Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Genes (Basel) ; 13(12)2022 12 14.
Article in English | MEDLINE | ID: mdl-36553626

ABSTRACT

Joint laxity is a multifactorial phenotype with a heritable component. Mutations or common polymorphisms within the α1(V) (COL5A1), α1(XI) (COL11A1) and α2(XI) (COL11A2) collagen genes have been reported or proposed to associate with joint hypermobility, range of motion and/or genu recurvatum. The aim of this study was to investigate whether polymorphisms within these collagen-encoding genes are associated with measurements of knee joint laxity and computed ligament length changes within the non-dominant leg. One hundred and six healthy participants were assessed for genu recurvatum (knee hyperextension), anterior-posterior tibial translation, external-internal tibial rotation and ligament length changes during knee rotation of their non-dominant leg. Participants were genotyped for COL5A1 rs12722 (T/C), COL11A1 rs3753841 (C/T), COL11A1 rs1676486 (T/C) and COL11A2 rs1799907 (A/T). The genotype-genotype combination of any two or more of the four COL5A1 rs12722 CC, COL11A1 rs3753841 CC, COL11A1 rs1676486 TT and COL11A2 rs1799907 AA genotypes was associated with decreased active and passive knee hyperextension. These genotype-genotype combinations, including sex (male), increased age and decreased body mass collectively, also contributed to decreased passive knee hyperextension. These findings suggest that COL5A1, COL11A1 and COL11A2 gene-gene interactions are associated with knee hyperextension measurements of the non-dominant leg of healthy individuals.


Subject(s)
Collagen , Joint Instability , Knee Joint , Humans , Male , Collagen/genetics , Genotype , Joint Instability/genetics , Knee Joint/physiopathology , Polymorphism, Genetic
2.
Clin Biomech (Bristol, Avon) ; 100: 105822, 2022 12.
Article in English | MEDLINE | ID: mdl-36436321

ABSTRACT

BACKGROUND: Joint laxity is a multifactorial phenotype with a heritable component. Type I collagen gene (COL1A1) mutations cause connective tissue disorders with joint hypermobility as a clinical feature, while variants within COL1A1 and type III collagen gene (COL3A1) are associated with musculoskeletal injuries. The aim of this study was to investigate whether COL1A1 and COL3A1 variants are associated with measurements of non-dominant knee joint laxity and computed ligament length changes. METHODS: 106 moderately active uninjured participants were assessed for genu recurvatum, anterior-posterior tibial translation, external-internal tibial rotation and calculated ligament length changes during knee rotation. Participants were genotyped for COL1A1 rs1107946, rs1800012 and COL3A1 rs1800255. FINDINGS: The COL1A1 rs1107946 GG genotype had significantly larger external rotation [GG: 5.7° (4.9°;6.4°) vs GT: 4.6° (4.2°;5.5°), adjusted P = 0.014], internal rotation [GG: 5.9° (5.3°;6.6°) vs GT: 5.4° (4.7°;6.2°), adjusted P = 0.014], and slack [GG: 18.2° ± 3.2° vs GT: 16.1° ± 3.1°, adjusted P = 0.014]. The GG genotype at both COL1A1 variants had significantly larger active displacement [GG + GG: 6.0 mm (3.8 mm;8.0 mm) vs other genotype combinations: 4.0 mm (2.5 mm;6.0 mm), P < 0.001] and maximum displacement [GG + GG: 8.0 mm (6.9 mm;10.6 mm) vs other genotype combinations: 6.0 mm (5.0 mm;9.0 mm), P = 0.003]. COL1A1 rs1107946 significantly contributed to increased external and internal rotation in multilinear regression models, while both COL1A1 variants, significantly contributed to increased active displacement and slack. Larger medial and lateral cruciate ligament length changes were reported in participants with GG genotypes at both COL1A1 variants. INTERPRETATION: These findings suggest that the COL1A1 variants are associated with knee rotational laxity and changes in ligament length.


