Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
Add more filters










Publication year range
1.
Br J Plast Surg ; 58(4): 569-72, 2005 Jun.
Article in English | MEDLINE | ID: mdl-15897046

ABSTRACT

Two patients undergoing fibula flap mandible reconstruction developed chronic intraoral wounds and salivary fistulae. After initial attempts at salvage, tissue biopsies demonstrated Actinomycosis infection. With antibiotic treatment and debridement, one reconstruction was salvaged while one was lost. Actinomycosis infection should be considered a possible agent in chronic wounds complicating mandible reconstructions with microsurgical flaps.


Subject(s)
Actinomycosis/diagnosis , Mandible/surgery , Plastic Surgery Procedures/methods , Surgical Flaps/pathology , Surgical Wound Infection/diagnosis , Bone Transplantation , Graft Rejection/microbiology , Humans , Male , Middle Aged , Surgical Wound Infection/microbiology
3.
Ann Plast Surg ; 47(5): 555-9; discussion 559-61, 2001 Nov.
Article in English | MEDLINE | ID: mdl-11716270

ABSTRACT

Primary nerve grafting in traumatic injuries is rarely performed because of the uncertainty of the extent of injury, the limited availability of nerve grafts, and the damage to adjacent soft tissue. In this report the authors present two cases of acute nerve grafting after trauma-the first of the common peroneal nerve and the second of the ulnar nerve above the elbow-with sensory and motor recovery. Although compelling general arguments against primary posttraumatic nerve grafting exist, these cases illustrate that, in certain favorable and critical clinical situations, acute nerve grafting may be successful.


Subject(s)
Arm Injuries/surgery , Leg Injuries/surgery , Peroneal Nerve/transplantation , Ulnar Nerve/transplantation , Adult , Humans , Male
5.
Biomed Sci Instrum ; 37: 299-303, 2001.
Article in English | MEDLINE | ID: mdl-11347406

ABSTRACT

Tolerance of neural tissue to external compression has been shown to depend on several factors. The mechanism by which acute compression alters peripheral nerve conduction is not completely understood. Ischemic and mechanical factors have alternatively been implicated as the primary causes of nerve dysfunction in compression syndromes. An ischemic etiology for acute nerve compression would be favored if there were changes in pressure within the carpal canal. Upon excision of the synovial tissue from within the canal it has been recognized that the tissue can absorb media and swell to three times it original size. This investigation compares the synovial tissue obtained during carpal tunnel surgeries with synovial tissue collected from control patients presenting with injuries not related to carpal tunnel syndrome. A total of twenty-seven carpal patients and six control patients were included within the study. The synovial tissue was obtained, weighed and placed in a 2 ml of sterile phosphate buffer saline (pH 7.3). The rate of fluid up take was determined at intervals of 15 minutes for the first two hours and then hourly for an additional four hours. The results indicate an increase in fluid uptake ranging between 0.004 mg/min to 0.011 mg/min for the first hour in the CTS patients. The rate of fluid uptake subsides after 4 hours. Control patients exhibited less of an increase in fluid uptake ranging between 0.003 to 0.007 over the first three hours. These differences in fluid retention of the different tissues may suggest a tendency for increased fluid pressure within the carpal canal, which may cause compression of the neural tissues.


Subject(s)
Carpal Tunnel Syndrome/physiopathology , Median Nerve/pathology , Synovial Membrane/physiopathology , Adult , Aged , Carpal Tunnel Syndrome/pathology , Edema/pathology , Edema/physiopathology , Female , Humans , In Vitro Techniques , Male , Middle Aged , Sodium Chloride , Synovial Membrane/pathology
7.
Hand Surg ; 5(2): 113-8, 2000 Dec.
Article in English | MEDLINE | ID: mdl-11301504

ABSTRACT

When articular restoration and congruity cannot be accomplished in distal radial fractures owing to severe articular bone loss or comminution, early wrist arthrodesis should be considered. This procedure rapidly restores wrist alignment and stability and controls pain. Arthrodesis is a highly reliable and definitive procedure that optimises the opportunity for early functional and occupational recovery while minimising the risks of developing stiff digits or chronic pain in injuries otherwise doomed from the start of treatment to result in severe wrist stiffness and post-traumatic arthritis. Simultaneous proximal row carpectomy or the use of ipsilateral local bone graft donor sites, such as the distal radius or proximal ulna, decrease both initial treatment and hospital costs and morbidity. Wrist arthrodesis is also effective when polytrauma or multiple fractures co-exist. Successful early treatment may expedite return to work and reduce lost time and wages resulting from the injury.


