Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
Add more filters










Publication year range
1.
Phys Rev Lett ; 131(20): 200801, 2023 Nov 17.
Article in English | MEDLINE | ID: mdl-38039452

ABSTRACT

The lack of ability to determine and implement accurately quantum optimal control is a strong limitation to the development of quantum technologies. We propose a digital procedure based on a series of pulses where their amplitudes and (static) phases are designed from an optimal continuous-time protocol for given type and degree of robustness, determined from a geometric analysis. This digitalization combines the ease of implementation of composite pulses with the potential to achieve global optimality, i.e., to operate at the ultimate speed limit, even for a moderate number of control parameters. We demonstrate the protocol on IBM's quantum computers for a single qubit, obtaining a robust transfer with a series of Gaussian or square pulses in a time T=382 ns for a moderate amplitude. We find that the digital solution is practically as fast as the continuous one for square subpulses with the same peak amplitudes.

2.
Entropy (Basel) ; 25(5)2023 May 12.
Article in English | MEDLINE | ID: mdl-37238545

ABSTRACT

Quantum control of lossy systems is known to be achieved by adiabatic passage via an approximate dark state relatively immune to loss, such as the emblematic example of stimulated Raman adiabatic passage (STIRAP) featuring a lossy excited state. By systematic optimal control study, via the Pontryagin maximum principle, we design alternative more efficient routes that, for a given admissible loss, feature an optimal transfer with respect to the cost defined as (i) the pulse energy (energy minimization) or (ii) the pulse duration (time minimization). The optimal controls feature remarkably simple sequences in the respective cases: (i) operating far from a dark state, of π-pulse type in the limit of low admissible loss, or (ii) close to the dark state with a counterintuitive pulse configuration sandwiched by sharp intuitive sequences, referred to as the intuitive/counterintuitive/intuitive (ICI) sequence. In the case of time optimization, the resulting stimulated Raman exact passage (STIREP) outperforms STIRAP in term of speed, accuracy, and robustness for low admissible loss.

3.
Entropy (Basel) ; 25(3)2023 Mar 03.
Article in English | MEDLINE | ID: mdl-36981334

ABSTRACT

We investigate the extent to which a two-level quantum system subjected to an external time-dependent drive can be characterized by supervised learning. We apply this approach to the case of bang-bang control and the estimation of the offset and the final distance to a given target state. For any control protocol, the goal is to find the mapping between the offset and the distance. This mapping is interpolated using a neural network. The estimate is global in the sense that no a priori knowledge is required on the relation to be determined. Different neural network algorithms are tested on a series of data sets. We show that the mapping can be reproduced with very high precision in the direct case when the offset is known, while obstacles appear in the indirect case starting from the distance to the target. We point out the limits of the estimation procedure with respect to the properties of the mapping to be interpolated. We discuss the physical relevance of the different results.

4.
Molecules ; 26(10)2021 May 12.
Article in English | MEDLINE | ID: mdl-34065881

ABSTRACT

We study the application of Optimal Control Theory to Ion Cyclotron Resonance. We test the validity and the efficiency of this approach for the robust excitation of an ensemble of ions with a wide range of cyclotron frequencies. Optimal analytical solutions are derived in the case without any pulse constraint. A gradient-based numerical optimization algorithm is proposed to take into account limitation in the control intensity. The efficiency of optimal pulses is investigated as a function of control time, maximum amplitude and range of excited frequencies. A comparison with adiabatic and SWIFT pulses is done. On the basis of recent results in Nuclear Magnetic Resonance, this study highlights the potential usefulness of optimal control in Ion Cyclotron Resonance.

5.
J Magn Reson ; 303: 42-47, 2019 Jun.
Article in English | MEDLINE | ID: mdl-31003062

ABSTRACT

In high sensitivity inductive electron spin resonance spectroscopy, superconducting microwave resonators with large quality factors are employed. While they enhance the sensitivity, they also distort considerably the shape of the applied rectangular microwave control pulses, which limits the degree of control over the spin ensemble. Here, we employ shaped microwave pulses compensating the signal distortion to drive the spins faster than the resonator bandwidth. This translates into a shorter echo, with enhanced signal-to-noise ratio. The shaped pulses are also useful to minimize the dead-time of our spectrometer, which allows to reduce the wait time between successive drive pulses.

6.
Magn Reson Med ; 81(1): 424-438, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30265759

ABSTRACT

PURPOSE: This article proposes a rigorous optimal control framework for the design of preparation schemes that optimize MRI contrast based on relaxation time differences. METHODS: Compared to previous optimal contrast preparation schemes, a drastic reduction of the optimization parameter number is performed. The preparation scheme is defined as a combination of several block pulses whose flip angles, phase terms and inter-pulse delays are optimized to control the magnetization evolution. RESULTS: The proposed approach reduces the computation time of B 0 -robust preparation schemes to around a minute (whereas several hours were required with previous schemes), with negligible performance loss. The chosen parameterization allows to formulate the total preparation duration as a constraint, which improves the overall compromise between contrast performance and preparation time. Simulation, in vitro and in vivo results validate this improvement, illustrate the straightforward applicability of the proposed approach, and point out its flexibility in terms of achievable contrasts. Major improvement is especially achieved for short-T2 enhancement, as shown by the acquisition of a non-trivial contrast on a rat brain, where a short-T2 white matter structure (corpus callosum) is enhanced compared to surrounding gray matter tissues (hippocampus and neocortex). CONCLUSIONS: This approach proposes key advances for the design of optimal contrast preparation sequences, that emphasize their ability to generate non-standard contrasts, their potential benefit in a clinical context, and their straightforward applicability on any MR system.


