Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Cardiovasc Dis ; 7(1): 83-89, 1980 Mar.
Article in English | MEDLINE | ID: mdl-15216286

ABSTRACT

Early ventricular fibrillation occurs in approximately 5% of patients admitted for acute myocardial infarction. Although late ventricular fibrillation (> 48 hours postinfarction) may occur in stable patients, it occurs more commonly when severe left ventricular power failure is present. We have encountered late ventricular fibrillation in three of 42 (7%) patients treated with intraaortic balloon pumping (IABP) for profound cardiogenic shock secondary to myocardial infarction. These patients progressed to our hemodynamic Class A prior to weaning, and were thought to be stable prior to IABP removal. They were the only ones who expired after achieving Class A status. The episodes of late ventricular fibrillation occurred after the patients had been successfully weaned from IABP and were free of arrhythmias. This experience suggests that prolonged antiarrhythmic therapy may be indicated for postinfarction patients who have had ventricular dysrhythmias during IABP support.

2.
Cardiovasc Dis ; 6(2): 173-180, 1979 Jun.
Article in English | MEDLINE | ID: mdl-15216321

ABSTRACT

A 21-year-old male patient underwent aortic and mitral valve replacement for progressive cardiac failure due to acute bacterial endocarditis. Ischemic myocardial contracture developed during attempts to restore cardiac activity following hypothermic, ischemic, cardioplegic arrest. An abdominal left ventricular assist device (ALVAD) was implanted and supported the circulation for nearly six days prior to cardiac transplantation. The preoperative EKG showed sinus tachycardia with left anterior hemiblock. Postoperatively, there was complete electromechanical dissociation. The postoperative EKG showed a superior and leftward shift of the axis. There was a marked loss of QRS voltage and variable degrees of atrioventricular block. At times, only P waves were present. On the fourth postoperative day, there was an axis shift to the extreme right. Prior to transplantation, sinus rhythm returned, and the axis shifted leftward once again. The common denominator of all the abnormal postoperative electrocardiograms was the conspicuous low voltage that probably signified early and extensive myocardial damage. To our knowledge, this is the first instance wherein a sequential electrocardiographic analysis of stone heart syndrome has been undertaken.

3.
Cardiovasc Dis ; 5(4): 425-436, 1978 Dec.
Article in English | MEDLINE | ID: mdl-15216047

ABSTRACT

The conceptual design and development of a long-term, low-profile intracorporeal left ventricular assist device is a multifaceted project involving a series of technical, anatomic and physiologic considerations. Patients with severe left ventricular failure refractory to all other forms of therapy could benefit from such a device. Prior to fabrication of such a blood pump, consideration must be given to physiologic parameters of the projected patient population. The pump must be designed to meet physiologic demands and yet conform to the anatomic constraints posed by the patient population. We measured the body surface area (BSA) of a group of patients (n=50) and found the mean BSA for this group to be 1.804 +/- 0.161 m(2). Using 25 ml/m(2) as a stroke volume index indicative of left ventricular failure and a stroke volume index of 45 ml/m(2) as normal, distributions of stroke volumes (normal and in left ventricular failure) were plotted for a potential population and demonstrated that 63% of the projected population can be returned to normal by a pump with a stroke volume >/= 83 ml. Cadaver fitting studies established that 73% of the potential population can accommodate an ALVAD 10.8 cm in diameter. In-vitro tests demonstrated that a pump stroke volume >/= 83 ml could be achieved by the proposed pump with a 15 mmHg filling pressure at rates up to 125 B/min. A pusher-plate stroke of 0.56 inches would be necessary to provide a stroke volume >/= 83 ml. The percent of the patient population that could be served was determined by excluding those in whom the pump would not fit or in whom it would provide less than a normal resting stroke volume. Approximately 73% of the projected patient population would accommodate this pump and be returned to normal circulatory dynamics.

4.
Cardiovasc Dis ; 5(3): 271-291, 1978 Sep.
Article in English | MEDLINE | ID: mdl-15216057

ABSTRACT

This study describes five programs that may be used on compact, low-cost programmable calculators with adequate memory and sufficient numbers of program steps to compute cardiorespiratory variables. These short programs are especially useful in the operating room and at the bedside.

SELECTION OF CITATIONS
SEARCH DETAIL
...