Results 1 - 9 de 9
Filter
1.
Abdom Radiol (NY) ; 46(12): 5772-5780, 2021 12.
Article in English | MEDLINE | ID: mdl-34415411

ABSTRACT

PURPOSE: To develop a protocol for abdominal imaging on a prototype 0.55 T scanner and to benchmark the image quality against conventional 1.5 T exam. METHODS: In this prospective IRB-approved HIPAA-compliant study, 10 healthy volunteers were recruited and imaged. A commercial MRI system was modified to operate at 0.55 T (LF) with two different gradient performance levels. Each subject underwent non-contrast abdominal examinations on the 0.55 T scanner utilizing higher gradients (LF-High), lower adjusted gradients (LF-Adjusted), and a conventional 1.5 T scanner. The following pulse sequences were optimized: fat-saturated T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and Dixon T1-weighted imaging (T1WI). Three readers independently evaluated image quality in a blinded fashion on a 5-point Likert scale, with a score of 1 being non-diagnostic and 5 being excellent. An exact paired sample Wilcoxon signed-rank test was used to compare the image quality. RESULTS: Diagnostic image quality (overall image quality score ≥ 3) was achieved at LF in all subjects for T2WI, DWI, and T1WI with no more than one unit lower score than 1.5 T. The mean difference in overall image quality score was not significantly different between LF-High and LF-Adjusted for T2WI (95% CI - 0.44 to 0.44; p = 0.98), DWI (95% CI - 0.43 to 0.36; p = 0.92), and for T1 in- and out-of-phase imaging (95%C I - 0.36 to 0.27; p = 0.91) or T1 fat-sat (water only) images (95% CI - 0.24 to 0.18; p = 1.0). CONCLUSION: Diagnostic abdominal MRI can be performed on a prototype 0.55 T scanner, either with conventional or with reduced gradient performance, within an acquisition time of 10 min or less.


Subject(s)
Diffusion Magnetic Resonance Imaging , Magnetic Resonance Imaging , Abdomen/diagnostic imaging , Humans , Image Interpretation, Computer-Assisted , Prospective Studies
2.
J Magn Reson Imaging ; 49(2): 411-422, 2019 02.
Article in English | MEDLINE | ID: mdl-30252989

ABSTRACT

BACKGROUND: Computed tomography (CT) and spirometry are the current standard methods for assessing lung anatomy and pulmonary ventilation, respectively. However, CT provides limited ventilation information and spirometry only provides global measures of lung ventilation. Thus, a method that can enable simultaneous examination of lung anatomy and ventilation is of clinical interest. PURPOSE: To develop and test a 4D respiratory-resolved sparse lung MRI (XD-UTE: eXtra-Dimensional Ultrashort TE imaging) approach for simultaneous evaluation of lung anatomy and pulmonary ventilation. STUDY TYPE: Prospective. POPULATION: In all, 23 subjects (11 volunteers and 12 patients, mean age = 63.6 ± 8.4). FIELD STRENGTH/SEQUENCE: 3T MR; a prototype 3D golden-angle radial UTE sequence, a Cartesian breath-hold volumetric-interpolated examination (BH-VIBE) sequence. ASSESSMENT: All subjects were scanned using the 3D golden-angle radial UTE sequence during normal breathing. Ten subjects underwent an additional scan during alternating normal and deep breathing. Respiratory-motion-resolved sparse reconstruction was performed for all the acquired data to generate dynamic normal-breathing or deep-breathing image series. For comparison, BH-VIBE was performed in 12 subjects. Lung images were visually scored by three experienced chest radiologists and were analyzed by two observers who segmented the left and right lung to derive ventilation parameters in comparison with spirometry. STATISTICAL TESTS: Nonparametric paired two-tailed Wilcoxon signed-rank test; intraclass correlation coefficient, Pearson correlation coefficient. RESULTS: XD-UTE achieved significantly improved image quality compared both with Cartesian BH-VIBE and radial reconstruction without motion compensation (P < 0.05). The global ventilation parameters (a sum of the left and right lung measures) were in good correlation with spirometry in the same subjects (correlation coefficient = 0.724). There were excellent correlations between the results obtained by two observers (intraclass correlation coefficient ranged from 0.8855-0.9995). DATA CONCLUSION: Simultaneous evaluation of lung anatomy and ventilation using XD-UTE is demonstrated, which have shown good potential for improved diagnosis and management of patients with heterogeneous lung diseases. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2019;49:411-422.


