1.
HardwareX ; 18: e00533, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38711599

ABSTRACT

Microscopes are essential for the biomechanical and hydrodynamical investigation of small aquatic organisms. We report a prototype of a do-it-yourself microscope that enables the visualization of organisms from two orthogonal imaging planes - top and side views. Compared to conventional imaging systems, this approach provides a comprehensive visualization strategy of organisms, which could have complex shapes and morphologies. The microscope was constructed by combining custom 3D-printed parts and off-the-shelf components. The system is designed for modularity and reconfigurability. Open-source design files and build instructions are provided in this report. Additionally, proof-of-use experiments (particularly with Hydra) and other organisms that combine the imaging with an analysis pipeline were demonstrated to highlight the system's utility. Beyond the applications demonstrated, the system can be used or modified for various imaging applications.

2.
Heliyon ; 10(6): e27310, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38509976

ABSTRACT

Since the introduction of transcatheter aortic valve (AV) implantation as a viable option, surgical bioprosthetic AVs have recently started incorporating shorter struts considering future valve-in-valve procedures. However, the effect of leaflet coaptation geometry on the longevity of these valves remains unexplored. To address this gap, we performed a finite element analysis on bioprosthetic AVs with varying strut heights using a two-way fluid-structure interaction method. To establish a baseline, we used a standard height based on a rendered platform image of the CE PERIMOUNT Magna Ease valve from Edward Lifesciences in Irvine, CA. Bovine pericardium properties were assigned to the leaflets, while normal saline properties were used as the recirculating fluid in hemodynamic simulations. The physiological pressure profile of the cardiac cycle was applied between the aorta and left ventricle. We calculated blood flow velocity, effective orifice area (EOA), and mechanical stress on the leaflets. The results reveal that as the strut height increases, the stroke volume increases, leakage volume decreases, and EOA improves. Additionally, the maximum mechanical stress experienced by the leaflet decreases by 62% as the strut height increases to 1.2 times the standard height. This research highlights that a low-strut design in bioprosthetic AVs may negatively affect their durability, which can be useful in design of next-generation bioprosthetic AVs.

3.
ArXiv ; 2023 Jul 24.
Article in English | MEDLINE | ID: mdl-37547659

ABSTRACT

Microscopes are essential for the biomechanical and hydrodynamical investigation of small aquatic organisms. We report a do-it-yourself microscope (GLUBscope) that enables the visualization of organisms from two orthogonal imaging planes - top and side views. Compared to conventional imaging systems, this approach provides a comprehensive visualization strategy of organisms, which could have complex shapes and morphologies. The microscope was constructed by combining custom 3D-printed parts and off-the-shelf components. The system is designed for modularity and reconfigurability. Open-source design files and build instructions are provided in this report. Additionally, proof-of-use experiments (particularly with Hydra) and other organisms that combine the GLUBscope with an analysis pipeline were demonstrated to highlight the system's utility. Beyond the applications demonstrated, the system can be used or modified for various imaging applications.

4.
J Endovasc Ther ; : 15266028231187741, 2023 Jul 24.
Article in English | MEDLINE | ID: mdl-37485662

ABSTRACT

PURPOSE: This study presents analytic techniques to quantify cardiac pulsatility-induced deformations of thoracic aortic endografts in patients with thoracic aortic aneurysm (TAA), dissection (TAD), and blunt thoracic aortic injury (BTAI) after thoracic endovascular aortic repair (TEVAR). TECHNIQUE: We analyzed 19 image data sets from 14 patients treated for TAA, TAD, and BTAI with cardiac-gated post-TEVAR CTs. Systolic and diastolic geometric models were constructed and diametric, axial, and bending deformations were quantified. For patients with cardiac-gated pre-op scans, the damping of pulsatile diametric distension was computed. Maximum localized diametric distension was 2.4±1.0%, 4.2±1.7%, and 5.5±1.6%, and axial deformation was 0.0±0.1%, -0.1±0.3%, and 1.1±0.6% in the endografts of TAA, TAD, and BTAI cohorts, respectively. Diametric distension damping from pre- to post-TEVAR was ~50%. Diametric and bending deformations were localized at certain axial positions on the endograft, and the inner curve bends more than the centerline, especially adjacent to overlapping regions. CONCLUSION: The presented techniques support investigation of multi-axial endograft deformations between disease causes and geometric locations on the device. Discretized quantification of deformation is needed to define device fatigue testing conditions and predict device durability in patients. CLINICAL IMPACT: This study demonstrates analytic techniques to quantify discretized deformation of thoracic endografts. Cardiac-resolved computed tomography is sometimes acquired for surgical planning and follow-up, however, the dynamic data are not typically used to quantify pulsatile deformations. Our analytic techniques extract the centerline and surface geometry of the stented thoracic aorta during the cardiac cycle, which are used to quantify diametric, axial, and bending deformations to provide better understanding of device durability and impact on the native anatomy.

