Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 19(4): e0300122, 2024.
Article in English | MEDLINE | ID: mdl-38578724

ABSTRACT

We introduce the concept photophysical image analysis (PIA) and an associated pipeline for unsupervised probabilistic image thresholding for images recorded by electron-multiplying charge-coupled device (EMCCD) cameras. We base our approach on a closed-form analytic expression for the characteristic function (Fourier-transform of the probability mass function) for the image counts recorded in an EMCCD camera, which takes into account both stochasticity in the arrival of photons at the imaging camera and subsequent noise induced by the detection system of the camera. The only assumption in our method is that the background photon arrival to the imaging system is described by a stationary Poisson process (we make no assumption about the photon statistics for the signal). We estimate the background photon statistics parameter, λbg, from an image which contains both background and signal pixels by use of a novel truncated fit procedure with an automatically determined image count threshold. Prior to this, the camera noise model parameters are estimated using a calibration step. Utilizing the estimates for the camera parameters and λbg, we then introduce a probabilistic thresholding method, where, for the first time, the fraction of misclassified pixels can be determined a priori for a general image in an unsupervised way. We use synthetic images to validate our a priori estimates and to benchmark against the Otsu method, which is a popular unsupervised non-probabilistic image thresholding method (no a priori estimates for the error rates are provided). For completeness, we lastly present a simple heuristic general-purpose segmentation method based on the thresholding results, which we apply to segmentation of synthetic images and experimental images of fluorescent beads and lung cell nuclei. Our publicly available software opens up for fully automated, unsupervised, probabilistic photophysical image analysis.


Subject(s)
Diagnostic Imaging , Electrons , Image Processing, Computer-Assisted/methods , Fourier Analysis
2.
Micromachines (Basel) ; 15(2)2024 Feb 13.
Article in English | MEDLINE | ID: mdl-38398996

ABSTRACT

Regular device-scale DNA waves for high DNA concentrations and flow velocities have been shown to emerge in quadratic micropillar arrays with potentially strong relevance for a wide range of microfluidic applications. Hexagonal arrays constitute another geometry that is especially relevant for the microfluidic pulsed-field separation of DNA. Here, we report on the differences at the micro and macroscopic scales between the resulting wave patterns for these two regular array geometries and one disordered array geometry. In contrast to the large-scale regular waves visible in the quadratic array, in the hexagonal arrays, waves occur in a device-scale disordered zig-zag pattern with fluctuations on a much smaller scale. We connect the large-scale pattern to the microscopic flow and observe flow synchronization that switches between two directions for both the quadratic and hexagonal arrays. We show the importance of order using the disordered array, where steady-state stationary and highly fluctuating flow states persist in seemingly random locations across the array. We compare the flow dynamics of the arrays to that in a device with sparsely distributed pillars. Here, we observe similar vortex shedding, which is clearly observable in the quadratic and disordered arrays. However, the shedding of these vortices couples only in the flow direction and not laterally as in the dense, ordered arrays. We believe that our findings will contribute to the understanding of elastic flow dynamics in pillar arrays, helping us elucidate the fundamental principles of non-Newtonian fluid flow in complex environments as well as supporting applications in engineering involving e.g., transport, sorting, and mixing of complex fluids.

3.
RSC Adv ; 13(45): 31497-31506, 2023 Oct 26.
Article in English | MEDLINE | ID: mdl-37901264

ABSTRACT

Solutions of macromolecules exhibit viscoelastic properties and unlike Newtonian fluids, they may break time-reversal symmetry at low Reynolds numbers resulting in elastic turbulence. Furthermore, under some conditions, instead of the chaotic turbulence, the result is large-scale waves in the form of cyclic spatial and temporal concentration variations, as has been shown for macromolecular DNA flowing in microfluidic pillar arrays. We here demonstrate how altering the symmetry of the individual pillars can be used to influence the symmetry of these waves. We control the extent of instabilities in viscoelastic flow by leveraging the effects of the symmetry of the pillars on the waves, demonstrating suppressed viscoelastic fluctuations with relevance for transport and sorting applications, or conversely opening up for enhanced viscoelasticity-mediated mixing. The onset of waves, which changes flow resistance, occurs at different Deborah numbers for flow in different directions through the array of triangular pillars, thus breaking the symmetry of the flow resistance along the device, opening up for using the occurrence of the waves to construct a fluidic diode.

4.
Lab Chip ; 23(7): 1779-1793, 2023 03 28.
Article in English | MEDLINE | ID: mdl-36807458

ABSTRACT

We observe regular patterns emerging across multiple length scales with high-concentration DNA solutions in microfluidic pillar arrays at low Reynolds numbers and high Deborah numbers. Interacting vortices between pillars lead to long-range order in the form of large travelling waves consisting of DNA at high concentration and extension. Waves are formed in quadratic arrays of pillars, while randomizing the position of the pillar in each unit cell of a quadratic array leads to suppression of the long-range patterns. We find that concentrations exceeding the overlap concentration of the DNA enables the waves, and exploring the behavior of the waves as a function of flow rate, buffer composition, concentration and molecular length, we identify elastic effects as central to the origin of the waves. Our work may not only help increase the low throughput that often limits sample processing in microfluidics, it may also provide a platform for further studies of the underlying viscoelastic mechanisms.


Subject(s)
DNA , Microfluidics
5.
Micromachines (Basel) ; 13(10)2022 Oct 17.
Article in English | MEDLINE | ID: mdl-36296107

ABSTRACT

Length-based separation of DNA remains as relevant today as when gel electrophoresis was introduced almost 100 years ago. While new, long-read genomics technologies have revolutionised accessibility to powerful genomic data, the preparation of samples has not proceeded at the same pace, with sample preparation often constituting a considerable bottleneck, both in time and difficulty. Microfluidics holds great potential for automated, sample-to-answer analysis via the integration of preparatory and analytical steps, but for this to be fully realised, more versatile, powerful and integrable unit operations, such as separation, are essential. We demonstrate the displacement and separation of DNA with a throughput that is one to five orders of magnitude greater than other microfluidic techniques. Using a device with a small footprint (23 mm × 0.5 mm), and with feature sizes in the micrometre range, it is considerably easier to fabricate than parallelized nano-array-based approaches. We show the separation of 48.5 kbp and 166 kbp DNA strands achieving a significantly improved throughput of 760 ng/h, compared to previous work and the separation of low concentrations of 48.5 kbp DNA molecules from a massive background of sub 10 kbp fragments. We show that the extension of DNA molecules at high flow velocities, generally believed to make the length-based separation of long DNA difficult, does not place the ultimate limitation on our method. Instead, we explore the effects of polymer rotations and intermolecular interactions at extremely high DNA concentrations and postulate that these may have both negative and positive influences on the separation depending on the detailed experimental conditions.

SELECTION OF CITATIONS