Subject(s)
Echo-Planar Imaging , Lung/diagnostic imaging , Magnetic Resonance Imaging , Spirometry , Adult , Aged , Artifacts , Breath Holding , Female , Humans , Image Interpretation, Computer-Assisted/methods , Image Processing, Computer-Assisted/methods , Imaging, Three-Dimensional , Lung/pathology , Male , Middle Aged , Motion , Prospective Studies , Respiration , Tomography, X-Ray Computed , Young Adult
3.
J Magn Reson Imaging ; 48(1): 188-197, 2018 07.
Article in English | MEDLINE | ID: mdl-29331053

ABSTRACT

BACKGROUND: Diffusion-weighted imaging (DWI) provides insight into the pathophysiology underlying renal dysfunction. Variants of DWI include intravoxel incoherent motion (IVIM), which differentiates between microstructural diffusion and vascular or tubular flow, and diffusion tensor imaging (DTI), which quantifies diffusion directionality. PURPOSE: To investigate the reproducibility of joint IVIM-DTI and compare controls to presurgical renal mass patients. STUDY TYPE: Prospective cross-sectional. SUBJECTS: Thirteen healthy controls and ten presurgical renal mass patients were scanned. Ten controls were scanned twice to investigate reproducibility. FIELD STRENGTH/SEQUENCE: Subjects were scanned on a 3T system using 10 b-values and 20 diffusion directions for IVIM-DTI in a study approved by the local Institutional Review Board. ASSESSMENT: Retrospective coregistration and measurement of joint IVIM-DTI parameters were performed. STATISTICAL ANALYSIS: Parameter reproducibility was defined as intraclass correlation coefficient (ICC) >0.7 and coefficient of variation (CV) <30%. Patient data were stratified by lesion side (contralateral/ipsilateral) for comparison with controls. Corticomedullary differentiation was evaluated. RESULTS: In controls, the reproducible subset of REnal Flow and Microstructure AnisotroPy (REFMAP) parameters had average ICC = 0.82 and CV = 7.5%. In renal mass patients, medullary fractional anisotropy (FA) was significantly lower than in controls (0.227 ± 0.072 vs. 0.291 ± 0.044, P = 0.016 for the kidney contralateral to the mass and 0.228 ± 0.070 vs. 0.291 ± 0.044, P = 0.018 for the kidney ipsilateral). In the kidney ipsilateral to the mass, cortical Dp,radial was significantly higher than in controls (P = 0.012). Conversely, medullary Dp,axial was significantly lower in contralateral than ipsilateral kidneys (P = 0.027) and normal controls (P = 0.044). DATA CONCLUSION: REFMAP-MRI parameters provide unique information regarding renal dysfunction. In presurgical renal mass patients, directional flow changes were noted that were not identified with IVIM analysis alone. Both contralateral and ipsilateral kidneys in patients show reductions in structural diffusivities and anisotropy, while flow metrics showed opposing changes in contralateral vs. ipsilateral kidneys. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018.


Subject(s)
Diffusion Magnetic Resonance Imaging , Kidney Neoplasms/diagnostic imaging , Kidney/diagnostic imaging , Adult , Aged , Aged, 80 and over , Anisotropy , Body Mass Index , Cross-Sectional Studies , Diffusion Tensor Imaging , Female , Humans , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Image Processing, Computer-Assisted , Male , Middle Aged , Motion , Normal Distribution , Preoperative Period , Prospective Studies , Reproducibility of Results , Retrospective Studies
4.
Invest Radiol ; 50(3): 144-52, 2015 Mar.
Article in English | MEDLINE | ID: mdl-25387050