5.
J Endovasc Ther ; : 15266028231179592, 2023 Jun 10.
Article in English | MEDLINE | ID: mdl-37300396

ABSTRACT

PURPOSE: Type B aortic dissections propagate with either achiral (nonspiraling) or right-handed chiral (spiraling) morphology, have mobile dissection flaps, and are often treated with thoracic endovascular aortic repair (TEVAR). We aim to quantify cardiac-induced helical deformation of the true lumen of type B aortic dissections before and after TEVAR. MATERIAL AND METHODS: Retrospective cardiac-gated computed tomography (CT) images before and after TEVAR of type B aortic dissections were used to construct systolic and diastolic 3-dimensional (3D) surface models, including true lumen, whole lumen (true+false lumens), and branch vessels. This was followed by extraction of true lumen helicity (helical angle, twist, and radius) and cross-sectional (area, circumference, and minor/major diameter ratio) metrics. Deformations between systole and diastole were quantified, and deformations between pre- and post-TEVAR were compared. RESULTS: Eleven TEVAR patients (59.9±4.6 years) were included in this study. Pre-TEVAR, there were no significant cardiac-induced deformations of helical metrics; however, post-TEVAR, significant deformation was observed for the true lumen proximal angular position. Pre-TEVAR, cardiac-induced deformations of all cross-sectional metrics were significant; however, only area and circumference deformations remained significant post-TEVAR. There were no significant differences of pulsatile deformation from pre- to post-TEVAR. Variance of proximal angular position and cross-sectional circumference deformation decreased after TEVAR. CONCLUSION: Pre-TEVAR, type B aortic dissections did not exhibit significant helical cardiac-induced deformation, indicating that the true and false lumens move in unison (do not move with respect to each other). Post-TEVAR, true lumens exhibited significant cardiac-induced deformation of proximal angular position, suggesting that exclusion of the false lumen leads to greater rotational deformations of the true lumen and lack of true lumen major/minor deformation post-TEVAR means that the endograft promotes static circularity. Population variance of deformations is muted after TEVAR, and dissection acuity influences pulsatile deformation while pre-TEVAR chirality does not. CLINICAL IMPACT: Description of thoracic aortic dissection helical morphology and dynamics, and understanding the impact of thoracic endovascular aortic repair (TEVAR) on dissection helicity, are important for improving endovascular treatment. These findings provide nuance to the complex shape and motion of the true and false lumens, enabling clinicians to better stratify dissection disease. The impact of TEVAR on dissection helicity provides a description of how treatment alters morphology and motion, and may provide clues for treatment durability. Finally, the helical component to endograft deformation is important to form comprehensive boundary conditions for testing and developing new endovascular devices.

6.
J Vasc Surg Venous Lymphat Disord ; 11(5): 1014-1022, 2023 09.
Article in English | MEDLINE | ID: mdl-37172935

ABSTRACT

OBJECTIVE: In the present study, we characterized deformations of venous stents implanted into common iliac veins for nonthrombotic iliac vein lesions and iliofemoral veins for deep vein thrombosis due to hip movements commensurate with everyday activities such as walking, sitting, and stair climbing. METHODS: Patients treated with iliofemoral venous stents were recruited from three centers and underwent imaging with two orthogonal two-dimensional projection radiographs. Stents in the common iliac veins and iliofemoral veins crossing the hip joint were imaged with the hip in 0°, 30°, 90° and -15°, 0°, and 30° positions, respectively. Using the radiographs, the three-dimensional geometries of the stents were constructed for each hip position, and the diametric and bending deformations between those positions were quantified. RESULTS: Twelve patients were included, and the findings showed that the common iliac vein stents experienced approximately twofold more local diametric compression with 90° hip flexion compared with 30° flexion. Also, iliofemoral vein stents crossing the hip joint experienced significant bending with hip hyperextension (-15°) but not with hip flexion. In both anatomic locations, maximum local diametric and bending deformations were in proximity with each other. CONCLUSIONS: Stents implanted in the common iliac and iliofemoral veins exhibit greater deformation during high hip flexion and hyperextension, respectively, and iliofemoral venous stents interact with the superior ramus of the pubis during hyperextension. These findings suggest that device fatigue could be influenced by the type and level of patient physical activity, in addition to anatomic positioning, opening up the potential benefit of activity modification and the use of a careful implantation strategy. The proximity of maximum diametric and bending deformations means that simultaneous multimodal deformations should be considered for device design and evaluation.


