Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 283
Filter
1.
Article in English | MEDLINE | ID: mdl-38752963

ABSTRACT

BACKGROUND: Pulmonary vein isolation is an effective treatment for atrial fibrillation (AF). Cryoballoon ablation using the Arctic Front cryoballoon (Medtronic) was found to be superior to antiarrhythmic drug treatment. Recently, a novel cryoballoon system was introduced (PolarX, Boston Scientific). OBJECTIVES: The purpose of this study was to compare the efficacy and safety of the 2 cryoballoons in a randomized controlled trial. METHODS: Patients with symptomatic paroxysmal AF were enrolled in 2 centers and randomized 1:1 to pulmonary vein isolation using the PolarX or the Arctic Front cryoballoon. All patients received an implantable cardiac monitor. The primary endpoint was first recurrence of atrial tachyarrhythmia (AF, atrial flutter, or atrial tachycardia [AT]) between days 91 and 365. Procedural safety was assessed by a composite of tamponade, phrenic nerve palsy lasting >24 hours, vascular complications, stroke/transient ischemic attack, atrioesophageal fistula or death up to 30 days. RESULTS: A total of 201 patients were enrolled. At 1 year, recurrence of atrial tachyarrhythmia had occurred in 41 of 99 patients (41.6%) assigned to the PolarX group and in 48 of 102 patients (47.1%) assigned to the Arctic Front group (HR: 0.85 [95% CI: 0.56-1.30]; P = 0.03 for noninferiority; P = 0.46 for superiority). The safety endpoint occurred in 5 patients (5%) in the PolarX group (n = 5 phrenic nerve palsies lasting >24 hours), whereas no safety endpoints occurred in the Arctic Front group (P = 0.03). CONCLUSIONS: In this randomized controlled trial using implantable cardiac monitors for continuous rhythm monitoring, the novel PolarX cryoballoon was noninferior compared with the Arctic Front cryoballoon regarding efficacy. However, the PolarX balloon resulted in significantly more phrenic nerve palsies. (Comparison of PolarX and the Arctic Front Cryoballoons for PVI in Patients With Symptomatic Paroxysmal AF [COMPARE-CRYO]; NCT04704986).

2.
J Am Heart Assoc ; 13(11): e032465, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38804218

ABSTRACT

BACKGROUND: New methods to identify patients who benefit from a primary prophylactic implantable cardioverter-defibrillator (ICD) are needed. T-wave alternans (TWA) has been shown to associate with arrhythmogenesis of the heart and sudden cardiac death. We hypothesized that TWA might be associated with benefit from ICD implantation in primary prevention. METHODS AND RESULTS: In the EU-CERT-ICD (European Comparative Effectiveness Research to Assess the Use of Primary Prophylactic Implantable Cardioverter-Defibrillators) study, we prospectively enrolled 2327 candidates for primary prophylactic ICD. A 24-hour Holter monitor reading was taken from all recruited patients at enrollment. TWA was assessed from Holter monitoring using the modified moving average method. Study outcomes were all-cause death, appropriate shock, and survival benefit. TWA was assessed both as a contiguous variable and as a dichotomized variable with cutoff points <47 µV and <60 µV. The final cohort included 1734 valid T-wave alternans samples, 1211 patients with ICD, and 523 control patients with conservative treatment, with a mean follow-up time of 2.3 years. TWA ≥60 µV was a predicter for a higher all-cause death in patients with an ICD on the basis of a univariate Cox regression model (hazard ratio, 1.484 [95% CI, 1.024-2.151]; P=0.0374; concordance statistic, 0.51). In multivariable models, TWA was not prognostic of death or appropriate shocks in patients with an ICD. In addition, TWA was not prognostic of death in control patients. In a propensity score-adjusted Cox regression model, TWA was not a predictor of ICD benefit. CONCLUSIONS: T-wave alternans is poorly prognostic in patients with a primary prophylactic ICD. Although it may be prognostic of life-threatening arrhythmias and sudden cardiac death in several patient populations, it does not seem to be useful in assessing benefit from ICD therapy in primary prevention among patients with an ejection fraction of ≤35%.