ABSTRACT

OBJECTIVES: The aim of this study was to determine if voxel-based histogram analysis of intravoxel incoherent motion imaging (IVIM) parameters can differentiate various subtypes of renal tumors, including benign and malignant lesions. SUBJECTS AND METHODS: A total of 44 patients with renal tumors who underwent surgery and had histopathology available were included in this Health Insurance Portability and Accountability Act-compliant, institutional review board-approved, single-institution prospective study. In addition to routine renal magnetic resonance imaging examination performed on a 1.5-T system, all patients were imaged with axial diffusion-weighted imaging using 8 b values (range, 0-800 s/mm). A biexponential model was fitted to the diffusion signal data using a segmented algorithm to extract the IVIM parameters perfusion fraction (fp), tissue diffusivity (Dt), and pseudodiffusivity (Dp) for each voxel. Mean and histogram measures of heterogeneity (standard deviation, skewness, and kurtosis) of IVIM parameters were correlated with pathology results of tumor subtype using unequal variance t tests to compare subtypes in terms of each measure. Correction for multiple comparisons was accomplished using the Tukey honestly significant difference procedure. RESULTS: A total of 44 renal tumors including 23 clear cell (ccRCC), 4 papillary (pRCC), 5 chromophobe, and 5 cystic renal cell carcinomas, as well as benign lesions, 4 oncocytomas (Onc) and 3 angiomyolipomas (AMLs), were included in our analysis. Mean IVIM parameters fp and Dt differentiated 8 of 15 pairs of renal tumors. Histogram analysis of IVIM parameters differentiated 9 of 15 subtype pairs. One subtype pair (ccRCC vs pRCC) was differentiated by mean analysis but not by histogram analysis. However, 2 other subtype pairs (AML vs Onc and ccRCC vs Onc) were differentiated by histogram distribution parameters exclusively. The standard deviation of Dt [σ(Dt)] differentiated ccRCC (0.362 ± 0.136 × 10 mm/s) from AML (0.199 ± 0.043 × 10 mm/s) (P = 0.002). Kurtosis of fp separated Onc (2.767 ± 1.299) from AML (-0.325 ± 0.279; P = 0.001), ccRCC (0.612 ± 1.139; P = 0.042), and pRCC (0.308 ± 0.730; P = 0.025). CONCLUSIONS: Intravoxel incoherent motion imaging parameters with inclusion of histogram measures of heterogeneity can help differentiate malignant from benign lesions as well as various subtypes of renal cancers.


Subject(s)
Diffusion Magnetic Resonance Imaging/methods , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Kidney Neoplasms/classification , Kidney Neoplasms/pathology , Pattern Recognition, Automated/methods , Adult , Aged , Aged, 80 and over , Algorithms , Data Interpretation, Statistical , Diagnosis, Differential , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Motion , Numerical Analysis, Computer-Assisted , Reproducibility of Results , Sensitivity and Specificity
5.
Radiology ; 267(1): 293-304, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23297320

ABSTRACT

PURPOSE: To evaluate diagnostic performance of three nonenhanced methods: variable-refocusing-flip angle (FA) fast spin-echo (SE)-based magnetic resonance (MR) angiography (variable FA MR) and constant-refocusing-FA fast SE-based MR angiography (constant-FA MR) and flow-sensitive dephasing (FSD)-prepared steady-state free precession MR angiography (FSD MR) for calf arteries, with dual-injection three-station contrast material-enhanced MR angiography (gadolinium-enhanced MR) as reference. MATERIALS AND METHODS: This prospective study was institutional review board approved and HIPAA compliant, with informed consent. Twenty-one patients (13 men, eight women; mean age, 62.6 years) underwent calf-station variable-FA MR, constant-FA MR, and FSD MR at 1.5 T, with gadolinium-enhanced MR as reference. Image quality and stenosis severity were assessed in 13 segments per leg by two radiologists blinded to clinical data. Combined constant-FA MR and FSD MR reading was also performed. Methods were compared (logistic regression for correlated data) for diagnostic accuracy. RESULTS: Of 546 arterial segments, 148 (27.1%) had a hemodynamically significant (≥ 50%) stenosis. Image quality was satisfactory for all nonenhanced MR sequences. FSD MR was significantly superior to both other sequences (P < .0001), with 5-cm smaller field of view; 9.6% variable-FA MR, 9.6% constant-FA MR, and 0% FSD MR segmental evaluations had nondiagnostic image quality scores, mainly from high diastolic flow (variable-FA MR) and motion artifact (constant-FA MR). Stenosis sensitivity and specificity were highest for FSD MR (80.3% and 81.7%, respectively), compared with those for constant-FA MR (72.3%, P = .086; and 81.8%, P = .96) and variable-FA MR (75.9%, P = .54; and 75.6%, P = .22). Combined constant-FA MR and FSD MR had superior sensitivity (81.8%) and specificity (88.3%) compared with constant-FA MR (P = .0076), variable-FA MR (P = .0044), and FSD MR (P = .0013). All sequences had an excellent negative predictive value (NPV): 93.2%, constant-FA MR; 94.7%, variable-FA MR; 91.7%, FSD MR; and 92.9%, combined constant-FA MR and FSD MR. CONCLUSION: At 1.5 T, all evaluated nonenhanced MR angiographic methods demonstrated satisfactory image quality and excellent NPV for hemodynamically significant stenosis. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120859/-/DC1.


