Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Knee Surg Sports Traumatol Arthrosc ; 31(12): 5365-5380, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37747534

ABSTRACT

PURPOSE: In revision total knee arthroplasty (TKA) ligament instability and bone defects might require more constraint implants such as a condylar constrained knee (CCK) or rotating hinged knee (RHK). When both implants are suitable, the choice remains controversial. The purpose of this systematic review and meta-analysis was to compare the survivorship and clinical outcome between CCK and RHK in revision TKA. METHODS: Systematic literature research was performed. Studies analysing the clinical outcome and/or survivorship of CCK and/or RHK in revision TKA were included. Clinical outcomes included the Knee Society Score, both clinical (KSCS) and functional (KSFS), range of motion (ROM) and reoperations. Survival was defined as the time free from removal or revision of the femoral and/or tibial component. RESULTS: A total of 40 articles analysing 4.555 knees were included. Survival did not differ between RHK and CCK implants (p = 0.6058), with, respectively, 91.6% and 89.8% survival after 5 years. Postoperative KSCS and KSFS were, respectively, 79.2 (SD 10.7) and 61.1 (SD 21.8) for the CCK group. Similar scores were noted for the RHK group with a KSCS of 80.2 (SD 14.1) and KSFS of 58.5 (SD 17.3). Postoperative ROM was similar for CCK (105.3°, SD 17.1°) and RHK patients (104.1°, SD 16.9°). CONCLUSION: This meta-analysis revealed that both survivorship and clinical outcome are similar for CCK and RHK patients for whom both designs are technically suitable and indicated. LEVEL OF EVIDENCE: IV.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Humans , Survivorship , Prosthesis Design , Knee Joint/surgery , Reoperation , Treatment Outcome , Retrospective Studies , Prosthesis Failure
2.
J Arthroplasty ; 38(6S): S374-S378, 2023 06.
Article in English | MEDLINE | ID: mdl-36828051

ABSTRACT

BACKGROUND: The accuracy, precision, and repeatability by which the tibial sagittal plane can be found with imageless technology is currently unknown. The purpose of this study was to identify any differences between imageless and image-based technology to define the sagittal plane of the tibia. METHODS: A computed tomography (CT) was obtained of 18 cadavers with the knee fully extended. The surgical trans-epicondylar axis and several tibial rotation references were acquired on the CT scan. After a medial parapatellar approach, the same anatomical landmarks were acquired in vivo. In the horizontal plane, the angle between the surgical trans-epicondylar axis and the tibial rotational axes was assessed. RESULTS: Highest accuracy was found for posterior cruciate ligament (PCL)-anterior cruciate ligament (ACL, -1.48°, standard deviation [SD] 13.64; imageless), tibial medial condyle (TMC)-tibial lateral condyle (TLC, 1.72°, SD 4.24; image-based), the ACL-medial border of tibial tuberosity (MTT, -2.89°, SD 18.86; image-based). Highest precision was acquired with image-based technology: TMC-TLC (SD 4.24), PCL-ACL (SD 5.86), and PCL-medial third of tibial tuberosity (M3TT, SD 7.10). Excellent intraobserver and interobserver correlation coefficients were observed with image-based technology: PCL-MTT, anterior medial condyle (AMC)-anterior lateral condyle (ALC), and TMC-TLC (Intraobserver and interobserver correlation coefficients 0.90-0.98). CONCLUSION: The tibial sagittal plane could be defined with highest accuracy, precision, and repeatability on a preoperative CT. Imageless methodology lacked the precision and repeatability of image-based technology. With the current pursuit of high accuracy and precision in total knee arthroplasty, the reference frame used to quantify implant position should be highly accurate and precise as well. LEVEL OF EVIDENCE: IV, Case Series.


Subject(s)
Posterior Cruciate Ligament , Tibia , Humans , Tibia/diagnostic imaging , Tibia/surgery , Knee Joint/diagnostic imaging , Knee Joint/surgery , Anterior Cruciate Ligament/surgery , Cadaver
3.
Br J Sports Med ; 57(14): 914-920, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36604156

ABSTRACT

OBJECTIVE: To examine the effects of autoregulated (AUTO) and non-autoregulated (NAUTO) blood flow restriction (BFR) application on adverse effects, performance, cardiovascular and perceptual responses during resistance exercise. METHODS: Fifty-six healthy participants underwent AUTO and NAUTO BFR resistance exercise in a randomised crossover design using a training session with fixed amount of repetitions and a training session until volitional failure. Cardiovascular parameters, rate of perceived effort (RPE), rate of perceived discomfort (RPD) and number of repetitions were investigated after training, while the presence of delayed onset muscle soreness (DOMS) was verified 24 hours post-session. Adverse events during or following training were also monitored. RESULTS: AUTO outperformed NAUTO in the failure protocol (p<0.001), while AUTO scored significantly lower for DOMS 24 hours after exercise (p<0.001). Perceptions of effort and discomfort were significantly higher in NAUTO compared with AUTO in both fixed (RPE: p=0.014, RPD: p<0.001) and failure protocol (RPE: p=0.028, RPD: p<0.001). Sixteen adverse events (7.14%) were recorded, with a sevenfold incidence in the fixed protocol for NAUTO compared with AUTO (NAUTO: n=7 vs AUTO: n=1) and five (NAUTO) vs three (AUTO) adverse events in the failure protocol. No significant differences in cardiovascular parameters were found comparing both pressure applications. CONCLUSION: Autoregulation appears to enhance safety and performance in both fixed and failure BFR-training protocols. AUTO BFR training did not seem to affect cardiovascular stress differently, but was associated with lower DOMS, perceived effort and discomfort compared with NAUTO. TRIAL REGISTRATION NUMBER: NCT04996680.


