Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 24
Filter
1.
Ann Hematol ; 100(3): 809-816, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33496839

ABSTRACT

Adult acute lymphoblastic leukemia/lymphoma (ALL/LBL) is a rare and heterogeneous malignancy characterized by uncontrolled proliferation of B or T cell precursor cells. Here, we retrospectively analyzed the outcome of early autologous stem cell transplantation in standard-risk patients in first complete remission (n=24) and of allogeneic transplantation in high and highest risk, and relapsed/refractory patients (n=35). The 10-year overall survival after autologous transplantation was 45%. The 10-year overall survival after allogeneic transplantation was 58%. The cumulative incidence of relapse was 29% after allogeneic and 67% after autologous transplantation. The cumulative incidence of non-relapse mortality was 0% after autologous and 12% after allogeneic transplantation. This retrospective single center analysis in a limited number of standard-risk patients clearly demonstrates that early autologous transplantation in first complete remission leads to an acceptable long-term outcome with a short overall treatment duration of less than 6 months compared with more than 2 years with conventional chemotherapy. More sensitive and standardized methods to detect minimal residual disease (MRD) will further help to identify those patients more accurately who are most likely to benefit from such a short and intensive treatment strategy (i.e., MRD negative standard-risk patients) or those who require early targeted therapy (e.g., blinatumomab) in case of MRD positivity. Early allogeneic transplantation results in long-term survival/cure in nearly two-thirds of all high and highest risk, and relapsed/refractory patients.


Subject(s)
Early Medical Intervention , Peripheral Blood Stem Cell Transplantation/methods , Precursor Cell Lymphoblastic Leukemia-Lymphoma/therapy , Adolescent , Adult , Aged , Austria/epidemiology , Early Medical Intervention/methods , Female , Humans , Male , Middle Aged , Neoplasm, Residual , Peripheral Blood Stem Cell Transplantation/adverse effects , Peripheral Blood Stem Cell Transplantation/statistics & numerical data , Precursor Cell Lymphoblastic Leukemia-Lymphoma/epidemiology , Precursor Cell Lymphoblastic Leukemia-Lymphoma/pathology , Recurrence , Remission Induction , Retrospective Studies , Time Factors , Time-to-Treatment , Transplantation, Autologous , Transplantation, Homologous , Treatment Outcome , Young Adult
2.
Clin Hemorheol Microcirc ; 43(1-2): 83-94, 2009.
Article in English | MEDLINE | ID: mdl-19713603

ABSTRACT

PURPOSE: This study compared the efficacy of contrast-enhanced ultrasound (CEUS) using a second generation contrast medium versus CT or MRA in the assessment of vascular and biliary complications in postoperative follow-up of liver transplantation. METHODS AND MATERIALS: The study group consisted of 36 consecutive liver transplant recipients who underwent post-transplantation CEUS examination after developing ascites and/or unclear liver function tests. Real time CEUS was performed after a bolus injection of SonoVue (1.6-2.4 ml, Bracco, Imaging Germany) followed by 10 ml of saline solution. Using contrast harmonic imaging (CHI) technique (Logiq 9, GE) with a 2.5-4-MHz transducer, a low mechanical index was chosen to avoid early destruction of the microbubbles (MI 0.1-0.2). In order to confirm the results, the patients underwent contrast-enhanced MRI or CT. RESULTS: Complications were identified in 16 of 36 patients (44.4%). Five transplants (14%) had hepatic artery thrombosis (n=2) or significant stenosis (n=3). Six transplants (16%) developed portal vein stenosis (n=4) or portal vein thrombosis (n=2). MRI or CT confirmed the findings of the CEUS in all 11 cases. Biliary stricture at the anastomotic site was detected in 5 patients. MR-CP confirmed the findings of all strictures. CONCLUSION: Due to advances in contrast-enhanced US, vascular and biliary complications in the postoperative period following liver transplantation can be reliably diagnosed non-invasively on the intensive care unit. CEUS shows vascular as well as biliary complications in the postoperative patient with a high degree of accuracy.