Subject(s)
Iliac Vein , Stents , Humans , Treatment Outcome , Iliac Vein/diagnostic imaging , Femoral Vein/diagnostic imaging , Vena Cava, Inferior , Retrospective Studies
7.
J Endovasc Ther ; : 15266028231168351, 2023 May 05.
Article in English | MEDLINE | ID: mdl-37144300

ABSTRACT

PURPOSE: We aim to quantify multiaxial cardiac pulsatility-induced deformation of the thoracic aorta after ascending thoracic endovascular aortic repair (TEVAR) as a part of the GORE ARISE Early Feasibility Study. MATERIALS AND METHODS: Fifteen patients (7 females and 8 males, age 73±9 years) with ascending TEVAR underwent computed tomography angiography with retrospective cardiac gating. Geometric modeling of the thoracic aorta was performed; geometric features including axial length, effective diameter, and centerline, inner surface, and outer surface curvatures were quantified for systole and diastole; and pulsatile deformations were calculated for the ascending aorta, arch, and descending aorta. RESULTS: From diastole to systole, the ascending endograft exhibited straightening of the centerline (0.224±0.039 to 0.217±0.039 cm-1, p<0.05) and outer surface (0.181±0.028 to 0.177±0.029 cm-1, p<0.05) curvatures. No significant changes were observed for inner surface curvature, diameter, or axial length in the ascending endograft. The aortic arch did not exhibit any significant deformation in axial length, diameter, or curvature. The descending aorta exhibited small but significant expansion of effective diameter from 2.59±0.46 to 2.63±0.44 cm (p<0.05). CONCLUSION: Compared with the native ascending aorta (from prior literature), ascending TEVAR damps axial and bending pulsatile deformations of the ascending aorta similar to how descending TEVAR damps descending aortic deformations, while diametric deformations are damped to a greater extent. Downstream diametric and bending pulsatility of the native descending aorta was muted compared with that in patients without ascending TEVAR (from prior literature). Deformation data from this study can be used to evaluate the mechanical durability of ascending aortic devices and inform physicians about the downstream effects of ascending TEVAR to help predict remodeling and guide future interventional strategies. CLINICAL IMPACT: This study quantified local deformations of both stented ascending and native descending aortas to reveal the biomechanical impact of ascending TEVAR on the entire thoracic aorta, and reported that the ascending TEVAR muted cardiac-induced deformation of the stented ascending aorta and native descending aorta. Understanding of in vivo deformations of the stented ascending aorta, aortic arch and descending aorta can inform physicians about the downstream effects of ascending TEVAR. Notable reduction of compliance may lead to cardiac remodeling and long-term systemic complications. This is the first report which included dedicated deformation data regarding ascending aortic endograft from clinical trial.

8.
Vascular ; 31(2): 234-243, 2023 Apr.
Article in English | MEDLINE | ID: mdl-34963378

ABSTRACT

OBJECTIVE: Practice patterns and durability of parallel stent graft techniques in complex endovascular aneurysm repair (EVAR) remain poorly defined. We aimed to quantify and compare the impact of renal chimney intra-aortic stent length (IASL) on geometric deformations of renal arteries in complex EVAR. METHODS: Thirty-eight nonconsecutive patients underwent EVAR utilizing parallel stent graft techniques (chimney EVAR [chEVAR], n = 28; chimney endovascular aneurysm sealing [chEVAS], n = 10) between 2010 and 2016. A total of 59 renal chimney stent grafts were used. Geometric quantification was derived from three-dimensional model-based centerline extraction. Renal chimney intra-aortic stent length (IASL) was defined as the length of chimney stent that extended from the proximal edge of the chimney stent to the ostium of the corresponding renal artery. RESULTS: Mean IASL for both left and right renal arteries in the cohort was 35.7 mm. Renal arteries containing chimney IASL <30 mm trended toward a greater branch angle (135.4 vs. 127.8°, p = .06). Left renal arteries showed significantly greater branch angle among those with IASL <40 mm (135.5 vs. 121.7°, p = .045). Mean IASL for renal arteries in chEVAR was significantly longer compared to chEVAS (39.2 vs. 26.3 mm, p = .003). No difference was noted in overall branch angle or end-stent angle based on procedure type. ChEVAR with IASL <30 mm had significantly greater end-stent angle (48.2 vs. 33.5°, p = .03). In contrast, chEVAS patients showed no difference in end-stent angle based on IASL thresholds, but did have significantly greater branch angle among those with IASL <30 mm when grouped by both all renal arteries (133.5 vs. 113.5°, p = .004) and right renal arteries (134.3 vs. 111.6°, p = .02). CONCLUSIONS: Renal chimney stents with longer IASL appear to exhibit less renal artery deformation, suggesting a more gradual and perpendicular transition of the chimney stent across the renal ostium.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Humans , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/methods , Endovascular Aneurysm Repair , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Treatment Outcome , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Aortography/methods , Stents , Prosthesis Design
9.
J Vasc Surg ; 74(5): 1499-1507.e1, 2021 11.
Article in English | MEDLINE | ID: mdl-33940073

