Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
World J Nucl Med ; 22(4): 261-266, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38152100

ABSTRACT

Introduction Sentinel lymph node (SLN) mapping is an alternative method to conventional lymphadenectomy for nodal status assessment in patients with stage I/II endometrial carcinoma (EC). This study aimed to analyze the potential predictors of unsuccessful bilateral detection of SLN after the application of radiocolloid in EC. Materials and Methods A prospective, observational, cross-sectional study was performed on 41 patients with EC in preoperative stage I, who underwent SLN mapping after cervical application of 4mCi 99m Tc-SENTI-SCINT. The demographic, clinical, and tumor-related data were obtained from the patient's medical records. Univariate analysis was used to analyze the potential factors associated with an unsuccessful bilateral SLN biopsy. Results The bilateral SLN detection rate of planar lymphoscintigraphy, single photon emission computed tomography/computed tomography, and gamma probe was 29.26, 41.46, and 26.82%, correspondingly. None of the 16 analyzed risk factors showed statistical significance for nonconclusive bilateral SLN biopsy. Conclusion Larger scale studies are needed to determine the exact risk factors for unsuccessful bilateral mapping of the lymphatic drainage after cervical application of the radiotracers. This will eventually lead to improvement in bilateral SLN detection in EC patients, so unilateral lymphadenectomy could be avoided.

2.
Mol Imaging Radionucl Ther ; 32(2): 103-111, 2023 Jun 20.
Article in English | MEDLINE | ID: mdl-37337763

ABSTRACT

Objectives: Detection of a sentinel lymph node (SLN) in patients with endometrial cancer (EC) reduces the rate of unnecessary systemic lymph dissection. The aim of this study was to assess the SLN detection rate, accuracy of the method using Tc-99m-SENTI-SCINT and the rate of metastatic nodal involvement in patients with preoperative first stage EC. Methods: A prospective study of SLN biopsy of 41 patients with stage I EC was conducted after cervical application of 4mCi Tc-99m-SENTI-SCINT. Planar lymphoscintigraphy and single-photon emission computed tomography/computed tomography (SPECT/CT) of the pelvis were performed, followed by site-specific lymphadenectomy in intermediate-risk patients if no SLN was detected per hemipelvis and pelvic lymphadenectomy in all high-risk patients. Results: Pre-operative detection rate of planar lymphoscintigraphy was 80.49 [95% confidence interval (CI): 68.36-92.62] and of SPECT/CT 95.12 (95% CI: 88.52-101.7). The total intraoperative SLN detection rate was 95.12 (95% CI: 88.52-101.7) per patient and 26.83 (95% CI: 19.91-33.75) bilaterally. The average number of SLNs removed was 1.6±0.8. The most common anatomical location of SLN was the right external iliac region. The SLN metastatic rate was 17%. Both sensitivity and negative predictive value regarding metastatic involvement were 100%. Conclusion: The SLN detection rate, sensitivity and negative predictive value using Tc-99m-SENTI-SCINT in patients with EC in our study were high. The application of ultra-staging in the histopathological analysis of SLN increases the detection of nodal metastases and improves the staging in these patients.

3.
Nucl Med Rev Cent East Eur ; 25(2): 101-104, 2022.
Article in English | MEDLINE | ID: mdl-35929122

ABSTRACT

BACKGROUND: Sentinel lymph node (SLN) mapping allows minimal invasive assessment of lymph node status in patients with early-stage endometrial cancer (EC). Intraoperative detection of SLNs is based on the results obtained from preoperative nuclear medical images. The purpose of this study was to compare the data obtained from planar lymphoscintigraphy (PL), single-photon emission computed tomography (SPECT), and SPECT with computed tomography (SPECT/CT) for preoperative SLN detection in patients with EC. MATERIAL AND METHODS: A total of 44 images in 22 patients with early-stage EC (22 PL, 9 SPECT and 13 SPECT/CT) were analyzed. The scans were performed in the period 2018-2020 at the Institute of Pathophysiology and Nuclear Medicine in Skopje. Thirteen patients underwent PL and SPECT/CT and nine patients underwent PL and SPECT after cervical injection of 4 mCi 99mTc-SENTI-SCINT on the day of surgery. Descriptive statistics, Wilcoxon Matched Pairs Test, and Spearman rank R coefficient were used for data analyses. RESULTS: Twenty-two patients with mean age of 61.1 ± 7.5 and body mass index (BMI) 34.62 ± 6.4 kg/m2 were included in the study. In four patients (18.2%) SLN was not detected on PL. Detection rate on SPECT and SPECT/CT was 100%. The average number of detected SLN was 1.4 ± 1.05, 2.2 ± 1.1 и 2.15 ± 1.1 on PL, SPECT and SPECT/CT respectively. We found a statistically significant difference in the number of detected SLNs on PL vs SPECT/CT (p = 0.0077). The most common SLN location on SPECT/CT was the right internal iliac followed by the left common iliac region. CONCLUSIONS: The results of the presented study indicate a higher diagnostic value of SPECT/CT in terms of SLN detection and exact anatomic localization as compared to planar lymphoscintigraphy (PL).


Subject(s)
Endometrial Neoplasms , Sentinel Lymph Node , Aged , Endometrial Neoplasms/diagnostic imaging , Endometrial Neoplasms/pathology , Endometrial Neoplasms/surgery , Female , Humans , Lymphoscintigraphy/methods , Middle Aged , Sentinel Lymph Node/diagnostic imaging , Sentinel Lymph Node Biopsy/methods , Tomography, Emission-Computed, Single-Photon/methods , Tomography, X-Ray Computed/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...