1.
J Appl Lab Med ; 6(2): 378-386, 2021 03 01.
Article in English | MEDLINE | ID: mdl-32995844

ABSTRACT

INTRODUCTION: When monitoring heparin, anti-Xa assays are susceptible to interference from apixaban taken before admission and can result in inappropriate dose adjustments that can negatively affect patient care. METHODS: We derived a novel assay, termed corrected heparin (CH), using quantified values from a chromogenic anti-Xa assay with heparin calibrators before and after heparinase treatment to eliminate any interference from apixaban within the patient sample. We retrospectively assessed 469 specimens from 72 patients at our institution who had their unfractionated heparin infusion monitored using the CH assay because of known apixaban use. These patients were included in the study if they had detectable apixaban levels (>0.1 IU/mL by anti-Xa). RESULTS: The analytical performance of the assay was evaluated, and precision was found to be 8.8% within 1 day and 13.3% over multiple days, with acceptable linearity (R2 = 0.997). Evaluation of clinical performance was compared with the partial thromboplastin time (PTT), showing a lack of correlation similar to comparisons between the PTT and anti-Xa assay (Blood Coagul Fibrinolysis 1993;4:635-8). The mean time to a therapeutic result in this cohort was 10 hours and 10 minutes. The CH assay was used to determine how long the apixaban was detected by the anti-Xa assay. The majority of patients (80%) still had measurable anti-Xa assay interference from apixaban at 24 hours after the last apixaban dose. CONCLUSIONS: We have developed and evaluated an assay capable of quantifying heparin in the presence of apixaban. This assay showed acceptable performance in both analytical and clinical performance.


Subject(s)
Heparin , Laboratories , Anticoagulants/adverse effects , Factor Xa Inhibitors , Heparin/adverse effects , Hospitals , Humans , Pyrazoles , Pyridones , Retrospective Studies
2.
Clin Chim Acta ; 485: 272-274, 2018 Oct.
Article in English | MEDLINE | ID: mdl-29958892

ABSTRACT

BACKGROUND: Vitamin K is a vital component within both the intrinsic and extrinsic coagulation cascade as certain factors (II, VII, IX, X and protein C and S) utilize vitamin K as a cofactor during post translational modification. Deficiency of vitamin K can result in the inability to properly form blood clots, both in vivo and in vitro, due to reduced vitamin K dependent factor levels and function. Vitamin K deficiency can result from congenital causes, such as VKOR or CYP2C9 mutations, or acquired causes, such as nutritional deficiencies, antibiotic therapy, or supra-therapeutic warfarin dosing. RESULTS: In this case we present a patient with multifactorial vitamin K deficiency (due to nutritional defects and multiple genetic mutations in VKOR and CYP2C9) that was exacerbated by antibiotic and warfarin therapy during her hospital admission. CONCLUSION: This case displays the importance of genetic testing prior to warfarin dosing and the role antibiotics play in the coagulation cascade.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Anticoagulants/therapeutic use , Thrombosis/drug therapy , Vitamin K Deficiency/drug therapy , Warfarin/therapeutic use , Aged , Automation, Laboratory , Blood Coagulation/drug effects , Female , Humans
3.
Clin Chim Acta ; 476: 67-74, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29154790

ABSTRACT

BACKGROUND: Unrecognized hemoglobinopathies can lead to measured hemoglobin A1c (Hb A1c) concentrations that are erroneous or misleading. We determined the effects of rare hemoglobin variants on capillary electrophoresis (CE) and HPLC methods for measurement of Hb A1c. METHODS: We prospectively investigated samples in which Hb A1c was measured by CE during a 14-month period. For samples in which the electropherograms suggested the presence of rare hemoglobinopathies, hemoglobin variants were identified by molecular analysis or by comparison with electropherograms of known variants. When sample volume permitted, Hb A1c was measured by 2 HPLC measurement procedures and by boronate affinity HPLC. RESULTS: Hb A1c was measured by CE in 33,859 samples from 26,850 patients. 15 patients (0.06%) were identified as having rare hemoglobinopathies: Hbs A2 prime, Agenogi, Fannin-Lubbock I, G Philadelphia, G San Jose, J Baltimore, La Desirade, N Baltimore, Nouakchott, and Roanne. Among 6 of these samples tested by 2 ion-exchange HPLC methods, the rare Hb was detected by both HPLC methods in only one sample, and none were detected by boronate affinity HPLC. The mean of the Hb A1c results of 2 HPLC methods differed from the result of the CE method by 0.7-2.2% Hb A1c in samples with variant hemoglobins versus <0.2% Hb A1c in samples without variants. CONCLUSION: Measurement procedures differ in the ability to detect the presence of rare Hb variants and to quantify Hb A1c in patients who harbor such variants.


Subject(s)
Glycated Hemoglobin/genetics , Hemoglobins, Abnormal/genetics , Chromatography, High Pressure Liquid , Electrophoresis, Capillary , Genetic Variation/genetics , Glycated Hemoglobin/analysis , Hemoglobins, Abnormal/analysis , Humans , Prospective Studies