Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Neuroradiol J ; 36(1): 23-30, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35507423

ABSTRACT

BACKGROUND AND PURPOSE: To determine the prevalence of vertebral hemangiomas (VHs), establish a new classification of VHs based on their MRI-signal pattern, and study their natural history. METHODS: MRI of 1000 consecutive patients who underwent at least two MRI with an interval of at least 3 years. Growth rate and change of MRI-signal pattern during the follow-up period were the parameters included in studying the natural history of VHs. RESULTS: The prevalence of VHs was 41%. VHs were classified as type I-IV with fat-rich VHs (type I), constituted 79% of all VHs. VHs were more common among females 43% versus males 39%, p = .22. The most affected vertebra was L1. Occurrence rates for cervical (1%), thoracic (7%), and lumbar spine (10%) differed significantly (p < .001). The prevalence of VHs increased with age regardless of gender or spinal part involved (p < .001). Only 26% of VHs changed their size and 4% changed their signal during the average follow-up of 7 years. All VHs were slowly growing lesions (average expected growth of <3 mm/10 years). No significant difference between growth rate of VHs type I (0.25 mm/year) and other types of VHs. None of the VHs that were initially reported as "metastases cannot be rule out" showed alarming change in signal or size. CONCLUSIONS: VH can be classified into four types based on their MRI-signal pattern. Regardless of their type, VHs are slowly growing lesions. The presence of typical morphological pattern should enable radiologists to confidently differentiate them from vertebral metastases.


Subject(s)
Hemangioma , Spinal Neoplasms , Male , Female , Humans , Retrospective Studies , Prevalence , Longitudinal Studies , Spinal Neoplasms/pathology , Magnetic Resonance Imaging , Hemangioma/pathology
2.
BMC Med Imaging ; 11: 8, 2011 Apr 05.
Article in English | MEDLINE | ID: mdl-21466703

ABSTRACT

BACKGROUND: We have previously proposed the use of Doppler ultrasound to non-invasively stage sinus infection, as we showed that acoustic streaming could be generated in nonpurulent sinus secretions and helped to distinguish it from mucopurulent sinus secretions. In order to continue this development of a clinically applicable Doppler equipment, we need to determine different dimensions of the paranasal sinuses, especially the thickness of the anterior wall of the maxillary sinus (at the canine fossa). To the best of our knowledge, this is the first report on the thickness of the canine fossa. This study aimed to (a) estimate different dimensions of the maxillary and frontal sinuses measured on computed tomography (CT) of the head, (b) define cut-off values for the normal upper and lower limits of the different measured structures, (c) determine differences in age, side and gender, (d) compare manually and automatically estimated maxillary sinuses volumes, and (e) present incidental findings in the paranasal sinuses among the study patients. METHODS: Dimensions of 120 maxillary and frontal sinuses from head CTs were measured independently by two radiologists. RESULTS: The mean value of the maxillary sinus volume was 15.7±5.3 cm3 and significantly larger in males than in females (P=0.004). There was no statistically significant correlation between the volume of maxillary sinuses with age or side. The mean value of the bone thickness at the canine fossa was 1.1±0.4 mm. The automatically estimated volume of the maxillary sinuses was 14-17% higher than the calculated volume. There was high interobserver agreement with regard to the different measurements performed in this study. Different types of incidental findings of the paranasal sinuses were found in 35% of the patients. CONCLUSION: We presented different dimensions of the maxillary and frontal sinuses on CTs. We believe that our data are necessary for further development of a clinically applicable Doppler equipment for staging rhinosinusitis.


Subject(s)
Frontal Sinus/diagnostic imaging , Maxillary Sinus/diagnostic imaging , Paranasal Sinus Diseases/diagnostic imaging , Tomography, X-Ray Computed/methods , Adolescent , Adult , Aged , Female , Humans , Male , Middle Aged , Radiology Information Systems , Reproducibility of Results , Retrospective Studies , Statistics, Nonparametric
3.
Am J Otolaryngol ; 32(1): 47-51, 2011.
Article in English | MEDLINE | ID: mdl-20015806

ABSTRACT

PURPOSE: The study aimed to (1) optimize the radiation doses of computed tomography (CT) of paranasal sinuses, (2) compare the radiation doses of different CT protocols with that of plain radiography, and (3) evaluate the reliability of low-dose CT in the detection of pathology and characterization of the detected pathology. MATERIALS AND METHODS: A head phantom was examined with different scan parameters to define a cutoff value to which the radiation dose can be reduced without negative impact on image quality. Kruskal-Wallis test and Wilcoxon W test were performed to compare the effective doses of the plain radiography in 30 patients with that of 3 different CT protocols in a total of 90 patients. The interobserver and intraobserver agreement in the detection of pathologic findings and in characterization of the pathology was estimated by calculating κ value. RESULTS: The effective doses of plain radiography and low-dose CT were 0.098 and 0.045 mSv, respectively (P < .001). The effective dose of standard CT of sinuses (0.371 mSv) was 3.8 times higher than that of plain radiography and 8.2 times higher than that of low-dose CT (P < .001). The interobserver and intraobserver agreement on CT with regard to detection of pathology and pathology characterization was almost perfect (κ values 0.81-1) compared to fair (κ values 0.38-0.39) in plain radiography. CONCLUSIONS: The here proposed low-dose CT means significant dose reduction and is a reliable method in the investigation of the paranasal sinuses.