Subject(s)
Contrast Media , Liver Transplantation/adverse effects , Liver Transplantation/diagnostic imaging , Biliary Tract/blood supply , Biliary Tract/diagnostic imaging , Female , Humans , Liver/blood supply , Liver/diagnostic imaging , Magnetic Resonance Imaging , Male , Middle Aged , Postoperative Period , Prospective Studies , Tomography, X-Ray Computed , Ultrasonography
3.
Clin Hemorheol Microcirc ; 41(3): 151-68, 2009.
Article in English | MEDLINE | ID: mdl-19276513

ABSTRACT

Endoleaks following endovascular aneurysm repair (EVAR) are common and present a diagnostic challenge in the follow-up after EVAR. Contrast-enhanced ultrasound (CEUS) with low mechanical index (low MI) is a promising new method for the diagnosis and follow-up of endoleaks. CEUS with SonoVue allows a more rapid and noninvasive diagnosis, especially in critical patients owing to its bedside availability. This review describes the etiology, classification and importance of different types of endoleaks and compares CEUS findings with computed tomography angiography (CTA), allowing the reader to appreciate the usefulness of CEUS in this clinical situation.


Subject(s)
Aortic Aneurysm, Abdominal/diagnostic imaging , Hemorrhage/diagnostic imaging , Tomography, X-Ray Computed/methods , Angiography/methods , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Abdominal/surgery , Contrast Media , Hemorrhage/etiology , Humans , Ultrasonography/methods
4.
Clin Hemorheol Microcirc ; 39(1-4): 133-46, 2008.
Article in English | MEDLINE | ID: mdl-18503119

ABSTRACT

Aneurysms of the extracranial carotid arteries are a rare abnormalitiy and may represent a diagnostic challenge in examination of the patients. B-flow is a new digital vascular ultrasound technique and is an especially reliable method in the diagnosis of the extracranial portion of the internal carotid arteries as it shows less flow artifacts than color-coded Doppler sonography (CCDS) and power Doppler (PD). This review compares color-coded Doppler sonography, power Doppler and B-flow findings in extracranial ICA and CA aneurysm to emphasize the usefulness of B-flow in this clinical condition.


Subject(s)
Aneurysm/diagnostic imaging , Aneurysm/diagnosis , Carotid Artery, Internal/pathology , Magnetic Resonance Angiography/methods , Ultrasonography, Doppler, Color/methods , Aged , False Positive Reactions , Female , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Angiography/instrumentation , Male , Middle Aged , Reproducibility of Results , Software
5.
Clin Hemorheol Microcirc ; 39(1-4): 147-54, 2008.
Article in English | MEDLINE | ID: mdl-18503120

ABSTRACT

We report the case of a 61-year-old patient admitted to our hospital owing to recent nonspecific abdominal pain. Five years earlier he had been treated with a graft owing to thoracic and abdominal aortic aneurysm with dissection. He now showed a left renal vein aneurysm with a diameter of 11x7.5 cm. This case demonstrates that contrast enhanced ultrasound (CEUS), employed in addition to computed tomography angiography, offers a promising new option for diagnosis and preoperative treatment planning in patients with abdominal vascular diseases. The results were compared with operative findings.


Subject(s)
Aneurysm/pathology , Aorta, Abdominal/pathology , Arteriovenous Fistula/pathology , Contrast Media/pharmacology , Renal Veins/pathology , Tomography, X-Ray Computed/methods , Aneurysm/diagnosis , Aneurysm/diagnostic imaging , Angiography/methods , Arteriovenous Fistula/diagnosis , Arteriovenous Fistula/diagnostic imaging , Diagnostic Imaging/methods , Humans , Male , Middle Aged , Renal Veins/diagnostic imaging , Ultrasonography/methods
6.
Clin Hemorheol Microcirc ; 39(1-4): 155-69, 2008.
Article in English | MEDLINE | ID: mdl-18503121

ABSTRACT

To evaluate the effectiveness of contrast-enhanced ultrasound (CEUS) in the diagnosis and characterization of hepatic, renal and splenic traumatic injuries versus conventional ultrasound (US) and multislice computed tomography (MS-CT). Between January 2005 and January 2007, 78 patients (48 males, 30 females, mean age 56 years) with blunt abdominal trauma were examined by conventional US, CEUS and MS-CT. CEUS employed a low-MI technique using 1.2 to 2.4 ml of SonoVue (Bracco, Italy) i.v. and a multifrequency transducer (2-4 MHz, Siemens, Sequoia, Acuson). CT examinations were performed on a 64 detector CT scanner (Somatom Sensation 16 or 64, Siemens Medical Systems, Forchheim, Germany) before and after administration of 120 ml intravenous contrast agent (Solutrast, Bracco, Milan, Italy) followed by 50 ml saline. The presence of hepatic, renal and splenic injuries was analyzed and the conspicuousness of findings was assessed. In 15 of the 78 patients conventional US identified solid organ injuries: 8 hepatic, 2 renal and 5 splenic injuries. CEUS identified 3 more injuries (2 hepatic and 1 splenic) that had been missed by conventional US. CEUS identified traumatic lesions in 18/78 patients. In one of the 18 patients even active bleeding could be identified by CEUS. In CEUS solid organ injuries appeared hypoechoic. MS-CT identified 18 solid organ injuries in 78 patients, corroborating the CEUS results.CEUS greatly improves the visualization and characterization of hepatic, renal and splenic injuries compared to conventional ultrasound and correlates well with MS-CT. The imaging technique detects even minor blood flow and is able to depict vascular structures in detail. At our institution it is used as an additional examination technique which supplements MS-CT in unclear cases. Owing to its bedside availability, CEUS provides a good alternative to MS-CT, especially in patients with contraindications to CT contrast agents (e.g. due to renal failure or severe allergy) and in hemodynamically compromised patients.


