1.
Front Bioeng Biotechnol ; 12: 1389127, 2024.
Article in English | MEDLINE | ID: mdl-38751865

ABSTRACT

Introduction: Jones fractures frequently fail to unite, and adequate fixation stability is crucial. This study aimed to elucidate the biomechanical stability of various intramedullary screw fixation constructs. Methods: Jones fracture model over the proximal 5th metatarsal of artificial bone was created in all specimens. Six groups were divided based on varied screw constructs with different screw lengths, either 30 or 40 mm, including cannulated screws-C30 and C40 groups, one high-resistance suture combined with intramedullary cannulated screws (F.E.R.I. technique)-CF30 and CF40 groups, and second-generation headless compression screws (SG-HCS) -HL30 and HL40 groups. Mechanical testing was conducted sequentially, and the maximal force (N) and stiffness (N/mm) of all constructs were recorded. Results: The maximal force (N) at 1.0 mm downward displacement in C30, C40, CF30, CF40, HL30, and HL40 groups were 0.56 ± 0.02, 0.49 ± 0.02, 0.65 ± 0.02, 0.49 ± 0.01, 0.68 ± 0.02, and 0.73 ± 0.02, respectively, and the stiffness (N/mm) in subgroups were 0.49 ± 0.01, 0.43 ± 0.01, 0.67 ± 0.01, 0.42 ± 0.01, 0.61 ± 0.01, and 0.58 ± 0.02, respectively. SG-HCS subgroups exhibited greater maximal force and stiffness than conventional cannulated screws. Screws of 30 mm in length demonstrated better stability than all 40 mm-length screws in each subgroup. In C30 fixation, the stiffness and maximum force endured increased by 1.16 and 1.12 times, respectively, compared with the C40 fixation method. There were no significant differences between CF30 and SG-HCS groups. Only the F.E.R.I technique combined with the 4.5 mm cannulated screw of 30 mm in length increased the biomechanical stability for Jones fractures. Discussion: These biomechanical findings help clinicians decide on better screw fixation options for greater stability in Jones fractures, especially when large-diameter screws are limited in use. However, this biomechanical testing of intramedullary screw fixation on Jones fracture model lacks clinical validation and no comparisons to extramedullary plate fixations. Moving forward, additional clinical and biomechanical research is necessary to validate our findings.

2.
Sci Rep ; 13(1): 20475, 2023 11 22.
Article in English | MEDLINE | ID: mdl-37993498

ABSTRACT

Flexor hallucis longus (FHL) transfer is an effective surgery in treating insertional Achilles tendinopathy (IAT). However, limited data exist regarding the post-surgery changes in the transferred FHL. The study aimed to compare the sequential changes and hypertrophy of FHL after isolated FHL transfer (FHLT). We retrospectively enrolled patients who underwent isolated FHLT for insertional Achilles pathology from 2015 to 2020 and divided them into two groups based on whether reattachment of the residue Achilles stump to the FHL was performed or not. We recorded demographic characteristics, MRI parameters, and functional outcome. We also analyzed the correlation between the collected data and FHL hypertrophy. Results revealed no significant differences in most MRI parameters of FHL and functional outcomes between the groups. However, the fat distribution within the FHL showed significant reduction and notable 20.2% hypertrophy after FHLT. Interestingly, the hypertrophy of the FHL was significantly more pronounced in the non-reattached group. Furthermore, we observed a positive correlation between the follow-up period and FHL hypertrophy. In conclusion, the FHL demonstrated significant enlargement over time following FHLT. The compensatory hypertrophy of the transferred FHL was particularly evident and the cumulative incidences of FHL enlargement over time were higher in the non-reattached groupcompared to reattached group. However, both reattachment and non-reattachment of Achilles stump on FHL transfer for insertional Achilles tendinopathy carried similar postoperative functional outcomes.