Subject(s)
Death, Sudden, Cardiac , Defibrillators, Implantable , Electrocardiography, Ambulatory , Primary Prevention , Humans , Primary Prevention/methods , Male , Female , Death, Sudden, Cardiac/prevention & control , Death, Sudden, Cardiac/etiology , Middle Aged , Aged , Prospective Studies , Electrocardiography, Ambulatory/methods , Electric Countershock/instrumentation , Electric Countershock/adverse effects , Risk Assessment/methods , Risk Factors , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/physiopathology , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/prevention & control , Arrhythmias, Cardiac/mortality , Treatment Outcome , Predictive Value of Tests , Time Factors , Europe/epidemiology , Prognosis , Heart Rate/physiology
3.
Article in English | MEDLINE | ID: mdl-38819347

ABSTRACT

BACKGROUND: Catheter ablation for atrial fibrillation (AF) including pulmonary vein isolation and possibly further substrate ablation is the most common electrophysiological procedure. Severe complications are uncommon, but their detailed assessment in a large worldwide cohort is lacking. OBJECTIVES: The aim of this study was to determine the incidence of periprocedural severe complications and to provide a detailed characterization of the diagnostic evaluation and management of these complications in patients undergoing AF ablation. METHODS: Individual patient data were collected from 23 centers worldwide. Limited data were collected for all patients who underwent catheter ablation, and an expanded series of data points were collected for patients who experienced severe complications during periprocedural follow-up. Incidence, predictors, patient characteristics, management details, and overall outcomes of patients who experienced ablation-related complications were investigated. RESULTS: Data were collected from 23 participating centers at which 33,879 procedures were performed (median age 63 years, 30% women, 71% radiofrequency ablations). The incidence of severe complications (n = 271) was low (tamponade 6.8‰, stroke 0.97‰, cardiac arrest 0.41‰, esophageal fistula 0.21‰, and death 0.21‰). Age, female sex, a dilated left atrium, procedure duration, and the use of radiofrequency energy were independently associated with the composite endpoint of all severe complications. Among patients experiencing tamponade, 13% required cardiac surgery. Ninety-three percent of patients with complications were discharged directly home after a median length of stay of 5 days (Q1-Q3: 3-7 days). CONCLUSIONS: This large worldwide collaborative study highlighted that tamponade, stroke, cardiac arrest, esophageal fistula, and death are rare after AF ablation. Older age, female sex, procedure duration, a dilated left atrium, and the use of radiofrequency energy were associated with severe complications in this multinational cohort. One in 8 patients with tamponade required cardiac surgery.

4.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38693772

ABSTRACT

AIMS: Arrhythmia-induced cardiomyopathy (AiCM) represents a subtype of acute heart failure (HF) in the context of sustained arrhythmia. Clear definitions and management recommendations for AiCM are lacking. The European Heart Rhythm Association Scientific Initiatives Committee (EHRA SIC) conducted a survey to explore the current definitions and management of patients with AiCM among European and non-European electrophysiologists. METHODS AND RESULTS: A 25-item online questionnaire was developed and distributed among EP specialists on the EHRA SIC website and on social media between 4 September and 5 October 2023. Of the 206 respondents, 16% were female and 61% were between 30 and 49 years old. Most of the respondents were EP specialists (81%) working at university hospitals (47%). While most participants (67%) agreed that AiCM should be defined as a left ventricular ejection fraction (LVEF) impairment after new onset of an arrhythmia, only 35% identified a specific LVEF drop to diagnose AiCM with a wide range of values (5-20% LVEF drop). Most respondents considered all available therapies: catheter ablation (93%), electrical cardioversion (83%), antiarrhythmic drugs (76%), and adjuvant HF treatment (76%). A total of 83% of respondents indicated that adjuvant HF treatment should be started at first HF diagnosis prior to antiarrhythmic treatment, and 84% agreed it should be stopped within six months after LVEF normalization. Responses for the optimal time point for the first LVEF reassessment during follow-up varied markedly (1 day-6 months after antiarrhythmic treatment). CONCLUSION: This EHRA Survey reveals varying practices regarding AiCM among physicians, highlighting a lack of consensus and heterogenous care of these patients.


