Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Adv Healthc Mater ; 13(13): e2303444, 2024 05.
Article in English | MEDLINE | ID: mdl-38247306

ABSTRACT

The convergence of organoid and organ-on-a-chip (OoC) technologies is urgently needed to overcome limitations of current 3D in vitro models. However, integrating organoids in standard OoCs faces several technical challenges, as it is typically laborious, lacks flexibility, and often results in even more complex and less-efficient cell culture protocols. Therefore, specifically adapted and more flexible microfluidic platforms need to be developed to facilitate the incorporation of complex 3D in vitro models. Here, a modular, tubeless fluidic circuit board (FCB) coupled with reversibly sealed cell culture bricks for dynamic culture of embryonic stem cell-derived thyroid follicles is developed. The FCB is fabricated by milling channels in a polycarbonate (PC) plate followed by thermal bonding against another PC plate. LEGO-like fluidic interconnectors allow plug-and-play connection between a variety of cell culture bricks and the FCB. Lock-and-play clamps are integrated in the organoid brick to enable easy (un)loading of organoids. A multiplexed perfusion experiment is conducted with six FCBs, where thyroid organoids are transferred on-chip within minutes and cultured up to 10 d without losing their structure and functionality, thus validating this system as a flexible, easy-to-use platform, capable of synergistically combining organoids with advanced microfluidic platforms.


Subject(s)
Organoids , Organoids/cytology , Animals , Mice , Lab-On-A-Chip Devices , Polycarboxylate Cement/chemistry , Cell Culture Techniques/instrumentation , Cell Culture Techniques/methods , Thyroid Gland/cytology , Microfluidics/methods , Microfluidics/instrumentation , Embryonic Stem Cells/cytology
2.
Adv Healthc Mater ; 12(8): e2201555, 2023 03.
Article in English | MEDLINE | ID: mdl-36546709

ABSTRACT

Thyroid is a glandular tissue in the human body in which the function can be severely affected by endocrine disrupting chemicals (EDCs). Current in vitro assays to test endocrine disruption by chemical compounds are largely based on 2D thyroid cell cultures, which often fail to precisely evaluate the safety of these compounds. New and more advanced 3D cell culture systems are urgently needed to better recapitulate the thyroid follicular architecture and functions and help to improve the predictive power of such assays. Herein, the development of a thyroid organoid-on-a-chip (OoC) device using polymeric membranous carriers is described. Mouse embryonic stem cell derived thyroid follicles are incorporated in a microfluidic chip for a 4 day experiment at a flow rate of 12 µL min-1 . A reversible seal provides a leak-tight sealing while enabling quick and easy loading/unloading of thyroid follicles. The OoC model shows a high degree of functionality, where organoids retain expression of key thyroid genes and a typical follicular structure. Finally, transcriptional changes following benzo[k]fluoranthene exposure in the OoC device demonstrate activation of the xenobiotic aryl hydrocarbon receptor pathway. Altogether, this OoC system is a physiologically relevant thyroid model, which will represent a valuable tool to test potential EDCs.


Subject(s)
Organoids , Thyroid Gland , Animals , Humans , Mice , Cell Culture Techniques , Lab-On-A-Chip Devices
3.
Chem Soc Rev ; 39(8): 3102-14, 2010 Aug.
Article in English | MEDLINE | ID: mdl-20571676

ABSTRACT

Optical sensors, unlike most others, enable multiple sensing of (bio)chemical species by making use of probes whose signals can be differentiated by spectral and/or temporal resolution. Multiple sensors are of substantial interest for continuous monitoring of chemical parameters in complex samples such as blood, bioreactor fluids, in the chemical industry, aerodynamic research, and when monitoring food quality control, to mention typical examples. Moreover, such sensors enable non-invasive, non-toxic and online detection. We discuss in this critical review the state of the art in terms of spectroscopic principles, materials (mainly indicator probes and polymers), and give selected examples for dual and triple sensors along with a look into the future (109 references).


Subject(s)
Chemistry Techniques, Analytical/instrumentation , Fluorescent Dyes/chemistry , Molecular Imaging/methods , Fluorescent Dyes/chemical synthesis , Spectrometry, Fluorescence
5.
Chemistry ; 15(41): 10857-63, 2009 Oct 19.
Article in English | MEDLINE | ID: mdl-19760725

ABSTRACT

A new dual luminescent sensitive paint for barometric pressure and temperature (T) is presented. The green-emitting iridium(III) complex [Ir(ppy)(2)(carbac)] (ppy=2-phenylpyridine; carbac=1-(9H-carbazol-9-yl)-5,5-dimethylhexane-2,4-dione) was applied as a novel probe for T along with the red-emitting complex [Ir(btpy)(3)], (btpy=2-(benzo[b]thiophene-2-yl)pyridine) which functions as a barometric (in fact oxygen-sensitive) probe. Both iridium complexes were dissolved in different polymer materials to achieve optimal responses. The probe [Ir(ppy)(2)(carbac)] was dispersed in gas-blocking poly(acrylonitrile) microparticles in order to suppress any quenching of its luminescence by oxygen. The barometric probe [Ir(btpy)(3)], in turn, was incorporated in a cellulose acetate butyrate film which exhibits good permeability for oxygen. The effects of temperature on the response of the oxygen probe can be corrected by simultaneous optical determination of T, as the poly(acrylonitrile) microparticles containing the temperature indicator are incorporated into the film. The phosphorescent signals of the probes for T and barometric pressure, respectively, can be separated by optical filters due to the approximately 75 nm difference in their emission maxima. The dual sensor is applicable to luminescence lifetime imaging of T and barometric pressure. It is the first luminescent dual sensor material for barometric pressure/T based exclusively on the use of Ir(III) complexes in combination with luminescence lifetime imaging.


Subject(s)
Coloring Agents/chemistry , Iridium/chemistry , Paint , Luminescence , Models, Molecular , Molecular Structure , Temperature
6.
Chem Commun (Camb) ; (33): 5000-2, 2009 Sep 07.
Article in English | MEDLINE | ID: mdl-19668829

ABSTRACT

The pH sensor exploits the phenomenon of upconversion luminescence and is based on a hydrogel matrix containing (a) nanorods of the NaYF(4):Er,Yb type that can be excited with 980-nm laser light to give a green and red (dual) emission, and (b) a longwave absorbing pH probe that causes a pH-dependent inner filter effect.

7.
Anal Bioanal Chem ; 393(4): 1199-207, 2009 Feb.
Article in English | MEDLINE | ID: mdl-18998117

ABSTRACT

Chemical sensing, imaging and microscopy based on the use of fluorescent probes has so far been limited almost exclusively to the detection of a single parameter at a time. We present a scheme that can overcome this limitation by enabling optical sensing of two parameter simultaneously and even at identical excitation and emission wavelengths of two probes provided (a) their decay times are different enough to enable two time windows to be recorded, and (b) the emission of the shorter-lived probe decays to below the detectable limit while that of the other still can be measured. We refer to this new scheme as the dual lifetime determination (DLD) method and show that it can be widely varied by appropriate choice of probes and experimental settings. DLD is demonstrated to work by sensing oxygen and temperature independently from each other by making use of two probes, one for oxygen (a platinum porphyrin dissolved in polystyrene), and one for temperature [a europium complex dissolved in poly(vinyl methylketone)]. DLD was applied to monitor the consumption of oxygen in the glucose oxidase-catalyzed oxidation of glucose at varying temperatures. The scheme is expected to have further applications in cellular assays and biophysical imaging.


Subject(s)
Enzymes/metabolism , Molecular Probes , Temperature , Enzymes/chemistry , Luminescence , Oxygen/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...