Subject(s)
Achilles Tendon , Tendinopathy , Humans , Retrospective Studies , Achilles Tendon/diagnostic imaging , Achilles Tendon/surgery , Tendon Transfer/methods , Tendinopathy/diagnostic imaging , Tendinopathy/surgery , Magnetic Resonance Imaging , Hypertrophy
3.
Bioengineering (Basel) ; 10(11)2023 Oct 24.
Article in English | MEDLINE | ID: mdl-38002362

ABSTRACT

Oblique lumbar interbody fusion (OLIF) can be combined with different screw instrumentations. The standard screw instrumentation is bilateral pedicle screw fixation (BPSF). However, the operation is time consuming because a lateral recumbent position must be adopted for OLIF during surgery before a prone position is adopted for BPSF. This study aimed to employ a finite element analysis to investigate the biomechanical effects of OLIF combined with BPSF, unilateral pedicle screw fixation (UPSF), or lateral pedicle screw fixation (LPSF). In this study, three lumbar vertebra finite element models for OLIF surgery with three different fixation methods were developed. The finite element models were assigned six loading conditions (flexion, extension, right lateral bending, left lateral bending, right axial rotation, and left axial rotation), and the total deformation and von Mises stress distribution of the finite element models were observed. The study results showed unremarkable differences in total deformation among different groups (the maximum difference range is approximately 0.6248% to 1.3227%), and that flexion has larger total deformation (5.3604 mm to 5.4011 mm). The groups exhibited different endplate stress because of different movements, but these differences were not large (the maximum difference range between each group is approximately 0.455% to 5.0102%). Using UPSF fixation may lead to higher cage stress (411.08 MPa); however, the stress produced on the endplate was comparable to that in the other two groups. Therefore, the length of surgery can be shortened when unilateral back screws are used for UPSF. In addition, the total deformation and endplate stress of UPSF did not differ much from that of BPSF. Hence, combining OLIF with UPSF can save time and enhance stability, which is comparable to a standard BPSF surgery; thus, this method can be considered by spine surgeons.

4.
Bioengineering (Basel) ; 10(11)2023 Oct 26.
Article in English | MEDLINE | ID: mdl-38002375

ABSTRACT

The success of spinal fusion surgery relies on the precise placement of bone grafts and minimizing scatter. This study aims to optimize cage design and bone substitute filling methods to enhance surgical outcomes. A 3D printed lumbar spine model was utilized to implant 3D printed cages of different heights (8 mm, 10 mm, 12 mm, and 14 mm) filled with BICERA® Bone Graft Substitute mixed with saline. Two filling methods, SG cage (side hole for grafting group, a specially designed innovative cage with side hole, post-implantation filling) and FP cage (finger-packing group, pre-implantation finger packing, traditional cage), were compared based on the weight of the implanted bone substitute. The results showed a significantly higher amount of bone substitute implanted in the SG cage group compared to the FP cage group. The quantity of bone substitute filled in the SG cage group increased with the height of the cage. However, in the FP cage group, no significant difference was observed between the 12 mm and 14 mm subgroups. Utilizing oblique lumbar interbody fusion cages with side holes for bone substitute filling after implantation offers several advantages. It reduces scatter and increases the amount of implanted bone substitute. Additionally, it effectively addresses the challenge of insufficient fusion surface area caused by gaps between the cage and endplates. The use of cages with side holes facilitates greater bone substitute implantation, ultimately enhancing the success of fusion. This study provides valuable insights for future advancements in oblique lumbar interbody fusion cage design, highlighting the effectiveness of using cages with side holes for bone substitute filling after implantation.

5.
J Neurooncol ; 162(1): 179-189, 2023 Mar.
Article in English | MEDLINE | ID: mdl-36894719

ABSTRACT

PURPOSE: Microsurgery is the mainstay of treatment for large vestibular schwannomas (VS), but the benefits of radiosurgery remain incompletely defined. Here, we aim to use automated volumetric analysis software to quantify the degree of brain stem deformity to predict long-term outcomes of patients with large VS following GKRS. METHODS: Between 2003 and 2020, 39 patients with large VS (volume > 8 cc) undergoing GKRS with a margin dose of 10-12 Gy were analyzed. The reconstruction 3D MRI was used to evaluate the extent of deformity for predicting the long-term outcome of patients. RESULTS: Their mean tumor volume was 13.7 ± 6.3 cc, and their mean follow-up after GKRS was 86.7 ± 65.3 months. Favorable clinical outcome was observed in 26 (66.7%) patients, while 13 (33.3%) patients had treatment failure. Patients with small tumor volumes, low vital structure deformity indice [(TV/(BSV + CerV) and (TV + EV)/(BSV + CerV)], and long distance of tumor to the central line were more likely to have favorable clinical outcome after GKRS. Significant prognostic value was with tumor shrinkage ratio (< 50%) were CV, CV/TV, TV/CerV, (TV + EV)/(BSV + CerV), and the distance of tumor to the central line. In cox regression, favorable clinical outcome was correlated with the Charlson comorbidity index and cochlear dosage (both p < 0.05). In multivariant analysis, tumor regression was highly correlated with the CV/TV ratio (p < 0.001). CONCLUSIONS: The brainstem deformity ratio is likely a useful index to assess the clinical and tumor regression outcomes. Clinical outcomes are multifactorial and the tumor regression was highly correlated with the ratio of cystic components.


Subject(s)
Neuroma, Acoustic , Radiosurgery , Humans , Neuroma, Acoustic/diagnostic imaging , Neuroma, Acoustic/radiotherapy , Neuroma, Acoustic/surgery , Radiosurgery/adverse effects , Treatment Outcome , Prognosis , Treatment Failure , Retrospective Studies , Follow-Up Studies
6.
Front Bioeng Biotechnol ; 10: 949802, 2022.
Article in English | MEDLINE | ID: mdl-36159681

ABSTRACT

Purpose: We sought to analyze the biomechanical effects which both different numbers and locations of screws have on three different clavicle hook plates, as well as any possible causes of sub-acromial bone erosion and peri-implant clavicular fractures. Methods: This study built thirteen groups of finite element models using three different clavicle hook plates (short plates, long plates, and posterior hook offset plates) in varying numbers and locations of the screws. The von Mises stress distribution of the clavicle and hook plate, as well as the reaction force of the acromion was evaluated. Results: The results show that inserting screws in all available screw holes on the hook plate produces a relatively large reaction force on the acromion, particularly in the axial direction of the bone plate. The fewer the screws implanted into the clavicle hook plate, the larger the area of high-stress distribution there is in the middle of the clavicle, and also, the higher the stress distribution on the clavicle hook plate. Conclusion: This study provides orthopedic physicians with the biomechanical analysis of different numbers and locations of screws in clavicle hook plates to help minimize surgical complications.

7.
Sensors (Basel) ; 22(15)2022 Aug 07.
Article in English | MEDLINE | ID: mdl-35957456

ABSTRACT

A mask is one of the most basic protections to prevent the transmission of COVID-19. Surgical mask tension release bands (SMTRBs) are commonly used to ease the pain caused by prolonged mask use. However, the structural strength of SMTRBs and the effect that wearing masks with SMTRBs has on the face are unclear. Thus, this study assessed the mechanics of seven different types of 3D-printed SMTRBs. In this study, a tensile testing machine, a sensor array system, and finite element analysis were used to evaluate the mechanisms of seven SMTRBs. The tensile testing machine was applied to measure the breaking strength, elongation, stiffness, and rupture of the band. The sensor array system was used to calculate the pressure on the face when the band was used together with the mask. Finite element analysis was applied to evaluate the level of stress on the SMTRB structure when each of the seven bands was subjected to external force. The results demonstrated that thick SMTRBs put more pressure on the face but had greater structural strength. The thinner bands did not break easily; however, the mask ear loops tended to slip off more often. In addition, the size of the band hook affected the magnitude of the external force. This study provides a biomechanical reference for the future design of SMTRBs.


Subject(s)
COVID-19 , Masks , Biomechanical Phenomena , Finite Element Analysis , Humans , Printing, Three-Dimensional
8.
Polymers (Basel) ; 14(4)2022 Feb 14.
Article in English | MEDLINE | ID: mdl-35215636

ABSTRACT

During certain clinical situations, some parturients require instruments for operative vaginal delivery, and various designs of vacuum extractors may affect the fetal head. To investigate the biomechanical effects of divergent sizes of silicone rubber vacuum extractors, we employed finite element analysis in this study. First, we constructed computer models for different vacuum extractor sizes (diameters: 40 mm, 50 mm, 60 mm, and 70 mm), flat surface, hemispherical ball, and fetal head shape. A hemispherical ball was the main design for the vacuum extractor model, and the material used for the vacuum extractor was silicone rubber. Next, the settings of 1 mm vacuum extractor displacement and vacuum cap pressure of 60 cmHg were applied. The main observation markers of this study were the respective von Mises stresses on the vacuum extractor and skull by the reaction force on the fixed end. The concluded results revealed that vacuum extractors with larger diameters lead to greater reaction force, stress, and strain on fetal heads. Therefore, this study's biomechanical analytic consequences suggest that clinicians avoid selecting larger vacuum extractors during operative instrumental delivery so that fetal heads will experience less external force, deformation, and resultant complications. It could also provide a practical reference for obstetricians for instrumental vaginal delivery with the vacuum extractor made of silicone rubber.

