Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Mol Diagn ; 2023 Aug 05.
Article in English | MEDLINE | ID: mdl-37544360

ABSTRACT

Microsatellite instability (MSI) is an evolving biomarker for cancer detection and treatment. MSI was first used to identify patients with Lynch syndrome, a hereditary form of colorectal cancer (CRC), but has recently become indispensable in predicting patient response to immunotherapy. To address the need for pan-cancer MSI detection, a new multiplex assay was developed that uses novel long mononucleotide repeat (LMR) markers to improve sensitivity. A total of 469 tumor samples from 20 different cancer types, including 319 from patients with Lynch syndrome, were tested for MSI using the new LMR MSI Analysis System. Results were validated by using deficient mismatch repair (dMMR) status according to immunohistochemistry as the reference standard and compared versus the Promega pentaplex MSI panel. The sensitivity of the LMR panel for detection of dMMR status by immunohistochemistry was 99% for CRC and 96% for non-CRC. The overall percent agreement between the LMR and Promega pentaplex panels was 99% for CRC and 89% for non-CRC tumors. An increased number of unstable markers and the larger size shifts observed in dMMR tumors using the LMR panel increased confidence in MSI determinations. The LMR MSI Analysis System expands the spectrum of cancer types in which MSI can be accurately detected.

2.
PLoS One ; 15(12): e0243747, 2020.
Article in English | MEDLINE | ID: mdl-33315907

ABSTRACT

Firefly luciferase-based ATP detection assays are frequently used as a sensitive, cost-efficient method for monitoring hygiene in many industrial settings. Solutions of detection reagent, containing a mixture of a substrate and luciferase enzyme that produces photons in the presence of ATP, are relatively unstable and maintain only a limited shelf life even under refrigerated conditions. It is therefore common for the individual performing a hygiene test to manually prepare fresh reagent at the time of monitoring. To simplify sample processing, a liquid detection reagent with improved thermal stability is needed. The engineered firefly luciferase, Ultra-Glo™, fulfills one aspect of this need and has been valuable for hygiene monitoring because of its high resistance to chemical and thermal inactivation. However, solutions containing both Ultra-Glo™ luciferase and its substrate luciferin gradually lose the ability to effectively detect ATP over time. We demonstrate here that dehydroluciferin, a prevalent oxidative breakdown product of luciferin, is a potent inhibitor of Ultra-Glo™ luciferase and that its formation in the detection reagent is responsible for the decreased ability to detect ATP. We subsequently found that dialkylation at the 5-position of luciferin (e.g., 5,5-dimethylluciferin) prevents degradation to dehydroluciferin and improves substrate thermostability in solution. However, since 5,5-dialkylluciferins are poorly utilized by Ultra-Glo™ luciferase as substrates, we used structural optimization of the luciferin dialkyl modification and protein engineering of Ultra-Glo™ to develop a luciferase/luciferin pair that shows improved total reagent stability in solution at ambient temperature. The results of our studies outline a novel luciferase/luciferin system that could serve as foundations for the next generation of bioluminescence ATP detection assays with desirable reagent stability.


Subject(s)
Firefly Luciferin/chemistry , Luminescent Agents/chemistry , Luminescent Measurements/methods , Adenosine Triphosphate/chemistry , Alkylation , Indicators and Reagents , Luciferases, Firefly/chemistry , Substrate Specificity , Temperature
3.
Anal Chem ; 87(23): 11635-40, 2015 Dec 01.
Article in English | MEDLINE | ID: mdl-26537636

ABSTRACT

We present a novel proteomic standard for assessing liquid chromatography-tandem mass spectrometry (LC-MS/MS) instrument performance, in terms of chromatographic reproducibility and dynamic range within a single LC-MS/MS injection. The peptide mixture standard consists of six peptides that were specifically synthesized to cover a wide range of hydrophobicities (grand average hydropathy (GRAVY) scores of -0.6 to 1.9). A combination of stable isotope labeled amino acids ((13)C and (15)N) were inserted to create five isotopologues. By combining these isotopologues at different ratios, they span four orders of magnitude within each distinct peptide sequence. Each peptide, from lightest to heaviest, increases in abundance by a factor of 10. We evaluate several metrics on our quadrupole orbitrap instrument using the 6 × 5 LC-MS/MS reference mixture spiked into a complex lysate background as a function of dynamic range, including mass measurement accuracy (MMA) and the linear range of quantitation of MS1 and parallel reaction monitoring experiments. Detection and linearity of the instrument routinely spanned three orders of magnitude across the gradient (500 fmol to 0.5 fmol on column) and no systematic trend was observed for MMA of targeted peptides as a function of abundance by analysis of variance analysis (p = 0.17). Detection and linearity of the fifth isotopologue (i.e., 0.05 fmol on column) was dependent on the peptide and instrument scan type (MS1 vs PRM). We foresee that this standard will serve as a powerful method to conduct both intra-instrument performance monitoring/evaluation, technology development, and inter-instrument comparisons.


Subject(s)
Chromatography, Liquid/methods , Indicators and Reagents/chemistry , Peptides/chemistry , Proteomics/methods , Tandem Mass Spectrometry/methods , Amino Acids/chemistry , HEK293 Cells , Humans , Hydrophobic and Hydrophilic Interactions , Peptides/chemical synthesis
4.
Int J Cancer ; 132(11): 2510-9, 2013 Jun 01.
Article in English | MEDLINE | ID: mdl-23136038

ABSTRACT

Continuous human cell lines have been used extensively as models for biomedical research. In working with these cell lines, researchers are often unaware of the risk of cross-contamination and other causes of misidentification. To reduce this risk, there is a pressing need to authenticate cell lines, comparing the sample handled in the laboratory to a previously tested sample. The American Type Culture Collection Standards Development Organization Workgroup ASN-0002 has developed a Standard for human cell line authentication, recommending short tandem repeat (STR) profiling for authentication of human cell lines. However, there are known limitations to the technique when applied to cultured samples, including possible genetic drift with passage. In our study, a dataset of 2,279 STR profiles from four cell banks was used to assess the effectiveness of the match criteria recommended within the Standard. Of these 2,279 STR profiles, 1,157 were grouped into sets of related cell lines-duplicate holdings, legitimately related samples or misidentified cell lines. Eight core STR loci plus amelogenin were used to unequivocally authenticate 98% of these related sets. Two simple match algorithms each clearly discriminated between related and unrelated samples, with separation between related samples at ≥80% match and unrelated samples at <50% match. A small degree of overlap was noted at 50-79% match, mostly from cell lines known to display variable STR profiles. These match criteria are recommended as a simple and effective way to interpret results from STR profiling of human cell lines.


Subject(s)
Algorithms , Gene Expression Profiling/methods , Genotyping Techniques/standards , Microsatellite Repeats/genetics , Cell Line , Humans , Polymerase Chain Reaction
SELECTION OF CITATIONS
SEARCH DETAIL
...