Subject(s)
Arthrodesis , Radius Fractures/surgery , Wrist Injuries/surgery , Wrist Joint/surgery , Humans , Male , Middle Aged , Radiography , Radius Fractures/diagnostic imaging , Wrist Injuries/diagnostic imaging , Wrist Joint/diagnostic imaging
8.
Med Biol Eng Comput ; 31(6): 569-75, 1993 Nov.
Article in English | MEDLINE | ID: mdl-8145581

ABSTRACT

The paper reports a theoretical investigation into the effects of lower-body negative pressure on blood flow through the human cardiovascular system. The human cardiovascular system is modelled as a closed network of arteries, arterioles, capillaries, venules and veins of different lengths and cross-sections. The pumping action is provided by the contraction of the ventricles. The model has been analysed using the finite-element method. The pertinent equations incorporating the effects of lower-body negative pressure for the pressures and flow velocities have been derived, and the quantitative results have been computed. Percentage changes in flow velocities, pressure drops and conductances under the application of lower-body negative pressure in the various segments and organs of the entire cardiovascular system are obtained. The lower-body negative pressure has no effect on the flow rates in carotid, ulnar and coronary arteries, nor on the supply of blood to the upper extremities, kidneys, spleen and liver. The major effects are found in the lower extremities.


Subject(s)
Hemorheology , Lower Body Negative Pressure , Models, Cardiovascular , Blood Vessels/physiology , Humans , Mathematics
9.
Phys Med Biol ; 38(3): 369-78, 1993 Mar.
Article in English | MEDLINE | ID: mdl-8451280

ABSTRACT

This paper reports a theoretical study on the distribution of blood flow in the human cardiovascular system when one or more blood vessels are affected by stenosis. The analysis employs a mathematical model of the entire system based on the finite element method. The arterial-venous network is represented by a large number of interconnected segments in the model. Values for the model parameters are based upon the published data on the physiological and rheological properties of blood. Computational results show how blood flow through various parts of the cardiovascular system is affected by stenosis in different blood vessels. No significant changes in the flow parameters of the cardiovascular system were found to occur when the reduction in the lumen diameter of the stenosed vessels was less than 65%.


Subject(s)
Blood Circulation/physiology , Cardiovascular Diseases/physiopathology , Models, Cardiovascular , Constriction, Pathologic/physiopathology , Humans , Mathematics
10.
Med Biol Eng Comput ; 30(3): 311-6, 1992 May.
Article in English | MEDLINE | ID: mdl-1453803

ABSTRACT

The paper presents a detailed model of the entire human cardiovascular system which aims to study the changes in flow distribution caused by external stimuli, changes in internal parameters, or other factors. The arterial-venous network is represented by 325 interconnected elastic segments. The mathematical description of each segment is based on equations of hydrodynamics and those of stress/strain relationships in elastic materials. Appropriate input functions provide for the pumping of blood by the heart through the system. The analysis employs the finite-element technique which can accommodate any prescribed boundary conditions. Values of model parameters are from available data on physical and rheological properties of blood and blood vessels. As a representative example, simulation results on changes in flow distribution with changes in the elastic properties of blood vessels are discussed. They indicate that the errors in the calculated overall flow rates are not significant even in the extreme case of arteries and veins behaving as rigid tubes.


Subject(s)
Cardiovascular Physiological Phenomena , Models, Biological , Blood Flow Velocity , Humans , Mathematics
11.
Phys Med Biol ; 37(5): 1033-45, 1992 May.
Article in English | MEDLINE | ID: mdl-1608993

ABSTRACT

This paper reports on a theoretical investigation into the effects of vasomotion on blood through the human cardiovascular system. The finite element method has been used to analyse the model. Vasoconstriction and vasodilation may be effected either through the action of the central nervous system or autoregulation. One of the conditions responsible for vasomotion is exercise. The proposed model has been solved and quantitative results of flows and pressures due to changing the conductances of specific networks of arterioles, capillaries and venules comprising the arms, legs, stomach and their combinations have been obtained.