Subject(s)
Collagen Type I, alpha 1 Chain , Collagen Type III , Joint Instability , Ligaments, Articular , Humans , Collagen Type III/genetics , Joint Instability/genetics , Joint Instability/pathology , Collagen Type I, alpha 1 Chain/genetics , Ligaments, Articular/pathology , Genetic Variation
3.
J Orthop Surg Res ; 17(1): 434, 2022 Sep 29.
Article in English | MEDLINE | ID: mdl-36175903

ABSTRACT

BACKGROUND: Shoulder stiffness resulting in motion loss can be caused by numerous conditions, the most common of which is adhesive capsulitis. Surgical intervention is often necessary when conservative methods fail. High-intensity stretch (HIS) treatment may be able to provide increased motion gains while avoiding the cost and complications of surgery. OBJECTIVES: The purpose of this study was to review data from patients who were prescribed a HIS device to recover their shoulder motion to determine the efficacy of the device. The hypotheses were that patients would achieve significant range of motion (ROM) gains and that ROM would increase to a level at which patients would be able to avoid a motion loss surgery and perform activities of daily living. METHODS: Clinical notes were reviewed for patients whose progress plateaued after 4 weeks of therapy and were subsequently prescribed the HIS device after failing to meet their treatment goals. ROM data were recorded for external rotation, abduction, forward flexion, and internal rotation. Pre- and post-treatment ROM data were compared using t-tests. RESULTS: Significant ROM gains were seen in all planes of motion (p < 0.001). Patients gained an average of 29.9° in external rotation with a last recorded rotation of 59.2°. In abduction, patients gained 40.5° with a last recorded abduction of 123.3°. In forward flexion, patients gained 30.3° with a last recorded flexion of 138.7°. In internal rotation, patients gained 15.2° with a last recorded rotation of 57.6°. These last recorded ranges of motion were sufficient to perform nearly all activities of daily living. CONCLUSIONS: The HIS device was effective in treating patients with shoulder motion loss as demonstrated by the significant ROM gains in all planes of motion. The ability for a patient to recover lost motion quickly without surgery is of great value to quality of life and in healthcare cost savings. We believe this high-intensity stretch device should be considered for use by patients who are at risk for a motion loss surgery.


Subject(s)
Shoulder Joint , Shoulder , Activities of Daily Living , Humans , Quality of Life , Range of Motion, Articular , Retrospective Studies , Shoulder Joint/surgery , Treatment Outcome
4.
J Orthop Surg Res ; 17(1): 337, 2022 Jul 06.
Article in English | MEDLINE | ID: mdl-35794671

ABSTRACT

BACKGROUND: Recovery from knee surgery or injury can be hindered by knee arthrofibrosis, which can lead to motion limitations, pain and delayed recovery. Surgery or prolonged physical therapy are often treatment options for arthrofibrosis, but they can result in increased costs and decreased quality of life. A treatment option that can regain lost motion without surgery would help minimize risks and costs for the patient. The purpose of this study was to determine treatment efficacy of high-intensity home mechanical stretch therapy in patients with knee arthrofibrosis. METHODS: Records were reviewed for 11,000+ patients who were prescribed a high-intensity stretch device to regain knee flexion. Initial and last recorded knee flexion and days between measurements were available for 9842 patients (Dataset 1). Dataset 2 was a subset of 966 patients from Dataset 1. These 966 patients had separate more rigorous measurements available from physical therapy notes (Dataset 3) in addition to data from the internal database (Dataset 2). Within and between dataset statistics were calculated using t tests for comparison of means and Cohen's d for determination of effect size. RESULTS: All dataset showed significant gains in flexion (p < 0.01). Mean initial flexion, last recorded flexion and flexion gain were 79.5°, 108.4°, and 29.9°, respectively in Dataset 1. Differences between Datasets 2 and 3 had small effect sizes (Cohen's d < 0.17). The were no significant differences when comparing workers' compensation and non-workers' compensation patients. The average last recorded flexion for all datasets was above the level required to perform activities of daily living. Motion gains were recorded in under 60 days from device delivery. CONCLUSIONS: High-intensity home mechanical stretch therapy was effective in restoring knee flexion, generally in 2 months or less, and in avoiding additional surgery in severe motion loss patients regardless of sex, age, or workers' compensation status. We believe high-intensity stretching should be considered in any patient who is at risk for a secondary motion loss surgery, because in over 90% of these patients, the complications and costs associated with surgery can be avoided.