9.
J Chin Med Assoc ; 84(11): 1038-1047, 2021 11 01.
Article in English | MEDLINE | ID: mdl-34596083

ABSTRACT

BACKGROUND: Medial displacement calcaneal osteotomy (MDCO) is frequently used for the surgical correction of flatfoot. This study aims to investigate the biomechanical effect of the different diagonal screw design on a novel-designed embedded calcaneal plate for MDCO using finite element analysis (FEA), mechanical test and digital image correlation (DIC) measurement. METHODS: Four groups according to the varied implanted plate were set as control group (Group 1), non-diagonal screw (Group 2), one-diagonal screw (Group 3), and two-diagonal screws groups (Group 4). For FEA, A 450 N load was applied to on the anterior process of the calcaneus from top to bottom. Observational indices included the stress on the cortical and cancellous bone of the calcaneus surrounding the implant, the plate itself as well as screws, and the displacement of the overall structure. In addition, this study also used in vitro biomechanics test to investigate the stiffness of the structure after implantation, and used DIC to observe the displacement of the calcaneus structure after external force. RESULTS: Under a simulated load in FEA, there are significant overall instability and high stress concentration on the calcaneal surrounding host bone and the plate/screws system, respectively, in group 2 compared with other groups. Regard to the mechanical testing with DIC system, significant increased rotation stability, maximum force and stiffness with the addition of diagonal screws. In comparison to Group 2, the increase of 112% and 157% in maximum force as well as 104% and 176% in stiffness were found in Group 3 and 4, respectively. CONCLUSION: For reducing stress concentration and enhancing overall stability, more than one-diagonal screw design is recommended and two-diagonal screws design will be superior. This study provided biomechanical references for further calcaneal implants design to prevent clinical failure after MDCO.


Subject(s)
Bone Plates , Bone Screws , Fracture Fixation, Internal/methods , Heel Spur/surgery , Biomechanical Phenomena , Finite Element Analysis , Humans , Osteotomy/methods , Weight-Bearing
10.
BMC Musculoskelet Disord ; 22(1): 879, 2021 Oct 14.
Article in English | MEDLINE | ID: mdl-34649557

ABSTRACT

BACKGROUND: Reduction of lumbar spondylolisthesis during spinal fusion surgery is important for improving the fusion rate and restoring the sagittal alignment. Despite the variety of reduction methods, the fundamental mechanics of lumbar spondylolisthesis reduction remain unclear. This study aimed to investigate the biomechanical behavior while performing spondylolisthesis reduction with the anterior and posterior lever reduction method. METHODS: We developed an L4-L5 spondylolisthesis model using sawbones. Two spine surgeons performed the simulated reduction with a customized Cobb elevator. The following data were collected: the torque and angular motion of Cobb, displacement of vertebral bodies, change of lordotic angle between L4 and L5, total axial force and torque applied on the model, and force received by adjacent disc. RESULTS: Less torque value (116 N-cm vs. 155 N-cm) and greater angular motion (53o vs. 38o) of Cobb elevator were observed in anterior lever reduction. Moreover, the total axial force received by the entire model was greater in the posterior lever method than that in the anterior lever method (40.8 N vs. 16.38 N). Besides, the displacement of both vertebral bodies was greater in the anterior lever method. CONCLUSIONS: The anterior lever reduction is a more effort-saving method than the posterior lever reduction method. The existing evidence supports the biomechanical advantage of the anterior reduction method, which might be one of the contributing factors to successfully treating high-grade lumbar spondylolisthesis with short-segment instrumentation.


Subject(s)
Lordosis , Plastic Surgery Procedures , Spinal Fusion , Spondylolisthesis , Biomechanical Phenomena , Humans , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Spondylolisthesis/diagnostic imaging , Spondylolisthesis/surgery
11.
BMC Oral Health ; 21(1): 543, 2021 10 21.
Article in English | MEDLINE | ID: mdl-34674692