Subject(s)
Abdominal Injuries/diagnostic imaging , Contrast Media/pharmacology , Ultrasonography/methods , Wounds, Nonpenetrating/diagnostic imaging , Abdomen , Abdominal Injuries/diagnosis , Adult , Female , Hematoma/diagnosis , Humans , Kidney/diagnostic imaging , Kidney/injuries , Liver/diagnostic imaging , Liver/injuries , Male , Middle Aged , Spleen/diagnostic imaging , Spleen/injuries , Tomography, X-Ray Computed/methods , Wounds, Nonpenetrating/diagnosis
7.
Radiologe ; 48(3): 272-80, 2008 Mar.
Article in German | MEDLINE | ID: mdl-17273820

ABSTRACT

Vascular ultrasound has been proven to be effective in the assessment of hemodialysis fistulas providing noninvasive diagnostic work-up of vascular morphology and hemodynamics. The most common reason for hemodialysis fistula failure is thrombosis due to stenosis. Therefore, early identification of stenosis is essential to avoid complications. Ultrasound-based identification of hypoechoic plaques and intimal proliferation helps to reach therapeutic decisions. An estimation of the grade of stenosis is also feasible. An occlusion rate of up to 45% due to reduced blood flow justifies follow-up examinations. Due to frequent puncture of the fistula the risk of hemodynamically relevant stenoses is increased. Establishment of new ultrasound methods like B-flow and advanced dynamic flow (ADF) enable direct visualization of the flow in the area of the anastomosis. In addition, high-resolution ultrasound techniques allow improved flow detection without aliasing. Our report addresses the topics of examination strategy, possible complications, and treatment like percutaneous intervention techniques.


Subject(s)
Arteriovenous Shunt, Surgical/adverse effects , Blood Vessels/diagnostic imaging , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/etiology , Renal Dialysis/adverse effects , Ultrasonography/methods , Humans
8.
Clin Hemorheol Microcirc ; 36(4): 313-8, 2007.
Article in English | MEDLINE | ID: mdl-17502701

ABSTRACT

Renal cancer represents accounts for approximately 3% of all adult malignancies with a rising incidence. Incidental diagnosis is mostly based upon ultrasound (US). US and Computed tomography (CT) are the standard imaging modalities for detecting renal cell cancer (RCC). Differentiation between malignant and benign renal tumors is of utmost importance. Contrast enhanced ultrasound (CUS) seems to be a promising new diagnostic option for diagnosis and preoperative treatment planning for patients with renal cancer. It is an additional examination to baseline ultrasound and CT. We report a case of a 37-year-old woman with a papillary renal cell cancer in which CUS helped to differentiate dignity of the tumor. CUS is an additional examination to baseline ultrasound and CT. It is a less invasive technique than contrast enhanced CT and shows even slight tumor blood flow. In addition it may allow a more rapid diagnosis, because of its bedside availability.


Subject(s)
Contrast Media , Image Enhancement , Kidney Neoplasms/diagnostic imaging , Adult , Female , Humans , Kidney Neoplasms/pathology , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Ultrasonography
9.
Hernia ; 11(3): 217-22, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17297569

