Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
Add more filters










Publication year range
1.
J Proteome Res ; 21(3): 798-807, 2022 03 04.
Article in English | MEDLINE | ID: mdl-34382401

ABSTRACT

The ability to improve the data quality of ion mobility-mass spectrometry (IM-MS) measurements is of great importance for enabling modular and efficient computational workflows and gaining better qualitative and quantitative insights from complex biological and environmental samples. We developed the PNNL PreProcessor, a standalone and user-friendly software housing various algorithmic implementations to generate new MS-files with enhanced signal quality and in the same instrument format. Different experimental approaches are supported for IM-MS based on Drift-Tube (DT) and Structures for Lossless Ion Manipulations (SLIM), including liquid chromatography (LC) and infusion analyses. The algorithms extend the dynamic range of the detection system, while reducing file sizes for faster and memory-efficient downstream processing. Specifically, multidimensional smoothing improves peak shapes of poorly defined low-abundance signals, and saturation repair reconstructs the intensity profile of high-abundance peaks from various analyte types. Other functionalities are data compression and interpolation, IM demultiplexing, noise filtering by low intensity threshold and spike removal, and exporting of acquisition metadata. Several advantages of the tool are illustrated, including an increase of 19.4% in lipid annotations and a two-times faster processing of LC-DT IM-MS data-independent acquisition spectra from a complex lipid extract of a standard human plasma sample. The software is freely available at https://omics.pnl.gov/software/pnnl-preprocessor.


Subject(s)
Ion Mobility Spectrometry , Lipids , Chromatography, Liquid/methods , Humans , Ion Mobility Spectrometry/methods , Ions , Mass Spectrometry/methods , Workflow
2.
J Am Soc Mass Spectrom ; 32(10): 2592-2603, 2021 Oct 06.
Article in English | MEDLINE | ID: mdl-34515480

ABSTRACT

Ion mobility as an additional separation dimension can help to resolve and annotate metabolite and lipid biomarkers and provides important information about the components in a sample. Identifying relevant information in the resulting data is challenging because of the complexity of the data and data evaluation strategies for both targeted or nontargeted workflows. Frequently, feature analysis is used as a first step to search for differences between samples in discovery workflows. However, follow-up experimentation often leads to more targeted data extraction methods. In both cases, optimizing data sets for data extraction can make an important contribution to the overall results. In this work, we evaluate the effect of experimental conditions including acquisition sampling rate and data pretreatment on lipid standards and lipid extracts as examples of complex biological samples analyzed by liquid chromatography coupled to drift time ion mobility quadrupole time-of-flight mass spectrometry. The results show that a reduction of both peak variation and background noise can be achieved by optimizing the sampling rate. The use of data pretreatment including data smoothing, intensity thresholding, and spike removal also play an important role in improving detection and annotation of analytes from complex biological samples, whereas nonoptimal data sampling rates and preprocessing can lead to adverse effects including the loss or alternation of small, or closely eluting, low-abundant peaks.


Subject(s)
Chromatography, Liquid/methods , Ion Mobility Spectrometry/methods , Lipids/analysis , Hep G2 Cells , Humans , Limit of Detection , Lipids/chemistry , Specimen Handling
3.
Metabolites ; 10(3)2020 Mar 12.
Article in English | MEDLINE | ID: mdl-32178227

ABSTRACT

Lipidomics has great promise in various applications; however, a major bottleneck in lipidomics is the accurate and comprehensive annotation of high-resolution tandem mass spectral data. While the number of available lipidomics software has drastically increased over the past five years, the reduction of false positives and the realization of obtaining structurally accurate annotations remains a significant challenge. We introduce Lipid Annotator, which is a user-friendly software for lipidomic analysis of data collected by liquid chromatography high-resolution tandem mass spectrometry (LC-HRMS/MS). We validate annotation accuracy against lipid standards and other lipidomics software. Lipid Annotator was integrated into a workflow applying an iterative exclusion MS/MS acquisition strategy to National Institute of Standards and Technology (NIST) SRM 1950 Metabolites in Frozen Human Plasma using reverse phase LC-HRMS/MS. Lipid Annotator, LipidMatch, and MS-DIAL produced consensus annotations at the level of lipid class for 98% and 96% of features detected in positive and negative mode, respectively. Lipid Annotator provides percentages of fatty acyl constituent species and employs scoring algorithms based on probability theory, which is less subjective than the tolerance and weighted match scores commonly used by available software. Lipid Annotator enables analysis of large sample cohorts and improves data-processing throughput as compared to previous lipidomics software.

