Catheter Cardiovasc Interv ; 98(6): E823-E827, 2021 11 15.
Article in English | MEDLINE | ID: mdl-34415672

ABSTRACT

Delayed coronary obstruction is a rare but often fatal complication of transcatheter aortic valve replacement that can present within 24 hr after the transcatheter aortic valve replacement procedure. We present a case of a 77-year-old woman whose distal left main coronary artery bifurcation became obstructed by an embolized piece of native valve leaflet material 16 hours after the uncomplicated transfemoral implantation of an Edwards Sapien Ultra 23 mm aortic valve, which was successfully treated with the simultaneous kissing stent technique.


Subject(s)
Aortic Valve Stenosis , Coronary Occlusion , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/etiology , Coronary Occlusion/surgery , Female , Humans , Prosthesis Design , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome