Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Diabetes Technol Ther ; 25(10): 677-688, 2023 10.
Article in English | MEDLINE | ID: mdl-37578778

ABSTRACT

Introduction: Multiple daily injection insulin therapy frequently fails to meet hospital glycemic goals and is prone to hypoglycemia. Automated insulin delivery (AID) with remote glucose monitoring offers a solution to these shortcomings. Research Design and Methods: In a single-arm multicenter pilot trial, we tested the feasibility, safety, and effectiveness of the Omnipod 5 AID System with real-time continuous glucose monitoring (CGM) for up to 10 days in hospitalized patients with insulin-requiring diabetes on nonintensive care unit medical-surgical units. Primary endpoints included the proportion of time in automated mode and percent time-in-range (TIR 70-180 mg/dL) among participants with >48 h of CGM data. Safety endpoints included incidence of severe hypoglycemia and diabetes-related ketoacidosis (DKA). Additional glycemic endpoints, CGM accuracy, and patient satisfaction were also explored. Results: Twenty-two participants were enrolled; 18 used the system for a total of 96 days (mean 5.3 ± 3.1 days per patient), and 16 had sufficient CGM data required for analysis. Median percent time in automated mode was 95% (interquartile range 92%-98%) for the 18 system users, and the 16 participants with >48 h of CGM data achieved an overall TIR of 68% ± 16%, with 0.17% ± 0.3% time <70 mg/dL and 0.06% ± 0.2% time <54 mg/dL. Sensor mean glucose was 167 ± 21 mg/dL. There were no DKA or severe hypoglycemic events. All participants reported satisfaction with the system at study end. Conclusions: The use of AID with a disposable tubeless patch-pump along with remote real-time CGM is feasible in the hospital setting. These results warrant further investigation in randomized trials.


Subject(s)
Diabetes Mellitus, Type 1 , Diabetic Ketoacidosis , Hypoglycemia , Humans , Blood Glucose , Blood Glucose Self-Monitoring/methods , Diabetes Mellitus, Type 1/drug therapy , Feasibility Studies , Hypoglycemia/chemically induced , Hypoglycemia/prevention & control , Hypoglycemic Agents/therapeutic use , Insulin/therapeutic use , Insulin Infusion Systems , Insulin, Regular, Human/therapeutic use , Pilot Projects
2.
Diabetes Care ; 45(7): 1666-1669, 2022 07 07.
Article in English | MEDLINE | ID: mdl-35485908

ABSTRACT

OBJECTIVE: Continuous glucose monitoring (CGM) improves diabetes management, but its reliability in individuals on hemodialysis is poorly understood and potentially affected by interstitial and intravascular volume variations. RESEARCH DESIGN AND METHODS: We assessed the accuracy of a factory-calibrated CGM by using venous blood glucose measurements (vBGM) during hemodialysis sessions and self-monitoring blood glucose (SMBG) at home. RESULTS: Twenty participants completed the protocol. The mean absolute relative difference of the CGM was 13.8% and 14.4%, when calculated on SMBG (n = 684) and on vBGM (n = 624), and 98.7% and 100% of values in the Parkes error grid A/B zones, respectively. Throughout 181 days of CGM monitoring, the median time in range (70-180 mg/dL) was 38.5% (interquartile range 29.3-57.9), with 28.7% (7.8-40.6) of the time >250 mg/dL. CONCLUSIONS: The overall performance of a factory-calibrated CGM appears reasonably accurate and clinically relevant for use in practice by individuals on hemodialysis and health professionals to improve diabetes management.


Subject(s)
Blood Glucose , Diabetes Mellitus, Type 1 , Blood Glucose Self-Monitoring/methods , Humans , Renal Dialysis , Reproducibility of Results
3.
J Endocr Soc ; 1(9): 1150-1155, 2017 Sep 01.
Article in English | MEDLINE | ID: mdl-29264569

ABSTRACT

Gestational primary hyperparathyroidism (GPHPT) is a rare condition with fewer than 200 cases reported. We present the case of a 21-year-old woman who presented at 10 weeks' gestation with severe hypercalcemia. Laboratory investigation was consistent with primary hyperparathyroidism. Neck ultrasound did not reveal any parathyroid enlargement. Due to the persistence of severe hypercalcemia, she was treated with 4 weeks of cinacalcet therapy, which was poorly tolerated due to nausea and vomiting. At 14 weeks' gestation, she underwent neck exploration with right lower, left upper, and partial right upper parathyroid gland excision. Intra- and postoperative parathyroid hormone (PTH) and calcium levels remained elevated. After a thorough discussion of risks/benefits, the patient requested further treatment. A parathyroid sestamibi scan (PSS) revealed an ectopic adenoma in the left mediastinum. The adenoma was removed via video-assisted thorascopic parathyroidectomy with intraoperative PTH declining to nearly undetectable levels. She ultimately delivered a physically and developmentally normal infant at 37 weeks' gestation. Appropriate treatment of severe GPHPT may prevent the maternal and fetal complications of hypercalcemia. This case, in which cinacalcet therapy and PSS were used, adds to the body of literature regarding treatment of severe GPHPT.

SELECTION OF CITATIONS
SEARCH DETAIL
...