Subject(s)
Brain/diagnostic imaging , Contrast Media/pharmacology , Magnetic Resonance Imaging , Aging , Algorithms , Alzheimer Disease/diagnostic imaging , Animals , Computer Simulation , Corpus Callosum/diagnostic imaging , Female , Gray Matter/diagnostic imaging , Hippocampus/diagnostic imaging , Humans , Magnetics , Models, Theoretical , Multiple Sclerosis/diagnostic imaging , Phantoms, Imaging , Rats , Thalamus/diagnostic imaging
7.
J Magn Reson ; 294: 153-161, 2018 09.
Article in English | MEDLINE | ID: mdl-30053754

ABSTRACT

This article presents a new motion encoding strategy to perform magnetic resonance elastography (MRE). Instead of using standard motion encoding gradients, a tailored RF pulse is designed to simultaneously perform selective excitation and motion encoding in presence of a constant gradient. The RF pulse is designed with a numerical optimal control algorithm, in order to obtain a magnetization phase distribution that depends on the displacement characteristics inside each voxel. As a consequence, no post-excitation encoding gradients are required. This offers numerous advantages, such as reducing eddy current artifacts, and relaxing the constraint on the gradients maximum switch rate. It also allows to perform MRE with ultra-short TE acquisition schemes, which limits T2 decay and optimizes signal-to-noise ratio. The pulse design strategy is developed and analytically analyzed to clarify the encoding mechanism. Finally, simulations, phantom and ex vivo experiments show that phase-to-noise ratios are improved when compared to standard MRE encoding strategies.

8.
J Magn Reson ; 279: 39-50, 2017 06.
Article in English | MEDLINE | ID: mdl-28460243

ABSTRACT

This work investigates the use of MRI radio-frequency (RF) pulses designed within the framework of optimal control theory for image contrast optimization. The magnetization evolution is modeled with Bloch equations, which defines a dynamic system that can be controlled via the application of the Pontryagin Maximum Principle (PMP). This framework allows the computation of optimal RF pulses that bring the magnetization to a given state to obtain the desired contrast after acquisition. Creating contrast through the optimal manipulation of Bloch equations is a new way of handling contrast in MRI, which can explore the theoretical limits of the system. Simulation experiments carried out on-resonance quantify the contrast improvement when compared to standard T1 or T2 weighting strategies. The use of optimal pulses is also validated for the first time in both in vitro and in vivo experiments on a small-animal 4.7T MR system. Results demonstrate their robustness to static field inhomogeneities as well as the fact that they can be embedded in standard imaging sequences without affecting standard parameters such as slice selection or echo type. In vivo results on rat and mouse brains illustrate the ability of optimal contrast pulses to create non-trivial contrasts on well-studied structures (white matter versus gray matter).


Subject(s)
Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Algorithms , Animals , Brain/diagnostic imaging , Computer Simulation , Female , Gray Matter/diagnostic imaging , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Mice , Muscle, Skeletal/diagnostic imaging , Phantoms, Imaging , Rats , Reproducibility of Results , White Matter/diagnostic imaging
9.
J Magn Reson ; 281: 82-93, 2017 08.
Article in English | MEDLINE | ID: mdl-28558274

ABSTRACT

This paper investigates the use of Optimal Control (OC) theory to design Radio-Frequency (RF) pulses that actively control the spatial distribution of the MRI magnetization phase. The RF pulses are generated through the application of the Pontryagin Maximum Principle and optimized so that the resulting transverse magnetization reproduces various non-trivial and spatial phase patterns. Two different phase patterns are defined and the resulting optimal pulses are tested both numerically with the ODIN MRI simulator and experimentally with an agar gel phantom on a 4.7T small-animal MR scanner. Phase images obtained in simulations and experiments are both consistent with the defined phase patterns. A practical application of phase control with OC-designed pulses is also presented, with the generation of RF pulses adapted for a Magnetic Resonance Elastography experiment. This study demonstrates the possibility to use OC-designed RF pulses to encode information in the magnetization phase and could have applications in MRI sequences using phase images.

10.
Opt Lett ; 36(20): 4038-40, 2011 Oct 15.
Article in English | MEDLINE | ID: mdl-22002378

ABSTRACT

We consider the counterpropagating interaction of a signal and a pump beam in a spun fiber and in a randomly birefringent fiber, the latter being relevant to optical telecommunication systems. On the basis of a geometrical analysis of the Hamiltonian singularities of the system, we provide a complete understanding of the phenomenon of polarization attraction in these two systems, which allows to achieve a control of the polarization state of the signal beam by adjusting the polarization of the pump. In spun fibers, all polarization states of the signal beam are attracted toward a specific line of polarization states on the Poincaré sphere, whose characteristics are determined by the polarization state of the injected backward pump. In randomly birefringent telecommunication fibers, we show that an unpolarized signal beam can be repolarized into any particular polarization state, without loss of energy.

SELECTION OF CITATIONS
SEARCH DETAIL
...