Subject(s)
Blood Circulation/physiology , Cardiovascular Physiological Phenomena , Exercise/physiology , Humans , Mathematics , Models, Cardiovascular
12.
Phys Med Biol ; 35(7): 947-59, 1990 Jul.
Article in English | MEDLINE | ID: mdl-2385625

ABSTRACT

Stenosis could affect one or more segments of the human cardiovascular system. It is a problem capable of causing grave effects. In the present study, the finite element method has been utilised to construct a computer simulation model for the human cardiovascular system in which one or more blood carrying elastic segments are affected by stenosis. Computational effects on the effects of stenosis in aorta arch, carotid, and coronary arteries on parameters of steady flow through the system are presented. It is found that when the total flow rate through the heart is maintained constant, the most notable effect is a very marked increase in pressure drop occurring over the length of the vessel affected with stenosis. Pressure drop in many other segments also increases but by a much smaller extent. On the other hand, when the pressure at the inlet of the ascending aorta and the outlet of the vena cava are maintained constant, the most marked effect is a decrease of flow rate through the stenosed vessel. Stenosis not only causes a pressure drop in the affected segments but it also changes pressures at points distal from the site of stenosis. It also causes a redistribution of flow through the cardiovascular system.


Subject(s)
Cardiovascular Diseases/physiopathology , Cardiovascular System/physiopathology , Computer Simulation , Models, Biological , Constriction, Pathologic , Humans , Regional Blood Flow
13.
J Biomech ; 23(6): 513-27, 1990.
Article in English | MEDLINE | ID: mdl-2341415

ABSTRACT

The paper presents a finite-element model for the analysis of steady flow of a viscous fluid through a connected system of elastic tubes with the aim of simulating the conditions of blood flow through the human arterial system. The governing equations of the model are non-linear in character and are solved through an iterative computational procedure. This model is capable of incorporating the effects of stenosis on flow and pressure. Typical results are presented and discussed. Quantitative results have been obtained on blood flow through a model of the human arterial system corresponding to the sets of prescribed conditions at the terminations. Also computational results on the effect of stenosis in typical arteries of the system are presented.


Subject(s)
Arteries/physiology , Models, Cardiovascular , Aorta/physiology , Arterial Occlusive Diseases/physiopathology , Humans , Mathematical Computing , Pressure , Programming Languages , Regional Blood Flow , Viscosity
14.
Phys Med Biol ; 34(7): 795-805, 1989 Jul.
Article in English | MEDLINE | ID: mdl-2780798

ABSTRACT

The effects of the interaction between a magnetic field and the haemodynamics of the arterial system have been studied. An analysis of a supine subject has been carried out in the presence of an externally applied magnetic field. A finite-element technique has been used to solve the magnetohydrodynamics of the fluid flow problem in a network of rigid tubes. The analysis is carried out by considering arteries as rigid tubes, i.e. the arterial expansion is neglected. In real situations, the arteries are elastic. The method requires the derivation of an expression of the conductance of a single artery in the presence of a transverse magnetic field. Computational results corresponding to two different sets of boundary conditions have been obtained. The quantitative effects of intensity and orientation of the applied magnetic field in the presence and absence of stenosis in the aortic arch are presented and discussed.


Subject(s)
Arteries/physiology , Blood Flow Velocity , Electromagnetic Fields , Electromagnetic Phenomena , Hemodynamics , Models, Biological , Humans
16.
J Biomech ; 19(11): 929-41, 1986.
Article in English | MEDLINE | ID: mdl-3793741

ABSTRACT

The human system may be subjected to a body acceleration deliberated for example by making subjects lie down on vibrating tables or more frequently unintentionally, for example during travel in water and land or in air and space. The present study is concerned with the effects of externally imposed body accelerations on blood flow in a branched system of arteries. A finite-element model of flow in the arterial system subject to periodic body accelerations is presented. Computational results on the flow rates through selected arteries and the corresponding inlet and outlet pressures under different conditions (magnitude, frequency and direction) of applied acceleration are presented.


Subject(s)
Acceleration , Arteries/physiology , Models, Cardiovascular , Biomechanical Phenomena , Blood Flow Velocity , Humans , Models, Theoretical , Regional Blood Flow
SELECTION OF CITATIONS
SEARCH DETAIL
...