Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Int J Dent Hyg ; 2024 Jun 11.
Article in English | MEDLINE | ID: mdl-38863249

ABSTRACT

OBJECTIVE: The objective of this long-term clinical study was to evaluate the influence of a newly developed powered toothbrush (PT) on the size and number of pre-existing gingival recessions (GR) in comparison to a manual toothbrush (MT). METHODS: This was a prospective, single-blind, parallel-group, randomized controlled clinical study. Participants without periodontitis, but with at least two teeth (index teeth) showing GR ≥2 mm were randomized to brush either twice daily with a MT or with a PT with a linear magnetic drive causing the round brush head to produce gentle micro vibrations along with oscillating-rotating movements. Primary outcome parameter was the mean change of GR at the index teeth over 36 months. RESULTS: Totally 87 out of 92 participants completed the study (MT/PT: n = 42/n = 45). At the 36-month evaluation the mean (standard deviation) change of GR at index teeth differed significantly between MT 0.17 (0.77) and PT -0.10 (0.63) (p = 0.013). Furthermore, the amount of GR sites which improved ≥1 mm or remained stable during the study period did not differ between MT and PT, but the number of sites worsened ≥1 mm was significantly in favour for PT (MT 23 (25.5%) versus PT 10 (10.6%); p = 0.009). A binary logistic regression identified tooth type (OR = 2.991 for pre-/molar (1.096 [95% CI 1.002-8.933]; p = 0.050)) and manual brushing (OR = 3.341 (1.206 [95% CI 1291-8648]; p = 0.013)) as risk factors for recession impairment at the index teeth. There were no differences between groups for adverse events. CONCLUSION: In a population with pre-existing gingival recessions and consequently a high risk of developing further recession the PT seems to be favourable with regard to further development of GR.

2.
BMC Oral Health ; 24(1): 404, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38553668

ABSTRACT

BACKGROUND: Up to date, interdental brushes (IDB) are the first choice for interdental cleaning because of their cleaning efficacy. Cylindrical ones must be selected individually according to the size/morphology of the interdental area (IDR), whereas conical ones cover a larger variability of IDR. However, there is a trend on the part of patients towards interdental rubber picks (IRP) which are in general conically shaped, and which seem to be linked with lower cleaning efficacy. A new IRP with an Archimedes´ screw design was developed to overcome this limitation. Therefore, the in vitro study aimed to measure the experimental cleaning efficacy (ECE) and force (ECF) during interdental use of IDBs versus the new IRP type. METHODS: Three IRPs with different tapers (PHB angled: 0.039, PHB straight S: 0.027, Vitis straight M: 0.045; all Flexipicks, Dentaid, Cerdanyola del Vallès, Spain) were compared to one IDB (Interprox micro PHD 0.9, Dentaid, Cerdanyola del Vallès, Spain). IDR were reproduced by a 3D-printer (Form2, Formlabs Sommerville, MA, USA) according to human teeth and matched to equivalent pairs (isosceles triangle, concave, convex) in three different diameters (1.0 mm,1.1 mm,1.3 mm). Covered with simulated biofilm, pre-/ post-brushing situations of IDR (standardized, computer-aided ten cycles) were photographed and quantified by digital image subtraction to calculate ECE [%]. ECF were registered with a load cell [N]. Statistically significant differences were detected using the Mann-Whitney-U-test and the Kruskal-Wallis-test with Bonferroni correction for multiple testing. RESULTS: Overall, the ECE (mean ± SD) was higher for IDB micro 0.9 (45.95 ± 11.34%, p < 0.001) compared to all IRPs (PHB angled: 25.37 ± 15.29%; PHB straight: 22.28 ± 16.75%; Vitis straight: 25.24 ± 12.21%; p ≤ 0.001), whereat best ECE was achieved in isosceles triangle IDR of 1.0-1.1 mm (IDB micro 0.9: 70.7 ± 7.7%; PHB angled S: 57.30 ± 4.43%; p < 0.001). The highest ECF occurred for Vitis straight M with 2.11 ± 0.46 N, while IDB micro 0.9 showed lowest ECF values (0.64 ± 0.14 N; p < 0.001). CONCLUSIONS: IRP with an Archimedes´ screw design and a higher taper were associated with advanced ECE but also higher ECF, nevertheless, ECE didn't reach the cleaning efficacy of conventional IDBs.


Subject(s)
Dental Devices, Home Care , Dental Plaque , Humans , Rubber , Toothbrushing/methods , Bone Screws
3.
Clin Oral Investig ; 26(9): 5687-5696, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35536440

ABSTRACT

OBJECTIVES: SOPs recommend high-volume evacuation (HVE) for aerosol-generating procedures (AGPs) in dentistry. Therefore, in the exploratory study, the area of splatter contamination (SCON in %) generated by high-speed tooth preparation (HSP) and air-polishing (APD) was measured when different suction cannulas of 6 mm diameter (saliva ejector (SAE)), 11 mm (HC11), or 16 mm (HC16) were utilized versus no-suction (NS). MATERIALS AND METHODS: Eighty tests were performed in a closed darkened room to measure SCON (1m circular around the manikin head (3.14 m2) via plan metrically assessment through fluorescence technique. HSP (handpiece, turbine (Kavo, Germany)) or APD (LM-ProPowerTM (Finland), Airflow®-Prophylaxis-Master (Switzerland)) for 6 min plus 5 s post-treatment were performed either without suction or with low-flow (150 l/min for SAE) or high-flow rate (250 l/min/350 l/min for HC11/HC16) suction. All tests were two-tailed (p≤0.05, Bonferroni corrected for multi-testing). RESULTS: Irrespective the AGP, SCON was higher for NS (median [25th; 75th percentiles]: 3.4% [2.6; 5.4]) versus high-flow suction (1.9% [1.5; 2.5]) (p=0.002). Low-flow suction (3.5% [2.6; 4.3]) versus NS resulted in slightly lower but not statistically significantly lower SCON (p=1.000) and was less effective than high-flow suction (p=0.003). Lowest contamination values were found with HC16 (1.9% [1.5; 2.5]; p≤0.002), whereat no significant differences were found for HC11 (2.4% [1.7; 3.1]) compared to SAE (p=0.385) or NS (p=0.316). CONCLUSIONS: Within study's limitations, the lowest splatter contamination values resulted when HC16 were utilized by a high-flow rate of ≥250 l/min. CLINICAL RELEVANCE: It is strongly recommended to utilize an HVE with suction cannulas of 16mm diameter for a high-flow rate during all AGPs and afterwards also to disinfect all surface of patients or operators contacted.


Subject(s)
Cannula , Dentistry , Suction , Tooth Preparation , Aerosols , Finland , Humans , Suction/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...