Subject(s)
Arrhythmias, Cardiac , Cardiomyopathies , Humans , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Female , Male , Cardiomyopathies/therapy , Cardiomyopathies/diagnosis , Cardiomyopathies/physiopathology , Middle Aged , Adult , Europe , Surveys and Questionnaires , Stroke Volume , Health Care Surveys , Anti-Arrhythmia Agents/therapeutic use , Practice Patterns, Physicians'/statistics & numerical data , Ventricular Function, Left , Catheter Ablation , Cardiologists
5.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38607938

ABSTRACT

AIMS: Atrial fibrillation (AF) recurs in about one-third of patients after catheter ablation (CA), mostly in the first year. Little is known about the electrophysiological findings and the effect of re-ablation in very late AF recurrences (VLR) after more than 1 year. The aim of this study was to determine the characteristics and outcomes of the first repeat CA after VLR of AF after index CA. METHODS AND RESULTS: We analysed patients from a prospective Swiss registry that underwent a first repeat ablation procedure. Patients were stratified depending on the time to recurrence after index procedure: early recurrence (ER) for recurrences within the first year and late recurrence (LR) if the recurrence was later. The primary endpoint was freedom from AF in the first year after repeat ablation. Out of 1864 patients included in the registry, 426 patients undergoing a repeat ablation were included in the analysis (28% female, age 63 ± 9.8 years, 46% persistent AF). Two hundred and ninety-one patients (68%) were stratified in the ER group and 135 patients (32%) in the LR group. Pulmonary vein reconnections were a common finding in both groups, with 93% in the ER group compared to 86% in the LR group (P = 0.052). In the LR group, 40 of 135 patients (30%) had a recurrence of AF compared to 90 of 291 patients (31%) in the ER group (log-rank P = 0.72). CONCLUSION: There was no association between the time to recurrence of AF after initial CA and the characteristics and outcomes of the repeat procedure.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Recurrence , Registries , Reoperation , Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/physiopathology , Atrial Fibrillation/diagnosis , Catheter Ablation/adverse effects , Catheter Ablation/methods , Female , Pulmonary Veins/surgery , Pulmonary Veins/physiopathology , Male , Middle Aged , Aged , Time Factors , Switzerland/epidemiology , Risk Factors , Treatment Outcome , Prospective Studies
6.
Heart Rhythm ; 2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38614192

ABSTRACT

BACKGROUND: Atrial fibrillation (AF) and heart failure frequently coexist. Prediction of left ventricular ejection fraction (LVEF) recovery after catheter ablation (CA) for AF remains difficult. OBJECTIVE: The purpose of this study was to evaluate the value of biomarkers, alone and in combination with the Antwerp score, to predict LVEF recovery after CA for AF. METHODS: Patients undergoing CA for AF with depressed LVEF (<50%) were included. Plasma levels of 13 biomarkers were measured immediately before CA. Patients were categorized into "responders" and "nonresponders" in a similar fashion to the Antwerp score performance derivation and validation cohorts. The predictive power of the biomarkers alone and combined in outcome prediction was evaluated. RESULTS: A total of 208 patients with depressed LVEF were included (median age 63 years; 39-19% female; median indexed left atrial volume 42 (33-52) mL/m2; median LVEF 43 (38-46)%). At a median follow-up time of 30 (20-34) months, 161 (77%) were responders and 47 (23%) were nonresponders. Of 13 biomarkers, -4-angiopoietin 2 (ANG2), growth differentiation factor 15 (GDF15), fibroblast growth factor 23, and myosin binding protein C3-were significantly different between responders and nonresponders (P ≤ .001) and their combination could predict the end point with an area under the curve of 0.72 (95% confidence interval [CI] 0.64-0.81) overall, 0.69 (95% CI 0.59-0.78) in heart failure with mildly reduced ejection fraction, and 0.88 (95% CI 0.77-0.98) in heart failure with reduced ejection fraction. Only ANG2 and GDF15 remained significantly associated with LVEF recovery after adjustment for age, sex, and Antwerp score and significantly improved the accuracy of the Antwerp score predictions (P < .001). The area under the curve of the Antwerp score in the outcome prediction improved from 0.75 (95% CI 0.67-0.83) to 0.78 (95% CI 0.70-0.86). CONCLUSION: A biomarker panel (ANG2 and GDF15) significantly improved the accuracy of the Antwerp score.