Subject(s)
Activities of Daily Living , Joint Diseases , Humans , Joint Diseases/therapy , Knee Joint , Quality of Life , Retrospective Studies
5.
Sports Med Open ; 6(1): 33, 2020 Aug 03.
Article in English | MEDLINE | ID: mdl-32748169

ABSTRACT

BACKGROUND: Several clinical tests exist to assess knee laxity. Although these assessments are the predominant tools of diagnosis, they are subjective and rely on the experience of the clinician. The robotic knee testing (RKT) device has been developed to quantitatively and objectively measure rotational knee laxity. The purpose of this study was primarily to determine the intra-tester reliability of rotational knee laxity and slack, the amount of rotation occurring between the two turning points of the load deformation curve, measured by the RKT device and investigate the differences between female and male measurements. METHODS: Ninety-one healthy and moderately active volunteers took part in the study, of which twenty-five participated in the reliability study. Tibial rotation was performed using a servomotor to a torque of 6 N m, while measurements of motion in all 6° of freedom were collected. Reliability measurements were collected over 5 days at similar times of the day. Intra-class correlation coefficient (ICC) values and standard error of measurement (SEM) were determined across the load deformation curves. Linear mixed effects modelling was used to further assess the reliability of the measurement of external and internal tibial rotation using features of the curve (internal/external rotational laxity and slack). Measurements of internal/external rotational laxity and slack were compared between the sexes using the Student t test. RESULTS: Pointwise axial rotation measurements of the tibia had good reliability [ICC (2,1) 0.83-0.89], while reliability of the secondary motions ranged between poor and good [ICC (2,1) 0.31-0.89]. All SEMs were less than 0.3°. Most of the variation of the curve features were accounted for by inter-subject differences (56.2-77.8%) and showed moderate to good reliability. Comparison of the right legs of the sexes revealed that females had significantly larger amounts of internal rotation laxity (females 6.1 ± 1.3° vs males 5.6 ± 0.9°, p = 0.037), external rotation laxity (females 6.0 ± 1.6° vs males 5.0 ± 1.2°, p = 0.002) and slack (females 19.2 ± 4.2° vs males 16.6 ± 2.9°, p = 0.003). Similar results were seen within the left legs. CONCLUSIONS: Overall, the RKT is a reliable and precise tool to assess the rotational laxity of the knee joint in healthy individuals. Finally, greater amounts of laxity and slack were also reported for females.

6.
BMC Musculoskelet Disord ; 18(1): 463, 2017 Nov 17.
Article in English | MEDLINE | ID: mdl-29149846

ABSTRACT

BACKGROUND: The presence of a positive pivot shift after surgical repair of the ACL is considered an important indicator of a failed reconstruction. The ability to predict the result of a pivot shift test after an ACL reconstruction using variables that can be measured prior to surgery could provide an indication of which patients may be at-risk of a poor surgical outcome.The purpose of this study was to determine whether structural characteristics of the femur and tibia, measured using plain radiographs, were associated with the result of the pivot shift test in unilateral ACL reconstructed patients. METHODS: Sixteen patients who had undergone unilateral ACL reconstruction were divided into two groups based on the results of manual pivot shift testing: 1) Pivot group; and 2) No pivot group. All patients had standing true lateral radiographs of both knees. Structural measurements of the tibia and femur were made on both knees. In addition, two new variables were created to describe the tibiofemoral mismatch: 1) Femur Tibia Size Ratio (FTSR); and 2) Tibia to Posterior Femoral Condyle Ratio (TPFCR). These measures were compared within groups and between groups. RESULTS: None of the individual structural characteristics were significantly different when compared between groups. No individual structural characteristics had a significant association with the presence of a positive pivot shift. When a between-group analysis was performed, both the FTSR (p < 0.03) and the TPFCR (p < 0.01) were significantly different between the Pivot group and the No Pivot group. A larger FTSR ratio, or a larger femur relative to the tibia, was associated with a positive pivot shift. A smaller TPFCR ratio, or a smaller tibial depth relative to the depth of the lateral posterior femoral condyle, was associated with a positive pivot shift. CONCLUSIONS: Structural characteristics in the lateral femoral condyle and lateral tibial plateau were found to be associated with the presence of a positive pivot shift. These characteristics could separate between patients in the Pivot group and the No Pivot group. Two indices, the FTSR and the TPFCR, provided better predictive value than individual characteristics in identifying patients with a knee that was structurally "at-risk" for developing a positive pivot shift.