ABSTRACT

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) can change the morphology of the flow lumen in aortic dissections, which may affect aortic hemodynamics and function. This study characterizes how the helical morphology of the true lumen in type B aortic dissections is altered by TEVAR. METHODS: Patients with type B aortic dissection who underwent computed tomography angiography before and after TEVAR were retrospectively reviewed. Images were used to construct three-dimensional stereolithographic surface models of the true lumen and whole aorta using custom software. Stereolithographic models were segmented and co-registered to determine helical morphology of the true lumen with respect to the whole aorta. The true lumen region covered by the endograft was defined based on fiducial markers before and after TEVAR. The helical angle, average helical twist, peak helical twist, and cross-sectional eccentricity, area, and circumference were quantified in this region for pre- and post-TEVAR geometries. RESULTS: Sixteen patients (61.3 ± 8.0 years; 12.5% female) were treated successfully for type B dissection (5 acute and 11 chronic) with TEVAR and scans before and after TEVAR were retrospectively obtained (follow-up interval 52 ± 91 days). From before to after TEVAR, the true lumen helical angle (-70.0 ± 71.1 to -64.9 ± 75.4°; P = .782), average helical twist (-4.1 ± 4.0 to -3.7 ± 3.8°/cm; P = .674), and peak helical twist (-13.2 ± 15.2 to -15.4 ± 14.2°/cm; P = .629) did not change. However, the true lumen helical radius (1.4 ± 0.5 to 1.0 ± 0.6 cm; P < .05) and eccentricity (0.9 ± 0.1 to 0.7 ± 0.1; P < .05) decreased, and the cross-sectional area (3.0 ± 1.1 to 5.0 ± 2.0 cm2; P < .05) and circumference (7.1 ± 1.0 to 8.0 ± 1.4 cm; P < .05) increased significantly from before to after TEVAR. The distinct bimodal distribution of chiral and achiral native dissections disappeared after TEVAR, and subgroup analyses showed that the true lumen circumference of acute dissections increased with TEVAR, although it did not for chronic dissections. CONCLUSIONS: The unchanged helical angle and average and peak helical twists as a result of TEVAR suggest that the angular positions of the true lumen are constrained and that the endografts were helically conformable in the angular direction. The decrease of helical radius indicated a straightening of the corkscrew shape of the true lumen, and in combination with more circular and expanded lumen cross-sections, TEVAR produced luminal morphology that theoretically allows for lower flow resistance through the endografted portion. The impact of TEVAR on dissection flow lumen morphology and the interaction between endografts and aortic tissue can provide insight for improving device design, implantation technique, and long-term clinical outcomes.


Subject(s)
Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Aortography , Blood Vessel Prosthesis Implantation , Computed Tomography Angiography , Endovascular Procedures , Tomography, Spiral Computed , Aged , Aortic Dissection/diagnostic imaging , Aortic Dissection/physiopathology , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/physiopathology , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Female , Hemodynamics , Humans , Male , Middle Aged , Predictive Value of Tests , Prosthesis Design , Regional Blood Flow , Retrospective Studies , Stents , Time Factors , Treatment Outcome
10.
Eur J Radiol Open ; 8: 100333, 2021.
Article in English | MEDLINE | ID: mdl-33748348

ABSTRACT

PURPOSE: The thoracic aorta is a highly mobile organ whose dynamics are altered by thoracic endovascular aorta repair (TEVAR). The aim of this study was to quantify cardiac pulsatility-induced multi-axial deformation of the thoracic aorta before and after descending aortic TEVAR. METHODS: Eleven TEVAR patients (8 males and 3 females, age 57-89) underwent retrospective cardiac-gated CT angiography before and after TEVAR. 3D geometric models of the thoracic aorta were constructed, and lumen centerlines, inner and outer surface curves, and cross-sections were extracted to measure aortic arclength, centerline, inner surface, and outer surface longitudinal curvatures, as well as cross-sectional effective diameter and eccentricity for the ascending and stented aortic portions. RESULTS: From pre- to post-TEVAR, arclength deformation was increased at the ascending aorta from 5.9 ±â€¯3.1 % to 8.8 ±â€¯4.4 % (P < 0.05), and decreased at the stented aorta from 7.5 ±â€¯5.1 % to 2.7 ±â€¯2.5 % (P < 0.05). Longitudinal curvature and diametric deformations were reduced at the stented aorta. Centerline curvature, inner surface curvature, and cross-sectional eccentricity deformations were increased at the distal ascending aorta. CONCLUSIONS: Deformations were reduced in the stented thoracic aorta after TEVAR, but increased in the ascending aorta near the aortic arch, possibly as a compensatory mechanism to maintain overall thoracic compliance in the presence of reduced deformation in the stiffened stented aorta.

11.
J Vasc Surg ; 74(2): 396-403, 2021 08.
Article in English | MEDLINE | ID: mdl-33548438

ABSTRACT

OBJECTIVE: We evaluated the respiratory-induced changes in branch vessel geometry after thoracoabdominal fenestrated endovascular aneurysm repair (fEVAR) with the Bentley BeGraft graft (Innomed GmbH, Hechingen, Germany) as the covered bridging stent. METHODS: Patients treated with fEVAR for thoracoabdominal aortic aneurysms with a custom-made Zenith fenestrated endograft (Cook Medical Europe Ltd, Limerick, Ireland) and Bentley BeGraft peripheral stents were prospectively recruited. Using SimVascular software (Open-Source Medical Software Corp, San Diego, CA), the pre- and postoperative aortic and branch contours were segmented from computed tomography angiograms performed during inspiratory and expiratory breath-holds. The centerlines were extracted from the lumen contours, from which the branch take-off angles, distal stent angles, and peak branch curvature changes were computed. Paired, two-tailed t tests were performed to compare the pre- and postoperative deformations. RESULTS: Renovisceral vessel geometry was evaluated in 12 patients undergoing fEVAR with a total of 46 target vessels (10 celiac arteries, 12 superior mesenteric arteries [SMAs], 24 renal arteries). Implantation of BeGraft bridging stents was associated with a significant reduction in respiration-induced changes in vessel branch angulation (Δ5.3° ± 3.9° vs Δ12.0° ± 8.3° [postoperative vs preoperative]; P = .001) and mean curvature (0.72 ± 0.22 cm-1 vs 0.53 ± 0.18 cm-1) in the renal arteries, without significant changes in the celiac arteries or SMAs. No significant difference was found in end-stent angle motion in the renal arteries (P = .77), celiac arteries (P = .34), or SMAs (P = .55). The maximum local vessel curvature change decreased after fEVAR in the SMAs (Δ0.28 cm-1 vs Δ0.47 cm-1; P = .04) but was unchanged in the celiac (P = .61) and renal (P = .51) arteries. CONCLUSIONS: Implantation of the BeGraft as a bridging stent in fEVAR was associated with decreased respiratory-induced deformation in the renal branch take-off angulation and mean renal artery curvature, with reduced maximum curvature bending in the SMA compared with the preoperative anatomy. However, the BeGraft allowed for celiac and renal artery bending similar to that in the native preoperative state. These findings suggest that the use of BeGraft peripheral stents with fEVAR will closely mimic the native arterial branch geometry and vessel conformability caused by relatively aggressive respiratory motion.


Subject(s)
Angioplasty, Balloon/instrumentation , Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Aortography , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Computed Tomography Angiography , Respiration , Stents , Aged , Aged, 80 and over , Angioplasty, Balloon/adverse effects , Aorta, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Female , Humans , Male , Postoperative Complications/diagnostic imaging , Predictive Value of Tests , Prospective Studies , Prosthesis Design , Time Factors , Treatment Outcome
12.
Am J Physiol Heart Circ Physiol ; 320(2): H901-H911, 2021 02 01.
Article in English | MEDLINE | ID: mdl-33382638

ABSTRACT

Chirality is a fundamental property in many biological systems. Motivated by previous observations of helical aortic blood flow, aortic tissue fibers, and propagation of aortic dissections, we introduce methods to characterize helical morphology of aortic dissections. After validation on computer-generated phantoms, the methods were applied to patients with type B dissection. For this cohort, there was a distinct bimodal distribution of helical propagation of the dissection with either achiral or exclusively right-handed chirality, with no intermediate cases or left-handed cases. This clear grouping indicates that dissection propagation favors these two modes, which is potentially due to the right-handedness of helical aortic blood flow and cell orientation. The characterization of dissection chirality and quantification of helical morphology advances our understanding of dissection pathology and lays a foundation for applications in clinical research and treatment practice. For example, the chirality and magnitude of helical metrics of dissections may indicate risk of dissection progression, help define treatment and surveillance strategies, and enable development of novel devices that account for various helical morphologies.NEW & NOTEWORTHY A novel definition of helical propagation of type B aortic dissections reveals a distinct bimodality, with the true lumen being either achiral (nonhelical) or exclusively right-handed. This right-handed chirality is consistent with anatomic and physiological phenomena such as right-handed twist during left ventricle contraction, helical blood flow, and tissue fiber direction. The helical character of aortic dissections may be useful for pathology research, diagnostics, treatment selection, therapeutic durability prediction, and aortic device design.


Subject(s)
Aorta, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Dissection/diagnostic imaging , Aortography , Computed Tomography Angiography , Adult , Aged , Aged, 80 and over , Aortic Dissection/physiopathology , Aorta, Thoracic/physiopathology , Aortic Aneurysm, Thoracic/physiopathology , Aortography/instrumentation , Computed Tomography Angiography/instrumentation , Female , Humans , Male , Middle Aged , Phantoms, Imaging , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted , Regional Blood Flow , Reproducibility of Results
13.
J Vasc Surg Venous Lymphat Disord ; 8(6): 953-960, 2020 11.
Article in English | MEDLINE | ID: mdl-32321693