8.
Heart Rhythm O2 ; 5(2): 113-121, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38545324

ABSTRACT

Background: Infranodal conduction disorders are common after transcatheter aortic valve replacement (TAVR). Risk factors are incompletely understood. Objective: The purpose of this study was to assess the impact of valve implantation depth and calcium burden of the device landing zone on infranodal conduction intraprocedure pre- and post-TAVR. Methods: In all patients undergoing TAVR between June 2020 and June 2021, the His-ventricle (HV) interval was measured pre- and post-valve deployment. The difference between the 2 measurements defined delta HV, whereas infranodal conduction delay was defined as HV interval >55 ms. Valve implantation depth was measured as the distance between the aortic annular plane and the ventricular prosthesis end. Calcium burden was quantified as the volume of calcium in 6 regions of interest: the non-, right, and left coronary cusps (NCC, RCC, and LCC, respectively) and the corresponding regions of the left ventricular outflow tract (LVOT) underlying each cusp (LVOTNCC, LVOTRCC, LVOTLCC, respectively). Results: Of 101 patients (mean age 81 ± 5.7 years; 47% women), 37 demonstrated infranodal conduction delay intraprocedure post-TAVR. Overall, mean implantation depth was 5 ± 3.1 mm, median calcium volume was 2080 mm3 [interquartile range 632-2400]. Delta HV showed no correlation with implantation depth or calcium burden (r = -0.08 and r = 0.12, respectively). However, LVOTNCC calcification was a significant predictor for infranodal conduction delay post-valve deployment in a multivariable logistic regression model (odds ratio 1.62 per 100-mm3 increase (95% confidence interval 1.06-2.69; P = .04). Conclusion: Assessment of LVOTNCC calcification may identify patients at risk for infranodal conduction delay after TAVR, whereas implantation depth did not predict infranodal conduction delay.

10.
Article in English | MEDLINE | ID: mdl-38478165

ABSTRACT

BACKGROUND: CRAFT was an international, multicentre, randomised controlled trial across 11 sites in the United UK and Switzerland. Given the evidence that pulmonary vein triggers may be responsible for atrial flutter (AFL) as well as atrial fibrillation (AF), we hypothesised that cryoballoon pulmonary vein isolation (PVI) would provide greater symptomatic arrhythmia reduction than cavotricuspid isthmus (CTI) ablation, whilst also reducing the subsequent burden of AF. Twelve-month outcomes were previously reported. In this study, we report the extended outcomes of the CRAFT study to 36 months. METHODS: Patients with typical AFL and no evidence of AF were randomised 1:1 to cryoballoon PVI or radiofrequency CTI. All patients received an implantable loop recorder (ILR) for continuous cardiac rhythm monitoring. The primary outcome was time-to-symptomatic arrhythmia recurrence > 30 s. Secondary outcomes included time-to-first-AF episode ≥ 2 min. The composite safety outcome included death, stroke and procedural complications. RESULTS: A total of 113 patients were randomised to cryoballoon PVI (n = 54) or radiofrequency CTI ablation (n = 59). Ninety-one patients reconsented for extended follow-up beyond 12 months. There was no difference in the primary outcome between arms, with the primary outcome occurring in 12 PVI vs 11 CTI patients (HR 0.97; 95% CI 0.43-2.20; p = 0.994). AF ≥ 2 min was significantly less frequent in the PVI arm, affecting 26 PVI vs 36 CTI patients (HR 0.48; 95% CI 0.29-0.79; p = 0.004). The composite safety outcome occurred in 5 PVI and 6 CTI patients (p = 0.755). CONCLUSION: Cryoballoon PVI shows similar efficacy to radiofrequency CTI ablation in reducing symptomatic arrhythmia recurrence in patients presenting with isolated typical AFL but significantly reduces the occurrence of subsequent AF.