ABSTRACT

BACKGROUND: Many types of titanium plates were used to treat subcondylar fracture clinically. However, the efficacy of fixation in different implant positions and lengths of the bone plate has not been thoroughly investigated. Therefore, the primary purpose of this study was to use finite element analysis (FEA) to analyze the biomechanical effects of subcondylar fracture fixation with miniplates at different positions and lengths so that clinicians were able to find a better strategy of fixation to improve the efficacy and outcome of treatment. METHODS: The CAD software was used to combine the mandible, miniplate, and screw to create seven different FEA computer models. These models with subcondylar fracture were fixed with miniplates at different positions and of different lengths. The right unilateral molar clench occlusal mode was applied. The observational indicators were the reaction force at the temporomandibular joint, von Mises stress of the mandibular bone, miniplate and screw, and the sliding distance on the oblique surface of the fracture site at the mandibular condyle. RESULTS: The results showed the efficacy of fixation was better when two miniplates were used comparing to only one miniplates. Moreover, using longer miniplates for fixation had better results than the short one. Furthermore, fixing miniplates at the posterior portion of subcondylar region would have a better fixation efficacy and less sliding distance (5.46-5.76 µm) than fixing at the anterolateral surface of subcondylar region (6.10-7.00 µm). CONCLUSION: Miniplate fixation, which was placed closer to the posterior margin, could effectively reduce the amount of sliding distance in the fracture site, thereby achieving greater stability. Furthermore, fixation efficiency was improved when an additional miniplate was placed at the anterior margin. Our study suggested that the placement of miniplates at the posterior surface and the additional plate could effectively improve stability.


Subject(s)
Mandibular Fractures , Bone Plates , Fracture Fixation , Fracture Fixation, Internal , Humans , Mandibular Condyle/surgery , Mandibular Fractures/surgery
12.
Clin Oral Investig ; 25(10): 5661-5670, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33665683

ABSTRACT

OBJECTIVE: The study objective was to investigate four common occlusal modes by using the finite element (FE) method and to conduct a biomechanical analysis of the periodontal ligament (PDL) and surrounding bone when orthodontic force is applied. MATERIALS AND METHODS: A complete mandibular FE model including teeth and the PDL was established on the basis of cone-beam computed tomography images of an artificial mandible. In the FE model, the left and right mandibular first premolars were not modeled because both canines required distal movement. In addition, four occlusal modes were simulated: incisal clench (INC), intercuspal position (ICP), right unilateral molar clench (RMOL), and right group function (RGF). The effects of these four occlusal modes on the von Mises stress and strain of the canine PDLs and bone were analyzed. RESULTS: Occlusal mode strongly influenced the distribution and value of von Mises strain in the canine PDLs. The maximum von Mises strain values on the canine PDLs were 0.396, 1.811, 0.398, and 1.121 for INC, ICP, RMOL, and RGF, respectively. The four occlusal modes had smaller effects on strain distribution in the cortical bone, cancellous bone, and miniscrews. CONCLUSION: Occlusal mode strongly influenced von Mises strain on the canine PDLs when orthodontic force was applied. CLINICAL RELEVANCE: When an FE model is used to analyze the biomechanical behavior of orthodontic treatments, the effect of muscle forces caused by occlusion must be considered.


Subject(s)
Periodontal Ligament , Tooth Movement Techniques , Bicuspid/diagnostic imaging , Biomechanical Phenomena , Computer Simulation , Finite Element Analysis , Periodontal Ligament/diagnostic imaging , Stress, Mechanical
13.
Am J Transl Res ; 12(7): 3728-3740, 2020.
Article in English | MEDLINE | ID: mdl-32774730

ABSTRACT

BACKGROUND: Experiments were conducted on the assumption that vivid chondrogenesis would be boosted in vivo following previously preliminary chondrogenesis in a mesenchymal stem cell (MSC)-rich entire umbilical cord (UC) in vitro. METHODS: Virtual 3-D tracheal grafts were generated by using a profile obtained by scanning the native trachea of the listed porcine. Although the ultimate goal was the acquisition of a living specimen beyond a 3-week survival period, the empirical results did not meet our criteria until the 10th experiment, ending with the sacrifice of the animal. The categories retrospectively evolved from post-transplant modification due to porcine death using 4 different methods of implantation in chronological order. For each group, we collected details on graft construction, clinical outcomes, and results from both gross and histology examinations. RESULTS: Three animals died due to tracheal complications: one died from graft crush, and two died secondary to erosion of the larger graft into the great vessels. It appeared that the remaining 7 died of tracheal stenosis from granulation tissue. Ectopic de novo growth of neocartilage was found in three porcine subjects. In the nearby tissues, we detected neocartilage near the anastomosis containing interim vesicles of the vascular canals (VCs), perichondrial papillae (PPs) and preresorptive layers (PRLs), which were investigated during the infancy of cartilage development and were first unveiled in the tracheal cartilage. CONCLUSIONS: 3-D-printed anatomically precise grafts could not provide successful transplantation with stent-sparing anastomosis; nonetheless, de novo cartilage regeneration in situ appears to be promising for tracheal graft adaptability. Further graft refinement and strategies for managing granulated tissues are still needed to improve graft outcomes.