ABSTRACT

BACKGROUND: Stenting of the iliofemoral vein may be an effective treatment to improve post-thrombotic symptoms. Iliofemoral vein stents have requirements different from those of lower extremity artery stents, and there is a paucity of literature regarding the biomechanical motion of the iliofemoral vein. METHODS: In a novel cadaveric model, stents were bilaterally inserted into the veins in the iliofemoral region. The veins were pressurized and underwent computed tomography angiography at various hip angle positions. In addition, 21 patients with iliofemoral vein disease had supine computed tomography angiography before and after stenting. The stents and vasculature were reconstructed into three-dimensional geometric models to quantify stent deformations and the interaction between the iliofemoral vein, inguinal ligament, and pubis bone due to hip flexion-extension. RESULTS: In the cadavers, from supine to 30 to 45 degrees and 50 to 75 degrees of hip flexion, iliofemoral vein stents became less compressed (4.5% minor diameter expansion), and the inguinal ligament was separated from the iliofemoral veins by 1 to 3 cm in all hip positions. In the patients, the pubis compressed 47% of femoral veins; 78% were within 3 mm of the pubis. There was also evidence of contrast-enhanced flow disruption at the superior ramus. CONCLUSIONS: The cadaver and clinical evidence shows that contrary to widely accepted dogma, the common femoral vein is not compressed by the inguinal ligament during hip flexion but rather by the superior ramus of the pubis during hip extension, which may have an impact on future stent design and influence deep venous thrombosis treatment strategies.


Subject(s)
Endovascular Procedures/instrumentation , Femoral Vein/diagnostic imaging , Hip Joint/physiology , Stents , Venous Thrombosis/therapy , Adolescent , Adult , Aged , Aged, 80 and over , Biomechanical Phenomena , Cadaver , Computed Tomography Angiography , Female , Humans , Male , Middle Aged , Patient Positioning , Phlebography , Prospective Studies , Prosthesis Design , Range of Motion, Articular , Treatment Outcome , Venous Thrombosis/diagnostic imaging , Young Adult
14.
J Vasc Surg ; 72(4): 1196-1205, 2020 10.
Article in English | MEDLINE | ID: mdl-32035770

ABSTRACT

OBJECTIVE: Aortic geometry has been shown to influence the development of endograft malapposition (bird-beaking) in thoracic endovascular aortic repair (TEVAR), but the extent of this relationship lacks clarity. The aim of this study was to develop a reproducible method of measuring bird-beak severity and to investigate preoperative geometry associated with bird-beaking. METHODS: The study retrospectively analyzed 20 patients with thoracic aortic aneurysms or type B dissections treated with TEVAR. Computed tomography scans were used to construct three-dimensional geometric models of the preoperative and postoperative aorta and endograft. Postoperative bird-beaking was quantified with length, height, and angle; categorized into a bird-beak group (BBG; n = 10) and no bird-beak group (NBBG; n = 10) using bird-beak height ≥5 mm as a threshold; and correlated to preoperative metrics including aortic cross-sectional area, inner curvature, diameter, and inner curvature × diameter as well as graft diameter and oversizing at the proximal landing zone. RESULTS: Aortic area (1002 ± 118 mm2 vs 834 ± 248 mm2), inner curvature (0.040 ± 0.014 mm-1 vs 0.031 ± 0.012 mm-1), and diameter (35.7 ± 2.1 mm vs 32.2 ± 4.9 mm) were not significantly different between BBG and NBBG; however, inner curvature × diameter was significantly higher in BBG (1.4 ± 0.5 vs 1.0 ± 0.3; P = .030). Inner curvature and curvature × diameter were significantly correlated with bird-beak height (R = 0.462, P = .041; R = 0.592, P = .006) and bird-beak angle (R = 0.680, P < .001; R = 0.712, P < .001). CONCLUSIONS: TEVAR bird-beak severity can be quantified and predicted with geometric modeling techniques, and the combination of high preoperative aortic inner curvature and diameter increases the risk for development of TEVAR bird-beaking.


Subject(s)
Aorta, Thoracic/anatomy & histology , Aortic Aneurysm, Thoracic/surgery , Endoleak/epidemiology , Endovascular Procedures/adverse effects , Stents/adverse effects , Aged , Aged, 80 and over , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/surgery , Aortography , Endoleak/diagnosis , Endoleak/etiology , Endoleak/prevention & control , Endovascular Procedures/instrumentation , Equipment Failure , Feasibility Studies , Female , Humans , Imaging, Three-Dimensional , Male , Middle Aged , Models, Anatomic , Preoperative Period , Retrospective Studies , Risk Assessment/methods , Severity of Illness Index , Tomography, X-Ray Computed
15.
J Biomech Eng ; 142(4)2020 04 01.
Article in English | MEDLINE | ID: mdl-31633168

ABSTRACT

Precise description of vascular morphometry is crucial to support medical device manufacturers and clinicians for improving device development and interventional outcomes. A compact and intuitive method is presented to automatically characterize the surface geometry of tubular anatomic structures and quantify surface curvatures starting from generic stereolithographic (STL) surfaces. The method was validated with software phantoms and used to quantify the longitudinal surface curvatures of 37 human thoracic aortas with aneurysm or dissection. The quantification of surface curvatures showed good agreement with analytic solutions from the software phantoms, and demonstrated better agreement as compared to estimation methods using only centerline geometry and cross-sectional radii. For the human thoracic aortas, longitudinal inner surface curvature was significantly higher than centerline curvature (0.33 ± 0.06 versus 0.16 ± 0.02 cm-1 for mean; 1.38 ± 0.48 versus 0.45 ± 0.11 cm-1 for peak; both p < 0.001). These findings show the importance of quantifying surface curvatures in order to better describe the geometry and biomechanical behavior of the thoracic aorta, which can assist in treatment planning and supplying device manufactures with more precise boundary conditions for mechanical evaluation.