11.
Cardiovasc Digit Health J ; 5(1): 29-35, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38390580

ABSTRACT

Background: Multiple smart devices capable of automatically detecting atrial fibrillation (AF) based on single-lead electrocardiograms (SL-ECG) are presently available. The rate of inconclusive tracings by manufacturers' algorithms is currently too high to be clinically useful. Method: This is a prospective, observational study enrolling patients presenting to a cardiology service at a tertiary referral center. We assessed the clinical value of applying a smart device artificial intelligence (AI)-based algorithm for detecting AF from 4 commercially available smart devices (AliveCor KardiaMobile, Apple Watch 6, Fitbit Sense, and Samsung Galaxy Watch3). Patients underwent a nearly simultaneous 12-lead ECG and 4 smart device SL-ECGs. The novel AI algorithm (PulseAI, Belfast, United Kingdom) was compared with each manufacturer's algorithm. Results: We enrolled 206 patients (31% female, median age 64 years). AF was present in 60 patients (29%). Sensitivity and specificity for the detection of AF by the novel AI algorithm vs manufacturer algorithm were 88% vs 81% (P = .34) and 97% vs 77% (P < .001) for the AliveCor KardiaMobile, 86% vs 81% (P = .45) and 95% vs 83% (P < .001) for the Apple Watch 6, 91% vs 67% (P < .01) and 94% vs 82% (P < .001) for the Fitbit Sense, and 86% vs 82% (P = .63) and 94% vs 80% (P < .001) for the Samsung Galaxy Watch3, respectively. In addition, the proportion of SL-ECGs with an inconclusive diagnosis (1.2%) was significantly lower for all smart devices using the AI-based algorithm compared to manufacturer's algorithms (14%-17%), P < .001. Conclusion: A novel AI algorithm reduced the rate of inconclusive SL-ECG diagnosis massively while maintaining sensitivity and improving the specificity compared to the manufacturers' algorithms.

12.
Open Heart ; 11(1)2024 Jan 31.
Article in English | MEDLINE | ID: mdl-38302139

ABSTRACT

AIMS: Direct-acting oral anticoagulants (DOACs) have, to a substantial degree, replaced vitamin K antagonists (VKA) as treatments for stroke prevention in atrial fibrillation (AF) patients. However, evidence on the real-world causal effects of switching patients from VKA to DOAC is lacking. We aimed to assess the empirical incremental cost-effectiveness of switching patients to DOAC compared with maintaining VKA treatment. METHODS: The target trial approach was applied to the prospective observational Swiss-AF cohort, which enrolled 2415 AF patients from 2014 to 2017. Clinical data, healthcare resource utilisation and EQ-5D-based utilities representing quality of life were collected in yearly follow-ups. Health insurance claims were available for 1024 patients (42.4%). Overall survival, quality-of-life, costs from the Swiss statutory health insurance perspective and cost-effectiveness were estimated by emulating a target trial in which patients were randomly assigned to switch to DOAC or maintain VKA treatment. RESULTS: 228 patients switching from VKA to DOAC compared with 563 patients maintaining VKA treatment had no overall survival advantage over a 5-year observation period (HR 0.99, 95% CI 0.45, 1.55). The estimated gain in quality-adjusted life years (QALYs) was 0.003 over the 5-year period at an incremental costs of CHF 23 033 (€ 20 940). The estimated incremental cost-effectiveness ratio was CHF 425 852 (€ 387 138) per QALY gained. CONCLUSIONS: Applying a causal inference method to real-world data, we could not demonstrate switching to DOACs to be cost-effective for AF patients with at least 1 year of VKA treatment. Our estimates align with results from a previous randomised trial.