ABSTRACT

BACKGROUND: Tension-free incisional hernia repair using alloplastic material increasingly replaces conventional repair techniques. This change resulted in a decreased recurrence rate (50% vs. 10%, respectively). Recently, laparoscopic approaches for the intraperitoneal tension-free mesh application have been introduced. The decreased trauma at the incision site and the reduction in wound infections appear to be the main advantages. The aim of the present study was to evaluate the early and long-term complications as well as patients' contentment. METHODS: Laparoscopic hernia repair with intraperitoneal polytetrafluroethylene (PTFE) mesh implantation was performed on 62 patients at the Klinikum Grosshadern between 2000 and 2005 (29 males, 33 females age 60.7). Intra- and postoperative complications were registered prospectively and retrospectively analyzed. In addition, 57 patients were evaluated for recurrence, postoperative pain and patient contentment (median follow-up 409 days). RESULTS: A low complication rate was observed in our patient collective. One trocar bleeding occurred. Three patients presented with wound hematoma. The recurrence rate was 8% (2/25). Sixty-two percent of the patients were free of complaints postoperatively. Eighty-five percent would once again choose the laparoscopic approach for incisional hernia repair. CONCLUSION: The laparoscopic technique was associated with a low recurrence rate, a small rate of wound infections and high patient comfort. Thus, the laparoscopic approach for mesh implantation appears to be a safe and effective method for the treatment of incisional hernias. The efficiency for laparoscopic intraperitoneal mesh implantation, however, should be further evaluated within a prospectively randomized multicenter trial.


Subject(s)
Hernia, Abdominal/surgery , Laparoscopy/methods , Laparotomy/methods , Prosthesis Implantation/instrumentation , Surgical Mesh , Decision Making , Female , Follow-Up Studies , Humans , Male , Middle Aged , Polytetrafluoroethylene , Prospective Studies , Retrospective Studies , Secondary Prevention , Time Factors , Treatment Outcome
10.
Cardiovasc Intervent Radiol ; 30(3): 480-4, 2007.
Article in English | MEDLINE | ID: mdl-17205366

ABSTRACT

An aorto-caval fistula is a rare complication of a symptomatic or ruptured infrarenal aortic aneurysm having a frequency of 3-6%. Patients typically present with clinical signs of diffuse abdominal pain associated with increasing venous congestion and tachycardia, rapid cardiopulmonary decompensation with acute dyspnea, and an audible machinerylike bruit. Perioperative mortality is high, ranging from 20% to 60%. We report a case of an endovascular aortic repair in a patient with a symptomatic infrarenal aortic aneurysm and an aorto-caval fistula. Contrast-enhanced ultrasound seems to be a promising new diagnostic option for the diagnosis and preoperative treatment planning for patients with abdominal aortic aneurysms with rupture into the inferior vena cava. It is in addition to computed tomography angiography. It might allow a more rapid and noninvasive diagnosis, especially for patients in intensive care because of its bedside availability. Because the examination is dynamic, additional information about blood flow between the aorta and inferior cava vein can be evaluated.


Subject(s)
Angioplasty , Aortic Aneurysm, Abdominal/surgery , Aortic Rupture/surgery , Aortography , Arteriovenous Fistula/surgery , Blood Vessel Prosthesis Implantation , Image Enhancement , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Stents , Tomography, X-Ray Computed , Ultrasonography, Doppler, Color , Vena Cava, Inferior/surgery , Aortic Aneurysm, Abdominal/diagnosis , Aortic Rupture/diagnosis , Arteriovenous Fistula/diagnosis , Contrast Media/administration & dosage , Humans , Middle Aged , Phospholipids , Postoperative Complications/diagnosis , Sulfur Hexafluoride
11.
Eur Radiol ; 17(11): 2991-3000, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17219146

ABSTRACT

Aortic abnormalities are commonly encountered and may represent a diagnostic challenge in patients with acute or chronic clinical symptoms. Contrast-enhanced ultrasound (CEUS) with low mechanical index (low MI) is a new promising method in the diagnosis and follow-up of pathological aortic lesions. CEUS with SonoVue allows a more rapid and noninvasive diagnosis, especially in critical patients because of its bedside availability. This review compares CEUS findings with those documented on computed tomography angiography (CTA), allowing the reader to appreciate the usefulness of CEUS in this clinical situation.


