Ann Clin Microbiol Antimicrob ; 15(1): 47, 2016 Aug 08.
Article in English | MEDLINE | ID: mdl-27503600

ABSTRACT

BACKGROUND: A growing number of rapid Helicobacter pylori antibody tests are commercially available now, however, some of these tests are often used without sufficient evaluation. The aim of this study was to evaluate the performance of a commercially available rapid whole-blood immunoassay (gabControl(®) H. pylori; gabmed GmbH, Köln, Germany), for the qualitative detection of IgG antibodies against H. pylori with the (13)C-urea breath test ((13)C-UBT) serving as a reference method. METHODS: A total of 108 consecutive outpatients, who were referred for (13)C-UBT by general practitioners and specialists, were also tested for H. pylori infection by the gabControl(®) H. pylori immunoassay. The clinical performance of this rapid whole-blood test was evaluated by determining the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) compared to the (13)C-UBT. The agreement between the two tests was calculated using Cohen's Kappa (κ) with 95 % confidence intervals (CI). RESULTS: The agreement between the gabControl(®) H. pylori assay and the (13)C-UBT was 0.62 [95 % confidence intervals (CIs) 0.47-0.76; P < 0.001]. With the (13)C-UBT serving as the non-invasive gold standard method of H. pylori diagnosis, the gabControl(®) H. pylori assay demonstrated a sensitivity and specificity of 91.4 and 76.7 %, respectively, with a PPV of 65.3 % and a NPV of 94.9 %. Seventeen (15.7 %) individuals with a positive H. pylori anamnesis showed a negative (13)C-UBT and were typed positive by the gabControl(®) H. pylori assay. Of these, 13 (76.5 %) and 3 individuals (17.6 %) had completed one and two eradication therapies, respectively. CONCLUSIONS: The gabControl(®) H. pylori immunoassay is a rapid and easy to use first line screening tool for H. pylori IgG antibody detection in daily clinical practice. However, this assay should not be used for confirmation of the successful H. pylori eradication after antibiotic treatment.


Subject(s)
Antibodies, Bacterial/blood , Bacteremia/diagnosis , Helicobacter Infections/diagnosis , Helicobacter pylori/isolation & purification , Immunoassay/standards , Immunoglobulin G/blood , Adolescent , Adult , Aged , Aged, 80 and over , Anti-Bacterial Agents/therapeutic use , Bacteremia/drug therapy , Bacteremia/microbiology , Breath Tests , Carbon Isotopes , Germany , Helicobacter Infections/drug therapy , Helicobacter Infections/microbiology , Helicobacter pylori/immunology , Humans , Middle Aged , Sensitivity and Specificity , Urea/analysis , Urea/metabolism
2.
Therap Adv Gastroenterol ; 9(3): 265-72, 2016 May.
Article in English | MEDLINE | ID: mdl-27134657

ABSTRACT

BACKGROUND: Diagnosis of small intestinal bacterial overgrowth (SIBO) remains challenging. This study aimed at proving the diagnostic concept of carbohydrate-specific SIBO (cs-SIBO) using glucose, fructose and sorbitol hydrogen (H2)/methane (CH4) breath testing (HMBT). METHODS: In this study 125 patients referred to our outpatient clinic for SIBO testing were included. All individuals underwent glucose (50 g), fructose (25 g) and sorbitol (12.5 g) HMBT at 3 consecutive days. Patients with cs-SIBO (i.e. early H2/CH4 peak) were given rifaximin (600 mg/day) in a 10-day treatment. HMBT results were reassessed in a subset of patients 3-6 months after antibiotic therapy. In view of cs-SIBO diagnosis, agreements between HMBT results obtained for different sugars were calculated using Cohen's kappa (κ) with 95% confidence intervals (CIs). RESULTS: A total of 59 (47.2%) patients presented an early H2/CH4 peak with one or more sugars. Among these, 21 (16.8%), 10 (8.0%) and 7 (5.6%) individuals had a positive HMBT result with either glucose, fructose or sorbitol, respectively. Another 21 (16.8%) patients with a positive glucose HMBT result were also found positive with an early H2/CH4 peak obtained after ingestion of fructose and/or sorbitol. Fair agreement was observed between glucose and fructose (κ = 0.26, p = 0.0018) and between glucose and sorbitol (κ = 0.18, p = 0.0178) HMBT results. Slight agreement was observed between fructose and sorbitol (κ = 0.03, p = 0.6955) HMBT results only. Successful antibiotic therapy with rifaximin could be demonstrated in 26/30 (86.7%) of patients as indicated by normal HMBT results and symptom remission. CONCLUSIONS: Combined glucose, fructose and sorbitol HMBT has the potential to optimize cs-SIBO diagnosis. Furthermore, the majority of patients with cs-SIBO seem to benefit from rifaximin therapy regardless of its carbohydrate specificity.