Subject(s)
Anterior Cruciate Ligament Injuries/surgery , Anterior Cruciate Ligament Reconstruction/adverse effects , Joint Instability/diagnostic imaging , Knee Joint/physiology , Adult , Anterior Cruciate Ligament/physiology , Anterior Cruciate Ligament/surgery , Cohort Studies , Female , Femur/anatomy & histology , Femur/diagnostic imaging , Humans , Joint Instability/etiology , Knee Joint/diagnostic imaging , Male , Middle Aged , Patient Selection , Predictive Value of Tests , Radiography , Range of Motion, Articular , Risk Assessment/methods , Rotation , Tibia/anatomy & histology , Tibia/diagnostic imaging , Treatment Failure
7.
Knee Surg Sports Traumatol Arthrosc ; 25(4): 1038-1047, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28299388

ABSTRACT

PURPOSE: The purpose of this study was to identify biomechanical factors, in both reconstructed and healthy knees, that correlate with patient satisfaction after ACL reconstruction. METHODS: Seventeen patients who had undergone unilateral ACL reconstruction were reviewed 9 years post-op. Patients completed subjective questionnaires and underwent manual knee laxity testing (Lachman-Trillat, KT-1000, and pivot shift) and automated laxity testing. During automated testing, both legs were rotated into external rotation and then internal rotation until peak rotational torque reached 5.65 Nm. Load-deformation curves were generated from torque and rotation data. Features of the curves were extracted for analysis. Total leg rotation and anterior laxity during KT-1000 testing were combined into a single factor (Joint Play Envelope or JPE). Patients were divided into groups based on patient satisfaction scores (Group 1: Higher Satisfaction, Group 2: Lower Satisfaction, Group 3: Unsatisfied). Load-deformation curve features and manual laxity testing results were compared between groups 1 and 2 to determine which biomechanical factors could distinguish between the groups. Diagnostic screening values were calculated for KT-1000 testing, the pivot shift test, total leg rotation and JPE. RESULTS: During manual testing, no significant differences in biomechanical factors were found when comparing reconstructed knees in group 1 and group 2. When comparing the reconstructed and healthy knees within group 2, the reconstructed knees had a significantly higher displacement during the KT-1000 manual maximum test (p < 0.002). When considering the reconstructed knees alone, neither the result of the pivot shift test nor KT-1000 testing could distinguish between group 1 and group 2. During automated testing, there were no significant differences between the groups when comparing the reconstructed lower limbs. The healthy lower limbs in group 2 had more maximum external rotation (p < 0.02) and decreased stiffness at maximum external rotation (p < 0.02) when compared to the healthy lower limbs in group 1. Total leg rotation was unable to distinguish between group 1 and group 2. JPE could distinguish between group 1 and group 2 when considering the reconstructed limb alone (p < 0.02). All four diagnostic screening values for JPE were equal or higher than in the other criteria. JPE also showed the most significant correlation with patient satisfaction. CONCLUSIONS: Joint Play Envelope is an objective measure that demonstrated improved predictive value as compared to other tests when used as a measure of satisfaction in patients with ACL reconstructed knees.