Subject(s)
Aorta/pathology , Aortic Diseases/diagnostic imaging , Aortic Diseases/diagnosis , Aortic Diseases/pathology , Contrast Media/pharmacology , Tomography, X-Ray Computed/methods , Ultrasonography/methods , Aortic Dissection/diagnosis , Aortic Dissection/diagnostic imaging , Aortic Dissection/pathology , Aortic Aneurysm, Abdominal/diagnosis , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/pathology , Fistula/diagnosis , Fistula/diagnostic imaging , Fistula/pathology , Humans , Tomography, X-Ray Computed/instrumentation , Ultrasonics , Ultrasonography/instrumentation
12.
Eur J Radiol ; 61(1): 144-9, 2007 Jan.
Article in English | MEDLINE | ID: mdl-16963219

ABSTRACT

OBJECTIVE: The objective of the study was to analyze the methods to reduce cost in interventional radiology departments by reorganizing procurement. MATERIALS AND METHODS: All products used in the Department of Interventional Radiology were inventoried. An ABC-analysis was completed and A-products (high-value and high turnover products) underwent a XYZ-analysis which predicted demand on the basis of ordering frequency. Then criteria for a procurement strategy for the different material categories were fixed. The net working capital (NWC) was calculated using an interest rate of 8%/year. RESULTS: Total annual material turnover was 353,000 euro. The value of all A-products determined by the inventory was 260,000 euro. Changes in the A-product procurement strategy tapped a cost reduction potential of 14,500/year euro. The resulting total saving was 17,200 euro. Improved stores management added another 37,500 euro. The total cost cut of 52,000 euro is equivalent to 14.7% of annual expenses. CONCLUSION: A flexible procurement strategy helps to reduce the storage and capital tie-up costs of A-products in interventional radiology without affecting the quality of service provided to patients.


Subject(s)
Cost Control/economics , Cost Control/methods , Decision Support Systems, Management , Materials Management, Hospital/economics , Models, Econometric , Purchasing, Hospital/economics , Radiology, Interventional/economics , Cost Savings , Cost-Benefit Analysis , Costs and Cost Analysis/economics , Costs and Cost Analysis/methods , Germany
13.
Cardiovasc Intervent Radiol ; 30(1): 111-5, 2007.
Article in English | MEDLINE | ID: mdl-17122888

ABSTRACT

We report the case of a patient who developed an asymptomatic pseudoaneurysm in the left external iliac artery after transplant nephrectomy. The pseudoaneurysm most probably arose as a suture aneurysm from the external iliac artery after removal of the graft renal artery. Obviously we can not exclude the possibility it was a true aneurysm, although this seems much less likely. The pseudoaneurysm was detected during a routine CT scan and was treated interventionally with a stent-graft. One month later the asymptomatic patient underwent a vascular ultrasound examination including color Doppler, power Doppler, and B-flow as a routine control. An endoleak with collapse of the stent-graft was diagnosed. There was no evidence of stent infection. At a reintervention, the pseudoaneurysm was successfully treated using two uncovered Palmaz stents at the proximal and distal edge of the stent graft. Peri- and post-interventional ultrasound and CT angiography confirmed the exclusion of the aneurysm without an endoleak.


Subject(s)
Aneurysm, False/surgery , Iliac Artery/surgery , Postoperative Complications/surgery , Prosthesis Failure , Stents/adverse effects , Adult , Aneurysm, False/diagnosis , Female , Humans , Iliac Artery/diagnostic imaging , Postoperative Complications/diagnosis , Tomography, X-Ray Computed/methods , Ultrasonography, Doppler/methods
14.
J Chemother ; 16(4): 372-80, 2004 Aug.
Article in English | MEDLINE | ID: mdl-15332713

ABSTRACT

Human malignant tumors, such as non-small lung, breast, ovarian, head and neck, prostate, stomach and colorectal cancers express a number of growth factor receptors (e.g. EGFR or EGFR family members) that are regulated by tumor hypoxia and contribute to tumor growth and failure of cytotoxic therapy. Paclitaxel and docetaxel are indispensable substances in the treatment of these tumors. Despite the active clinical use of taxanes, little is known about their cytotoxic activity under hypoxia. The aim of the present work was to compare the cytotoxic effect of taxanes, paclitaxel and docetaxel on the EGFR-expressing carcinoma cell lines A431, MDA-MB-231 and NCI-H358 under normoxic and hypoxic conditions. The two taxanes caused different cell cycle distribution and varying aneuploid cell formation under hypoxia. EGFR-overexpressing carcinoma cells showed hypoxia to severely affect the cytotoxicity of paclitaxel, whereas docetaxel preserved its tumor cell-killing activity even at lowest concentrations (0.5 nM), as was observed for both taxanes under normoxia.