Subject(s)
Atrial Fibrillation , Stroke , Humans , Stroke/prevention & control , Cost-Benefit Analysis , Prospective Studies , Quality of Life , Vitamin K , Anticoagulants/adverse effects , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Atrial Fibrillation/drug therapy
13.
Europace ; 26(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38412340

ABSTRACT

The DF-4 defibrillator standard has been rapidly adopted due to its convenience at implantation. There are however trade-offs compared to the traditional DF-1 standard that are underappreciated. This viewpoint outlines the advantages and limitations of current defibrillator lead standards that should be kept in mind, as they impact the options that are available to deal with issues that may arise.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Heart Failure/therapy
14.
Article in English | MEDLINE | ID: mdl-38182965

ABSTRACT

BACKGROUND: Non-pulmonary vein (PV) ablation targets such as posterior wall isolation (PWI) have been tested in patients with persistent atrial fibrillation (AF). Pulsed-field ablation (PFA) offers a novel ablation technology possibly able to overcome the obstacles of incomplete PWI and concerns of damage to adjacent structures compared to thermal energy sources. Our aim was to assess procedural characteristics, safety, and mid-term outcomes of patients undergoing PWI using PFA in a clinical setting. METHODS: Patients undergoing PFA-PVI with PWI were included. First-pass isolation was controlled using a multipolar mapping catheter. RESULTS: One hundred consecutive patients were included (median age 69 [IQR 63-75] years, 33 females (33%), left atrial size 43 [IQR 39-47] mm, paroxysmal AF 24%). Median procedure time was 66 (IQR 59-77) min, and fluoroscopy time was 11 (8-14) min. PWI using PFA was achieved in 100% of patients with a median of 19 applications (IQR 14-26). There were no major complications. Overall, in 15 patients (15%), recurrent AF/AT was noted during a median follow-up of 144 (94-279) days. CONCLUSIONS: PWI using PFA appears safe and results in high acute isolation rates and high arrhythmia survival during mid-term follow-up. Further randomized trials are essential and warranted.

15.
Heart ; 110(3): 178-187, 2024 Jan 10.
Article in English | MEDLINE | ID: mdl-37714697

ABSTRACT

OBJECTIVE: To test the hypothesis that in recipients of primary prophylactic implantable cardioverter-defibrillators (ICDs), the non-planarity of ECG vector loops predicts (a) deaths despite ICD protection and (b) appropriate ICD shocks. METHODS: Digital pre-implant ECGs were collected in 1948 ICD recipients: 21.4% females, median age 65 years, 61.5% ischaemic heart disease (IHD). QRS and T wave three-dimensional loops were constructed using singular value decomposition that allowed to measure the vector loop planarity. The non-planarity, that is, the twist of the three-dimensional loops out of a single plane, was related to all-cause mortality (n=294; 15.3% females; 68.7% IHD) and appropriate ICD shocks (n=162; 10.5% females; 87.7% IHD) during 5-year follow-up after device implantation. Using multivariable Cox regression, the predictive power of QRS and T wave non-planarity was compared with that of age, heart rate, left ventricular ejection fraction, QRS duration, spatial QRS-T angle, QTc interval and T-peak to T-end interval. RESULTS: QRS non-planarity was significantly (p<0.001) associated with follow-up deaths despite ICD protection with HR of 1.339 (95% CI 1.165 to 1.540) but was only univariably associated with appropriate ICD shocks. Non-planarity of the T wave loop was the only ECG-derived index significantly (p<0.001) associated with appropriate ICD shocks with multivariable Cox regression HR of 1.364 (1.180 to 1.576) but was not associated with follow-up mortality. CONCLUSIONS: The analysed data suggest that QRS and T wave non-planarity might offer distinction between patients who are at greater risk of death despite ICD protection and those who are likely to use the defibrillator protection.


Subject(s)
Coronary Artery Disease , Defibrillators, Implantable , Myocardial Ischemia , Female , Humans , Aged , Male , Defibrillators, Implantable/adverse effects , Stroke Volume , Ventricular Function, Left , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/etiology , Electrocardiography/methods , Myocardial Ischemia/complications , Coronary Artery Disease/complications , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Risk Factors
17.
N Engl J Med ; 390(2): 107-117, 2024 Jan 11.
Article in English | MEDLINE | ID: mdl-37952132

ABSTRACT

BACKGROUND: Subclinical atrial fibrillation is short-lasting and asymptomatic and can usually be detected only by long-term continuous monitoring with pacemakers or defibrillators. Subclinical atrial fibrillation is associated with an increased risk of stroke by a factor of 2.5; however, treatment with oral anticoagulation is of uncertain benefit. METHODS: We conducted a trial involving patients with subclinical atrial fibrillation lasting 6 minutes to 24 hours. Patients were randomly assigned in a double-blind, double-dummy design to receive apixaban at a dose of 5 mg twice daily (2.5 mg twice daily when indicated) or aspirin at a dose of 81 mg daily. The trial medication was discontinued and anticoagulation started if subclinical atrial fibrillation lasting more than 24 hours or clinical atrial fibrillation developed. The primary efficacy outcome, stroke or systemic embolism, was assessed in the intention-to-treat population (all the patients who had undergone randomization); the primary safety outcome, major bleeding, was assessed in the on-treatment population (all the patients who had undergone randomization and received at least one dose of the assigned trial drug, with follow-up censored 5 days after permanent discontinuation of trial medication for any reason). RESULTS: We included 4012 patients with a mean (±SD) age of 76.8±7.6 years and a mean CHA2DS2-VASc score of 3.9±1.1 (scores range from 0 to 9, with higher scores indicating a higher risk of stroke); 36.1% of the patients were women. After a mean follow-up of 3.5±1.8 years, stroke or systemic embolism occurred in 55 patients in the apixaban group (0.78% per patient-year) and in 86 patients in the aspirin group (1.24% per patient-year) (hazard ratio, 0.63; 95% confidence interval [CI], 0.45 to 0.88; P = 0.007). In the on-treatment population, the rate of major bleeding was 1.71% per patient-year in the apixaban group and 0.94% per patient-year in the aspirin group (hazard ratio, 1.80; 95% CI, 1.26 to 2.57; P = 0.001). Fatal bleeding occurred in 5 patients in the apixaban group and 8 patients in the aspirin group. CONCLUSIONS: Among patients with subclinical atrial fibrillation, apixaban resulted in a lower risk of stroke or systemic embolism than aspirin but a higher risk of major bleeding. (Funded by the Canadian Institutes of Health Research and others; ARTESIA ClinicalTrials.gov number, NCT01938248.).


Subject(s)
Anticoagulants , Aspirin , Atrial Fibrillation , Embolism , Stroke , Aged , Aged, 80 and over , Female , Humans , Male , Anticoagulants/adverse effects , Anticoagulants/therapeutic use , Aspirin/adverse effects , Aspirin/therapeutic use , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Canada , Embolism/etiology , Embolism/prevention & control , Hemorrhage/chemically induced , Pyridones/adverse effects , Stroke/etiology , Stroke/prevention & control , Treatment Outcome , Factor Xa Inhibitors/adverse effects , Factor Xa Inhibitors/therapeutic use , Double-Blind Method
19.
J Am Heart Assoc ; 12(21): e031872, 2023 11 07.
Article in English | MEDLINE | ID: mdl-37929709

