Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Publication year range
1.
Nuklearmedizin ; 49(6): 225-33; quiz N60-1, 2010.
Article in German | MEDLINE | ID: mdl-20617279

ABSTRACT

The purpose of these guidelines is to offer the nuclear medicine and the appropriate interdisciplinary team a framework for performing and reporting positron emission tomography (PET) and the combination with computed tomography (PET/CT) in children with malignant diseases mainly using the radiopharmaceutical 18F-fluorodeoxy-glucose (FDG). These guidelines are based on the recent guidelines of the Paediatric Committee of the European Association of Nuclear Medicine (EANM) (57) and have been translated and adapted to the current conditions in Germany. The adaptation of CT-parameters using PET/CT in children is covered in a more detailed way than in the EANM guideline taking into account that in Germany already a good portion of PET examinations is performed using an integrated PET/CT-scanner. Furthermore, a CT-scan without adoption of the CT acquisition parameters would result in a not tolerably high radiation exposition of the child. There are excellent guidelines for FDG PET and PET/CT in oncology published by the German Society of Nuclear Medicine (Deutsche Gesellschaft für Nuklearmedizin, DGN) (42) and EANM (4). These guidelines aim at providing additional information on issues particularly relevant to PET and PET/CT imaging in children. These guidelines should be taken in the context of local and national current standards of quality and rules.


Subject(s)
Fluorodeoxyglucose F18 , Neoplasms/diagnostic imaging , Body Weight , Child , Germany , Humans , Pediatrics/methods , Pediatrics/standards , Positron-Emission Tomography , Practice Guidelines as Topic , Radiopharmaceuticals , Tomography, X-Ray Computed
2.
Acta Radiol ; 44(6): 616-21, 2003 Nov.
Article in English | MEDLINE | ID: mdl-14616206

ABSTRACT

PURPOSE: To assess and quantify the image quality at two dose levels for an amorphous Silicon (a:Si) Cesium Iodide (CsI) flat panel system compared with a direct amorphous Selenium (a:Se) digital radiography system. MATERIAL AND METHODS: A contrast detectability test was performed employing the CDRAD-phantom at mAs-values leading to approximately equal phantom entrance doses of 41.4, 57.9, 75.1 and 120.8 micro Gy for the a:Se and 39.9, 58.4, 75.6 and 117.9 micro Gy for the CsI system. Images were presented to 4 independent observers. For quantitative comparison, the image quality figure (IQF) was calculated. Statistical analysis was performed using Pearson's correlation and the Wilcoxon test. A ROC-analysis was performed employing the TRG-phantom in a high- and a low-dose setting leading to entrance doses of 126.2 and 35 micro Gy for the direct, and 125.9 and 34.4 micro Gy for the indirect system. Statistical significance was evaluated using the Wilcoxon test. RESULTS: The flat panel a:Si digital system provided superior results compared with the a:Se drum digital system with respect to low-dose settings for CDRAD-phantom and ROC-analysis, ensuring a better image quality with respect to contrast and detail detectability. Higher-dose settings provided similar results for both systems. CONCLUSION: Image quality of a:Si flat panel digital radiography proved to be superior to a:Se drum digital radiography using low-dose settings. If the primary target is dose reduction indirect flat panel technology should be used.


Subject(s)
Cesium , Iodides , Radiographic Image Enhancement/methods , Silicon , Phantoms, Imaging , ROC Curve , Radiographic Image Enhancement/instrumentation , Radiography, Thoracic
3.
Pediatr Radiol ; 31(4): 279-82, 2001 Apr.
Article in English | MEDLINE | ID: mdl-11321747

ABSTRACT

We report a 15-year-old boy with patent ductus venosus in whom the diagnosis was made by MR angiography. A patent ductus venosus Arantii is a rare form of portosystemic shunt. Only a few cases have been reported in adults and children. The diagnosis is usually made by US and digital subtraction angiography. In our patient, the diagnosis was first made by MR angiography. This demonstrates the excellent diagnostic potential of the method in paediatric patients.


Subject(s)
Magnetic Resonance Angiography , Portal System/abnormalities , Adolescent , Angiography, Digital Subtraction , Humans , Male , Portal Vein/abnormalities
4.
Pediatr Radiol ; 21(6): 416-20, 1991.
Article in English | MEDLINE | ID: mdl-1749674

ABSTRACT

RARE-MR-urography (Rapid Acquisition with Relaxation Enhancement) is a fast MR imaging technique (6.4 s/acquisition) that selectively depicts fluid by heavy T2-weighting. From 9/1989 to 11/1990, RARE-MR urograms were prospectively evaluated in the diagnosis of upper urinary tract abnormalities in 55 children. The method is performed in several planes and combined with a coronal, T1-weighted spin-echo sequence. Forty out of 42 kidneys with dilated renal pelvis, and 21 out of 24 dilated ureters were identified, only the mildly dilated ones were missed. Even in non-functioning kidneys the urinary tract was clearly depicted by RARE-MR-urography. However, no differentiation could be made with this technique between vesicoureteral reflux and non-refluxing dilatation of ureter and/or renal pelvis. All 19 pelviureteric obstructions and all eight renal duplications with a dilated segment were identified. RARE-MR-urography is a new tool for diagnosing urinary tract abnormalities in children without having to employ ionizing radiation, contrast media, or general anesthesia. A dilated urinary tract can be shown in one image displaying the entire urinary system, similar to excretory urography. The technique is presently not able to provide the information of voiding cystourethrography or renal scintigraphy, nor is it as easy to perform as ultrasound. However, in certain cases it may replace excretory urography.


Subject(s)
Magnetic Resonance Imaging , Urinary Tract/abnormalities , Urologic Diseases/diagnosis , Adolescent , Child , Child, Preschool , Congenital Abnormalities/diagnosis , Female , Humans , Infant , Infant, Newborn , Magnetic Resonance Imaging/methods , Male , Prospective Studies , Urinary Tract/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...