14.
Technol Health Care ; 28(6): 593-602, 2020.
Article in English | MEDLINE | ID: mdl-32716339

ABSTRACT

BACKGROUND: Dynamic hip screw (DHS) is a common implant used to treat stable-type intertrochanteric hip fractures. There are many factors that can affect the success rate of the surgery, including the length of side plates. It is therefore important to investigate the biomechanical effect of different DHS side plates on bones. OBJECTIVE: In order to reduce the likelihood of an implant failure, the aim of this study was to use finite element analysis (FEA) to investigate and understand the effect of side plates with different lengths in DHS. METHODS: In this FEA study, a 3D model with cortical bone, cancellous bone, side plate, lag screw, and cortical screws to simulate the implantation of DHS with different lengths of side plate (2-hole, 4-hole, and 6-hole) for intertrochanteric hip fractures was constructed. The loading condition was used to simulate the force (400 N) on the femoral head and the stress distribution on the lag screw, side plate, cortical screws, and femur was measured. RESULTS: The highest stress points occured around the region of contact between the screw and the cortical bones. The stress on the femur at the most distal cortical screw was the greatest. The shorter the length of the side plate, the greater the stress on the cortical screws, resulting in an increased stress on the femur surrounding the cortical screws. CONCLUSIONS: The use of DHS with 2-hole side plate may increase the risk of side plate pull-out. The results of this study provide a biomechanical analysis for selection of DHS implant lengths that can be useful for orthopaedic surgeons.


Subject(s)
Fracture Fixation, Internal , Hip Fractures , Biomechanical Phenomena , Bone Plates , Bone Screws , Finite Element Analysis , Hip Fractures/surgery , Humans
15.
Appl Bionics Biomech ; 2019: 4989013, 2019.
Article in English | MEDLINE | ID: mdl-31281415

ABSTRACT

The bilateral sagittal split osteotomy (BSSO) technique is commonly used to correct mandibular deficiency. If the patient is exposed to excessive external forces after the procedure, occlusal changes or nonunion may occur. However, previous studies only focused on single external forces on the mandible and did not conduct relevant research on the forces exerted by different occlusion conditions. The main purpose of this study was to use finite element analysis methods to determine the biomechanics of four common occlusion conditions after BSSO surgical treatment. This study constructed a finite element analysis computer model of a miniplate implanted in the lower jaw. The structure of the model consisted of the mandible, miniplate, and screws. In addition, external forces were applied to the superficial masseter, deep masseter, medial pterygoid, anterior temporalis, middle temporalis, and posterior temporalis muscles to simulate the incisal clench, intercuspal position (ICP), right unilateral molar clench (RMOL), and right group function occlusion conditions. Subsequently, this study observed the effects of these conditions on the miniplate, screws, and mandible, including the von Mises stress values. The results showed that all of the different occlusion conditions that this study evaluated placed high stress on the miniplate. In the ICP and RMOL occlusion conditions, the overall mandibular structure experienced very high stress. The screw on the proximal segment near the bone gap experienced high stress, as did the screw on the buccal side. According to the present analysis, although the data were not directly obtained from clinical practice, the finite element analysis could evaluate the trend of results under different external forces. The result of this study recommended that patients without intermaxillary fixation avoid the ICP and RMOL occlusion conditions. It can be used as a pilot study in the future for providing clinicians more information on the biomechanics of implantation.

16.
Appl Bionics Biomech ; 2019: 4021640, 2019.
Article in English | MEDLINE | ID: mdl-31205482

ABSTRACT

For compression fracture, vertebral body height loss (VBHL) and kyphotic angle (KA) are two important imaging parameters for determining the prognosis and appropriate treatment. This study used previous measurement methods to assess the degree of VBHL and KA, compare and examine differences between various measurement methods, and examine the correlation between relevant measurement parameters and intravertebral cleft (IVC) in the vertebral body. The radiographic images (lateral view of the T-L spine) of 18 patients with a single-level vertebral compression fracture were reviewed. We measured 9 characteristic lengths and angles on plain radiographs, including anterior vertebral height (AVH) and AVH of the adjacent upper and lower levels, middle vertebral height (MVH) and MVH of the adjacent upper and lower levels, posterior vertebral height (PVH), and vertebral body width, and assessed 6 parameters, including vertebral compression ratio (VBCR), percentage of anterior height compression (PAHC), percentage of middle height compression (PMHC), kyphotic angle (KA), calculated kyphotic angle (CKA), and IVC. The results showed that VBCR is a simple and rapid method of VBHL assessment, but it may result in an underestimation of the degree of VBHL compared to PAHC. When PMHC < 40% or kyphotic angle > 15°, the probability of IVC occurring on the vertebral body was higher which means the higher risk of vertebral body instability. The results of this study could provide a reference for surgeons when using imaging modalities to assess the degree of vertebral body collapse.