3.
Clin Lab ; 62(4): 727-30, 2016.
Article in English | MEDLINE | ID: mdl-27215094

ABSTRACT

BACKGROUND: Genetic testing is a standard technique for the diagnosis of primary adult-type hypolactasia, also referred to as lactase non-persistence. The aim of this study was to compare the lactase gene (LCT) C/T-13910 polymorphism genotyping results of two commercially available real-time (RT)-PCR assays in patients referred to our outpatient clinic for primary lactose malabsorption testing. Furthermore, concomitant conditions of fructose/sorbitol malabsorption were assessed. METHODS: Samples obtained from 100 patients were tested in parallel using the LCT T-13910C ToolSet for Light Cycler (Roche, Rotkreuz, Switzerland) and the LCT-13910C>T RealFast Assay (ViennaLab Diagnostics GmbH, Vienna, Austria). Additionally, patients were also screened for the presence of fructose/sorbitol malabsorption by functional hydrogen (H2)/methane (CH4) breath testing (HMBT). Cohen's Kappa (κ) was used to calculate the agreement between the two genotyping methods. The exact Chi-Square test was performed to compare fructose/sorbitol HMBT with LCT genotyping results. RESULTS: Twenty-one (21.0%) patients had a LCT C/C-13910 genotype suggestive of lactase non-persistence, and 79 (79.0%) patients were identified with either a LCT T/C-13910 or T/T-13910 genotype (i.e., lactase persistence). In all genotype groups, concordance between the two RT-PCR assays was 100%. Cohen's κ demonstrated perfect observed agreement (p < 0.001, κ = 1). Fructose and sorbitol malabsorption was observed in 13/100 (13.0%) and 25/100 (25.0%) individuals, respectively. CONCLUSIONS: Both RT-PCR assays are robust and reliable LCT genotyping tools in a routine clinical setting. Concomitant fructose and/or sorbitol malabsorption should be considered in individuals with suspected lactase-non-persistence. However, standardization of clinical interpretation of laboratory HMBT results is required.


Subject(s)
Fructose/pharmacokinetics , Lactase/deficiency , Lactase/genetics , Lactose Intolerance/diagnosis , Real-Time Polymerase Chain Reaction/methods , Sorbitol/pharmacokinetics , Adolescent , Adult , Aged , Aged, 80 and over , Breath Tests , Female , Genotype , Humans , Male , Methane/metabolism , Middle Aged
4.
Digestion ; 92(1): 32-8, 2015.
Article in English | MEDLINE | ID: mdl-26138365

ABSTRACT

BACKGROUND/AIMS: While lactose malabsorption is a well-investigated condition, few epidemiologic data are available for fructose and sorbitol malabsorption. The aim of this study was to assess the prevalence rates for primary lactose malabsorption, fructose and sorbitol malabsorption, and carbohydrate-specific small intestinal bacterial overgrowth (cs-SIBO) in an Austrian outpatient center. METHODS: In total, 306 adult patients, who were primarily referred with suspected carbohydrate malabsorption by general practitioners to our outpatient clinic, underwent genetic testing (C/T-13910 polymorphism) for primary lactose malabsorption, and a combined hydrogen (H2)/methane (CH4) breath test for fructose (25 g) and sorbitol (12.5 g) malabsorption. Cohen's kappa (κ) was calculated for agreement between positive breath test results and self-reported symptoms during the test. RESULTS: Seventy-eight (25.49%) patients were C/C-13910 homozygotes, indicating primary lactose malabsorption. Thirty-four (11.11%) and 57 (18.63%) patients were classified as fructose and sorbitol malabsorbers. Cohen's κ measuring agreements between positive fructose and sorbitol breath test results and self-reported symptoms during the test were 0.33 and 0.49, respectively. Twenty-nine (9.50%) patients with an early H2/CH4 peak (i.e. within 60 minutes after fructose and/or sorbitol ingestion) were diagnosed with cs-SIBO. CONCLUSION: In Austria, carbohydrate malabsorption is a frequent condition in patients referred by general practitioners to carbohydrate malabsorption testing.


