF CITATIONS
SEARCH DETAIL
...