4.
Anal Chem ; 90(24): 14453-14461, 2018 12 18.
Article in English | MEDLINE | ID: mdl-30479133

ABSTRACT

Matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) is used to characterize methylenedianiline (MDA) 3-ring and 4-ring species. Building on our previous MALDI-MS 2-ring MDA isomer study, here we compare 3-ring and 4-ring electrospray ionization (ESI) and MALDI results. In ESI, 3-ring and 4-ring MDAs each form a single [M + H]+ parent ion. However, in MALDI, each MDA multimer forms three unique precursor ions: [M + H]+, [M•]+, and [M - H]+. In this study, 3-ring and 4-ring MDA precursors are characterized to identify the unique fragment ions formed and their respective fragmentation pathways. In addition to the three possible precursors, the 3-ring and 4-ring species are higher-order oligomer precursors in polyurethane (PUR) production and thus provide additional insight into the polymeric behavior of these PUR hard block precursors. The combination of ion mobility-mass spectrometry (IM - MS) and tandem mass spectrometry (MS/MS) allow the structural characterization of these larger MDA multimers.


Subject(s)
Aniline Compounds/chemistry , Ion Mobility Spectrometry , Tandem Mass Spectrometry , Stereoisomerism
5.
Int J Mass Spectrom ; 427: 79-90, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29915518

ABSTRACT

In this study, a commercial uniform field drift tube ion mobility-mass spectrometer (IM-MS) was utilized to measure the gas-phase conformational populations of three well-studied proteins: ubiquitin (8566 Da), cytochrome c (12,359 Da), and myoglobin in both apo and holo forms (16,951 and 17,567 Da, respectively) in order to evaluate the use of this technology for broadscale structural proteomics applications. Proteins were electrosprayed from either acidic organic (pH ~3) or aqueous buffered (pH ~6.6) solution phase conditions, which generated a wide range of cation charge states corresponding to both extended (unfolded) and compact (folded) gas-phase conformational populations. Corresponding collision cross section (CCS) measurements were compiled for significant ion mobility peak features observed at each charge state in order to map the conformational landscapes of these proteins in both helium and nitrogen drift gases. It was observed that the conformational landscapes were similar in both drift gases, with differences being attributed primarily to ion heating during helium operation due to the necessity of operating the instrument with higher pressure differentials. Higher resolving powers were observed in nitrogen, which allowed for slightly better structural resolution of closely-spaced conformer populations. The instrumentation was found to be particularly adept at measuring low abundance conformers which are only present under gentle conditions which minimize ion heating. This work represents the single largest ion mobility CCS survey published to date for these three proteins with 266 CCS values and 117 ion mobility spectra, many of which have not been previously reported.

6.
Anal Chem ; 89(18): 9900-9910, 2017 09 19.
Article in English | MEDLINE | ID: mdl-28803462

ABSTRACT

Characterization of methylenedianiline (MDA) 2-ring isomers (2,2'-, 2,4'-, and 4,4'-MDA) is reported using matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS), a common technique used for characterizing synthetic polymers. MDA is a precursor to methylene diphenyl diisocyanate (MDI), a hard block component in polyurethane (PUR) synthesis. This work focuses on comparing MALDI results to those of our previous electrospray ionization-mass spectrometry (ESI-MS) studies. In ESI, 2-ring MDA isomers formed single unique [M + H]+ (199 Da) parent ions, whereas in MALDI each isomer shows significant formation of three precursor ions: [M - H]+ = 197 Da, [M•]+ = 198 Da, and [M + H]+ = 199 Da. Structures and schemes are proposed for the MALDI fragment ions associated with each precursor ion. Ion mobility-mass spectrometry (IM-MS), tandem mass spectrometry (MS/MS), and computational methods were all critical in determining the structures for both precursor and fragment ions as well as the fragmentation mechanisms. The present study indicates that the [M - H]+ and [M•]+ ions are formed by the MALDI process, explaining why they were not observed with ESI.