Subject(s)
Fructose/metabolism , Malabsorption Syndromes/epidemiology , Sorbitol/metabolism , Adolescent , Adult , Aged , Aged, 80 and over , Ambulatory Care Facilities/statistics & numerical data , Austria/epidemiology , Blind Loop Syndrome/epidemiology , Blind Loop Syndrome/genetics , Blind Loop Syndrome/metabolism , Breath Tests/methods , Female , Fructose Intolerance/epidemiology , Fructose Intolerance/genetics , Homozygote , Humans , Hydrogen , Lactose Intolerance/epidemiology , Lactose Intolerance/genetics , Malabsorption Syndromes/genetics , Malabsorption Syndromes/metabolism , Male , Methane , Middle Aged , Prevalence , Young Adult
5.
Biochem Med (Zagreb) ; 25(2): 203-12, 2015.
Article in English | MEDLINE | ID: mdl-26110032

ABSTRACT

INTRODUCTION: Recently several diagnostic manufacturers have launched new 25-hydroxy-vitamin D (25[OH]D) assays, which are aligned to the National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM) (NIST, Gaithersburg, Maryland). The aim of this study was to compare the performance of one liquid chromatography-tandem mass spectrometry (LC-MS/MS) method, one enzyme linked immunosorbent assay (ELISA), and one recalibrated and previous version of a chemiluminescence immunoassay (CLIA). MATERIAL AND METHODS: Serum-aliquots of 198 patient samples from routine 25(OH)D analysis were measured by the ClinMass® LC-MS/MS Complete Kit (RECIPE Chemicals+Instruments GmbH, Munich, Germany), the ORGENTEC 25(OH)D3/D2 ELISA (ORGENTEC Diagnostika GmbH, Mainz, Germany), the recalibrated Immunodiagnostic Systems (IDS)-iSYS 25(OH)DS and the previous used IDS-iSYS 25(OH)D CLIA (Immunodiagnostic Systems Ltd, Boldon, United Kingdom). Bland-Altman and Deming regression analyses were calculated for methods comparison of all tested 25(OH)D assays. The LC-MS/MS method was defined as the reference method. Within-run and between-run precision measurements were performed for all methods with three different concentration levels. RESULTS: Compared to the LC-MS/MS method, the new IDS-iSYS 25(OH)DS and ORGENTEC 25(OH)D3/D2 assay demonstrated mean relative biases of 16.3% and 17.8%. The IDS-iSYS 25(OH)D assay showed the lowest mean bias of 1.5%. Deming regression analyses of the recalibrated IDS-iSYS 25(OH)DS and the ORGENTEC 25(OH)D3/D2 assay showed proportional differences, when compared to the reference method. All assays showed a within-run and between-run imprecision of ≤20% at each of the evaluated concentration levels. CONCLUSIONS: The evaluated standardized immunoassays and LC-MS/MS are useful methods for measuring 25(OH)D serum-levels in clinical laboratories.


Subject(s)
Mass Spectrometry/methods , Mass Spectrometry/standards , Vitamin D/analogs & derivatives , Chromatography, Liquid/methods , Chromatography, Liquid/standards , Female , Humans , Male , Reference Standards , Vitamin D/blood
6.
Clin Biochem ; 48(13-14): 891-6, 2015 Sep.
Article in English | MEDLINE | ID: mdl-25980732