Subject(s)
Muscle, Skeletal , Resistance Training , Adult , Humans , Blood Flow Restriction Therapy , Homeostasis , Muscle, Skeletal/physiology , Myalgia/prevention & control , Regional Blood Flow/physiology , Resistance Training/methods , Cross-Over Studies
4.
Int Orthop ; 47(2): 503-509, 2023 02.
Article in English | MEDLINE | ID: mdl-36385186

ABSTRACT

PURPOSE: The assistance of robot technology is introduced into the operating theatre to improve the precision of a total knee arthroplasty. However, as with all new technology, new technology requires a learning curve to reach adequate proficiency. The primary aim of this study was to identify the learning curve of an imageless robotic system with standardised laxity testing. The secondary aim of this study was to evaluate the accuracy of the intra-operative coronal alignment during the learning curve. METHODS: A prospective study was performed on 30 patients undergoing robot-assisted total knee arthroplasty with an imageless robotic system (Corin, Massachusetts, USA) associated with a dedicated standardised laxity testing device. The learning curve of all surgical steps was assessed with intra-operative video monitoring. As comparison, the total surgical time of the last 30 patients receiving conventional total knee arthroplasty by the same surgeon and with the same implant was retrospectively assessed. Coronal lower limb alignment was evaluated pre- and post-operatively on standing full-leg radiographs. RESULTS: CUSUM (cumulative summation) analysis has shown inflexion points in multiple steps associated with robot-assisted surgery between one and 16 cases, which indicates the progression from the learning phase to the proficiency phase. The inflexion point for total operative time occurred after nine cases. Robot-assisted total knee surgery required significantly longer operative times than the conventional counterpart, with an average increase of 22 min. Post-operative limb and implant alignment was not influenced by a learning curve. CONCLUSION: The introduction of an imageless robotic system with standardised laxity assessment for total knee arthroplasty results in a learning curve of nine cases based on operative time. Compared to conventional surgery, the surgeon is not able to reach time neutrality with the robotic platform. There is no learning curve associated with coronal limb or implant alignment. This study enables orthopaedic surgeons to understand the implementation of this surgical system and its specific workflow into clinical practice.


Subject(s)
Arthroplasty, Replacement, Knee , Robotic Surgical Procedures , Robotics , Humans , Arthroplasty, Replacement, Knee/methods , Prospective Studies , Retrospective Studies , Robotic Surgical Procedures/methods , Knee Joint , Operative Time
5.
Animals (Basel) ; 10(6)2020 Jun 12.
Article in English | MEDLINE | ID: mdl-32545683

ABSTRACT

The aim of the current study was to investigate the simultaneous measurement of plasma p-aminohippuric acid (PAH) clearance as a potential marker to assess effective renal plasma flow (eRPF) and tubular secretion (TS), and the plasma clearance of iohexol (IOH) as a marker of the glomerular filtration rate in poultry species. The PAH was administered intravenously (IV) to broiler chickens, layers, turkeys, Muscovy ducks, and pigeons. Each animal received successively a single bolus dose of 10 mg PAH/kg bodyweight (BW) and 100 mg PAH/kg BW to assess the eRPF and TS, respectively. Simultaneously with both PAH administrations, a single IV bolus of 64.7 mg/kg BW of IOH was administered. A high linear correlation (R2 = 0.79) between eRPF, based on the clearance of the low dose of PAH, and BW was observed for the poultry species. The correlation between TS, based on the clearance of the high dose of PAH, and BW was moderate (R2 = 0.50). Finally, a moderate correlation (R2 = 0.68) was demonstrated between GFR and eRPF and between GFR and TS (R2 = 0.56). This presented pharmacokinetic approach of the simultaneous administration of IOH and PAH enabled a simultaneous evaluation of eRPF/TS and GFR, respectively, in different poultry species.

6.
Obes Surg ; 30(11): 4659-4664, 2020 11.
Article in English | MEDLINE | ID: mdl-32594466

ABSTRACT

Recent studies have indicated that patients with prior bariatric surgery (BS) are at risk for developing alcohol use disorder. We explored patient demographics and impact on liver disease severity in 11 patients with prior BS listed for transplantation due to alcoholic liver disease, and compared these with 177 patients without BS. BS patients were younger with a female predominance and presented with more severe decompensation. The timeframe between diagnosis, listing, and transplantation was significantly shorter in patients with prior BS. The incidence of post-transplant complications and 3-year survival rate was comparable. In conclusion, alcoholic liver disease with rapid decompensation may develop after BS, warranting rapid identification with referral to a transplant center. Attention should be paid to pre-surgery screening for alcohol overuse risk factors.


Subject(s)
Bariatric Surgery , Liver Diseases, Alcoholic , Liver Transplantation , Obesity, Morbid , Bariatric Surgery/adverse effects , Female , Humans , Liver Diseases, Alcoholic/epidemiology , Liver Diseases, Alcoholic/surgery , Male , Obesity, Morbid/surgery , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...