Subject(s)
Antineoplastic Agents, Phytogenic/pharmacology , Apoptosis/drug effects , ErbB Receptors/drug effects , Paclitaxel/pharmacology , Taxoids/pharmacology , Apoptosis/physiology , Cell Cycle/drug effects , Cell Survival/drug effects , Docetaxel , Drug Resistance, Neoplasm , Female , Humans , Hypoxia , Male , Neoplasms/drug therapy , Neoplasms/pathology , Probability , Reference Values , Sensitivity and Specificity , Tumor Cells, Cultured
15.
Int J Artif Organs ; 25(10): 975-84, 2002 Oct.
Article in English | MEDLINE | ID: mdl-12456039

ABSTRACT

New approaches for in vitro testing of hepato-mediated toxicity are undertaken to offer alternatives to in vivo animal testing. The described bioassay for hepato-mediated toxicity testing is based on a small scale hepatocyte-bioreactor with pig hepatocytes connected to a silicon sensor based microphysiometer system for monitoring of the extracellular acidification rate (EAR) of cells and the microphysiometer alone. EAR represents the metabolic activity of tested cells (hepatocytes and ZR 751 cells) under the influence of perfused media, compared to controls, which were set to 100%. Cyclophosphamide (CYCL), whose cytostatic effect is dependent on CYP 450 biotransformation was used as a model substrate. CYCL showed decrease of EAR in hepatocytes, but not in ZR 751 cells. Bioreactor supernatant including CYCL was pumped into the microphysiometer and EARs of the target ZR 751 cell line were recorded. After 7 h of bioreactor supernatant perfusion the ZR 751 cell line showed an EAR decrease of 18.68% +/- 10.18, as compared to controls (bioreactor supernatant from the identical set-up without CYCL). Thus the presented model of hepato-activated toxicity showed an EAR decrease in the ZR 751 cell line that reflected the toxic activation of CYCL by the bioreactor. This new bioassay serves as an example of future applications for hepatocyte bioreactors in automated toxicity testing devices, e.g. in preclinical drug studies or evaluation of hepato-mediated toxicity, not depending on cell destruction or further assays.


Subject(s)
Biological Assay , Bioreactors , Cyclophosphamide/analogs & derivatives , Hepatocytes/metabolism , 7-Alkoxycoumarin O-Dealkylase/metabolism , Albumins/metabolism , Animals , Cell Line , Cyclophosphamide/toxicity , DNA/biosynthesis , Hydrogen-Ion Concentration , In Vitro Techniques , L-Lactate Dehydrogenase/metabolism , Swine
16.
Disabil Rehabil ; 24(1-3): 115-25, 2002.
Article in English | MEDLINE | ID: mdl-11827145

ABSTRACT

PURPOSE: It is generally accepted that electronic aids to daily living (EADLs) play an important role in the lives of many people with severe disabilities by providing the means to access and control devices for daily living activities. Despite this, little proof exists to support the contention that consumers are satisfied with relevant aspects of these assistive devices. The purpose of this study was to explore consumer satisfaction with EADLs and investigate the value that people with degenerative neuromuscular conditions place on these technologies. METHOD: Interviews were conducted with 40 EADL users and non-users to compare their views about these devices and their daily life experiences. Users were interviewed twice, six months apart, to establish the stability of their views and experiences with EADLs. The Functional Independence Measure (FIM instrument), the personal profile and Quebec User Evaluation of Satisfaction with assistive Technology (QUEST) were administered to determine functional levels of participants, gather personal data pertinent to the study of device utility and explore user satisfaction with EADLs. RESULTS: Results suggest that overall consumers were quite satisfied with their EADLs and that this was relatively stable over time. However, some consumers expressed concerns regarding the cost of these technologies and their associated services. Both users and non-users rated EADLs similarly in relation to relative degree of importance ascribed to them. CONCLUSIONS: Combining the QUEST with outcome measurement tools that explore other important dimensions such as the effect on quality of life and psychosocial impact will help service providers to justify the costs associated with the prescription of sophisticated, costly assistive devices such as EADLs.


Subject(s)
Activities of Daily Living , Consumer Behavior , Disabled Persons , Self-Help Devices , Adolescent , Adult , Female , Health Status Indicators , Humans , Male , Middle Aged , Muscular Dystrophies
17.
Med Pediatr Oncol ; 37(1): 36-41, 2001 Jul.
Article in English | MEDLINE | ID: mdl-11466721