ABSTRACT

OBJECTIVES: No full international consensus exists on disease markers to be used for assessing the human iron status. Therefore this study was conducted to compare performances of serum ferritin and transferrin saturation (TSAT) versus soluble transferrin receptor (sTfR)/log ferritin and reticulocyte hemoglobin content (CHr), also known as Thomas-plot, in the diagnosis of iron deficiency (ID). DESIGN AND METHODS: A total of 445 consecutive hospitalized patients, referred for routine testing of the actual iron status, were included. Logistic regression models for the probability of functional ID (CHr<28pg) were constructed for all 445 patients, for 225 patients without (C-reactive protein [CRP]≤0.5mg/dL) and 220 patients with acute-phase reaction (CRP>0.5mg/dL). RESULTS: Based on the Thomas-plot analyses, 153/445 (34.38%) patients were identified with ID. When ID was diagnosed by means of serum ferritin levels<30ng/mL and TSAT levels<20%, 105/445 (23.60%) and 215/445 (48.31%) patients were identified with ID, respectively. The sTfR/log ferritin ratio showed the best positive predictive values (PPV) (62.50 and 64.41%) to indicate functional ID in patients without as well as with acute-phase reaction compared to sTfR (58.14 and 61.67%), ferritin (32.50 and 32.86%) and TSAT (26.74 and 42.86%). CONCLUSIONS: In clinical practice, the prevalence of ID and the accuracy to detect functional ID are dependent on marker selection and its definition. Regarding the results of this work, for laboratory investigation of ID, however, we suggest using Thomas-plot analyses in combination with ferritin single-marker measurements to efficiently identify patients with ID.


Subject(s)
Biomarkers/blood , Clinical Laboratory Services , Iron Deficiencies , Iron/blood , Acute-Phase Reaction/blood , Adolescent , Adult , Aged , Cross-Sectional Studies , Demography , Female , Ferritins/blood , Humans , Logistic Models , Male , Middle Aged , Predictive Value of Tests , ROC Curve , Transferrin/metabolism , Young Adult
7.
Eur J Haematol ; 95(6): 507-13, 2015 Dec.
Article in English | MEDLINE | ID: mdl-25598480

ABSTRACT

OBJECTIVES: As hepcidin-25 is considered as a key regulator of human iron homoeostasis, this study aimed to compare this parameter with conventional biomarkers and diagnostic tools of iron deficiency (ID). METHODS: In total, 233 hospitalised adult patients, who underwent routine blood testing for ID, were included. All subjects were investigated for hepcidin-25, reticulocyte haemoglobin content (CHr), soluble transferrin receptor (sTfR)/log ferritin ratio (i.e. Thomas plot), sTfR, ferritin, transferrin saturation (TSAT), C-reactive protein (CRP) and for complete blood cell count. Functional ID was defined as a CHr < 28 pg. Separate logistic regression models were calculated with all potential biomarkers to evaluate and compare the predictive performance with respect to functional ID in patients without (CRP ≤ 0.5 mg/dL) and with (CRP > 0.5 mg/dL) acute-phase reaction, respectively. RESULTS: One hundred seventeen patients with CRP > 0.5 mg/dL showed a distinctly higher hepcidin-25 median value [35.60 (range: 4.27-80.03) ng/mL] as compared to 116 patients with CRP ≤ 0.5 mg/dL [18.55 (range: 3.77-73.01) ng/mL]. With respect to functional ID, sTfR/log ferritin ratio and sTfR were of better positive predictive value (PPV) (sTfR/log ferritin ratio: 58.33% and 70.83%; sTfR: 60.00% and 60.00%) than when compared to hepcidin-25 (PPV: 37.74% and 42.86%) and ferritin (PPV: 27.54% and 46.15%) in both subgroups. CONCLUSIONS: The sTfR/log ferritin ratio, as well as sTfR, were better predictors of functional ID in patients with and without acute-phase reaction as compared to hepcidin-25 and ferritin.


Subject(s)
Hepcidins/blood , Iron/metabolism , Adult , Aged , Aged, 80 and over , Anemia, Iron-Deficiency/blood , Anemia, Iron-Deficiency/diagnosis , Anemia, Iron-Deficiency/metabolism , Biomarkers , Erythrocyte Indices , Female , Hospitalization , Humans , Male , Middle Aged , ROC Curve , Reticulocyte Count , Young Adult
8.
Clin Lab ; 60(9): 1541-50, 2014.
Article in English | MEDLINE | ID: mdl-25291951