17.
BMC Musculoskelet Disord ; 19(1): 411, 2018 Nov 24.
Article in English | MEDLINE | ID: mdl-30474544

ABSTRACT

BACKGROUND: Reasons for dissatisfaction with total knee arthroplasty (TKA) include unequal flexion or extension gap, soft tissue imbalance, and patella maltracking, which often occur with mismatch between femoral and tibial coronal bony alignment in the knee joint or extremely varus or valgus alignment. However, lower limb coronal alignment classification is based only on hip-knee-ankle angle (HKAA), leading to oversight regarding a mismatch between femoral and tibial coronal alignment. We aimed to classify alignment of the lower limbs according to the mechanical alignment of the femur and tibia in a healthy population. METHODS: All 214 normal triple films were reviewed retrospectively. HKAA, mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), angle between the femoral anatomical axis and the mechanical axis (AA-MA), and knee alignment angle (KAA) were measured. Subjects were categorized into one of five types based on the mechanical alignment of femur and tibia. RESULTS: Mean HKAA, mLDFA, and mMPTA of all subjects were 1.2°, 87.3°, and 85.8°, respectively. All subjects were classified into one of five types with significant differences (p < 0.001). About 61% of subjects showed neutral alignment, of which nearly 40% were type 2 (valgus of the femur and varus of the tibia with oblique joint line: mLDFA 85.0° ± 1.4°, mMPTA 85.1° ± 1.2°, TJLA 2.7° ± 2.4°) and 60% exhibited neutral alignment with a neutral femur and tibia (type 1). In varus and valgus types, mismatch between the mechanical angle of the femur and tibia was common. Varus alignment, including types 3 (varus of the tibia: mLDFA 88.0° ± 1.4°, mMPTA 83.5° ± 1.6°) and 4 (varus of both the tibia and femur: mLDFA 91.4° ± 1.4°, mMTPA 85.2° ± 2.0°), was found in 30% of subjects. Valgus alignment (type 5 valgus of femur: mLDFA 84.6° ± 1.6°, mMPTA 88.8° ± 2.0°) accounted for 8.9% of all subjects. CONCLUSIONS: Mismatch between mechanical alignment of the femur and tibia was common in varus and valgus alignment types. Joint line obliquity was also observed in 40% of the neutral alignment population. This classification provides a quick, simple interpretation of femoral and tibial coronal alignment, and more detailed guidance for preoperative planning for TKA than the traditional varus-neutral-valgus classification.


Subject(s)
Femur/diagnostic imaging , Femur/physiology , Knee Joint/diagnostic imaging , Knee Joint/physiology , Tibia/diagnostic imaging , Tibia/physiology , Adult , Aged , Biomechanical Phenomena/physiology , Female , Femur/abnormalities , Humans , Knee Joint/abnormalities , Male , Middle Aged , Retrospective Studies , Tibia/abnormalities , Weight-Bearing/physiology , Young Adult
18.
J Int Med Res ; 46(6): 2128-2140, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29848122

ABSTRACT

Background Cephalomedullary nails are frequently used in unstable intertrochanteric fractures. The implant position is an important factor for surgical success. Thus, in the present study, finite element analysis methods were used to investigate the biomechanical behavior of five different cephalomedullary nail positions in unstable intertrochanteric fractures. Methods Five different cephalomedullary nail implant positions were investigated. The observed indicators were the maximum displacement of the lag screw, the stress on the intertrochanteric fracture with involvement of the posteromedial cortex, and the tip-apex distance. Results The smallest lag screw displacement was achieved when the implant was closer to the inferior femoral head. Lower stress was placed on the posteromedial cortex when the implant was positioned closer to the inferior femoral head. However, the tip-apex distance increased when the lag screw was positioned more inferiorly. Conclusions The results of this study suggest that positioning the lag screw closer to the inferior aspect of the femoral head can reduce stress on the posteromedial cortex and deformation of the implant in unstable intertrochanteric fractures. These findings provide a biomechanical basis for selection of the cephalomedullary nail implantation site. Level of evidence III.


