Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Anaesthesia ; 68(11): 1189-90, 2013 Nov.
Article in English | MEDLINE | ID: mdl-24128016
2.
Anaesthesia ; 65(1): 78-81, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19849679

ABSTRACT

A 29-year-old patient presented with dysphonia, dysphagia and a progressive history of stridor over 6 weeks. His past medical history included childhood nasolabial rhabdomyosarcoma treated by surgery, chemotherapy and radiotherapy. This had resulted in marked abnormalities of the facial skeleton, limited neck extension and restricted mouth opening of 1 cm, in part due to dental implants. After careful discussion and planning within a multidisciplinary team, the airway was optimised by temporary removal of the dental implants. This enabled a suspension laryngoscope to be passed, permitting carbon dioxide laser treatment to an obstruction at the laryngeal inlet and eliminating the need for a tracheostomy.


Subject(s)
Airway Obstruction/surgery , Dental Implants , Laryngoscopy/methods , Laser Therapy/methods , Adult , Airway Obstruction/etiology , Combined Modality Therapy , Device Removal , Head and Neck Neoplasms/therapy , Humans , Male , Patient Care Team , Rhabdomyosarcoma/therapy
3.
Anaesthesia ; 63(10): 1135-8, 2008 Oct.
Article in English | MEDLINE | ID: mdl-18717662

ABSTRACT

We investigated the effect of temperature on single use and reuseable bougies. In a photographic study, three bougies (Portex Venn reuseable (R), Portex single use (S) and Breathesafe single use (B)) were exposed to increasing temperatures and sequential photographs were taken of the bougies uncoiling from a preformed curve. Bougie type was associated with rate of uncoiling, type R maintaining its curve the longest but changing temperature did not affect this. In a randomised cross-over manikin study, 16 anaesthetists attempted to pass two bougies (Portex reuseable (R) and Portex single use (S)) at three temperatures (10, 20 and 30 degrees C) into the trachea of a manikin. Type R was significantly associated with higher success rate of tracheal placement compared to type S. Change of temperature was significant with success rate increasing with lower temperature. The odds of success at 10 degrees C was six times that at 30 degrees C (OR (95%) 6.7 (1.7, 25.7)). We concluded that both bougies performed best at 10 degrees C.


Subject(s)
Intubation, Intratracheal/instrumentation , Cross-Over Studies , Disposable Equipment , Equipment Design , Equipment Failure Analysis , Equipment Reuse , Humans , Manikins , Photography , Temperature
SELECTION OF CITATIONS
SEARCH DETAIL
...