Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Proteome Res ; 11(3): 1868-78, 2012 Mar 02.
Article in English | MEDLINE | ID: mdl-22257466

ABSTRACT

We have investigated the precision of peptide quantitation by MALDI-TOF mass spectrometry (MS) using six pairs of proteotypic peptides (light) and same-sequence stable isotope labeled synthetic internal standards (heavy). These were combined in two types of dilution curves spanning 100-fold and 2000-fold ratios. Coefficients of variation (CV; standard deviation divided by mean value) were examined across replicate MALDI spots using a reflector acquisition method requiring 100 000 counts for the most intense peak in each summed spectrum. The CV of light/heavy peptide centroid peak area ratios determined on four replicate spots per sample, averaged across 11 points of a 100-fold dilution curve and over all six peptides, was 2.2% (ranging from 1.5 to 3.7% among peptides) at 55 fmol total (light + heavy) of each peptide applied per spot, and 2.5% at 11 fmol applied. The average CV of measurements at near-equivalence (light = heavy, the center of the dilution curve) for the six peptides was 1.0%, about 17-fold lower CV than that observed when five peptides were ratioed to a sixth peptide (i.e., a different-sequence internal standard). Response curves across the 100-fold range were not completely linear but could be closely modeled by a power law fit giving R(2) values >0.998 for all peptides. The MALDI-TOF MS method was used to determine the endogenous level of a proteotypic peptide (EDQYHYLLDR) of human protein C inhibitor (PCI) in a plasma digest after enrichment by capture on a high affinity antipeptide antibody, a technique called stable isotope standards and capture by anti-peptide antibodies (SISCAPA). The level of PCI was determined to be 770 ng/mL with a replicate measurement CV of 1.5% and a >14 000-fold target enrichment via SISCAPA-MALDI-TOF. These results indicate that MALDI-TOF technology can provide precise quantitation of high-to-medium abundance peptide biomarkers over a 100-fold dynamic range when ratioed to same-sequence labeled internal standards and enriched to near purity by specific antibody capture. The robustness and throughput of MALDI-TOF in comparison to conventional nano-LC-MS technology could enable currently impractical large-scale verification studies of protein biomarkers.


Subject(s)
Peptide Fragments/chemistry , Amino Acid Sequence , Calibration , Humans , Molecular Sequence Data , Molecular Weight , Peptide Fragments/blood , Protein C Inhibitor/blood , Protein C Inhibitor/chemistry , Proteolysis , Proteomics , Reference Standards , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/methods , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization/standards , Trypsin/chemistry
2.
J Proteome Res ; 8(7): 3239-51, 2009 Jul.
Article in English | MEDLINE | ID: mdl-19402737

ABSTRACT

Currently, the precursor ion selection strategies in LC-MS mainly choose the most prominent peptide signals for MS/MS analysis. Consequently, high-abundance proteins are identified by MS/MS of many peptides, whereas proteins of lower abundance might elude identification. We present a novel, iterative and result-driven approach for precursor ion selection that significantly increases the efficiency of an MS/MS analysis by decreasing data redundancy and analysis time. By simulating different strategies for precursor ion selection on an existing data set, we compare our method to existing result-driven strategies and evaluate its performance with regard to mass accuracy, database size, and sample complexity.


Subject(s)
Chromatography, Liquid/methods , Mass Spectrometry/methods , Proteomics/methods , Algorithms , Cell Line , Computer Simulation , Databases, Protein , Escherichia coli/metabolism , Humans , Ions , Models, Statistical , Peptides/analysis , Proteins/chemistry , Reproducibility of Results , Software
SELECTION OF CITATIONS
SEARCH DETAIL
...