Subject(s)
Leg/blood supply , Magnetic Resonance Angiography/methods , Peripheral Vascular Diseases/diagnosis , Adult , Aged , Aged, 80 and over , Contrast Media , Female , Gadolinium DTPA , Humans , Logistic Models , Male , Middle Aged , Prospective Studies , Sensitivity and Specificity , Subtraction Technique
6.
Invest Radiol ; 47(12): 717-24, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23070094

ABSTRACT

OBJECTIVE: The purpose of this study was to monitor iron clearance from the liver by means of T2 and T2* mapping after administration of an ultrasmall superparamagnetic iron oxide (USPIO) agent. MATERIALS AND METHODS: The study was performed using ferumoxytol (Feraheme), a USPIO agent that has been approved by the US Food and Drug Administration for the treatment of iron deficiency anemia in adult patients with chronic kidney disease. Six healthy human participants without anemia or preexisting iron overload were prospectively included. The cohort comprised 4 men and 2 postmenopausal women, aged 22 to 57 years. T2 and T2* mapping of the liver were performed at 1.5 T using multiple spin echo and multiple gradient echo sequences, respectively. After baseline imaging, ferumoxytol was injected intravenously at a dose of 5 mg Fe/kg body weight. Imaging was repeated at 3 days, 1 month, and every 2 months thereafter for up to 11 months or until liver T2* had recovered to 24 milliseconds, the threshold used to define iron deposition. For each examination, maps of the relaxation rates R2 (= 1/T2) and R2* (= 1/T2*) were generated by fitting the signal intensity data as a function of echo time to a monoexponential decay. RESULTS: No adverse reactions to ferumoxytol injection occurred. The magnetic resonance (MR) responses to ferumoxytol varied widely among the participants. Liver R2* increased from a mean value of 35.6 s (range, 28.7-40.9 s) at baseline to a mean value of 241 s (range, 161-417 s) 3 days after administration. Liver R2 increased from 19.4 s (range, 16.6-23.8 s) at baseline to 45.3 s (range, 34.4-58.5 s) at 3 days. There was also a large variation in iron clearance times. In 1 participant, MR relaxation rates had recovered to baseline by 3 months, whereas, in 3 participants, liver R2* remained elevated at 11 months (R2* > 55 s, ie, T2* < 18 milliseconds). In these 3 participants, liver R2 also remained marginally higher at 11 months than corresponding baseline values. CONCLUSIONS: Iron deposition in the liver after a 5 mg Fe/kg dose of ferumoxytol may alter signal contrast on MR images for several months after administration. This is an important consideration in the use of USPIO agents for diagnostic purposes.


Subject(s)
Contrast Media , Dextrans , Iron/pharmacokinetics , Liver/metabolism , Magnetic Resonance Imaging , Magnetite Nanoparticles , Adult , Female , Humans , Male , Metabolic Clearance Rate , Middle Aged , Prospective Studies , Young Adult
7.
J Magn Reson Imaging ; 34(6): 1472-9, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21959828

ABSTRACT

PURPOSE: To investigate arterial flow characteristics in the setting of vascular disease, and examine their effect on the performance of fast spin-echo (FSE)-based noncontrast MR angiography (NC-MRA). MATERIALS AND METHODS: Seventeen patients were recruited from among those scheduled for routine contrast-enhanced MR angiography (CE-MRA) of the lower extremities at 1.5 Tesla. The research portion of the exam was performed before the clinically-indicated protocol and included phase-contrast imaging at multiple levels in the legs and FSE-based NC-MRA in the calf and thigh, using a three-dimensional ECG-gated technique that exploits differences in arterial flow velocity between diastole and systole. RESULTS: Vascular occlusions were associated with reduced systolic velocity, a delayed systolic peak, and, in two middle-aged patients, an increase in diastolic velocity. Elevated systolic and diastolic velocities were observed in a subject with a nonhealing ulcer. NC-MRA allowed visualization of arteries with systolic velocities as low as 3 cm/s, and exhibited comparable depiction to CE-MRA for diastolic velocities as high as 6 cm/s. At the highest diastolic velocities observed (15 cm/s) arterial depiction was severely degraded. CONCLUSION: FSE-based NC-MRA as presently implemented performs successfully over a wide range of flow patterns, but does not accommodate extremely low systolic velocities or very high diastolic velocities.


