1.
J Am Chem Soc ; 135(3): 1102-9, 2013 Jan 23.
Article in English | MEDLINE | ID: mdl-23231786

ABSTRACT

Simultaneous monitoring of multiple molecular interactions and multiplexed detection of several diagnostic biomarkers at very low concentrations have become important issues in advanced biological and chemical sensing. Here we present an optically multiplexed six-color Förster resonance energy transfer (FRET) biosensor for simultaneous monitoring of five different individual binding events. We combined simultaneous FRET from one Tb complex to five different organic dyes measured in a filter-based time-resolved detection format with a sophisticated spectral crosstalk correction, which results in very efficient background suppression. The advantages and robustness of the multiplexed FRET sensor were exemplified by analyzing a 15-component lung cancer immunoassay involving 10 different antibodies and five different tumor markers in a single 50 µL human serum sample. The multiplexed biosensor offers clinically relevant detection limits in the low picomolar (ng/mL) concentration range for all five markers, thus providing an effective early screening tool for lung cancer with the possibility of distinguishing small-cell from non-small-cell lung carcinoma. This novel technology will open new doors for multiple biomarker diagnostics as well as multiplexed real-time imaging and spectroscopy.


Subject(s)
Biomarkers, Tumor/blood , Biosensing Techniques , Carcinoma, Non-Small-Cell Lung/diagnosis , Color , Fluorescence Resonance Energy Transfer , Lung Neoplasms/diagnosis , Small Cell Lung Carcinoma/diagnosis , Fluorescent Dyes/chemistry , Humans , Terbium/chemistry , Time Factors
2.
Sensors (Basel) ; 11(10): 9667-84, 2011.
Article in English | MEDLINE | ID: mdl-22163719

ABSTRACT

Förster resonance energy transfer (FRET) from luminescent terbium complexes (LTC) as donors to semiconductor quantum dots (QDs) as acceptors allows extraordinary large FRET efficiencies due to the long Förster distances afforded. Moreover, time-gated detection permits an efficient suppression of autofluorescent background leading to sub-picomolar detection limits even within multiplexed detection formats. These characteristics make FRET-systems with LTC and QDs excellent candidates for clinical diagnostics. So far, such proofs of principle for highly sensitive multiplexed biosensing have only been performed under optimized buffer conditions and interactions between real-life clinical media such as human serum or plasma and LTC-QD-FRET-systems have not yet been taken into account. Here we present an extensive spectroscopic analysis of absorption, excitation and emission spectra along with the luminescence decay times of both the single components as well as the assembled FRET-systems in TRIS-buffer, TRIS-buffer with 2% bovine serum albumin, and fresh human plasma. Moreover, we evaluated homogeneous LTC-QD FRET assays in QD conjugates assembled with either the well-known, specific biotin-streptavidin biological interaction or, alternatively, the metal-affinity coordination of histidine to zinc. In the case of conjugates assembled with biotin-streptavidin no significant interference with the optical and binding properties occurs whereas the histidine-zinc system appears to be affected by human plasma.


Subject(s)
Diagnostic Techniques and Procedures , Fluorescence Resonance Energy Transfer/methods , Optical Phenomena , Plasma/chemistry , Quantum Dots , Terbium/chemistry , Absorption , Animals , Biotin/metabolism , Buffers , Cattle , Histidine/metabolism , Humans , Kinetics , Limit of Detection , Protein Binding , Serum Albumin, Bovine/metabolism , Streptavidin/metabolism , Zinc/metabolism
SELECTION OF CITATIONS