Subject(s)
Paranasal Sinuses/diagnostic imaging , Tomography, X-Ray Computed/methods , Female , Humans , Male , Middle Aged , Phantoms, Imaging , Radiation Dosage , Reproducibility of Results , Retrospective Studies , Statistics, Nonparametric
4.
Eur Spine J ; 19(1): 96-104, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19888607

ABSTRACT

Posterior corrective surgery using "all pedicle screw construct" carries risk of neurovascular complications. The study aims were to assess the screw placement in patients with adolescent idiopathic scoliosis using CT with low-radiation dose, and to evaluate the clinical outcome in patients with misplaced pedicle screws. CTs of 49 consecutive patients (873 screws, 79% thoracic) were retrospectively evaluated by two independent radiologists. A new grading system was developed to distinguish between lateral, medial and anterior cortical perforations, endplate perforation and foraminal perforation. The grading system is based on whether the cortical violation is partial or total rather than on mm-basis. The overall rate of screw misplacement was 17% (n = 149): 8% were laterally placed and 6.1% were medially placed. The rates of anterior cortical, endplate and foraminal perforation were 1.5, 0.9, and 0.5%, respectively. Lateral cortical perforation was more frequent in the thoracic spine (P = 0.005), whereas other types of misplacement including medial cortical perforation were more frequent on the left and the concave side of scoliotic curves (P = 0.002 and 0.003). No neurovascular complications were reported. The association between the occurrence of screw misplacement and the Cobb angle was statistically significant (P = 0.037). Misplacements exceeding half screw diameter should be classified as unacceptable. Low-dose CT implies exposing these young individuals to a significantly lower radiation dose than do other protocols used in daily clinical practice. We recommend using low-dose CT and the grading system proposed here in the postoperative assessment of screw placement.


Subject(s)
Bone Screws/standards , Outcome Assessment, Health Care/methods , Scoliosis/diagnostic imaging , Scoliosis/surgery , Spinal Fusion/methods , Tomography, X-Ray Computed/methods , Adolescent , Bone Screws/adverse effects , Female , Humans , Iatrogenic Disease/prevention & control , Male , Postoperative Complications/diagnostic imaging , Postoperative Complications/epidemiology , Postoperative Complications/prevention & control , Radiation Dosage , Retrospective Studies , Spinal Fusion/adverse effects , Spinal Fusion/instrumentation , Thoracic Vertebrae/diagnostic imaging , Thoracic Vertebrae/pathology , Thoracic Vertebrae/surgery , Treatment Outcome , Young Adult
5.
Spine (Phila Pa 1976) ; 34(9): 941-8, 2009 Apr 20.
Article in English | MEDLINE | ID: mdl-19532002

ABSTRACT

STUDY DESIGN: A retrospective study. OBJECTIVE: To evaluate the reliability of computed tomography (CT) with low radiation dose in the assessment of implant status in patients with adolescent idiopathic scoliosis (AIS). SUMMARY OF BACKGROUND DATA: The use of all-pedicle screw construct in scoliosis corrective surgery continues to gain increasing popularity since their introduction 1994 although their use in the thoracic spine carries a potential risk for neurovascular complications. CT is the method widely used to evaluate screw placement. METHODS: Retrospective analysis of 46 consecutive low-dose spine CT in patients with AIS after posterior corrective surgery. Status of 809 titanium screws (642 thoracic) was evaluated. The degree of interobserver and intraobserver agreements about implant status was used as an indicator of the reliability of the low-dose spine CT in the assessment of accuracy of pedicle screw insertion. A new grading system has been developed for this purpose. Five types of misplacement have been evaluated: lateral, medial, and anterior cortical perforations; endplate perforation; and foraminal perforation. RESULTS: The analysis has shown a substantial interobserver and intraobserver agreements (kappa: 0.69 and 0.76, respectively) in differentiating pedicle screws with acceptable placement from screws with partial or total cortical perforation. None of the examinations was subjectively classified as unreliable. CONCLUSION: The study has shown that low-dose spine CT is a reliable method in evaluating screw placement in patients with AIS after posterior scoliosis surgery with titanium implants, using the here proposed grading system. The new grading system of screw misplacement was feasible and in line with the general agreement about the harmlessness of misplacement with minor pedicle breach. The reliability of low-dose spine CT in evaluation of lateral and medial cortical perforations was substantial. To reduce the radiation load, the postoperative assessment of titanium implants should be performed with low-dose CT.


Subject(s)
Bone Screws , Orthopedic Procedures/methods , Scoliosis/surgery , Tomography, X-Ray Computed/methods , Adolescent , Humans , Observer Variation , Orthopedic Procedures/instrumentation , Radiation Dosage , Reproducibility of Results , Retrospective Studies , Scoliosis/diagnostic imaging , Spinal Fusion/instrumentation , Spinal Fusion/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...