Subject(s)
Arteries/physiopathology , Magnetic Resonance Angiography/methods , Vascular Diseases/physiopathology , Adult , Aged , Aged, 80 and over , Arteries/pathology , Blood Flow Velocity , Diastole , Female , Humans , Male , Middle Aged , Systole
8.
Radiology ; 260(3): 781-9, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21771953

ABSTRACT

PURPOSE: To assess prospectively the ability of quantitative low-dose three-dimensional magnetic resonance (MR) renography to help identify the cause of acute graft dysfunction. MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board, and written informed consent was obtained. Between December 2001 and May 2009, sixty patients with transplanted kidneys (41 men and 19 women; mean age, 49 years; age range, 22-71 years) were included. Thirty-one patients had normal function and 29 had acute dysfunction due to acute rejection (n = 12), acute tubular necrosis (ATN) (n = 8), chronic rejection (n = 6), or drug toxicity (n = 3). MR renography was performed at 1.5 T with three-dimensional gradient-echo imaging. With use of a multicompartment renal model, the glomerular filtration rate (GFR) and the mean transit time (MTT) of the tracer for the vascular compartment (MTT(A)), the tubular compartment (MTT(T)), and the collecting system compartment (MTT(C)) were calculated. Also derived was MTT for the whole kidney (MTT(K) = MTT(A) + MTT(T) + MTT(C)) and fractional MTT of each compartment (MTT(A/K) = MTT(A)/MTT(K), MTT(T/K) = MTT(T)/MTT(K), MTT(C/K) = MTT(C)/MTT(K)). These parameters were compared in patients in the different study groups. Statistical analysis was performed by using analysis of covariance. RESULTS: There were significant differences in GFR and MTT(K) between the acute dysfunction group (36.4 mL/min ± 20.8 [standard deviation] and 177.1 seconds ± 46.8, respectively) and the normal function group (65.9 mL/min ± 27.6 and 140.5 seconds ± 51.8, respectively) (P < .001 and P = .004). The MTT(A/K) was significantly higher in the acute rejection group (mean, 12.7% ± 2.9) than in the normal function group (mean, 8.3% ± 2.2; P < .001) or in the ATN group (mean, 7.1% ± 1.4; P < .001). The MTT(T/K) was significantly higher in the ATN group (mean, 83.2% ± 9.2) than in the normal function group (mean, 72.4% ± 10.2; P = .031) or in the acute rejection group (mean, 69.2% ± 6.1; P = .003). CONCLUSION: Low-dose MR renography analyzed by using a multicompartmental tracer kinetic renal model may help to differentiate noninvasively between acute rejection and ATN after kidney transplantation.


Subject(s)
Acute Kidney Injury/etiology , Acute Kidney Injury/pathology , Imaging, Three-Dimensional/methods , Kidney Transplantation/adverse effects , Kidney Transplantation/pathology , Magnetic Resonance Imaging/methods , Radioisotope Renography/methods , Adult , Aged , Humans , In Vitro Techniques , Middle Aged , Radiation Dosage , Reproducibility of Results , Sensitivity and Specificity , Treatment Failure , Young Adult
9.
Radiology ; 252(3): 874-81, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19567653

ABSTRACT

After institutional review board approval and informed consent were obtained for this HIPAA-compliant investigation, a three-dimensional electrocardiographically gated variable flip angle (VFA) fast spin-echo magnetic resonance (MR) angiography technique was evaluated as an unenhanced method for imaging hand arteries in 13 subjects (including four patients) at 3.0 T; this included evaluation of vessel visualization with warming and cooling in seven subjects. Examinations were evaluated for image quality and vessel conspicuity. Clear separation of arteries from veins was achieved in all subjects, with excellent vessel conspicuity and depiction of stenoses. Warming improved vessel visualization in healthy volunteers. VFA MR angiography is a high-spatial-resolution technique that enables the assessment of vascular reactivity in response to temperature challenge.


Subject(s)
Electrocardiography , Hand/blood supply , Imaging, Three-Dimensional , Magnetic Resonance Angiography/methods , Adult , Aged , Blood Flow Velocity , Cold Temperature , Female , Heart Rate/physiology , Hot Temperature , Humans , Image Processing, Computer-Assisted , Logistic Models , Male , Middle Aged , Prospective Studies , Raynaud Disease/physiopathology , Scleroderma, Limited/physiopathology