Subject(s)
Anterior Cruciate Ligament Reconstruction , Patient Satisfaction , Female , Follow-Up Studies , Humans , Joint Instability/physiopathology , Joint Instability/psychology , Knee Joint/physiopathology , Male , Retrospective Studies , Rotation
8.
Knee Surg Sports Traumatol Arthrosc ; 25(4): 1161-1169, 2017 Apr.
Article in English | MEDLINE | ID: mdl-28314890

ABSTRACT

PURPOSE: The purpose of this study was to evaluate the separate contribution of the two definitions of the anterolateral ligament (ALL), the mid-third lateral capsular ligament (MTLCL) and deep capsule-osseous layer of the iliotibial tract (dcITT) in addition to the superficial iliotibial tract (sITT) to the control of tibial motion with respect to the femur during the application of force/torque seen during the three tests of the standard clinical knee examination (AP Lachman test, tibial axial rotation test and varus-valgus stress test). METHODS: Six pelvis-to-toe cadaveric specimens were examined using an automated testing device that carried out the three components of the clinical knee examination. Internal/external rotation torque, anteroposterior load and adduction/abduction torque were applied, while torque/force and positional measurements were recorded. Sequential sectioning of the structures followed the same order for each knee, sITT, dcITT and MTLCL. Testing was repeated after release of each structure. RESULTS: During the tibial axial rotation test, releasing the sITT caused an increase in internal rotation of 2.6° (1.4-4.1°, p < 0.0005), while release of the dcITT increased internal rotation an additional 0.8° (0.4-1.1°, p < 0.0015). Changes in secondary motions of the tibia after sITT release demonstrated an increase in anterior translation of 1.2 mm (0.6-2.0 mm, p < 0.0005) during internal rotation, while release of the dcITT increased the same motion an additional 0.4 mm (0.2-0.5 mm, p < 0.0005). During the AP Lachman test, release of the sITT caused the tibia to move more anteriorly by 0.7 mm (0.4-1.1 mm, p < 0.0005) and increased internal rotation by 2.7° (0.9-5.2°, p < 0.004). The additional release of the dcITT resulted in more anterior translation by 0.3 mm (0.1-0.4 mm, p < 0.002) and internal rotation by 0.9° (0.2-1.7°, p < 0.005). During the varus-valgus stress test, release of the sITT permitted 0.9° (0.4-1.4°, p < 0.0005) more adduction of the tibia, while the additional release of the dcITT significantly increased adduction by 0.4° (0.2°-0.5°, p < 0.001). Release of the MTLCL had a nominal but significant increase in internal rotation, 0.6° (0.1-1.1°, p < 0.0068) and external rotation, -0.1° (-0.1° to -0.2°, p < 0.0025) during the tibial axial rotation test, anterior translation of 0.2 mm (0.0-0.4 mm, p < 0.021) only during the AP Lachman test, and adduction rotation, 0.2° (0.0-0.3°, p < 0.034) only during the varus-valgus stress test. CONCLUSION: The presence of increased adduction during an automated knee examination provides unique information identifying the release of the sITT, dcITT and the MTLCL in this cadaveric study. While their sequential release caused similar pattern changes in the three components of the automated knee examination, the extent of change due to release of the MTLCL was markedly less than after release of the dcITT which was markedly less than after release of the sITT.


Subject(s)
Fasciotomy , Knee Joint/physiology , Ligaments, Articular/surgery , Physical Examination/methods , Adult , Aged , Cadaver , Humans , Middle Aged , Range of Motion, Articular/physiology , Rotation , Torque
9.
Knee Surg Sports Traumatol Arthrosc ; 24(3): 796-806, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26860289