ABSTRACT

Background: Over the last decade, clinical interest to evaluate human 25-hydroxy-vitamin D (25[OH]D) serum levels has increased exponentially. In the present study, four chemiluminescence immunoassays (CLIA), one radioimmunoassy (RIA), and one high performance liquid chromatography (HPLC) method were compared and also with the liquid chromatography-tandem mass spectrometry (LC-MS/MS) method in view of 25(OH)D serum level determination. Methods: For the method comparison, blood samples from 133 consecutive patients were prospectively collected. All participants gave written informed consent for their blood samples to be used in this study. They came to the Department of Nuclear Medicine of the Central Hospital Steyr (Austria) for osteodensidometric measurement as part of their preventive medical check-up. Pearson's correlation coefficients, Bland-Altman plots, and paired t-tests were calculated. Assay-specific reference ranges were considered using blood samples from persons with normal parathormone, calcium, and total-protein values (n = 97). Results: The highest correlation was between the HPLC and the LC-MS/MS method (r = 0.96). The lowest correlation was between the cobas Vitamin D3 assay (Roche) and any of the evaluated assays (r = 0.46 - 0.63). Bland-Altman plots revealed a big negative mean bias in three assays (cobas Vitamin D3 assay [Roche]: -22.8; DiaSorin LIAISON [25[OH]D total CLIA [Diasorin]: -18.4; Diasorin 25[OH]D125 I RIA [Diasorin]: -23.8 [nmol/L]) and a much smaller positive mean bias in the other assays (ClinRep complete 25[OH]D2/D3 HPLC kit [Recipe]: 2.7; ADVIA Centaur Vitamin D total assay [Siemens]: 8.2; IDS total vitamin D assay [Immunodiagnostic Systems]: 12.1 [nmol/L]) compared to the LC-MS/MS method. Meanwhile, the manufacturer has withdrawn the cobas Vitamin D3 assay from the market. Conclusions: Poor antibody specificity with cross-reactivity to other vitamin D metabolites, incomplete extraction of the 25(OH)D analyte from the vitamin D-binding protein (DBP), and confounding matrix substances such as lipids could be potential reasons for the unacceptable performance of the cobas Vitamin D3 assay (Roche) and also the significant differences in the 25(OH)D determination between various assays. Standardization and harmonization of 25(OH)D measurements are therefore urgently needed. The widespread introduction of well standardized assays in clinical laboratories is the challenge in the next years. (Clin. Lab. 2014;60:1541-1550. DOI: 10.7754/Clin.Lab.2014.131114)


Subject(s)
Blood Chemical Analysis/standards , Vitamin D Deficiency/diagnosis , Vitamin D/analogs & derivatives , Austria , Biomarkers/blood , Chromatography, High Pressure Liquid/standards , Humans , Luminescent Measurements/standards , Predictive Value of Tests , Prospective Studies , Quality Control , Radioimmunoassay/standards , Reproducibility of Results , Tandem Mass Spectrometry/standards , Vitamin D/blood , Vitamin D Deficiency/blood
9.
Gastroenterol Res Pract ; 2014: 464382, 2014.
Article in English | MEDLINE | ID: mdl-24829570

ABSTRACT

The aim of this study was to establish a retrospective evaluation and comparison of the hydrogen/methane (H2/CH4) breath test and genetic test (C/T-13910 polymorphism) results in lactose malabsorption testing. In total 263 consecutive patients with suspected lactose malabsorption were included in this study. They underwent the H2/CH4 breath test following the ingestion of 50 g lactose and were tested for the C/T-13910 polymorphism. In total 51 patients (19.4%) had a C/C-13910 genotype, indicating primary lactose malabsorption. Only 19 patients (7.2%) also had a positive H2/CH4 breath test. All in all 136 patients (51.69%) had a C/T-13910 and 76 patients (28.91%) a T/T-13910 genotype, indicating lactase persistence. Four patients (1.5%) with the C/T-13910 genotype and one patient (0.4%) with the T/T-13910 genotype had a positive H2/CH4 breath test result, indicating secondary lactose malabsorption. Cohen's Kappa measuring agreement between the two methods was 0.44. Twenty patients (7.6%) with a positive H2/CH4 peak within 60 minutes after lactose ingestion were classified as patients with lactose-dependent small intestinal bacterial overgrowth (SIBO). In conclusion, only moderate agreement between the breath test and the genetic test was shown. Secondary lactose malabsorption as well as preanalytical limitations of the combined H2/CH4 breath test procedure can cause discrepant results. This trial is registered with K-42-13.