Subject(s)
Femur Head/diagnostic imaging , Femur Head/surgery , Fracture Fixation, Intramedullary/instrumentation , Hip Fractures/diagnostic imaging , Hip Fractures/surgery , Biomechanical Phenomena , Bone Nails , Bone Screws , Computer Simulation , Femur Head/physiopathology , Finite Element Analysis , Fracture Fixation, Intramedullary/methods , Hip Fractures/physiopathology , Humans , Models, Anatomic , Treatment Outcome
19.
Int Orthop ; 41(8): 1663-1669, 2017 08.
Article in English | MEDLINE | ID: mdl-28097386

ABSTRACT

PURPOSE: A clavicle hook plate is a simple and effective method for treating acromioclavicular dislocation and distal clavicle fractures. However, subacromial osteolysis and peri-implant fractures are complicated for surgeons to manage. This study uses finite element analysis (FEA) to investigate the post-implantation biomechanics of clavicle hook plates with different hook angles. METHODS: This FEA study constructed a model with a clavicle, acromion, clavicle hook plate, and screws to simulate the implantation of clavicle hook plates at different hook angles (90°, 95°, 100°, 105°, and 110°) for treating acromioclavicular joint dislocations. This study investigated the biomechanics of the acromion, clavicle, hook plate, and screws. RESULTS: A smaller hook angle increases the stress on the middle third of the clavicle. A larger hook angle increases the force exerted by the clavicle hook plate on the acromion. The screw at the most medial position on the plate generated the highest stress. The highest stress on the implanted clavicle hook plate was on the turning corner of the hook. CONCLUSIONS: A clavicle hook plate with different hook angles may induce different biomechanical behaviors in the clavicle and acromion. Orthopedic surgeons must select a suitable clavicle hook plate based on the anatomical structure of each patient.


Subject(s)
Acromioclavicular Joint/surgery , Bone Plates , Fracture Fixation, Internal/methods , Joint Dislocations/surgery , Acromioclavicular Joint/injuries , Acromioclavicular Joint/physiopathology , Acromion/physiopathology , Acromion/surgery , Biomechanical Phenomena , Bone Screws , Clavicle/injuries , Clavicle/physiopathology , Clavicle/surgery , Computer Simulation , Finite Element Analysis , Fracture Fixation, Internal/instrumentation , Fractures, Bone/physiopathology , Fractures, Bone/surgery , Humans , Joint Dislocations/physiopathology
20.
Artif Organs ; 40(11): 1062-1070, 2016 Nov.
Article in English | MEDLINE | ID: mdl-26814438

ABSTRACT

Clinical implantation of clavicle hook plates is often used as a treatment for acromioclavicular joint dislocation. However, it is not uncommon to find patients that have developed acromion osteolysis or had peri-implant fracture after hook plate fixation. With the aim of preventing complications or fixation failure caused by implantation of inappropriate clavicle hook plates, the present study investigated the biomechanics of clavicle hook plates made of different materials and with different hook depths in treating acromioclavicular joint dislocation, using finite element analysis (FEA). This study established four parts using computer models: the clavicle, acromion, clavicle hook plate, and screws, and these established models were used for FEA. Moreover, implantations of clavicle hook plates made of different materials (stainless steel and titanium alloy) and with different depths (12, 15, and 18 mm) in patients with acromioclavicular joint dislocation were simulated in the biomechanical analysis. The results indicate that deeper implantation of the clavicle hook plate reduces stress on the clavicle, and also reduces the force applied to the acromion by the clavicle hook plate. Even though a clavicle hook plate made of titanium alloy (a material with a lower Young's modulus) reduces the force applied to the acromion by the clavicle hook plate, slightly higher stress on the clavicle may occur. The results obtained in this study provide a better reference for orthopedic surgeons in choosing different clavicle hook plates for surgery.


Subject(s)
Acromioclavicular Joint/surgery , Bone Plates , Clavicle/surgery , Finite Element Analysis , Fracture Fixation, Internal/instrumentation , Joint Dislocations/surgery , Alloys , Biomechanical Phenomena , Computer Simulation , Humans , Osteolysis/prevention & control , Periprosthetic Fractures/prevention & control , Postoperative Complications/prevention & control , Stainless Steel , Titanium , Treatment Outcome