ABSTRACT

PURPOSE: To analyse the clinical, rotational and radiological (MRI) results of paediatric anatomical "C-shaped" double-bundle (DB) anterior cruciate ligament (ACL) reconstruction with anteromedial and posteromedial bundle compared to single-bundle (SB) ACL reconstruction. METHODS: Between 2008 and 2014, 57 consecutive patients received a paediatric ACL reconstruction with open physis and were allocated into two groups, according to the surgical procedure. Transepiphyseal SB technique was used until 2012 and DB consecutively thereafter. Follow-up consisted of a clinical evaluation with assessment of the International Knee Documentation Committee (IKDC) form, the Lysholm knee score, Tegner activity score, KT-1000 arthrometer evaluation, VAS Scores for satisfaction, MRI and testing of rotational stability using a robotic system. RESULTS: The mean time from ACL reconstruction to follow-up was 48.1 ± 15.8 in the SB group (n = 17) and 23.1 ± 13.2 in the DB group (n = 16; p < 0.001). No differences were found in the subjective scores. Biomechanically, there were significant differences identified in the KT-1000 (p < 0.03) and total tibial axial rotation (p < 0.04) when evaluating the reconstructed knee only. Ten of 17 (59%) of the SB patients had a Joint Play Area within the acceptable range of the median healthy knee value compared to 100 % in the DB group. Decreased patient satisfaction was associated with increased total tibial axial rotation. No growth disturbance was observed. Overall, 98% of patients were reached and either examined or interviewed. Re-rupture rate was 3 of 21 (14.3%) for DB and 9 of 35 (25.7%) for SB. All but one re-ruptures (92%) happened in the first 16 postoperative months independent of technique. CONCLUSIONS: The re-rupture rate after pre-adolescent ACL reconstruction is too high both historically and in this mixed cohort. Anatomical transepiphyseal DB ACL reconstruction with open physis may result in a reduction in this re-rupture rate, which may be related to a tighter control of the Joint Play Area. While subjective clinical results were similar between SB and DB, decreased patient satisfaction was associated with increased total tibial axial rotation in the entire cohort. Despite the need for two transepiphyseal tunnels in the DB technique, there did not appear to be an increased risk in growth plate disturbance. Transepiphyseal DB ACL reconstruction appears to be a reasonable alternative to current techniques in pre-adolescent children with an ACL rupture. LEVEL OF EVIDENCE: IV.


Subject(s)
Anterior Cruciate Ligament Reconstruction/methods , Tendons/transplantation , Adolescent , Anterior Cruciate Ligament/surgery , Anterior Cruciate Ligament Injuries , Female , Follow-Up Studies , Humans , Lysholm Knee Score , Male , Patient Satisfaction , Recurrence
10.
Knee Surg Sports Traumatol Arthrosc ; 23(10): 2892-9, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26359177

ABSTRACT

PURPOSE: The purpose of this study was to determine the test-retest reliability and the repeatability over multiple days of a robotic testing device when used to measure laxity of the lower leg during a simulated dial test. METHODS: Ten healthy subjects were evaluated using an instrumented robotic lower leg testing system over 4 days. Three testing cycles were performed each day. Each leg was rotated into external and then internal rotation by servomotors until a torque threshold of 5.65 N m was reached. Load-deformation curves were generated from torque and rotation data. Both average-measure and single-measure intraclass correlation coefficients (ICC) were compared across the curves. ICC scores were also compared for features of the curves including: maximum external rotation at -5.65 N m of torque, maximum internal rotation at 5.65 N m of torque, rotation at torque 0, compliance (slope of load-deformation curve) at torque 0, endpoint compliance in external rotation, endpoint compliance in internal rotation, and play at torque 0. Play at torque 0 was defined as the width of the hysteresis curve at torque 0. RESULTS: Average-measure ICC scores and test-retest scores were >0.95 along the entire load-deformation curve except around zero torque. ICC scores at maximum internal and external rotation ranged from 0.87 to 0.99 across the left and right knees. ICC scores for the other features of the curves ranged from 0.61 to 0.98. The standard error of the mean ranged from 0.0497 to 1.1712. CONCLUSIONS: The robotic testing device in this study proved to be reliable for testing a subject multiple times both within the same day and over multiple days. These findings suggest that the device can provide a level of reliability in rotational testing that allows for clinical use of test results. Objective laxity data can improve consistency and accuracy in diagnosing knee injuries and may enable more effective treatment.