ABSTRACT

Background Optimizing health-related quality of life (HRQoL) is an important aim of atrial fibrillation (AF) treatment. Little is known about patients' long-term HRQoL trajectories and the impact of patient and disease characteristics. The aim of this study was to describe HRQoL trajectories in an observational AF study population and in clusters of patients with similar patient and disease characteristics. Methods and Results We used 5-year follow-up data from the Swiss-Atrial Fibrillation prospective cohort, which enrolled 2415 patients with prevalent AF from 2014 to 2017. HRQoL data, collected yearly, comprised EuroQoL-5 dimension utilities and EuroQoL visual analog scale scores. Patient clusters with similar characteristics at enrollment were identified using hierarchical clustering. HRQoL trajectories were analyzed descriptively and with inverse probability-weighted regressions. Effects of postbaseline clinical events were additionally assessed using time-shifted event variables. Among 2412 (99.9%) patients with available baseline HRQoL, 3 clusters of patients with AF were identified, which we characterized as follows: "cardiovascular dominated," "isolated symptomatic," and "severely morbid without cardiovascular disease." Utilities and EuroQoL visual analog scale scores remained stable over time for the full population and the clusters; isolated symptomatic patients showed higher levels of HRQoL. Utilities were reduced after occurrences of stroke, hospitalization for heart failure, and bleeding, by -0.12 (95% CI, -0.18 to -0.06), -0.10 (95% CI, -0.13 to -0.08), and -0.06 (95% CI, -0.08 to -0.04), respectively, on a 0 to 1 utility scale. Utility of surviving patients returned to preevent levels 4 years after heart failure hospitalization; 3 years after bleeding; and 1 year after stroke. Conclusions In patients with prevalent AF, HRQoL was stable over time, irrespective of baseline patient characteristics. Clinical events of hospitalization for heart failure, stroke, and bleeding had only a temporary effect on HRQoL.


Subject(s)
Atrial Fibrillation , Heart Failure , Stroke , Humans , Atrial Fibrillation/epidemiology , Quality of Life , Prospective Studies , Hemorrhage
20.
Europace ; 25(12)2023 12 06.
Article in English | MEDLINE | ID: mdl-38036293

ABSTRACT

AIMS: Pulsed-field ablation (PFA) has emerged as a novel treatment technology for patients with atrial fibrillation (AF). Cryoballoon (CB) is the most frequently used single shot technology. A direct comparison to a novel CB system is lacking. We aimed to compare pulmonary vein isolation (PVI) using PFA vs. a novel CB system regarding efficiency, safety, myocardial injury, and outcomes. METHODS AND RESULTS: One hundred and eighty-one consecutive patients underwent PVI and were included (age 64 ± 9.7 years, ejection fraction 0.58 ± 0.09, left atrial size 40 ± 6.4 mm, paroxysmal AF 64%). 106 patients (59%) underwent PFA (FARAPULSE, Boston Scientific) and 75 patients (41%) underwent CB ablation (PolarX, Boston Scientific). The median procedure time, left atrial dwell time and fluoroscopic time were similar between the PFA and the CB group with 55 [interquartile range (IQR) 43-64] min vs. 58 (IQR 48-69) min (P < 0.087), 38 (30-49) min vs. 37 (31-48) min, (P = 0.871), and 11 (IQR 9.3-14) min vs. 11 (IQR 8.7-16) min, (P < 0.81), respectively. Three procedural complications were observed in the PFA group (two tamponades, one temporary ST elevation) and three complications in the CB group (3× reversible phrenic nerve palsies). During the median follow-up of 404 days (IQR 208-560), AF recurrence was similar in the PFA group and the CB group with 24 vs. 30%, P = 0.406. CONCLUSION: Procedural characteristics were very similar between PFA and CB in regard to procedure duration fluoroscopy time and complications. Atrial fibrillation free survival did not differ between the PFA and CB groups.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Humans , Middle Aged , Aged , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Pulmonary Veins/surgery , Cryosurgery/adverse effects , Cryosurgery/methods , Treatment Outcome , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
SELECTION OF CITATIONS
SEARCH DETAIL
...