ABSTRACT

BACKGROUND: Postoperative irradiation for locoregionally advanced neuroblastoma requires coverage of the paraspinal retroperitoneum. The proximity of both kidneys and the liver, and a more complex target configuration, can pose a dosimetric challenge for conventional X-ray treatment and intraoperative irradiation. We utilized proton radiation therapy (PRT) to reduce dose to uninvolved kidneys, liver, intestine, and spinal cord. PROCEDURE: A 4-year-old male underwent PRT for neuroblastoma of the right adrenal gland, following chemotherapy and delayed surgical resection. Clinical target volume (CTV), boost volume, and normal structures were outlined on the 3D treatment planning CT scan. The patient received 25.2 CGE (cobalt Gray equivalent) to the CTV and 34.2 CGE to the boost region, using 1.8 CGE per fraction, five treatments per week. Dose-volume histograms (DVHs) were obtained for target and nontarget structures. RESULTS: The 95% isodose volume enclosed CTV and boost volumes. The dose to 50% of the ipsilateral kidney, with tumor involvement of the medial renal surface, was < or = 16 CGE (47% of prescribed total dose). Doses to 50% and 20% of the contralateral kidney in close proximity to deep left-side, paraspinal soft tissue involvement were restricted to 1 CGE and 10 CGE, respectively. Eighty percent of the liver received 27 CGE (80% of prescribed dose). Using a patch technique, unique to charged particle therapy, the spinal cord was almost completely spared during boost volume irradiation. CONCLUSIONS: PRT can achieve excellent dose conformity for advanced retroperitoneal, paraspinal lesions, while respecting normal tissue tolerance levels.


Subject(s)
Neuroblastoma/radiotherapy , Protons , Radiotherapy, Conformal/methods , Retroperitoneal Neoplasms/radiotherapy , Child, Preschool , Humans , Male , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Treatment Outcome
18.
Strahlenther Onkol ; 177(1): 43-7, 2001 Jan.
Article in English | MEDLINE | ID: mdl-11200112

ABSTRACT

PURPOSE: To demonstrate why conventional non-invasive mouthpiece-based fixation has not achieved the expected accuracy and to suggest a solution of the problem. PATIENTS AND METHODS: The Vogele Bale Hohner (VBH) head holder is a non-invasive vacuum mouthpiece-based head fixation system. Feasibility and repositioning accuracy were evaluated by portal image analysis in 12 patients with cranial tumors intended for stereotactic procedures, fixated with the newest version (VBH HeadFix-ARC). RESULTS: Portal image analysis (8 patients evaluated in 2-D, 4 patients in 3-D) showed that even in routine external beam radiation therapy, treatment can be applied to within a mean 2-D and 3-D accuracy of under 2 mm (SD 0.92 mm and 1.2 mm, respectively) with cost and repositioning time per patient and patient comfort comparable to that of common thermoplastic masks. CONCLUSION: These preliminary results show that high repositioning accuracy does not rule out simple and quick application and patient comfort. Paramount, however, is tensionless repositioning via the vacuum mouthpiece.


Subject(s)
Brain Neoplasms/radiotherapy , Radiotherapy/instrumentation , Equipment Design , Humans , Patient Compliance , Posture , Radiotherapy/methods , Reproducibility of Results
19.
Int J Radiat Oncol Biol Phys ; 48(1): 147-51, 2000 Aug 01.
Article in English | MEDLINE | ID: mdl-10924984

ABSTRACT

PURPOSE: In prophylactic irradiation of infradiaphragmatic lymphatic nodes (LN), the width of the paraaortic and pelvic field is given by a line joining the tips of the transverse processes of the 11th thoracic to the 4th lumbar vertebrae. Then the field boundary follows a straight line to the most lateral point of the acetabulum seen on the simulation film. Another method of setting the field border is to project the lateral contours of the large abdominal vessels from T(1)-weighted coronal MR images of the abdomen onto the simulator radiographs and add a 2-cm margin along the so delineated vessels. In our study, we compared both methods as to full enclosure of paraaortic and pelvic lymphatics or nodal miss. MATERIAL AND METHODS: Abdominal CT scans of 81 patients with involvement of paraaortic lymph node regions with LN sizes not exceeding 2.5 cm were examined. The distance from the center of the appropriate vertebra to the center of the most lateral lymph node was referred to the transverse process as well as to the outside contour of the aorta on the left and the vena cava on the right side. Respectively, the LN were measured referenced to the iliac vessels from the 5th lumbar through to the 2nd sacral vertebra. At the level of the hip joint the distance was measured from the midline as determined by a line through the center of the sacrum, perpendicular to a line connecting center of both femoral heads. RESULTS: Our measurements showed that lymph nodes do occur (1) lateral to the transverse processes of the thoracic and lumbar vertebrae as well as (2) outside the 2-cm safety margin from the lateral contour of the large abdominal vessels. CONCLUSION: These data clearly show that the traditional fields for radiation of infradiaphragmatic lymphatic nodes have not been large enough to enclose almost all retroperitoneal and pelvic lymph nodes with certainty. We recommend an expansion of the fields.