Subject(s)
Aniline Compounds/chemistry , Density Functional Theory , Molecular Dynamics Simulation , Ion Mobility Spectrometry , Mass Spectrometry , Molecular Structure , Stereoisomerism
7.
Anal Chem ; 89(17): 9048-9055, 2017 09 05.
Article in English | MEDLINE | ID: mdl-28763190

ABSTRACT

Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental parameters influencing IM separations provide standardized drift tube, nitrogen CCS values (DTCCSN2) for over 120 unique ion species with the lowest measurement uncertainty to date. The reproducibility of these DTCCSN2 values are evaluated across three additional laboratories on a commercially available DTIM-MS instrument. The traditional stepped field CCS method performs with a relative standard deviation (RSD) of 0.29% for all ion species across the three additional laboratories. The calibrated single field CCS method, which is compatible with a wide range of chromatographic inlet systems, performs with an average, absolute bias of 0.54% to the standardized stepped field DTCCSN2 values on the reference system. The low RSD and biases observed in this interlaboratory study illustrate the potential of DTIM-MS for providing a molecular identifier for a broad range of discovery based analyses.


Subject(s)
Ion Mobility Spectrometry/methods , Laboratories/standards , Mass Spectrometry/methods , Calibration , Lipids/chemistry , Molecular Structure , Nitrogen/chemistry , Proteins/chemistry , Reproducibility of Results
8.
Anal Chim Acta ; 939: 64-72, 2016 Oct 05.
Article in English | MEDLINE | ID: mdl-27639144

ABSTRACT

Ion mobility (IM) is an important analytical technique for determining ion collision cross section (CCS) values in the gas-phase and gaining insight into molecular structures and conformations. However, limited instrument resolving powers for IM may restrict adequate characterization of conformationally similar ions, such as structural isomers, and reduce the accuracy of IM-based CCS calculations. Recently, we introduced an automated technique for extracting "pure" IM and collision-induced dissociation (CID) mass spectra of IM overlapping species using chemometric deconvolution of post-IM/CID mass spectrometry (MS) data [J. Am. Soc. Mass Spectrom., 2014, 25, 1810-1819]. Here we extend those capabilities to demonstrate how extracted IM profiles can be used to calculate accurate CCS values of peptide isomer ions which are not fully resolved by IM. We show that CCS values obtained from deconvoluted IM spectra match with CCS values measured from the individually analyzed corresponding peptides on uniform field IM instrumentation. We introduce an approach that utilizes experimentally determined IM arrival time (AT) "shift factors" to compensate for ion acceleration variations during post-IM/CID and significantly improve the accuracy of the calculated CCS values. Also, we discuss details of this IM deconvolution approach and compare empirical CCS values from traveling wave (TW)IM-MS and drift tube (DT)IM-MS with theoretically calculated CCS values using the projected superposition approximation (PSA). For example, experimentally measured deconvoluted TWIM-MS mean CCS values for doubly-protonated RYGGFM, RMFGYG, MFRYGG, and FRMYGG peptide isomers were 288.8 Å(2), 295.1 Å(2), 296.8 Å(2), and 300.1 Å(2); all four of these CCS values were within 1.5% of independently measured DTIM-MS values.

