Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Interv Cardiol ; 19(3): 215-21, 2006 Jun.
Article in English | MEDLINE | ID: mdl-16724961

ABSTRACT

BACKGROUND: The purpose of the European PROCAR Trial was to evaluate the safety and performance of the Protégé stent in the treatment of common and/or internal carotid artery stenoses with adjunctive use of a filter embolic protection device. METHOD: The Protégé GPS stent is a self-expanding Nitinol stent system mounted on a 6 Fr 0.018'' (6-9 mm stent) or 7 Fr 0.035'' (10 mm stent) over-the-wire delivery system. Study patient assessments were conducted at baseline, periprocedure, discharge, and 1 and 6 months postprocedure. A total of 77 patients have been enrolled in the trial. RESULTS: In the 77 lesions treated (31 symptomatic, 46 asymptomatic), the procedure was technically successful in 76 (99%), with an average residual stenosis of less than 30%. One procedure failed because the embolic protection device could not be retrieved and the patient was sent to surgery. Within 30 days, there were four (5.2%) major adverse neurological events (MANEs). Three of the MANEs were major strokes (3.9%), one a minor stroke. The fifth MANE occurred prior to the 6-month follow-up visit; this patient had a major stroke 75 days after the procedure and died 36 days later. One additional death occurred because of urosepsis. CONCLUSIONS: The PROCAR trial shows that the Protégé stent with adjuvant use of a filter embolic protection device satisfies safety and performance criteria for the treatment of carotid artery stenosis. The incidence of MANEs for the Protégé stent is comparable to the incidence of these events in other recent carotid stent studies and standard carotid endarterectomy (CEA).


Subject(s)
Carotid Stenosis/therapy , Stents/adverse effects , Treatment Outcome , Aged , Angioplasty, Balloon , Blood Vessel Prosthesis Implantation , Carotid Stenosis/physiopathology , Europe , Female , Femoral Artery , Hemofiltration/instrumentation , Humans , Incidence , Male , Prospective Studies , Risk Assessment , Vascular Patency
2.
J Interv Cardiol ; 19(1): 55-62, 2006 Feb.
Article in English | MEDLINE | ID: mdl-16483341

ABSTRACT

OBJECTIVE: Several types of cerebral (embolic) protection devices have been used in patients undergoing carotid stenting. This study assessed results achieved with a flow-reversal system. METHOD: Carotid stenting was performed in 56 patients (mean age, 68 +/- 9 years). The mean percentage of stenosis was 77%+/- 10%. During the procedure, cerebral protection was achieved by means of balloon occlusion of the common and external carotid artery with use of a Parodi Anti-Emboli System. The patients' neurologic status was assessed during the intervention; at discharge; 1, 6, and 12 months after the procedure; and yearly thereafter. RESULTS: The procedure was technically successful in all cases. One patient had a minor stroke 6 hours after the intervention. No major strokes, deaths, or myocardial infarctions occurred. During long-term follow-up (to 40 months), 2 patients died of a secondary complication after intracerebral bleeding and stroke and 1 died as a result of ventricular fibrillation. Restenosis did not exceed 50% of vessel diameter in any patient. CONCLUSIONS: The acute results indicate that proximal occlusion and flow reversal for cerebral protection during carotid stenting is a safe and effective method. The low restenosis and complication rate during long-term follow-up is in accordance with other series of carotid angioplasty and shows that the occlusion balloons do not cause any long-term side effects.


Subject(s)
Carotid Artery Diseases/therapy , Cerebral Cortex/blood supply , Constriction, Pathologic/therapy , Stents/adverse effects , Acute Disease , Aged , Aged, 80 and over , Angioplasty, Balloon , Blood Vessel Prosthesis Implantation , Carotid Artery Diseases/physiopathology , Cerebral Cortex/physiopathology , Constriction, Pathologic/physiopathology , Female , Humans , Male , Regional Blood Flow , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...