Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Eur Radiol ; 19(1): 110-20, 2009 Jan.
Article in English | MEDLINE | ID: mdl-18704438

ABSTRACT

The purpose of this paper is to present a pulse sequence optimized to visualize human peripheral vessels. The optimized MR technique is a 3D multi-shot balanced non-SSFP gradient echo pulse sequence with fat suppression. Several imaging parameters were adjusted to find the best compromise between the contrast of vascular structures and muscle, fat, and bone. Most of the optimization was performed in the knee and calf regions using multi-channel SENSE coils. To verify potential clinical use, images of both healthy volunteers and volunteers with varicose veins were produced. The balanced non-SSFP sequence can produce high-spatial-resolution images of the human peripheral vessels without the need for an intravenous contrast agent. Both arteries and veins are displayed along with other body fluids. Due to the high spatial resolution of the axial plane source or reconstructed images, the need for procedures to separate arteries from veins is limited. We demonstrate that high signals from synovial joint fluid and cystic structures can be suppressed by applying an inversion prepulse but at the expense of reduced image signal-to-noise and overall image quality.


Subject(s)
Algorithms , Blood Vessels/pathology , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Angiography/methods , Varicose Veins/pathology , Adult , Contrast Media , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Signal Processing, Computer-Assisted
2.
Eur Radiol ; 17(9): 2294-301, 2007 Sep.
Article in English | MEDLINE | ID: mdl-17483955

ABSTRACT

The aim was to compare bowel distension and diagnostic properties of magnetic resonance imaging of the small bowel with oral contrast (MRI per OS) with magnetic resonance enteroclysis (MRE). Forty patients with suspected Crohn's disease (CD) were examined with both MRI methods. MRI per OS was performed with a 6% mannitol solution and MRE with nasojejunal intubation and a polyethylenglycol solution. MRI protocol consisted of balanced fast field echo (B-FFE), T2 and T1 sequences with and without gadolinium. Two experienced radiologists individually evaluated bowel distension and pathological findings including wall thickness (BWT), contrast enhancement (BWE), ulcer (BWU), stenosis (BWS) and edema (EDM). The diameter of the small bowel was smaller with MRI per OS than with MRE (difference jejunum: 0.55 cm, p < 0.001; ileum: 0.35 cm, p < 0.001, terminal ileum: 0.09 cm, p = 0.08). However, CD was diagnosed with high diagnostic accuracy (sensitivity, specificity, positive and negative predictive values: MRI per OS 88%, 89%, 89%, 89%; MRE 88%, 84%, 82%, 89%) and inter-observer agreement (MRI per OS k = 0.95; MRE k = 1). In conclusion, bowel distension was inferior in MRI per OS compared to MRE. However, both methods diagnosed CD with a high diagnostic accuracy and reproducibility.


Subject(s)
Crohn Disease/diagnosis , Intestine, Small , Magnetic Resonance Imaging/methods , Administration, Oral , Adolescent , Adult , Contrast Media/administration & dosage , Female , Humans , Intubation, Gastrointestinal , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity
3.
Eur Radiol ; 13(6): 1423-7, 2003 Jun.
Article in English | MEDLINE | ID: mdl-12764661

ABSTRACT

Our purpose was to compare the quality of ureteral imaging in pediatric patients using two different MR sequences: the non-enhanced heavily T2-weighted (W) turbo spin-echo sequence (TSE) and the gadolinium-enhanced T1W fast-field-echo sequence (T1 FFE). An experimental study on three pigs was first performed. The TSE, before and after furosemide injection, was followed by the T1 FFE sequence. The clinical study included 11 infants and 10 children. With some modifications the same MR parameters and techniques were used as in the animal study. The TSE with TR 8000 ms and TE 650 ms implied 6 radial stacks each of 40 mm thickness. The T1 FFE included TR 18 ms, TE 2.9 ms, flip angle 60, and 50 slices with thickness 0.7 mm. After post-processing, image reconstructions qualitative and quantitative analysis were performed. Complete visualization of the ureters was achieved in 35 of 42 (83%) cases. Seventy-four percent of the ureters were completely visualized with T1 FFE compared with only 19% with TSE. Sixty-nine percent of the ureters were better imaged with T1 FFE than TSE and 21% equally well imaged. Four ureters (10%), either obstructed or due to poor renal function, were better imaged with TSE. The two sequences are complementary. Visualization of non-obstructed ureters is excellent with T1 FFE and the sequence is superior to TSE. The TSE, however, may be equal to or even better than T1 FFE in visualizing obstructed ureters or ureters draining malfunctioning kidneys.


Subject(s)
Magnetic Resonance Imaging/methods , Ureter/anatomy & histology , Ureteral Obstruction/diagnosis , Animals , Child , Contrast Media , Diuretics , Female , Furosemide , Gadolinium DTPA , Humans , Image Processing, Computer-Assisted , Infant , Male , Swine , Urination
SELECTION OF CITATIONS
SEARCH DETAIL
...