Subject(s)
Aorta, Thoracic , Radiographic Image Interpretation, Computer-Assisted , Cross-Sectional Studies , Humans , Imaging, Three-Dimensional , Models, Cardiovascular , Phantoms, Imaging
16.
J Endovasc Ther ; 26(4): 556-564, 2019 08.
Article in English | MEDLINE | ID: mdl-31210077

ABSTRACT

Purpose: To quantify deformations of renal arteries and snorkel stents after snorkel endovascular aneurysm sealing (Sn-EVAS) resulting from cardiac pulsatility and respiration and compare these deformations to patients with untreated abdominal aortic aneurysms (AAA) and snorkel endovascular aneurysm repair (Sn-EVAR). Materials and Methods: Ten Sn-EVAS patients (mean age 75±6 years; 8 men) were scanned with cardiac-gated, respiration-resolved computed tomography angiography. From 3-dimensional geometric models, changes in renal artery and stent angulation and curvature due to cardiac pulsatility and respiration were quantified. Respiration-induced motions were compared with those of 16 previously reported untreated AAA patients and 11 Sn-EVAR patients. Results: Renal artery bending at the stent end was greater for respiratory vs cardiac influences (6°±7° vs -1°±2°, p<0.025). Respiration caused a 3-fold greater deformation on the left renal artery as compared with the right side. Maximum curvature change was higher for respiratory vs cardiac influences (0.49±0.29 vs 0.24±0.17 cm-1, p<0.025), and snorkel renal stents experienced similar maximum curvature change due to cardiac pulsatility and respiration (0.14±0.10 vs 0.19±0.09 cm-1, p=0.142). When comparing the 3 patient cohorts for respiratory-induced deformation, there was significant renal branch angulation in untreated AAAs, but not in Sn-EVAR or Sn-EVAS, and there was significant bending at the stent end in Sn-EVAR and Sn-EVAS. Maximum curvature change due to respiration was ~10-fold greater in Sn-EVAR and Sn-EVAS compared to untreated AAAs. Conclusion: The findings suggest that cardiac and respiratory influences may challenge the mechanical durability of snorkel stents of Sn-EVAS; similarly, however, respiration may be the primary culprit for tissue irritation, increasing the risk for stent-end thrombosis, especially in the left renal artery. The bending stiffness of snorkel stents in both the Sn-EVAR and Sn-EVAS cohorts damped renal branch angulation while it intensified bending of the artery distal to the snorkel stent. Understanding these device-to-artery interactions is critical as they may affect mechanical durability of branch stents and quality and durability of treatment.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Pulsatile Flow , Renal Artery/surgery , Respiration , Stents , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Aortography , Blood Vessel Prosthesis Implantation/adverse effects , Cardiac-Gated Imaging Techniques , Computed Tomography Angiography , Endovascular Procedures/adverse effects , Female , Humans , Male , Prosthesis Design , Renal Artery/diagnostic imaging , Renal Artery/physiopathology , Time Factors , Treatment Outcome
17.
Vascular ; 27(2): 181-189, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30426849

ABSTRACT

OBJECTIVES: Thoracic endovascular aortic repair has become a preferred treatment strategy for thoracic aortic aneurysms and dissections. Yet, it is not well understood if the performance of endografts is affected by physiologic strain due to cyclic aortic motion during cardiac pulsation and respiration. We aim to quantify cardiac- and respiratory-induced changes of the postthoracic endovascular aortic repair thoracic aorta and endograft geometries. METHODS: Fifteen thoracic endovascular aortic repair patients (66 ± 10 years) underwent cardiac-resolved computed tomography angiographies during inspiratory/expiratory breath holds. The computed tomography angiography images were utilized to build models of the aorta, and lumen centerlines and cross-sections were extracted. Arclength and curvature were computed from the lumen centerline. Effective diameter was computed from cross-sections of the thoracic aorta. Deformation was computed from the mid-diastole to end-systole (cardiac deformation) and expiration to inspiration (respiratory deformation). RESULTS: Cardiac pulsation induced significant changes in arclength, mean curvature, maximum curvature change, and effective diameter of the ascending aorta, as well as effective diameter of the stented aortic segment. Respiration, however, induced significant change in mean curvature and effective diameter of the ascending aorta only. Cardiac-induced arclength change of the ascending aorta was significantly greater than respiratory-induced arclength change. CONCLUSIONS: Deformations are present across the thoracic aorta due to cardiopulmonary influences after thoracic endovascular aortic repair. The geometric deformations are greatest in the ascending aorta and decline at the stented thoracic aorta. Additional investigation is warranted to correlate aortic deformation to endograft performance.