Subject(s)
Arthrometry, Articular/instrumentation , Joint Instability/diagnosis , Knee Joint/physiopathology , Robotics , Adult , Female , Humans , Joint Instability/physiopathology , Male , Reproducibility of Results , Rotation
11.
Knee Surg Sports Traumatol Arthrosc ; 23(10): 2882-91, 2015 Oct.
Article in English | MEDLINE | ID: mdl-26337279

ABSTRACT

PURPOSE: The purpose of this study was to compare the biomechanical characteristics and patient outcomes after either isolated intraarticular ACL reconstruction or intraarticular reconstruction with lateral extra-articular tenodesis. In addition, we aimed to evaluate biomechanical parameters of the entire uninjured, contralateral knee as a baseline during the analysis. METHODS: Eighteen patients were evaluated at an average of 9.3 years after ACL reconstruction. Twelve patients had an intraarticular reconstruction (BTB), and six had an additional lateral extraarticular procedure (BTB/EAR). Patients were selected for the additional procedure by the operating surgeon based on clinical and radiological criteria. At the time of review, each patient was assessed using subjective patient questionnaires, manual laxity testing, and instrumented laxity testing. Each knee was also evaluated using a robotic lower leg axial rotation testing system. This system measured maximum internal and external rotations at 5.65 Nm of applied torque and generated load deformation curves and compliance data. Pointwise statistical comparisons within each group and between groups were performed using the appropriate paired or unpaired t test. Features were extracted from each load deformation curve for comparative analysis. RESULTS: There were no significant differences between the two groups with respect to the patient satisfaction scores or to laxity testing (manual or instrumented). Robotic testing results for within-group comparisons demonstrated a significant reduction in maximum external rotation (8.77°) in the reconstructed leg when compared to the healthy leg (p < 0.05) in the BTB/EAR group, with a non-significant change in internal rotation. The slope of the curve at maximum internal rotation was also significantly greater in the reconstructed legs for the BTB/EAR group (p < 0.05), indicating reduced endpoint compliance or a harder endpoint. Finally, the leg that received the extra-articular tenodesis had a trend towards a reduced total leg axial rotation. Conversely, patients in the BTB group demonstrated no significant differences between their legs. For between-group comparisons, there was a significant increase in maximum internal rotation in the healthy legs in the BTB/EAR group compared with the healthy legs in the BTB group (p < 0.05). If the injured/reconstructed legs were compared, the significant difference at maximum internal rotation disappeared (p < 0.10). Similarly, the healthy legs in patients in the BTB/EAR group had a significantly more compliant or softer endpoint in internal rotation, greater maximum internal rotation, and more internal rotation at torque 0 in their healthy legs compared with the healthy legs in the BTB group (p < 0.05). These same differences were not noted in the reconstructed knees. The only identifiable significant difference between the injured/reconstructed legs was rotation at 0 torque (p < 0.05). CONCLUSIONS: In this group of patients who were at an average of 9 years from surgery, the addition of a lateral extra-articular reconstruction to a standard bone-tendon-bone intraarticular ACL reconstruction does reduces internal rotation of the tibia with respect to the femur when compared to intraarticular reconstruction alone. It appears that the selection process for inclusion into the BTB/EAR group included an increase in total axial rotation of the healthy knee during the examination along with a decrease in endpoint stiffness at maximum internal rotation. LEVEL OF EVIDENCE: II.


Subject(s)
Anterior Cruciate Ligament Reconstruction/methods , Anterior Cruciate Ligament/surgery , Arthrometry, Articular/instrumentation , Lower Extremity/physiology , Patient Satisfaction , Robotics , Adult , Female , Follow-Up Studies , Humans , Male , Middle Aged , Rotation
SELECTION OF CITATIONS
SEARCH DETAIL
...