Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Blood Press Monit ; 29(3): 127-135, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38386314

ABSTRACT

BACKGROUND: Obtaining accurate and reliable blood pressure (BP) readings in pediatric patients is challenging, given difficulties in adhering to measurement guidelines, limited device validation and variable patient cooperation. This study aimed to investigate clinicians' perspectives surrounding noninvasive pediatric BP assessment to identify opportunities for improvement in BP technology and clinical practice. METHOD: Based on an adapted version of the extended Technology Acceptance Model 2, semi-structured interviews were conducted with clinicians involved in noninvasive pediatric BP assessment in a major Australian children's hospital. Transcripts were analyzed thematically and guided by Technology Acceptance Model 2. RESULTS: Clinician responses ( n  = 20) revealed that poor patient tolerance of BP measurement resulting from excessive cuff inflation is a major hindrance to reliable pediatric BP assessment. Clinicians described low trust in BP readings from automated devices, often relating to poor patient tolerance to cuff inflation, thereby diminishing the clinical utility of these readings in informing treatment decisions. Auscultatory measurement was regarded as more trustworthy and better tolerated, but less convenient to perform as compared with oscillometric measurement. CONCLUSION: A dissonance exists between (1) low trust and clinical utility of the most common and easy-to-use BP measurement approach (automated devices), versus (2) higher trust and clinical utility, but efficiency and user-related impediments, for the auscultatory method. Based on our results, we have developed the Blood Pressure Acceptance Model, which can be used to explain and predict clinicians' acceptance of BP technology. Further work is needed to improve the tolerability and accuracy of automated BP devices in real-world pediatric settings.


Subject(s)
Blood Pressure Determination , Humans , Child , Female , Male , Blood Pressure , Australia
2.
Open Heart ; 8(2)2021 10.
Article in English | MEDLINE | ID: mdl-34663749

ABSTRACT

OBJECTIVE: To describe normative values for blood pressure (BP) response to maximal exercise in children/adolescents undergoing a treadmill stress test. METHODS: From a retrospective analysis of medical records, patients who had undergone a Bruce protocol exercise stress test, with (1) normal cardiovascular system and (2) a body mass index percentile rank below 95% were included for analysis. Sex, age, height, weight, resting and peak heart rate, resting and peak systolic blood pressure (SBP), test duration, stage of Bruce protocol at termination, reason for undergoing the test and reason for termination of test were collected. Percentiles for exercise-induced changes in SBP were constructed by age and height for each sex with the use of quantile regression models. RESULTS: 648 patients with a median age of 12.4 years (range 6-18 years) were included. Typical indications for stress testing were investigation of potential rhythm abnormalities, syncope/dizziness and chest pain and were deemed healthy by an overseeing cardiologist. Mean test duration was 12.6±2.2 min. Reference percentiles for change in SBP by sex, age and height are presented. CONCLUSION: The presented reference percentiles for the change in SBP for normal children and adolescents will have utility for detecting abnormally high or low BP responses to exercise in these age groups.


Subject(s)
Blood Pressure/physiology , Body Height , Body Mass Index , Cardiovascular Diseases/physiopathology , Electrocardiography/methods , Exercise/physiology , Heart Rate/physiology , Adolescent , Cardiovascular Diseases/diagnosis , Cardiovascular Diseases/epidemiology , Child , Female , Humans , Incidence , Male , Reference Values , Retrospective Studies , Sex Factors , Victoria/epidemiology
SELECTION OF CITATIONS