Subject(s)
Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Hemodynamics , Respiration , Aged , Aged, 80 and over , Aortic Dissection/diagnostic imaging , Aortic Dissection/physiopathology , Aorta, Thoracic/diagnostic imaging , Aorta, Thoracic/physiopathology , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/physiopathology , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Computed Tomography Angiography , Endovascular Procedures/instrumentation , Female , Humans , Male , Middle Aged , Prospective Studies , Pulsatile Flow , Stents , Treatment Outcome
18.
Ann Vasc Surg ; 52: 312.e7-312.e12, 2018 Oct.
Article in English | MEDLINE | ID: mdl-29775657

ABSTRACT

The Nellix device uses polymer-filled endobags to stabilize the abdominal aortic aneurysm (AAA) sac which is described as endovascular aneurysm sealing (EVAS). We analyzed cardiac-gated computed tomography angiography scans of repaired AAA with EVAS in 4 patients to evaluate the geometry and cardiac pulsatility-induced deformation. Graft translation and aortic curvature changes were found to be minimal during the cardiac cycle. The mean ± standard deviation changes in renal-aorta angles (1.0 ± 0.9°) were less than the changes in the superior mesenteric artery-aorta angle (4.0 ± 2.1°) (P < 0.01), during the cardiac cycle, demonstrating greater stabilization of the visceral branches closer to the device. These findings confirm stabilization of the abdominal aorta during the cardiac cycle using EVAS.


Subject(s)
Aorta, Abdominal/surgery , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Pulsatile Flow , Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/physiopathology , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Aortography/methods , Cardiac-Gated Imaging Techniques , Computed Tomography Angiography , Humans , Imaging, Three-Dimensional , Patient-Specific Modeling , Prosthesis Design , Radiographic Image Interpretation, Computer-Assisted , Regional Blood Flow , Treatment Outcome
19.
Med Biol Eng Comput ; 56(9): 1659-1668, 2018 Sep.
Article in English | MEDLINE | ID: mdl-29500737

ABSTRACT

Vascular morphology characterization is useful for disease diagnosis, risk stratification, treatment planning, and prediction of treatment durability. To quantify the dynamic surface geometry of tubular-shaped anatomic structures, we propose a simple, rigorous Lagrangian cylindrical coordinate system to monitor well-defined surface points. Specifically, the proposed system enables quantification of surface curvature and cross-sectional eccentricity. Using idealized software phantom examples, we validate the method's ability to accurately quantify longitudinal and circumferential surface curvature, as well as eccentricity and orientation of eccentricity. We then apply the method to several medical imaging data sets of human vascular structures to exemplify the utility of this coordinate system for analyzing morphology and dynamic geometric changes in blood vessels throughout the body. Graphical abstract Pointwise longitudinal curvature of a thoracic aortic endograft surface for systole and diastole, with their absolute difference.


Subject(s)
Algorithms , Blood Vessels/anatomy & histology , Databases as Topic , Diastole/physiology , Humans , Imaging, Three-Dimensional , Models, Anatomic , Phantoms, Imaging , Software , Surface Properties , Systole/physiology , Tomography, X-Ray Computed
20.
Vasc Endovascular Surg ; 52(3): 173-180, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29400263

ABSTRACT

OBJECTIVE: To utilize 3-D modeling techniques to better characterize geometric deformations of the supra-aortic arch branch vessels and descending thoracic aorta after thoracic endovascular aortic repair. METHODS: Eighteen patients underwent endovascular repair of either type B aortic dissection (n = 10) or thoracic aortic aneurysm (n = 8). Computed tomography angiography was obtained pre- and postprocedure, and 3-D geometric models of the aorta and supra-aortic branch vessels were constructed. Branch angle of the supra-aortic branch vessels and curvature metrics of the ascending aorta, aortic arch, and stented thoracic aortic lumen were calculated both at pre- and postintervention. RESULTS: The left common carotid artery branch angle was lower than the left subclavian artery angles preintervention ( P < .005) and lower than both the left subclavian and brachiocephalic branch angles postintervention ( P < .05). From pre- to postoperative, no significant change in branch angle was found in any of the great vessels. Maximum curvature change of the stented lumen from pre- to postprocedure was greater than those of the ascending aorta and aortic arch ( P < .05). CONCLUSION: Thoracic endovascular aortic repair results in relative straightening of the stented aortic region and also accentuates the native curvature of the ascending aorta when the endograft has a more proximal landing zone. Supra-aortic branch vessel angulation remains relatively static when proximal landing zones are distal to the left common carotid artery.


Subject(s)
Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aged , Aortic Dissection/diagnostic imaging , Aorta, Thoracic/diagnostic imaging , Aortic Aneurysm, Thoracic/diagnostic imaging , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Computed Tomography Angiography , Endovascular Procedures/instrumentation , Female , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Design , Radiographic Image Interpretation, Computer-Assisted , Stents , Treatment Outcome