Subject(s)
Lymphatic Irradiation/methods , Lymphoma/radiotherapy , Aorta, Abdominal , Hodgkin Disease/diagnostic imaging , Hodgkin Disease/radiotherapy , Humans , Lymph Nodes/diagnostic imaging , Lymph Nodes/pathology , Lymphoma/diagnostic imaging , Lymphoma, B-Cell/diagnostic imaging , Lymphoma, B-Cell/radiotherapy , Lymphoma, Non-Hodgkin/diagnostic imaging , Lymphoma, Non-Hodgkin/radiotherapy , Middle Aged , Radiotherapy, Adjuvant , Retroperitoneal Space/diagnostic imaging , Tomography, X-Ray Computed
20.
Int J Radiat Oncol Biol Phys ; 45(5): 1117-26, 1999 Dec 01.
Article in English | MEDLINE | ID: mdl-10613303

ABSTRACT

PURPOSE: Following adequate therapy, excellent long-term survival rates can be achieved for patients with optic pathway gliomas. Therefore, avoidance of treatment-related functional long-term sequelae is of utmost importance. Optimized sparing of normal tissue is of primary concern in the development of new treatment modalities. The present study compares proton radiation therapy (PRT) with a three-dimensional (3D)-planned multiport photon and a lateral beam photon technique for localized and extensive optic pathway tumors. METHODS AND MATERIALS: Between February 1992 and November 1997, seven children with optic pathway gliomas underwent PRT. For this study, we computed proton, 3D photon, and lateral photon plans based on the same CT data sets, and using the same treatment planning software for all plans. Radiation exposure for normal tissue and discrete organs at risk was quantified based on dose-volume histograms. RESULTS: Gross tumor volume (GTV) ranged from 3.9 cm3 to 127.2 cm3. Conformity index (relation of encompassing isodose to GTV volume) was 2.3 for protons, 2.9 for 3D photons, and 7.3 for lateral photons. The relative increase of normal tissue (NT) encompassed at several isodose levels in relation to NT encompassed by the 95% proton isodose volume was computed. Relative NT volume of proton plan isodoses at the 95%, 90%, 80%, 50%, and 25% isodose level increased from 1 to 1.6, 2.8, 6.4, to a maximum of 13.3. Relative volumes for 3D photons were 1.6, 2.4, 3.8, 11.5, and 34.8. Lateral plan relative values were 6, 8.3, 11.5, 19.2, and 26.8. Analysis for small (<20 cm3) and larger (> 80 cm3) tumors showed that protons encompassed the smallest volumes of NT at all isodose levels. Comparable conformity and high-dose gradient were achieved for proton and 3D photon plans in small tumors. However, with increasing tumor volume and complexity, differences became larger. At the 50% isodose level, 3D photons were superior to lateral photons for small tumors; this advantage was equalized for larger tumors. At the lowest isodose level, 3D photons encompassed the highest amount of NT. Analysis of organs at risk showed that PRT reduced doses to the contralateral optic nerve by 47% and 77% compared to 3D photons and lateral photons, respectively. Reductions were also seen for the chiasm (11% and 16%) and pituitary gland (13% and 16%), with differences at clinically relevant tolerance levels. Furthermore, reduced dose exposure of both temporal lobes (sparing 39% and 54%) and frontal lobes was achieved with PRT. CONCLUSION: PRT offered a high degree of conformity to target volumes and steep dose gradients, thus leading to substantial normal tissue sparing in high- and low-dose areas. It is expected that this will result in decreased long-term toxicity in the maturing child. Advantages of proton versus 3D photon plans became increasingly apparent with increasing target size and tumor complexity. Even in small tumors, conformity of 3D photon irradiation came at the expense of a larger amount of NT receiving moderate to low radiation doses. Lateral photons resulted in inferior dose distribution with high radiation exposure of clinically relevant normal tissues.


Subject(s)
Glioma/radiotherapy , Optic Chiasm , Optic Nerve Neoplasms/radiotherapy , Photons/therapeutic use , Proton Therapy , Radiotherapy, Conformal/methods , Child , Child, Preschool , Female , Follow-Up Studies , Glioma/pathology , Humans , Male , Optic Nerve Neoplasms/pathology , Radiation Injuries/prevention & control , Radiotherapy Dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...