9.
Polymer (Guildf) ; 64: 100-111, 2015 May 01.
Article in English | MEDLINE | ID: mdl-26195848

ABSTRACT

MALDI-TOF/TOF collision-induced dissociation (CID) experiments were conducted on model aromatic polyester oligomers. CID fragmentation studies identified initial fracture of the ester bond and subsequent CO loss as a major pathway, consistent with the general fragmentation mechanism used to explain the origin of poly(p-phenylenediamine terephthalamide) (PPD-T) fragment ions. Specifically, both charge-remote and charge-site fragmentation were observed. Different parent-ion species were observed, the major ones being carboxyl-hydroxyl, di-carboxyl, di-hydroxyl, and phenyl-carboxyl terminated. One species observed was hydroxyl-diethylamine terminated caused by reaction of carboxyl groups with triethylamine added to the synthesis reaction mixture. Fragment ions reflected the end groups of the parent oligomers. Some MALDI fragment-ion spectra were obtained for species showing exchange between Li and H at the carboxyl end group. Bond energy calculations provide further insight into suggested fragmentation mechanisms.

10.
Anal Chem ; 87(12): 6288-96, 2015 Jun 16.
Article in English | MEDLINE | ID: mdl-25971782

ABSTRACT

Building on results from our previous study of 2-ring methylenedianiline (MDA), a combined mass spectrometry approach utilizing ion mobility-mass spectrometry (IM-MS) and tandem mass spectrometry (MS/MS) coupled with computational methods enables the structural characterization of purified 3-ring and 4-ring MDA regioisomers in this current study. The preferred site of protonation for the 3-ring and 4-ring MDA was determined to be on the amino groups. Additionally, the location of the protonated amine along the MDA multimer was found to influence the gas phase stability of these molecules. Fragmentation mechanisms similar to the 2-ring MDA species were observed for both the 3-ring and 4-ring MDA. The structural characterization of 3-ring and 4-ring MDA isomers using modern MS techniques may aid polyurethane synthesis by the characterization of industrial grade MDA, multimeric MDA species, and methylene diphenyl diisocyanate (MDI) mixtures.


Subject(s)
Aniline Compounds/chemistry , Computer Simulation , Molecular Structure , Spectrometry, Mass, Electrospray Ionization , Stereoisomerism , Tandem Mass Spectrometry
11.
J Phys Chem B ; 118(48): 13812-20, 2014 Dec 04.
Article in English | MEDLINE | ID: mdl-25360896

ABSTRACT

Ion mobility-mass spectrometry (IM-MS) allows the separation of ionized molecules based on their charge-to-surface area (IM) and mass-to-charge ratio (MS), respectively. The IM drift time data that is obtained is used to calculate the ion-neutral collision cross section (CCS) of the ionized molecule with the neutral drift gas, which is directly related to the ion conformation and hence molecular size and shape. Studying the conformational landscape of these ionized molecules computationally provides interpretation to delineate the potential structures that these CCS values could represent, or conversely, structural motifs not consistent with the IM data. A challenge in the IM-MS community is the ability to rapidly compute conformations to interpret natural product data, a class of molecules exhibiting a broad range of biological activity. The diversity of biological activity is, in part, related to the unique structural characteristics often observed for natural products. Contemporary approaches to structurally interpret IM-MS data for peptides and proteins typically utilize molecular dynamics (MD) simulations to sample conformational space. However, MD calculations are computationally expensive, they require a force field that accurately describes the molecule of interest, and there is no simple metric that indicates when sufficient conformational sampling has been achieved. Distance geometry is a computationally inexpensive approach that creates conformations based on sampling different pairwise distances between the atoms within the molecule and therefore does not require a force field. Progressively larger distance bounds can be used in distance geometry calculations, providing in principle a strategy to assess when all plausible conformations have been sampled. Our results suggest that distance geometry is a computationally efficient and potentially superior strategy for conformational analysis of natural products to interpret gas-phase CCS data.


