Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Neurosurg Spine ; 25(5): 556-565, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27258476

ABSTRACT

OBJECTIVE Recent studies have described encouraging outcomes after cervical total disc replacement (cTDR), but there are also critical debates regarding the long-term effects of heterotopic ossification (HO) and the prevalence of adjacent-level degeneration. The aim in this paper was to provide 4-year clinical and radiographic outcome results on the activ C disc prosthesis. METHODS A total of 200 subjects underwent single-level activ C (Aesculap AG) implantation between C-3 and C-7 for the treatment of symptomatic degenerative disc disease. Clinical and radiographic assessments were performed preoperatively, intraoperatively, at discharge, and again at 6 weeks, 6 months, 1 year, 2 years, and 4 years. Radiographic evaluations were done by an independent core laboratory using a specific software for quantitative motion analysis. RESULTS Neck Disability Index (NDI) and visual analog scale (VAS) score for neck and arm pain decreased significantly from baseline to the 4-year follow-up. The mean improvement for NDI was 20, for VAS severity and frequency of neck pain 26.4 and 28, and for VAS severity and frequency of arm pain 30.7 and 35.1, respectively. The neurological situation improved for the majority of patients (86.4%); 76.1% of cases were asymptomatic. Subsequent surgical interventions were reported in 7% of the cases, including device removals in 3%. In 2.5% a subsidence greater than 3 mm was recorded; 1 of these cases also had a migration greater than 3 mm. No device displacement, expulsion, disassembly, loose or fractured device, osteolysis, or facet joint degeneration at the index level was observed. Segmental lordotic alignment changed from -2.4° preoperatively to -6.2° at 4 years, and postoperative height was maintained during the follow-up. Advanced HO (Grade III and IV) was present in 27.1% of the cases; 82.4% showed segmental mobility. A progression of radiographic adjacent-segment degeneration occurred in 28.2%, but only 4.5% required surgical treatment. CONCLUSIONS The activ C is a safe and effective device for cervical disc replacement confirming the encouraging results after cTDR. Clinical trial registration no.: NCT02492724 ( clinicaltrials.gov ).


Subject(s)
Cervical Vertebrae , Intervertebral Disc Degeneration/diagnostic imaging , Intervertebral Disc Degeneration/surgery , Joint Prosthesis , Total Disc Replacement , Adult , Decompression, Surgical/methods , Disability Evaluation , Diskectomy/methods , Europe , Female , Follow-Up Studies , Humans , Intervertebral Disc Degeneration/complications , Lordosis/diagnostic imaging , Lordosis/etiology , Lordosis/surgery , Male , Neck Pain/diagnostic imaging , Neck Pain/etiology , Neck Pain/surgery , Pain Measurement , Prospective Studies , Severity of Illness Index , Software , Time Factors , Total Disc Replacement/instrumentation , Total Disc Replacement/methods , Treatment Outcome
2.
Ann Surg Innov Res ; 8: 7, 2014.
Article in English | MEDLINE | ID: mdl-26628910

ABSTRACT

BACKGROUND: The zygapophysial (facet) joint is the primary pain generator in one third of chronic low back pain cases. Current treatment options include temporarily palliative nonsurgical approaches, facet injections, radiofrequency denervation, and, rarely, lumbar arthrodesis. The purpose of this study was to assess the safety and effectiveness of a minimally invasive implant intended to restore facet joint function in patients with chronic lumbar facetogenic pain. METHODS: This prospective, multi-center feasibility study enrolled patients with confirmed lumbar facetogenic joint pain at 1 or 2 levels who underwent at least 6 months of unsuccessful nonoperative care. Patients received a minimally invasive implant (Glyder® Facet Restoration Device, Zyga Technology, Inc., Minnetonka, MN) intended to restore facet joint function while preserving the native anatomy. Main outcomes included back pain severity using a visual analogue scale, back-specific disability using the Oswestry Disability Index (ODI), and adverse events adjudicated by an independent Clinical Events Committee. RESULTS: Of 40 enrolled patients, 37 patients received the facet restoration implant and 34 patients had complete 1-year follow-up data available. Over the 1-year follow-up period, back pain severity decreased 41% and ODI decreased 34%, on average. Freedom from a device- or procedure-related serious adverse event through 1 year was 84%. Implant migration was observed in 3 patients and implant expulsion from the facet joint occurred in 3 patients. In total, 2 (5.4%) patients underwent implant removal through 1 year post-treatment. CONCLUSIONS: A minimally invasive facet restoration implant is a promising treatment option in select patients with chronic lumbar zygapophysial pain who have exhausted nonsurgical treatments, with therapeutic benefit persisting at 1 year follow-up.

SELECTION OF CITATIONS
SEARCH DETAIL
...