Subject(s)
Biological Products/chemistry , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization , Gases/chemistry , Ions/chemistry , Molecular Conformation , Molecular Dynamics Simulation , Peptides/chemistry , Proteins/chemistry
12.
J Am Chem Soc ; 136(38): 13363-70, 2014 Sep 24.
Article in English | MEDLINE | ID: mdl-25174489

ABSTRACT

Herein, we report chemistry that enables excitation energy transfer (EET) to be accurately measured via action spectroscopy on gaseous ions in an ion trap. It is demonstrated that EET between tryptophan or tyrosine and a disulfide bond leads to excited state, homolytic fragmentation of the disulfide bond. This phenomenon exhibits a tight distance dependence, which is consistent with Dexter exchange transfer. The extent of fragmentation of the disulfide bond can be used to determine the distance between the chromophore and disulfide bond. The chemistry is well suited for the examination of protein structure in the gas phase because native amino acids can serve as the donor/acceptor moieties. Furthermore, both tyrosine and tryptophan exhibit unique action spectra, meaning that the identity of the donating chromophore can be easily determined in addition to the distance between donor/acceptor. Application of the method to the Trpcage miniprotein reveals distance constraints that are consistent with a native-like fold for the +2 charge state in the gas phase. This structure is stabilized by several salt bridges, which have also been observed to be important previously in proteins that retain native-like structures in the gas phase. The ability of this method to measure specific distance constraints, potentially at numerous positions if combined with site-directed mutagenesis, significantly enhances our ability to examine protein structure in the gas phase.


Subject(s)
Disulfides/chemistry , Peptides/chemistry , Tryptophan/chemistry , Tyrosine/chemistry , Amino Acid Sequence , Energy Transfer , Gases/chemistry , Ions/chemistry , Mass Spectrometry , Models, Molecular , Molecular Sequence Data , Photochemical Processes
13.
Anal Chem ; 86(9): 4362-70, 2014 May 06.
Article in English | MEDLINE | ID: mdl-24678803

ABSTRACT

Purified methylenedianiline (MDA) regioisomers were structurally characterized and differentiated using tandem mass spectrometry (MS/MS), ion mobility-mass spectrometry (IM-MS), and IM-MS/MS in conjunction with computational methods. It was determined that protonation sites on the isomers can vary depending on the position of amino groups, and the resulting protonation sites play a role in the gas-phase stability of the isomer. We also observed differences in the relative distributions of protonated conformations depending on experimental conditions and instrumentation, which is consistent with previous studies on aniline in the gas phase. This work demonstrates the utility of a multifaceted approach for the study of isobaric species and elucidates why previous MDA studies may have been unable to detect and/or differentiate certain isomers. Such analysis may prove useful in the characterization of larger MDA multimeric species, industrial MDA mixtures, and methylene diphenyl diisocyanate (MDI) mixtures used in polyurethane synthesis.

14.
Anal Chim Acta ; 808: 124-43, 2014 Jan 15.
Article in English | MEDLINE | ID: mdl-24370099

ABSTRACT

MALDI-TOF/TOF collision-induced dissociation (CID) experiments are reported on model poly(p-phenylenediamine terephthalamide) (PPD-T) polymers, revealing a variety of synthesis reaction products. Diamine-terminated oligomers were the major product of synthesis using excess amine, and di-carboxylic acid oligomers were the major product for excess acid. Structures of major reaction products were confirmed by CID fragmentation studies, along with detailed studies of MS/MS decomposition pathways. Apparent fracture of the phenylcarbonyl bond was the major fragmentation pathway (independent of end groups), resulting from initial NHCO bond cleavage with subsequent CO loss. Hydrogen-transfer reactions play an important role in fragmentation, involving both cross-chain abstraction of NH hydrogen and long-range H-transfer. End-group and main-chain modifications produce fingerprint CID fragmentation patterns that can be used to identify end groups and branching patterns; the structure of an unanticipated synthesis product was established using CID. The effect of synthesis conditions on polymer composition was studied using the analysis of variance, specifically, the amine-to-acid ratio used and post-synthesis addition of CaO. Of particular interest is oligomer end-group modification by the solvent (N-methyl pyrrolidone) induced by addition of CaO.

SELECTION OF CITATIONS
SEARCH DETAIL
...